Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Single-crystal based studies for correlating the properties and high-voltage performance of Li[Ni x Mn y Co 1₋x₋y ]O 2 cathodes

Safe and stable cycling of lithium-ion battery cathodes at high voltages is essential for meeting next-generation energy storage demands, yet the lack of fundamental understanding of the correlation of a material's properties and reactivities largely hinders current progress. Here, we demonstrate how single-crystal samples with well-controlled physical characteristics can be used to unambiguously establish the relationships among specific properties, surface chemistry and electrochemical performance, enabling rational design of better performing cathode materials. Layered Li[Ni x Mn y Co 1₋x₋y ]O 2 (NMC) crystals, with four different particle shapes of an octahedron (Oct), truncated octahedron (T-Oct), polyhedron (Poly) and platelet (Plate), were prepared to vary the presence of (104), (001) and (012) family facets on the surface. This represents the first experimental verification of NMC morphologies that were theoretically calculated in the past. Systematic studies on the impact of isolated physical properties reveal the important roles of the Ni content, particle size and facet on surface stability and electrochemical performance. We show that compared to (012) surface dominated samples, high-voltage cycling stability was much improved on the (001) dominated Plate sample, suggesting that replacing the (012) surface with lower energy (001) and/or (104) surfaces can be effective in stabilizing NMCs during high energy applications. Our study moreover provides insights into how tailoring a material's surface properties can be used as an important route in balancing cathode capacity and stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new long-term sampling approach to viruses on surfaces

The importance of virus disease outbreaks and its prevention is of growing public concern but our understanding of virus transmission routes is limited by adequate sampling strategies. While conventional swabbing methods provide merely a microbial snapshot, an ideal sampling strategy would allow reliable collection of viral genomic data over longer time periods. This study has evaluated a new, paper-based sticker approach for collection of reliable viral genomic data over longer time periods up to 14 days and after implementation of different hygiene measures. In contrast to swabbing methods, which sample viral load present on a surface at a given time, the paper-based stickers are attached to the surface area of interest and collect viruses that would have otherwise been transferred onto that surface. The major advantage of one-side adhesive stickers is that they are permanently attachable to a variety of surfaces. Initial results demonstrate that stickers permit stable recovery characteristics, even at low virus titers. Stickers also allow reliable virus detection after implementation of routine hygiene measures and over longer periods up to 14 days. Overall, results for this new sticker approach for virus genomic data collection are encouraging, but further studies are required to confirm anticipated benefits over a range of virus types.

59 BASIC BIOLOGICAL SCIENCES↗

A Balanced Model for Exploration of the Terrestrial Planets: Lessons from the Lunar Experience

The Moon is the only extraterrestrial rocky body for which we have a combination of surface-selected samples, high-resolution orbital photography (Lunar Orbiter), manned and robotic surface exploration (Surveyor, Apollo, Luna), and global compositional, mineralogical, and geophysical data (Galileo, Clementine, Lunar Prospector). Beginning in 1998, CAPTEM organized a series of workshops and conference sessions aimed at integrating these diverse data sets. The insights gained by bringing together scientists from the remote-sensing and sample-analysis communities have been singularly rewarding. Not least of these has been the recognition by both groups that having both kinds of data maximizes the scientific return and permits reconciling information from diverse scales and perspectives. The 20-20 hindsight of the Lunar experience thus provides important lessons; learning from mistakes as well as successes, we can derive a sensible scientific program for Mars exploration. In this abstract, we describe examples of key information from (a) in-situ geologic investigation, (b) laboratory analysis of returned samples whose geologic context and location are known, and (c) global remote sensing of mineralogy, composition, and geophysical parameters. We then show the value of integrating these diverse data sets.

