Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Planetographic clustering of low-altitude impulsive electric signals in the night ionosphere of Venus

This paper presents maps of the locations of electromagnetic signals, presumably caused by lightning, which were observed at 730 Hz during the first three nighttime observing seasons of Pioneer Venus Orbiter when the spacecraft reached altitudes low enough to detect the signals. The maps show that there are specific 'active regions' of enhanced signal occurrence, and that at least some of these active regions appear to remain fixed in planetographic coordinates from year to year.

Russel, C. T.↗

GPS Ocean Reflection Experiment on Spartan 251

It has recently been demonstrated that the GPS signal which has reflected from the ocean surface contains useful geophysical data from which the sea surface wind speed and other parameters can be extracted. This can be used for remote sensing, similar to present day use of radar altimeters or scatterometers, but with significantly smaller instrumentation because of the utilization of the existing GPS broadcast signal for illumination. Several campaigns of aircraft experimentation have been completed demonstrating this technique and reflected GPS data has been reliably collected from 25 km altitude on a balloon. However, there has not yet been a demonstration that the reflected GPS signal can be detected from orbit with sufficient signal to noise ratio (SNR) to make useful remote sensing measurements. A technology demonstration experiment is planned for a Space Shuttle flight in the late 2000 using the Spartan 251 recoverable carrier. This experiment will be also be the first flight validation of the PiVoT GPS receiver developed in house at the Goddard Space Flight Center. The open-architecture, design of this receiver allows the software modifications to be made which control code-correlator spacing to map out the shape of the reflected signal waveform, which is the most basic data product generated by this instrumentation. A moderate gain left-hand circularly polarized antenna, constructed from an array of off-the-shelf hemispherical antennas will be used to give approximately 6dB of additional gain. Preliminary SNR predictions have been done indicating that this antenna will offer sufficient gain to record waveform measurements. A system level description of the experiment instrumentation, including the receiver, antenna and data storage and retrieval will be given. The visibility of GPS reflections over the mission duration of several hours will be studied, including the effects of the limited beamwidth of the antenna. Additionally, because of the small size of this instrumentation, several other space flight opportunities are being considered in the near term. If these missions materialize, they will be described in the paper as well.

Garrison, James L.↗

GPS Ocean Reflection Experiment on Spartan 251

It has recently been demonstrated that the GPS signal which has reflected from the ocean surface contains useful geophysical data from which the sea surface wind speed and other parameters can be extracted. This can be used for remote sensing, similar to present day use of radar altimeters or scatterometers, but with significantly smaller instrumentation because of the utilization of the existing GPS broadcast signal for illumination. Several campaigns of aircraft experimentation have been completed demonstrating this technique and reflected GPS data has been reliably collected from 25 km altitude on a balloon. However, there has not yet been a demonstration that the reflected GPS signal can be detected from orbit with sufficient signal to noise ratio (SNR) to make useful remote sensing measurements. A technology demonstration experiment was planned for a Space Shuttle flight in the late 2000 using the Spartan 251 recoverable carrier. This experiment would also have been the first flight validation of the PiVoT GPS receiver developed in house at the Goddard Space Flight Center. The "open-architecture" design of this receiver would allow the software modifications to be made which control code-correlator spacing to map out the shape of the reflected signal waveform, which is the most basic data product generated by this instrumentation. A moderate gain left-hand circularly polarized antenna, constructed from an array of off-the-shelf hemispherical antennas was to be used to give approximately 3 to 6 dB of additional gain. Preliminary SNR predictions have been done indicating that this antenna would offer sufficient gain to record waveform measurements. A system level description of the experiment instrumentation, including the receiver, antenna and data storage and retrieval will be given. The visibility of GPS reflections over the mission duration of several hours will be studied, including the effects of the limited beamwidth of the antenna. Spartan 251 has now been postponed with the earliest opportunity in the year 2002. The results of this study however, have been 2 used to further the define the requirements and expected performance of reflected GPS receivers in orbit. Several other space flight opportunities are being considered based upon this new information.

