Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Structural phase transformation and Fe valence evolution in FeOxF2-x/C nanocomposite electrodes during lithiation and de-lithiation processes

In this study, the structural changes of FeOxF2-x/C during the first discharge and recharge cycles were studied by ex situ electron microscopy techniques including annular dark field scanning transmission electron microscopy (DF-STEM) imaging, selected area electron diffraction (SAED) and electron energy loss spectroscopy (EELS) as well as by in situ X-ray absorption spectroscopy (XAS). The evolution of the valence state of Fe was determined by combined EELS using the Fe-L edge and XAS using the Fe-K edge. The results of this investigation show that the conversion reaction path during 1st lithiation is very different from the re-conversion path during 1st delithiation. During lithiation, intercalation is first observed followed by conversion into a lithiated rocksalt (Li–Fe–O–F) structure, and metallic Fe and LiF phases. During delithiation, the rocksalt phase does not disappear, but co-exists with an amorphous (rutile type) phase formed initially by the reaction of LiF and Fe. However, a de-intercalation stage is still observed at the end of reconversion similar to a single phase process despite the coexistence of these two (rocksalt and amorphous) phases.

36 MATERIALS SCIENCE↗

Ion Beam Therapy in Europe

At present, seven facilities in Europe treat deep-seated tumors with particle beams, six with proton beams and one with carbon ions. Three of these facilities are in Moscow, St. Petersburg and Dubna, Russia. Other facilities include the TSL Uppsala, Sweden, CPO Orsay, France, and PSI Villigen, Switzerland, all for proton therapy, and GSI, Darmstadt, Germany, which utilizes carbon ions only. But only two of these facilities irradiate with scanned ion beams: the Paul Scherer Institute (PSI), Villigen (protons) and the Gesellschaft fuer Schwerionenforschung (GSI), Darmstadt. These two facilities are experimental units within physics laboratories and have developed the technique of intensity-modulated beam scanning in order to produce irradiation conforming to a 3-D target. There are three proton centers presently under construction in Munich, Essen and Orsay, and the proton facility at PSI has added a superconducting accelerator connected to an isocentric gantry in order to become independent of the accelerator shared with the physics research program. The excellent clinical results using carbon ions at National Institute of Radiological Science (NIRS) in Chiba and GSI have triggered the construction of four new heavy-ion therapy projects (carbon ions and protons), located in Heidelberg, Pavia, Marburg and Kiel. The projects in Heidelberg and Pavia will begin patient treatment in 2009, and the Marburg and Kiel projects will begin in 2010 and 2011, respectively. These centers use different accelerator designs but have the same kind of treatment planning system and use the same approach for the calculation of the biological effectiveness of the carbon ions as developed at GSI [1]. There are many other planned projects in the works. Do not replace the word ''abstract,'' but do replace the rest of this text. If you must insert a hard line break, please use Shift+Enter rather than just tapping your ''Enter'' key. You may want to print this page and refer to it as a style sample before you begin working on your paper.

43 PARTICLE ACCELERATORS↗

The metal-insulator transition in vanadium dioxide: A view at bulk and surface contributions for thin films and the effect of annealing