Jolliff, B. L.↗

Sylph - A SmallSat Probe Concept Engineered to Answer Europa's Big Question

Europa, the Galilean satellite second from Jupiter, contains a vast, subsurface ocean of liquid water. Recent observations indicate possible plume activity. If such a plume expels ocean water into space as at Enceladus, a spacecraft could directly sample the ocean by analyzing the plume’s water vapor, ice, and grains. Due to Europa’s strong gravity, such sampling would have to be done within 5 km of the surface to sample ice grains larger than 5 µm, expected to be frozen ocean spray and thus to contain non-volatile species critical to a biosignature-detection mission. By contrast, the planned Europa Multiple Flyby Mission’s closest planned flyby altitude is 25 km. Sylph is a concept for a SmallSat free-flyer probe that, deployed from the planned Europa Mission, would directly sample the large grains by executing a single ~2-km altitude plume pass. The 40-kg probe would be deployed by the Europa mission just before it executes a plume fly-through. Within the probe’s 16-hour lifespan, it would autonomously navigate to perform a parallel, simultaneous pass at the lower altitude. The Sylph flight system design concept combines SmallSat technologies with robust traditional components and advanced manufacturing technologies. Its payload would comprise Mini-SUDA (SUrface Dust Mass Analyzer), a dual-channel, miniature impact ionization mass spectrometer. Sylph represents a novel type of SmallSat concept: purpose-built configuration, optimized for the harsh environment at Europa and for planetary-protection requirements, and hybridized from both mainstream and SmallSat components.

Imken, Travis↗

Quantifying Tip-Sample Interactions in Vacuum Using Cantilever-Based Sensors: An Analysis

Atomic force microscopy is an analytical characterization method that is able to image a sample’s surface topography at high resolution while simultaneously probing a variety of different sample properties. Such properties include tip-sample interactions, the local measurement of which has gained much popularity in recent years. To this end, either the oscillation frequency or the oscillation amplitude and phase of the vibrating force-sensing cantilever are recorded as a function of tip-sample distance and subsequently converted into quantitative values for the force or interaction potential. Here, we theoretically and experimentally show that the force law obtained from such data acquired under vacuum conditions using the most commonly applied methods may deviate more than previously assumed from the actual interaction when the oscillation amplitude of the probe is of the order of the decay length of the force near the surface, which may result in a non-negligible error if correct absolute values are of importance. Caused by approximations made in the development of the mathematical reconstruction procedures, the related inaccuracies can be effectively suppressed by using oscillation amplitudes sufficiently larger than the decay length. To facilitate efficient data acquisition, we propose a technique that includes modulating the drive amplitude at a constant height from the surface while monitoring the oscillation amplitude and phase. Ultimately, such an amplitude-sweep-based force spectroscopy enables shorter data acquisition times and increased accuracy for quantitative chemical characterization compared to standard approaches that vary the tip-sample distance. An additional advantage is that since no feedback loop is active while executing the amplitude sweep, the force can be consistently recovered deep into the repulsive regime.

36 MATERIALS SCIENCE↗

Production of Carbon Nanomaterials and Sorbents from Domestic U.S. Coal (Final Report)

The main goal of this project was to produce high-value carbon nanomaterials and carbon sorbents from domestic coal resources in a cost-effective manner. Four types of domestic coal samples were processed through a combination of deashing, devolatilization, oxidation, reduction, and activation treatments to produce graphene oxide (GO), reduced graphene oxide (RGO), and activated carbon (AC). The precursors and developed materials were extensively characterized by various methods to investigate the impact of the coal feedstock type on the yield and quality of each product. A commercial graphite-based GO sample was included in the experimental work as the baseline material for comparison with the coal-based materials developed in this work. The performed work also included a technoeconomic analysis and cost estimation for a plant processing 20 tons/day coal, a market evaluation for the graphene materials, and a technology gap analysis. A simple process by concentrated nitric acid oxidation is used to oxidize coal precursors for the production of GO. Fine oxidized coal particles that were separated from larger oxidized coal particles had significantly higher oxygen contents and were identified as coal-based GO samples. Coarse oxidized coal particles were used as precursors for production of AC. Based on the Raman spectroscopy results, coal-based GO samples exhibited G and D bands similar to those of graphite-based GO samples. X-ray photoelectron spectroscopy revealed that coal-based GO samples had surface oxygen contents of ~26-35% that were higher than the oxygen contents of graphite-based GO samples. Larger particles of oxidized coal samples were activated under different conditions to produce high surface area functionalized AC. Prepared materials had surface areas exceeding 1,500 m 2 /g and pore volumes more than 1 cm 3 /g with different pore size distributions. Reduced graphene oxide samples were prepared by thermal reduction of both coal-based and graphite-based GO samples at 170-2800 ºC. Coal-based and graphite-based RGO samples exhibited similar carbon contents, Raman spectra, and XRD profiles. Heat treatment above 1500 ºC shifted RGO to synthetic graphite. Among anthracite, bituminous, subbituminous, and lignite coals tested, anthracite was the best precursor to produce carbon nanomaterials exhibiting properties similar to those of graphite-based materials. Anthracite-based carbon nanomaterials also had the highest production yields. Technoeconomic analysis estimated the production cost of GO and RGO for anthracite-based samples at about 2,600 and 4,200 $/ton, respectively, which is about two orders of magnitude lower than the current estimated price of graphite-based materials. Several gaps to further develop the proposed technology were identified and discussed that include process and equipment optimization, process integration, need for additional bench- and pilot-scale experiments, and other items to reduce the scale up risk. Market analysis reports suggested a compound annual growth rate of 40% for graphene and related materials. Short-term applications include composites, inks, and coatings. However, energy storage applications appear to be the dominant potential long-term applications. Different applications of coal-based GO and RGO need to be explored and clear metrics and standards for each application need to be developed.