Garrison, James L↗

Signal generation and mixing electronics for frequency-domain lifetime and spectral fluorometry

The present invention additionally comprises a method and apparatus for generating and mixing signals for frequency-domain lifetime and spectral fluorometry. The present invention comprises a plurality of signal generators that generate a plurality of signals where the signal generators modulate the amplitude and/or the frequency of the signals. The present invention uses one of these signals to drive an excitation signal that the present invention then directs and transmits at a target mixture, which absorbs the energy from the excitation signal. The property of fluorescence causes the target mixture to emit an emitted signal that the present invention detects with a signal detector. The present invention uses a plurality of mixers to produce a processor reference signal and a data signal. The present invention then uses a processor to compare the processor reference signal with the data signal by analyzing the differences in the phase and the differences in the amplitude between the two signals. The processor then extracts the fluorescence lifetime and fluorescence spectrum of the emitted signal from the phase and amplitude information using a chemometric analysis.

Cruce, Tommy C.↗

Signal generation and mixing electronics for frequency-domain lifetime and spectral fluorometry

The present invention additionally comprises a method and apparatus for generating and mixing signals for frequency-domain lifetime and spectral fluorometry. The present invention comprises a plurality of signal generators that generate a plurality of signals where the signal generators modulate the amplitude and/or the frequency of the signals. The present invention uses one of these signals to drive an excitation signal that the present invention then directs and transmits at a target mixture, which absorbs the energy from the excitation signal. The property of fluorescence causes the target mixture to emit an emitted signal that the present invention detects with a signal detector. The present invention uses a plurality of mixers to produce a processor reference signal and a data signal. The present invention then uses a processor to compare the processor reference signal with the data signal by analyzing the differences in the phase and the differences in the amplitude between the two signals. The processor then extracts the fluorescence lifetime and fluorescence spectrum of the emitted signal from the phase and amplitude information using a chemometric analysis.

Cruce, Tommy Clay↗

Apparatus and Method to Enable Precision and Fast Laser Frequency Tuning

An apparatus and method is provided to enable precision and fast laser frequency tuning. For instance, a fast tunable slave laser may be dynamically offset-locked to a reference laser line using an optical phase-locked loop. The slave laser is heterodyned against a reference laser line to generate a beatnote that is subsequently frequency divided. The phase difference between the divided beatnote and a reference signal may be detected to generate an error signal proportional to the phase difference. The error signal is converted into appropriate feedback signals to phase lock the divided beatnote to the reference signal. The slave laser frequency target may be rapidly changed based on a combination of a dynamically changing frequency of the reference signal, the frequency dividing factor, and an effective polarity of the error signal. Feed-forward signals may be generated to accelerate the slave laser frequency switching through laser tuning ports.

Chen, Jeffrey R.↗

ROBUST ONLINE MONITORING FOR CALIBRATION ASSESSMENT OF TRANSMITTERS AND INSTRUMENTATION

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. Specifically, the next generation of OLM technology is expected to include newly developed advanced algorithms that improve monitoring of sensor/system performance and enable the use of plant data to derive information that currently cannot be measured. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this paper, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation – fault detection and selection of acceptance criteria • Virtual sensing – signal value prediction and acceptance criteria • Response-time assessment – fault detection and acceptance criteria selection A GP-based uncertainty quantification (UQ) method previously developed for UQ in OLM, was adapted for use in sensor-fault detection and virtual sensing. For signal validation, the various components to the OLM residual (which is computed using an AAKR model) were explicitly defined and modeled using a GP. Evaluation was conducted using flow loop data from multiple sources. Results using experimental data from laboratory-scale flow loops indicate that the approach, while capable of detecting sensor drift, may be incapable of discriminating between sensor drift and model inadequacy. This may be due to a simplification applied in the initial modeling, where the sensor degradation is assumed to be stationary. In the case of virtual sensors, the GP model was used in a predictive mode to estimate the correct sensor reading for sensors that may have failed. Results have indicated the viability of using this approach for virtual sensing. However, the GP model has proven to be computationally expensive, and so alternative algorithms for virtual sensing are being evaluated. Finally, automated approaches to performing noise analysis for extracting sensor response time were developed. Evaluation of this technique using laboratory-scale data indicates that it compares well with manual techniques previously used for noise analysis. Moreover, the automated and manual approaches for noise analysis also compare well with the current “gold standard”, hydraulic ramp testing, for response time monitoring. Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