Vanadium dioxide is investigated as potential oxide barrier in spin switches, and in order to incorporate VO{sub 2} layers in complex multilayer devices, it is necessary to understand the relation between bulk and surface/interface properties. Highly oriented VO{sub 2} thin films were grown on (0001) sapphire single crystal substrates with reactive bias target ion beam deposition. In the analysis of the VO{sub 2} films, bulk-sensitive methods [x-ray diffraction (XRD) and transport measurements] and surface sensitive techniques [photoelectron spectroscopy (PES) and scanning tunneling microscopy and spectroscopy] were employed. The samples were subjected to heating cycles with annealing temperatures of up to 425 and 525 K. Prior to annealing the VO{sub 2} films exhibit the transition from the monoclinic to the tetragonal phase with the concurrent change in conductivity by more than a factor of 10{sup 3} and their phase purity is confirmed by XRD. Annealing to 425 K and thus cycling across the metal-insulator transition (MIT) temperature has no impact on the bulk properties of the VO{sub 2} film but the surface undergoes irreversible electronic changes. The observation of the valence band with PES during the annealing illustrates that the surface adopts a partially metallic character, which is retained after cooling. Annealing to a higher temperature (525 K) triggers a modification of the bulk, which is evidenced by a considerable reduction in the MIT characteristics, and a degradation in crystallite morphology. The local measurement of the conductivity with scanning tunneling spectroscopy shows the transition of the surface from predominantly semiconducting surface prior to annealing to a surface with an overwhelming contribution from metallic sections afterward. The spatial distribution of metallic regions cannot be linked in a unique manner to the crystallite size or location within the crystallites. The onset of oxygen depletion at the surface is held responsible for this behavior. The onset of bulk modification at higher temperatures is most likely linked to oxygen loss and effusion along the grain boundaries and concurrent onset of sintering. Our study focuses on the comparison of the MIT in the bulk and at the surface of thin VO{sub 2} layers and establishes an irreversible modification of the crystallite structure and surface for temperatures exceeding the MIT. The surface modification impacts on the strategies which will be employed to build the metallic contacts to VO{sub 2} layers.

36 MATERIALS SCIENCE↗

Possible mechanism of charge transport and dielectric relaxation in SrO-Bi{sub 2}O{sub 3}-B{sub 2}O{sub 3} glasses

Transparent SrBi{sub 2}B{sub 2}O{sub 7} glasses were prepared via melt-quenching technique and characterized using differential scanning calorimetry and x-ray powder diffraction. The ac conductivities of the glasses were studied as a function of frequency (100 Hz-10 MHz) at different temperatures. The frequency dependence of conductivity has been analyzed using Almond-West expression. The exponent n was nearly unaffected by temperature. Impedance and modulus spectroscopies were employed to further examine the electrical data. Dielectric relaxation exhibited a stretched exponential behavior with a stretching exponent beta independent of temperature. From conductivity analysis we have proposed that the charge transport occurs through the participation of nonbridging oxygen (NBO), which switches positions in a facile manner. The stretched exponential behavior appears to be a direct consequence of the NBO switching mechanism of charge transport.

36 MATERIALS SCIENCE↗

Reactive sputter magnetron reactor for preparation of thin films and simultaneous in situ structural study by X-ray diffraction

The purpose of the designed reactor is (i) to obtain polycrystalline and/or amorphous thin films by controlled deposition induced by a reactive sputtering magnetron and (ii) to perform a parallel in situ structural study of the deposited thin films by X-ray diffraction, in real time, during the whole growth process. The designed reactor allows for the control and precise variation of the relevant processing parameters, namely, magnetron target-to-sample distance, dc magnetron voltage, and nature of the gas mixture, gas pressure and temperature of the substrate. On the other hand, the chamber can be used in different X-ray diffraction scanning modes, namely, {theta}-2{theta} scanning, fixed {alpha}-2{theta} scanning, and also low angle techniques such as grazing incidence small angle X-ray scattering and X-ray reflectivity. The chamber was mounted on a standard four-circle diffractometer located in a synchrotron beam line and first used for a preliminary X-ray diffraction analysis of AlN thin films during their growth on the surface of a (100) silicon wafer.

36 MATERIALS SCIENCE↗

Oxygen diffusivity in silicon derived from dynamical X-ray diffraction

Thickness dependent Pendelloesung oscillations are highly sensitive to strain fields from defects in a host crystal. Based on this, we present a novel technique to measure the precipitation kinetics of oxygen in silicon already at its early stage of clustering at high temperatures. At 900 Degree-Sign C, precipitates with a radius smaller than 4 nm and with a density of 1 {+-} 0.5 Multiplication-Sign 10{sup 13} 1/cm{sup 3} were observed. The technique was calibrated by complementary scanning transmission electron microscope and energy dispersive X-ray measurements in the range of normal diffusivity yielding a diffusion constant of 1.7 {+-} 0.1 Multiplication-Sign 10{sup -12}cm{sup 2}/s, which is close to the literature value of 2.074 Multiplication-Sign 10{sup -12}cm{sup 2}/s. The measurements have been made with the characteristic K{sub {alpha}1}-line of a high voltage tungsten X-ray tube at 59.31 keV, which provides the opportunity to illuminate through complex sample environments like high temperature scattering furnaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self assembled monolayer based liquid crystal biosensor for free cholesterol detection

