Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Development of physical and mathematical models for the Porous Ceramic Tube Plant Nutrification System (PCTPNS)

A physical model of the Porous Ceramic Tube Plant Nutrification System (PCTPNS) was developed through microscopic observations of the tube surface under various operational conditions. In addition, a mathematical model of this system was developed which incorporated the effects of the applied suction pressure, surface tension, and gravitational forces as well as the porosity and physical dimensions of the tubes. The flow of liquid through the PCTPNS was thus characterized for non-biological situations. One of the key factors in the verification of these models is the accurate and rapid measurement of the 'wetness' or holding capacity of the ceramic tubes. This study evaluated a thermistor based moisture sensor device and recommendations for future research on alternative sensing devices are proposed. In addition, extensions of the physical and mathematical models to include the effects of plant physiology and growth are also discussed for future research.

Tsao, D. Teh-Wei↗

Quantitative measurements of vaporization, burst ionization, and emission characteristics of shaped charge barium releases

Intensity-calibrated color video recordings of three barium-shaped charge injections in the ionopshere were used to determine the initial ionization, the column density corresponding to unity optical depth, and the yield of vaporized barium in the fast jet. It was found that the initial ionization at the burst was less than 1% and that 0% burst ionization was consistent with the observations. Owing to the Doppler shift, the column density for optical thickness in the neutral barium varies somewhat according to the velocity distribution. For the cases examined here, the column density was 2-5 x 10(exp 10) atoms/sq cm. This value, which occurred 12 to 15 s after release, should be approximately valid for most shaped charge experiments. The yield was near 30% (15% in the fast jet) for two of the releases and was somewhat lower in the third, which also had a lower peak velocity. This study also demonstrated the applicability of the computer simulation code developed for chemical releases by Stenbaek-Nielsen and provided experimental verification of the Doppler-corrected emission rates calculated b Stenbaek-Nielsen (1989).

Hoch, Edward L.↗

Wave Number Selection for Incompressible Parallel Jet Flows Periodic in Space

The temporal instability of a spatially periodic parallel flow of an incompressible inviscid fluid for various jet velocity profiles is studied numerically using Floquet Analysis. The transition matrix at the end of a period is evaluated by direct numerical integration. For verification, a method based on approximating a continuous function by a series of step functions was used. Unstable solutions were found only over a limited range of wave numbers and have a band type structure. The results obtained are analogous to the behavior observed in systems exhibiting complexity at the edge of order and chaos.

Miles, Jeffrey Hilton↗

Development of UV Optical Measurements of Nitric Oxide and Hydroxyl Radical at the Exit of High Pressure Gas Turbine Combustors

Measurements of nitric oxide (NO) and hydroxyl radical (OR) have been made in a laboratory flat flame at pressures up to 30 atm using line-of-sight resonant absorption. Data are reported at equivalence ratios of 0.98 and 1.3 and pressures of 1, 5, 10, 20 and 30 atm. The performance of the in-situ LTV absorption technique with assessed at these elevated pressures by comparing the measured absorption with those predicted by detailed theoretical spectroscopic models for NO and OH. Previous to this experiment the resonant models had not been verified at pressures greater than two atmospheres. Agreement within 25% was found between the measurements and predictions with only slight modification of the existing models for both NO and OH to account for line center shifting and pressure broadening. Continuum interference of hot oxygen (O2) on the NO absorption spectra was not significant in the interpretation of the data. The optical methods used in this study are distinct from laser-based diagnostics such as laser induced fluorescence and, hence, have the potential to provide independent verification of the laser-based measurements. The methodology is also of sufficient simplicity to be hardened into a portable optical measurement system that can be deployed in gas turbine engine test cells. A miniature fiber optic couple portable instrument is described.

Liscinsky, D. S.↗

Implementation of Precision Verification Solvents on the External Tank

This paper presents the Implementation of Precision Verification Solvents on the External Tank. The topics include: 1) Background; 2) Solvent Usages; 3) TCE (Trichloroethylene) Reduction; 4) Solvent Replacement Studies; 5) Implementation; 6) Problems Occuring During Implementation; and 7) Future Work. This paper is presented in viewgraph form.

Campbell, M.↗

Sliding Mode Control of a Slewing Flexible Beam

An output feedback sliding mode controller (SMC) is proposed to minimize the effects of vibrations of slewing flexible manipulators. A spline trajectory is used to generate ideal position and velocity commands. Constrained nonlinear optimization techniques are used to both calibrate nonlinear models and determine optimized gains to produce a rest-to-rest, residual vibration-free maneuver. Vibration-free maneuvers are important for current and future NASA space missions. This study required the development of the nonlinear dynamic system equations of motion; robust control law design; numerical implementation; system identification; and verification using the Sandia National Laboratories flexible robot testbed. Results are shown for a slewing flexible beam.