calibration interval extension↗

Demodulator electronics for laser vibrometry

One of the most important parts of a fiber-laser vibrometer is demodulation electronic section. The distortion, nonlinearity, offset and added noise of measured signal come from electronic circuits and they have direct influence on finale measuring results. Two main parameters of an investigated vibrating object: velocity V(t) and displacement s(t), influence of detected beat signals. They are: the Doppler frequency deviation f(t) and phase shift {phi}(t), respectively. Because of wide range of deviations it is difficult to use just one demodulator. That is the reason why we use three different types of demodulators. The first one is the IQ demodulator, which is the most sensitive one and its output is proportional to the displacement. Each IQ channel is sampled simultaneously by an analog to digital converter (ADC) integrated in a digital signal processor (DSP). The output signals from the two FM demodulators are proportional to the frequency deviation of heterodyne signals. They are sensitive directly to the velocity of the object. The main disadvantage of scattered light interferometry system is a ''speckle effect'', appearing in relatively large amplitude fluctuation of a heterodyne signal. To minimize ''speckle effect'' influence on quality of beat signals we applied the automatic gain control (AGC) system. Data acquisition, further signal processing (e.g. vibration frequency spectra) and presentation of results is realized by PC via USB interface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gravitational wave propagation beyond general relativity: waveform distortions and echoes

We study the cosmological propagation of gravitational waves (GWs) beyond general relativity (GR) across homogeneous and isotropic backgrounds. We consider scenarios in which GWs interact with an additional tensor field and use a parametrized phenomenological approach that generically describes their coupled equations of motion. We analyze four distinct classes of derivative and non-derivative interactions: mass, friction, velocity, and chiral. We apply the WKB formalism to account for the cosmological evolution and obtain analytical solutions to these equations. We corroborate these results by analyzing numerically the propagation of a toy GW signal. We then proceed to use the analytical results to study the modified propagation of realistic GWs from merging compact binaries, assuming that the GW signal emitted is the same as in GR. We generically find that tensor interactions lead to copies of the originally emitted GW signal, each one with its own possibly modified dispersion relation. These copies can travel coherently and interfere with each other leading to a scrambled GW signal, or propagate decoherently and lead to echoes arriving at different times at the observer that could be misidentified as independent GW events. Depending on the type of tensor interaction, the detected GW signal may exhibit amplitude and phase distortions with respect to a GW waveform in GR, as well as birefringence effects. Furthermore, we discuss observational probes of these tensor interactions with both individual GW events, as well as population studies for both ground- and space-based detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

A Strong Limit on the Very-high-energy Emission from GRB 150323A

On 2015 March 23, the Very Energetic Radiation Imaging Telescope Array System (VERITAS) responded to a Swift -Burst Alert Telescope (BAT) detection of a gamma-ray burst, with observations beginning 270 s after the onset of BAT emission, and only 135 s after the main BAT emission peak. No statistically significant signal is detected above 140 GeV. The VERITAS upper limit on the fluence in a 40-minute integration corresponds to about 1% of the prompt fluence. Our limit is particularly significant because the very-high-energy (VHE) observation started only ~2 minutes after the prompt emission peaked, and Fermi -Large Area Telescope observations of numerous other bursts have revealed that the high-energy emission is typically delayed relative to the prompt radiation and lasts significantly longer. Also, the proximity of GRB 150323A ( z = 0.593) limits the attenuation by the extragalactic background light to ~50% at 100–200 GeV. We conclude that GRB 150323A had an intrinsically very weak high-energy afterglow, or that the GeV spectrum had a turnover below ~100 GeV. If the GRB exploded into the stellar wind of a massive progenitor, the VHE non-detection constrains the wind density parameter to be A ≳ 3 × 10 11 g cm -1 , consistent with a standard Wolf–Rayet progenitor. Alternatively, the VHE emission from the blast wave would be weak in a very tenuous medium such as the interstellar medium, which therefore cannot be ruled out as the environment of GRB 150323A.

79 ASTRONOMY AND ASTROPHYSICS↗

Selectivity enhancement in photoacoustic gas analysis via phase-sensitive detection at high modulation frequency

A method for detecting a target fluid in a fluid sample comprising a first fluid and the target fluid using photoacoustic spectroscopy (PAS), comprises a) providing a light source configured to introduce an optical signal having at least one wavelength into the fluid sample; b) modulating the optical signal at a desired modulation frequency such that the optical signal generates an acoustic signal in the fluid sample; c) measuring the acoustic signal in a resonant acoustic detector; and d) using the phase of the acoustic signal to detect the presence of the target fluid.