A unique cholesterol oxidase (ChOx) liquid crystal (LC) biosensor, based on the disruption of orientation in LCs, is developed for cholesterol detection. A self-assembled monolayer (SAM) of Dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride (DMOAP) and (3-Aminopropyl)trimethoxy-silane (APTMS) is prepared on a glass plate by adsorption. The enzyme (ChOx) is immobilized on SAM surface for 12 h before utilizing the film for biosensing purpose. LC based biosensing study is conducted on SAM/ChOx/LC (5CB) cells for cholesterol concentrations ranging from 10 mg/dl to 250 mg/dl. The sensing mechanism has been verified through polarizing optical microscopy, scanning electron microscopy, and spectrometric techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ptychography with broad-bandwidth radiation

Ptychography, a scanning Coherent Diffractive Imaging (CDI) technique, has quickly gained momentum as a robust method to deliver quantitative images of extended specimens. A current conundrum for the development of X-ray CDI is the conflict between a need for higher flux to reach higher resolutions and the requirement to strongly filter the incident beam to satisfy the tight coherence prerequisite of the technique. Latest developments in algorithmic treatment of ptychographic data indicate that the technique is more robust than initially assumed, so that some experimental limitations can be substantially relaxed. Here, we demonstrate that ptychography can be conducted in conditions that were up to now considered insufficient, using a broad-bandwidth X-ray beam and an integrating scintillator-based detector. Our work shows the wide applicability of ptychography and paves the way to high-throughput, high-flux diffractive imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Composition profiling of GaAs/AlGaAs quantum dots grown by droplet epitaxy

Droplet epitaxy (DE) is a growth method which can create III-V quantum dots (QDs) whose optoelectronic properties can be accurately controlled through the crystallisation conditions. In this work, GaAs/AlGaAs DE-QDs have been analyzed with the complimentary techniques of cross-sectional scanning tunneling microscopy and atom probe tomography. Structural details and a quantitative chemical analysis of QDs of different sizes are obtained. Most QDs were found to be pure GaAs, while a small proportion exhibited high intermixing caused by a local etching process. Large QDs with a high aspect ratio were observed to have an Al-rich crown above the GaAs QD. This structure is attributed to differences in mobility of the cations during the capping phase of the DE growth.

36 MATERIALS SCIENCE↗

Imaging the equilibrium state and magnetization dynamics of partially built hard disk write heads

Four different designs of partially built hard disk write heads with a yoke comprising four repeats of NiFe (1 nm)/CoFe (50 nm) were studied by both x-ray photoemission electron microscopy (XPEEM) and time-resolved scanning Kerr microscopy (TRSKM). These techniques were used to investigate the static equilibrium domain configuration and the magnetodynamic response across the entire structure, respectively. Simulations and previous TRSKM studies have made proposals for the equilibrium domain configuration of similar structures, but no direct observation of the equilibrium state of the writers has yet been made. In this study, static XPEEM images of the equilibrium state of writer structures were acquired using x-ray magnetic circular dichroism as the contrast mechanism. These images suggest that the crystalline anisotropy dominates the equilibrium state domain configuration, but competition with shape anisotropy ultimately determines the stability of the equilibrium state. Dynamic TRSKM images were acquired from nominally identical devices. These images suggest that a longer confluence region may hinder flux conduction from the yoke into the pole tip: the shorter confluence region exhibits clear flux beaming along the symmetry axis, whereas the longer confluence region causes flux to conduct along one edge of the writer. The observed variations in dynamic response agree well with the differences in the equilibrium magnetization configuration visible in the XPEEM images, confirming that minor variations in the geometric design of the writer structure can have significant effects on the process of flux beaming.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation between magnetism and “dark stripes” in strained La{sub 1−x}Sr{sub x}CoO{sub 3} epitaxial films (0 ≤ x ≤ 0.1)