01 COAL, LIGNITE, AND PEAT↗

Using Remote Sensing Data to Evaluate Surface Soil Properties in Alabama Ultisols

Evaluation of surface soil properties via remote sensing could facilitate soil survey mapping, erosion prediction and allocation of agrochemicals for precision management. The objective of this study was to evaluate the relationship between soil spectral signature and surface soil properties in conventionally managed row crop systems. High-resolution RS data were acquired over bare fields in the Coastal Plain, Appalachian Plateau, and Ridge and Valley provinces of Alabama using the Airborne Terrestrial Applications Sensor multispectral scanner. Soils ranged from sandy Kandiudults to fine textured Rhodudults. Surface soil samples (0-1 cm) were collected from 163 sampling points for soil organic carbon, particle size distribution, and citrate dithionite extractable iron content. Surface roughness, soil water content, and crusting were also measured during sampling. Two methods of analysis were evaluated: 1) multiple linear regression using common spectral band ratios, and 2) partial least squares regression. Our data show that thermal infrared spectra are highly, linearly related to soil organic carbon, sand and clay content. Soil organic carbon content was the most difficult to quantify in these highly weathered systems, where soil organic carbon was generally less than 1.2%. Estimates of sand and clay content were best using partial least squares regression at the Valley site, explaining 42-59% of the variability. In the Coastal Plain, sandy surfaces prone to crusting limited estimates of sand and clay content via partial least squares and regression with common band ratios. Estimates of iron oxide content were a function of mineralogy and best accomplished using specific band ratios, with regression explaining 36-65% of the variability at the Valley and Coastal Plain sites, respectively.

Sullivan, Dana G.↗

Simulation of radar reflectivity and surface measurements of rainfall

Raindrop size distributions (RSDs) are often estimated using surface raindrop sampling devices (e.g., disdrometers) or optical array (2D-PMS) probes. A number of authors have used these measured distributions to compute certain higher-order RSD moments that correspond to radar reflectivity, attenuation, optical extinction, etc. Scatter plots of these RSD moments versus disdrometer-measured rainrates are then used to deduce physical relationships between radar reflectivity, attenuation, etc., which are measured by independent instruments (e.g., radar), and rainrate. In this paper RSDs of the gamma form as well as radar reflectivity (via time series simulation) are simulated to study the correlation structure of radar estimates versus rainrate as opposed to RSD moment estimates versus rainrate. The parameters N0, D0 and m of a gamma distribution are varied over the range normally found in rainfall, as well as varying the device sampling volume. The simulations are used to explain some possible features related to discrepancies which can arise when radar rainfall measurements are compared with surface or aircraft-based sampling devices.

Chandrasekar, V.↗

Characterization of Candidate Materials for Remote Recession Measurements of Ablative Heat Shield Materials