Kosterev, Anatoliy↗

Method and apparatus for signal processing in a sensor system for use in spectroscopy

A method for processing pulses arriving randomly in time on at least one channel using multiple peak detectors includes asynchronously selecting a non-busy peak detector (PD) in response to a pulse-generated trigger signal, connecting the channel to the selected PD in response to the trigger signal, and detecting a pulse peak amplitude. Amplitude and time of arrival data are output in first-in first-out (FIFO) sequence. An apparatus includes trigger comparators to generate the trigger signal for the pulse-receiving channel, PDs, a switch for connecting the channel to the selected PD, and logic circuitry which maintains the write pointer. Also included, time-to-amplitude converters (TACs) convert time of arrival to analog voltage and an analog multiplexer provides FIFO output. A multi-element sensor system for spectroscopy includes detector elements, channels, trigger comparators, PDs, a switch, and a logic circuit with asynchronous write pointer. The system includes TACs, a multiplexer and analog-to-digital converter.

47 OTHER INSTRUMENTATION↗

Vulnerability Detection Methodology for a Digital Signal Processor Micro-Controller at Edge Level Distributed Energy Resource Controller

Integration of renewable energy and energy storage based Distributed Energy Resource (DER) assets to the grid has seen an upsurge over the past few decades. Traditionally, energy would be generated at a thermal or nuclear power plant and then transmitted over long distance through the transmission grid and then supply to the customers at the distribution grid. Modern renewable energy based DER assets have brought energy production at the edge of distribution grid, which has made the grid vulnerable to cyber intrusion as the power flow controllers for such DER assets are now distributed across the grid from distribution level to transmission level. This paper discusses the vulnerability posed by such power flow controllers of DER assets and demonstrates a detection methodology for unauthorized access and manipulation of system configuration for Digital Signal Processor based Microcontrollers. Experimental results proving efficacy of the methodology have been shown in paper.

Bhowmik, Pankaj↗

SPITZER MID-IR SPECTRA OF DUST DEBRIS AROUND A AND LATE B TYPE STARS: ASTEROID BELT ANALOGS AND POWER-LAW DUST DISTRIBUTIONS

Using the Spitzer/Infrared Spectrograph (IRS) low-resolution modules covering wavelengths from 5 to 35 {mu}m, we observed 52 main-sequence A and late B type stars previously seen using Spitzer/Multiband Imaging Photometer (MIPS) to have excess infrared emission at 24 {mu}m above that expected from the stellar photosphere. The mid-IR excess is confirmed in all cases but two. While prominent spectral features are not evident in any of the spectra, we observed a striking diversity in the overall shape of the spectral energy distributions. Most of the IRS excess spectra are consistent with single-temperature blackbody emission, suggestive of dust located at a single orbital radius-a narrow ring. Assuming the excess emission originates from a population of large blackbody grains, dust temperatures range from 70 to 324 K, with a median of 190 K corresponding to a distance of 10 AU. Thirteen stars however, have dust emission that follows a power-law distribution, F {sub {nu}} = F {sub 0}{lambda}{sup {alpha}}, with exponent {alpha} ranging from 1.0 to 2.9. The warm dust in these systems must span a greater range of orbital locations-an extended disk. All of the stars have also been observed with Spitzer/MIPS at 70 {mu}m, with 27 of the 50 excess sources detected (signal-to-noise ratio > 3). Most 70 {mu}m fluxes are suggestive of a cooler, Kuiper Belt-like component that may be completely independent of the asteroid belt-like warm emission detected at the IRS wavelengths. Fourteen of 37 sources with blackbody-like fits are detected at 70 {mu}m. The 13 objects with IRS excess emission fit by a power-law disk model, however, are all detected at 70 {mu}m (four above, three on, and six below the extrapolated power law), suggesting that the mid-IR IRS emission and far-IR 70 {mu}m emission may be related for these sources. Overall, the observed blackbody and power-law thermal profiles reveal debris distributed in a wide variety of radial structures that do not appear to be correlated with spectral type or stellar age. An additional 43 fainter A and late B type stars without 70 {mu}m photometry were also observed with Spitzer/IRS; results are summarized in Appendix B.