Using the technique of aberration-corrected scanning transmission electron microscopy, we performed a systematic analysis for the atomic lattice of the strained La{sub 1−x}Sr{sub x}CoO{sub 3} (0 ≤ x ≤ 0.1) epitaxial films, which have drawn a great attention in recent years because of their anomalous magnetism. Superstructures characterized by dark stripes are observed in the lattice image, evolving with combined Sr-doping and lattice strains. Fascinatingly, we found a close relation between the proportion of the Co ions in dark stripes and the saturation magnetization of the film: the latter grows linearly with the former. This result implies that the magnetism could be exclusively ascribed to the Co ions in dark stripes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new setup for the investigation of swift heavy ion induced particle emission and surface modifications

The irradiation with fast ions with kinetic energies of >10 MeV leads to the deposition of a high amount of energy along their trajectory (up to several ten keV/nm). The energy is mainly transferred to the electronic subsystem and induces different secondary processes of excitations, which result in significant material modifications. A new setup to study these ion induced effects on surfaces will be described in this paper. The setup combines a variable irradiation chamber with different techniques of surface characterizations like scanning probe microscopy, time-of-flight secondary ion, and neutral mass spectrometry, as well as low energy electron diffraction under ultra high vacuum conditions, and is mounted at a beamline of the universal linear accelerator (UNILAC) of the GSI facility in Darmstadt, Germany. Here, samples can be irradiated with high-energy ions with a total kinetic energy up to several GeVs under different angles of incidence. Our setup enables the preparation and in situ analysis of different types of sample systems ranging from metals to insulators. Time-of-flight secondary ion mass spectrometry enables us to study the chemical composition of the surface, while scanning probe microscopy allows a detailed view into the local electrical and morphological conditions of the sample surface down to atomic scales. With the new setup, particle emission during irradiation as well as persistent modifications of the surface after irradiation can thus be studied. We present first data obtained with the new setup, including a novel measuring protocol for time-of-flight mass spectrometry with the GSI UNILAC accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time terahertz imaging through self-mixing in a quantum-cascade laser

We report on a fast self-mixing approach for real-time, coherent terahertz imaging based on a quantum-cascade laser and a scanning mirror. Due to a fast deflection of the terahertz beam, images with frame rates up to several Hz are obtained, eventually limited by the mechanical inertia of the employed scanning mirror. A phase modulation technique allows for the separation of the amplitude and phase information without the necessity of parameter fitting routines. We further demonstrate the potential for transmission imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controlled modulation of hard and soft X-ray induced tunneling currents utilizing coaxial metal-insulator-metal probe tips

Here, the effect of a local external electric field on the barrier potential of a tunneling gap is studied utilizing an emerging technique, synchrotron x-ray scanning tunneling microscopy. Here, we demonstrate that the shape of the potential barrier in the tunneling gap can be altered by a localized external electric field, generated by voltages placed on the metallic outer shield of a nanofabricated coaxial metal-insulator-metal tip, resulting in a controlled linear modulation of the tunneling current. Experiments at hard and soft x-ray synchrotron beamlines reveal that both the chemical contrast and magnetic contrast signals measured by the tip can be drastically enhanced, resulting in improved local detection of chemistry and magnetization at the surface.