A method of remotely measuring surface recession of a material sample in a plasma flow through emission spectroscopy of the post shock layer was characterized through experiments in the NASA Langley HYMETS arc jet facility. Different methods for delivering the seed products into the Phenolic Impregnated Carbon Ablator (PICA) material samples were investigated. Three samples were produced by seeding the PICA material with combinations of Al, Si, HfO2, VB2, Al2O3, SiO2, TiC, HfC, NaCl, and MgCl2 through infusing seed materials into a core of PICA, or through encapsulating seed material in an epoxy disk, mechanically bonding the disk to a PICA sample. The PICA samples seeded with the candidate tracers were then tested at surface temperatures near 2400 K under low pressure air plasma. The emission of Al, Ti, V, Na, and Mg in the post-shock layer was observed in the UV with a high resolution imaging spectrometer viewing the whole stagnation line from the side, and from UV to NIR with a fiber-coupled miniaturized spectrometer observing the sample surface in the wavelength range from 200 nm to 1,100 nm from the front through a collimator. Al, Na, and Mg were found to be emitting in the post-shock spectra even before the recession reached the seeding depth - therefore possibly characterizing the pyrolysis process rather than the recession itself. The appearance of Ti and V emission in the spectra was well correlated with the actual recession which was monitored through a video of the front surface of the sample. The applicability of a seed material as an indicator for recession appears to be related to the melting temperature of the seed material. Future parametric studies will be carried out in low power plasma facilities at the University of Kentucky.

Butler, Bradley D.↗

Using Remote Sensing Platforms to Estimate Near-Surface Soil Properties

Evaluation of near-surface soil properties via remote sensing (RS) could facilitate soil survey mapping, erosion prediction, fertilization regimes, and allocation of agrochemicals. The objective of this study was to evaluate the relationship between soil spectral signature and near surface soil properties in conventionally managed row crop systems. High resolution RS data were acquired over bare fields in the Coastal Plain, Appalachian Plateau, and Ridge and Valley provinces of Alabama using the Airborne Terrestrial Applications Sensor (ATLAS) multispectral scanner. Soils ranged from sandy Kandiudults to fine textured Rhodudults. Surface soil samples (0-1 cm) were collected from 163 sampling points for soil water content, soil organic carbon (SOC), particle size distribution (PSD), and citrate dithionite extractable iron (Fed) content. Surface roughness, soil water content, and crusting were also measured at sampling. Results showed RS data acquired from lands with less than 4 % surface soil water content best approximated near-surface soil properties at the Coastal Plain site where loamy sand textured surfaces were predominant. Utilizing a combination of band ratios in stepwise regression, Fed (r2 = 0.61), SOC (r2 = 0.36), sand (r2 = 0.52), and clay (r2 = 0.76) were related to RS data at the Coastal Plain site. In contrast, the more clayey Ridge and Valley soils had r-squares of 0.50, 0.36, 0.17, and 0.57. for Fed, SOC, sand and clay, respectively. Use of estimated eEmissivity did not generally improve estimates of near-surface soil attributes.

Sullivan, D. G.↗

Metallic phases in the Luna 24 soil samples

The metal and sulfide phases in the Luna 24 soil samples were studied with the optical microscope and the electron microprobe. The compositions of the metal particles fall into three groups based on their Ni and Co contents: (1) Samples of meteoritic composition which have undergone metamorphism on the lunar surface. (2) Samples of submeteoritic, low Ni and low Co contents, including most of the metal particles observed. These particles are contained in glass and agglutinate particles and were probably formed by the mixing of meteoritic metal with lunar metal produced by the reduction of silicates during shock-impact. (3) Samples of high-CO content probably formed by mixing of meteoritic material with high-Co metal from the mare basalt or by fractional crystallization from a metal silicate melt. The sulfide minerals were also studied. These are almost pure FeS, and crystallized from a late stage liquid in the mare basalt. Three high-Ni sulfides were also found in the glass phase of agglutinates.

Friel, J. J.↗

An Efficient Sampling-Based Method for Sensitivity and Uncertainty Analysis Through RAVEN