79 ASTRONOMY AND ASTROPHYSICS↗

Trb2, a mouse homolog of tribbles, is dispensable for kidney and mouse development

Glomeruli comprise an important filtering apparatus in the kidney and are derived from the metanephric mesenchyme. A nuclear protein, Sall1, is expressed in this mesenchyme, and we previously reported that Trb2, a mouse homolog of Drosophila tribbles, is expressed in the mesenchyme-derived tissues of the kidney by microarray analyses using Sall1-GFP knock-in mice. In the present report, we detected Trb2 expression in a variety of organs during gestation, including the kidneys, mesonephros, testes, heart, eyes, thymus, blood vessels, muscle, bones, tongue, spinal cord, and ganglions. In the developing kidney, Trb2 signals were detected in podocytes and the prospective mesangium of the glomeruli, as well as in ureteric bud tips. However, Trb2 mutant mice did not display any apparent phenotypes and no proteinuria was observed, indicating normal glomerular functions. These results suggest that Trb2 plays minimal roles during kidney and mouse development.

60 APPLIED LIFE SCIENCES↗

Effect of post annealing on spin accumulation and transport signals in Co{sub 2}FeSi/MgO/n{sup +}-Si on insulator devices

The post annealing temperature dependence of spin accumulation and transport signals in Co{sub 2}FeSi/MgO/n{sup +}-Si on insulator were investigated. The spin signals were detected using 3- and 4-terminal Hanle, 2-terminal local and 4-terminal nonlocal magnetoresistance measurements. The post annealing temperature (T{sub A}) dependence of the magnitude in 3-terminal narrow Hanle signals is nearly constant up to T{sub A} < 400°C, however a slight decrease above T{sub A} ≥ 400°C is observed. This behavior is consistent with the T{sub A} dependence of the magnitude of 4-terminal nonlocal magnetoresistance (MR) signals. The spin polarization estimated from the 3-terminal narrow Hanle signals and the magnitude of 2-terminal local MR signals show a slight improvement with increasing post annealing temperature with a peak at around 325°C and then start reducing slowly. The slight increase in the spin signal would be due to high spin polarization of Co{sub 2}FeSi as a result of structural ordering. The 2-terminal local MR signals do not vary significantly by annealing between as-deposited and T{sub A} = 400°C, indicating the robustness of our device. This result would be useful for future Si spintronics devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Online Detection of Low-Quality Synchrophasor Data Considering Frequency Similarity

Here, this letter proposes a new approach for online detection of low-quality synchrophasor data under both normal and event conditions. The proposed approach utilizes the features of synchrophasor data in time and frequency domains to distinguish multiple regional PMU signals and detect low-quality synchrophasor data. It is more effective to detect low-quality data with apparently indistinguishable profiles. Case studies from recorded synchrophasor measurements verify the effectiveness of the proposed approach for detecting low-quality synchrophasor data in frequency, voltage magnitude and voltage angle.

42 ENGINEERING↗

Nondestructive detection and characterization of carbonation in concrete

Exposure of concrete to the environment leads to changes in composition, microstructure, and properties; these effects often start from the surface of a concrete structure. A specific, widespread environmental effect is carbonation, where carbon dioxide penetrates the surface of concrete and reacts with calcium hydroxide that is a product of Portland cement hydration in concrete. Carbonation is of interest not only because it can lead to the initiation of reinforcement corrosion, but also carbon is increasingly used during curing to alter the surface properties of cement-based materials as a method to 'sink' carbon in cement-based materials. Nonlinear Rayleigh surface wave measurements are performed on uncarbonated and carbonated concrete samples to assess any mechanical changes induced by carbonation,. In order to minimize the effects of contact conditions, the generated signals are detected by a noncontact air-coupled transducer (100 kHz) at locations along the propagation axis. The nonlinearity parameter, β is used to quantitatively characterize the degree of carbonation. To more accurately analyze the data, corrections are made for the effects of attenuation and diffraction. A comparison between the carbonated and uncarbonated samples demonstrates that pores and micro-cracks are affected by the carbonation product and these significantly change the measured nonlinearity parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