36 MATERIALS SCIENCE↗

Electron cyclotron resonance (ECR) magnetometry with a plasma reservoir

The local magnetic field in a Penning–Malmberg trap is found by measuring the temperatures that result when electron plasmas are illuminated by microwave pulses. Multiple heating resonances are observed as the pulse frequencies are swept. The many resonances are due to electron bounce and plasma rotation sidebands. The heating peak corresponding to the cyclotron frequency resonance is identified to determine the magnetic field. A new method for quickly preparing low density electron plasmas for destructive temperature measurements enables a rapid and automated scan of microwave frequencies. This technique can determine the magnetic field to high precision, obtaining an absolute accuracy better than 1 ppm and a relative precision of 26 ppb. One important application is in situ magnetometry for antihydrogen-based tests of charge-parity-time symmetry and of the weak equivalence principle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially-resolved dynamic sampling of different phasic magnetic resonances of nanoparticle ensembles in a magnetotactic bacterium Magnetospirillum magnetotacticum

Abstract Nanoscaled magnetic particle ensembles are promising building blocks for realizing magnon based binary logic. Element-specific real-space monitoring of magnetic resonance modes with sampling rates in the GHz regime is imperative for the experimental verification of future complex magnonic devices. Here we present the observation of different phasic magnetic resonance modes using the element-specific technique of time-resolved scanning transmission x-ray microscopy within a chain of dipolarly coupled Fe 3 O 4 nanoparticles (40–50 nm particle size) inside a single cell of a magnetotactic bacterium Magnetospirillum magnetotacticum . The particles are probed with 25 nm resolution at the Fe L 3 x-ray absorption edge in response to a microwave excitation of 4.07 GHz. A plethora of resonance modes is observed within multiple particle segments oscillating in- and out-of-phase, well resembled by micromagnetic simulations.

time-resolved scanning transmission x-ray microsco↗

SU-F-T-398: Improving Radiotherapy Treatment Planning Using Dual Energy Computed Tomography Based Tissue Characterization

Purpose: Both kVp settings and geometric distribution of various materials lead to significant change of the HU values, showing the largest discrepancy for high-Z materials and for the lowest CT scanning kVp setting. On the other hand, the dose distributions around low-energy brachytherapy sources are highly dependent on the architecture and composition of tissue heterogeneities in and around the implant. Both measurements and Monte Carlo calculations show that improper tissue characterization may lead to calculated dose errors of 90% for low energy and around 10% for higher energy photons. We investigated the ability of dual-energy CT (DECT) to characterize more accurately tissue equivalent materials. Methods: We used the RMI-467 heterogeneity phantom scanned in DECT mode with 3 different set-ups: first, we placed high electron density (ED) plugs within the outer ring of the phantom; then we arranged high ED plugs within the inner ring; and finally ED plugs were randomly distributed. All three setups were scanned with the same DECT technique using a single-source DECT scanner with fast kVp switching (Discovery CT750HD; GE Healthcare). Images were transferred to a GE Advantage workstation for DECT analysis. Spectral Hounsfield unit curves (SHUACs) were then generated from 50 to 140-keV, in 10-keV increments, for each plug. Results: The dynamic range of Hounsfield units shrinks with increased photon energy as the attenuation coefficients decrease. Our results show that the spread of HUs for the three different geometrical setups is the smallest at 80 keV. Furthermore, among all the energies and all materials presented, the largest difference appears at high Z tissue equivalent plugs. Conclusion: Our results suggest that dose calculations at both megavoltage and low photon energies could benefit in the vicinity of bony structures if the 80 keV reconstructed monochromatic CT image is used with the DECT protocol utilized in this work.

60 APPLIED LIFE SCIENCES↗

Structural Origin of Enhanced Luminescence Efficiency of Antimony Irradiated InAs Quantum Dots

We report that Sb irradiation combined with the presence of a GaAs intermediate layer previous to the deposition of a GaSb layer over InAs quantum dots grown by molecular beam epitaxy improves the crystalline quality of these nanostructures. Moreover, this approach to develop III-V-Sb nanostructures causes the formation of quantum dots buried by a confining GaSb layer and, in this way, achieving a type II band alignment. Both phenomena, studied by Conventional transmission electron microscopy (CTEM) and scanning-transmission electron microscope (STEM) techniques are keys to achieve the best room temperature photoluminescence results from InAs/GaAs (001) quantum dots. The Sb flux contributes to the preservation of the quantum dots size and at the same time reduces In diffusion from the wetting layer.

36 MATERIALS SCIENCE↗