Sensitivity analysis (SA) and uncertainty quantification (UQ) are now widely recognized as essential parts of analyses for complex nuclear systems. Plenty of well-established methodologies are already available for performing SA and UQ, such as Monte Carlo analysis, adjoint-based method, and variance decomposition. The focus of this summary is on developing an efficient sampling-based approach to perform SA and UQ through RAVEN. RAVEN (Risk Analysis and Virtual control Environment) is a software framework able to perform SA and UQ, currently under development at the Idaho National Laboratory. In literature, a number of approaches have been developed to accelerate the process of SA and UQ for large complex systems, such as principal component analysis (PCA) of input space, input-output correlation analysis, and intersection subspace methods. The fundamental idea is to identify the dominant active directions in the parameter space prior to conducting SA and UQ. The premise is that the number of active directions is much less than the dimensionality of input space. In this work, the PCA or Karhunen-Loeve expansion or SVD method is implemented in RAVEN to identify the active directions. This approach is also combined with the forward sampling approaches, such as Monte Carlo, Grid, Latin Hypercube, and Response Surface Design sampling approaches that are currently available in RAVEN, to perform SA and UQ more efficiently. The summary is organized as follows. In the following section, we present the PCA-based forward sampling approach. The effectiveness and efficiency are discussed in the numerical results section. The paper then ends with a concluding summary. In this summary, we have presented PCA-based forward sampling approach to perform SA and UQ. The goal is to reduce the computational overhead for repetitive executions of complex nuclear systems that are generally required when performing SA and UQ. The control of correlations between input parameters is implemented in RAVEN to better represent the input relationships. In addition, we are currently examining our implementations with more realistic models, and we are also focusing on implementation of some new high-dimensional input reduction techniques in RAVEN. (authors)

97 MATHEMATICS AND COMPUTING↗

New Material for Surface-Enhanced Raman Spectroscopy

A chemical method of synthesis and application of coating materials that are especially suitable for surface-enhanced Raman spectroscopy (SERS) has been developed. The purpose of this development is to facilitate the utilization of the inherently high sensitivity of SERS to detect chemicals of interest (analytes) in trace amounts, without need for lengthy sample preparation. Up to now, the use of SERS has not become routine because the methods available have not been able to reproduce sampling conditions and provide quantitative measurements. In contrast, the coating materials of the present method enable analysis with minimum preparation of samples, and SERS measurements made using these materials are reproducible and reversible. Moreover, unlike in methods investigated in prior efforts to implement SERS, sampling is not restricted to such specific environments as electrolytes or specific solvents. The coating materials of this method are porous glasses, formed in sol-gel processes, that contain small particles of gold or silver metal. Materials of this type can be applied to the sample-contact surfaces of a variety of sampling and sensing devices, including glass slides, glass vials, fiber-optic probes, and glass tubes. Glass vials with their insides coated according to this method are particularly convenient for SERS to detect trace chemicals in solutions: One simply puts a sample solution containing the analyte(s) into a vial, then puts the vial into a Raman spectrometer for analysis. The chemical ingredients and the physical conditions of the sol-gel process have been selected so that the porous glass formed incorporates particles of the desired metal with size(s) to match the wavelength(s) of the SERS excitation laser in order to optimize the generation of surface plasmons. The ingredients and processing conditions have further been chosen to tailor the porosity and polarity of the glass to optimize the sample flow and the interaction between the analyte(s) and the plasmon field that generates Raman photons. The porous silica network of a sol-gel glass creates a unique environment for stabilizing SERS-active metal particles. Relative to other material structures that could be considered for SERS, the porous silica network offers higher specific surface area and thus greater interaction between analyte molecules and metal particles. Efforts to perform SERS measurements with the help of sampling devices coated by this method have been successful. In tests, numerous organic and inorganic chemicals were analyzed in several solvents, including water. The results of the tests indicate that the SERS measurements were reproducible within 10 percent and linear over five orders of magnitude. One measure of the limits of detectability of chemicals in these tests was found to be a concentration of 300 parts per billion. Further development may eventually make it possible to realize the full potential sensitivity of SERS for detecting some analytes in quantities as small as a single molecule.

Farquharson, Stuart↗

Annual report of groundwater monitoring at Everest, Kansas in 2011

Everest, Kansas, is a small rural community (population approximately 300) located in the southeast corner of Brown County, in the northeastern corner of Kansas. Carbon tetrachloride and chloroform contamination in groundwater at Everest was initially identified in 1997 as a result of testing performed under the Commodity Credit Corporation/U.S. Department of Agriculture (CCC/USDA) private well sampling program conducted by the Kansas Department of Health and Environment (KDHE). The KDHE collected samples from seven private wells in and near Everest. Carbon tetrachloride and chloroform were found in only one of the wells, the Donnie Nigh domestic well (owned at that time by Tim Gale), approximately 3/8 mi northwest of the former Everest CCC/USDA facility. Carbon tetrachloride and chloroform were detected at 121 {mu}g/L and 4 {mu}g/L, respectively. Nitrate was found at 12.62 mg/L. The USDA subsequently connected the Nigh residence to the Everest public water supply system. The findings of the 2011 monitoring at Everest support the following conclusions: (1) Measurements of groundwater levels obtained manually during annual monitoring in 2009-2011 (and through the use of automatic recorders in 2002-2010) have consistently indicated an initial direction of groundwater flow from the former CCC/USDA facility to the north-northwest and toward the Nigh property, then west-southwest from the Nigh property toward the intermittent creek that lies west of the former CCC/USDA facility and the Nigh property. (2) At most of the monitored locations, carbon tetrachloride concentrations decreased in April 2011 relative to 2010 results. Noteworthy decreases of > 50% occurred at locations MW4, MW60, and MW88, in the most concentrated part of the plume. (3) Comparison of accumulated data demonstrates that the area of the carbon tetrachloride plume with concentrations > 200 {mu}g/L has decreased markedly over time and suggests a generally decreasing trend in contaminant levels. (4) The trace increases in carbon tetrachloride concentrations observed in 2010 at locations SB63 and SB64 were notable because of the locations proximity to the downgradient intermittent creek. However, these increases were not confirmed in sampling in 2011. (5) The results of the April 2011 monitoring event continue to support the interpretation, made during the 9-yr observation period from 2001 to 2010, that the migration rate for contamination in groundwater toward the intermittent creek is very slow. (6) No carbon tetrachloride was detected in five samples of surface water collected from the intermittent creek west of the former CCC/USDA facility and the Nigh property, or in tree branch tissue samples collected at locations along the banks of the creek. These observations indicate that the carbon tetrachloride contamination identified at Everest has, to date, not impacted the surface waters of the intermittent creek.

54 ENVIRONMENTAL SCIENCES↗

The Spectrum of Thermally Stimulated Surface Plasmon Polaritons of a Linear Sample

An analytical model of the spectrum of thermally stimulated surface plasmon polaritons (TSSPPs) coming to the edge of a linear conducting sample has been developed. It has been found that the spectrum of such TSSPPs obeys neither the Wien law nor the Stefan–Boltzmann law for thermal radiation. The maximum of this spectrum is shifted to the low-frequency region with respect to the spectrum of the absolutely black body, and the magnitude of the shift is proportional to the sample length. The plasmon nature of the intensity increment of thermal radiation from the edge of a plane face of a duralumin sample has been verified experimentally. It has been shown that the intensity and spectrum of this increment can be controlled both by the sample temperature and by the extension of the face.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sea-ice and surface water circulation, Alaskan continental shelf

The author has identified the following significant results. Over 1500 water samples from surface and from standard hydrographic depths were collected during June and July 1973 from Bering Sea and Gulf of Alaska. The measurement of temperature, salinity, and productivity indicated that various distinct water masses cover the Bering Sea Shelf. The suspended load in surface waters will be correlated with the ERTS-1 imagery as it becomes available to delineate the surface water circulation. The movement of ice floes in the Bering Strait and Bering Sea indicated that movement of ice varies considerably and may depend on wind stress as well as ocean currents.

Wright, F. F.↗

False-Negative Rate and Recovery Efficiency Performance of a Validated Sponge Wipe Sampling Method

Recovery of spores from environmental surfaces varies due to sampling and analysis methods, spore size and characteristics, surface materials, and environmental conditions. Tests were performed to evaluate a new, validated sponge wipe method using Bacillus atrophaeus spores. Testing evaluated the effects of spore concentration and surface material on recovery efficiency (RE), false-negative rate (FNR), limit of detection (LOD), and their uncertainties. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show roughly linear dependences of RE and FNR on surface roughness, with smoother surfaces resulting in higher mean REs and lower FNRs. REs were not influenced by the low spore concentrations tested (3.10x10^-3 to 1.86 CFU/cm^2). Stainless steel had the lowest mean FNR (0.123), and plastic had the highest mean FNR (0.479). The LOD90 (>1 CFU detected 90% of the time) varied with surface material, from 0.015 CFU/cm^2 on stainless steel up to 0.039 on plastic. It may be possible to improve sampling results by considering surface roughness in selecting sampling locations and interpreting spore recovery data. Further, FNR values (calculated as a function of concentration and surface material) can be used presampling to calculate the numbers of samples for statistical sampling plans with desired performance and postsampling to calculate the confidence in characterization and clearance decisions.

Anthrax↗