Wilson, David G.↗

Assessment of Human Factors

Human Factors Engineering, often referred to as Ergonomics, is a science that applies a detailed understanding of human characteristics, capabilities, and limitations to the design, evaluation, and operation of environments, tools, and systems for work and daily living. Human Factors is the investigation, design, and evaluation of equipment, techniques, procedures, facilities, and human interfaces, and encompasses all aspects of human activity from manual labor to mental processing and leisure time enjoyments. In spaceflight applications, human factors engineering seeks to: (1) ensure that a task can be accomplished, (2) maintain productivity during spaceflight, and (3) ensure the habitability of the pressurized living areas. DSO 904 served as a vehicle for the verification and elucidation of human factors principles and tools in the microgravity environment. Over six flights, twelve topics were investigated. This study documented the strengths and limitations of human operators in a complex, multifaceted, and unique environment. By focusing on the man-machine interface in space flight activities, it was determined which designs allow astronauts to be optimally productive during valuable and costly space flights. Among the most promising areas of inquiry were procedures, tools, habitat, environmental conditions, tasking, work load, flexibility, and individual control over work.

Mount, Frances↗

Verification of the Solar Dynamics Observatory High Gain Antenna Pointing Algorithm Using Flight Data

The Solar Dynamics Observatory (SDO), launched in 2010, is a NASA-designed spacecraft built to study the Sun. SDO has tight pointing requirements and instruments that are sensitive to spacecraft jitter. Two High Gain Antennas (HGAs) are used to continuously send science data to a dedicated ground station. Preflight analysis showed that jitter resulting from motion of the HGAs was a cause for concern. Three jitter mitigation techniques were developed and implemented to overcome effects of jitter from different sources. These mitigation techniques include: the random step delay, stagger stepping, and the No Step Request (NSR). During the commissioning phase of the mission, a jitter test was performed onboard the spacecraft, in which various sources of jitter were examined to determine their level of effect on the instruments. During the HGA portion of the test, the jitter amplitudes from the single step of a gimbal were examined, as well as the amplitudes due to the execution of various gimbal rates. The jitter levels were compared with the gimbal jitter allocations for each instrument. The decision was made to consider implementing two of the jitter mitigating techniques on board the spacecraft: stagger stepping and the NSR. Flight data with and without jitter mitigation enabled was examined, and it is shown in this paper that HGA tracking is not negatively impacted with the addition of the jitter mitigation techniques. Additionally, the individual gimbal steps were examined, and it was confirmed that the stagger stepping and NSRs worked as designed. An Image Quality Test was performed to determine the amount of cumulative jitter from the reaction wheels, HGAs, and instruments during various combinations of typical operations. The HGA-induced jitter on the instruments is well within the jitter requirement when the stagger step and NSR mitigation options are enabled.

Bourkland, Kristin L.↗

Advances in Rodent Research Missions on the International Space Station

A Research platform for rodent experiment on the ISS is an essential tool for advancing biomedical research in space. The Rodent Research allows for experiments of much longer duration that experiments on the Shuttle. NASA’s Rodent Research (RR)-1 mission was successfully completed, including post-flight analysis and achieved a number of objectives including validation of flight hardware, on-orbit operations, and science capabilities that were developed at the NASA Ames Research Center. Briefly, twenty C57BL/6J adult female mice were launched on the SpX4 Dragon vehicle, which thrived for up to 37 days in microgravity. Daily health checks of the mice were performed during the mission via downlinked video; all animals were healthy and displayed normal behavior without any significant signs of stress. Behavioral analysis demonstrated that Flight and Ground Control mice exhibited the same range of behaviors, including eating, drinking, exploratory behavior, self- and allo-grooming, and social interactions indicative of healthy animals. The animals were euthanized and select tissues were collected from some of the mice on orbit to assess the long-term sample storage capabilities of the ISS. The data obtained from the flight mice were comparable to those from the 3 groups of control mice (baseline, vivarium and ground controls), suggesting that the ISS has adequate capability to support long-duration rodent experimentations. We recovered over 35 tissues from 40 RR1 frozen carcasses, yielded over 3200 aliquots of tissues, and distributed to the scientific community, including NASA’s GeneLab and scientists in the U.S. through Biospecimen Sharing Program via Ames Life Science Data Archive. Tissues were also distributed to Russian research colleagues at the Institute for Biomedical Problems. The expression levels of select genes including albumin, catalase, GAPDH, HMGCoA Reductase, and IGF1 were determined using RNA isolated from the livers by qPCR and no significant differences by one factor ANOVA were found between flight and ground control groups. In addition, some of the liver samples were subject to transcriptomics, epigenomics and proteomics. The data are now available to the scientific community through GeneLab’s open science data website. Since the RR1 mission, another long duration mission (Rodent Research-2) was completed on the ISS in 2015 in which 20 female C57 BL/6J mice were successfully maintained on the ISS for varying time points, with the last group of 5 animals being on-orbit for 54 days. This second Rodent Research flight expanded the program’s capabilities with the introduction of new technologies including blood collection and separation and bone densitometry scanning. Furthermore, we have continued to expand the ISS’s capabilities by running a series of ground-based verification testing using male mice. Our next step is to fly male mice for Rodent Research-4 on SpaceX-10 to study the effects of microgravity on bone healing and regeneration. It will be the first long-duration mission using male mice using Rodent Hardware. In addition, the number of mice will increase from 20 mice (on RR-1 and RR-2) to 40 for RR-4. When samples return to Earth, a number of tissues will be dissected from the frozen carcasses and select tissue samples will become available to the scientific community via BSP. Altogether, we have continued to expand our capabilities for performing long-duration missions on the ISS as emphasized in the National Research Council’s Decadal Survey released in 2011 and to maximize science return from each mission.

Choi, S.↗

An Overview of Distributed Spacecraft Autonomy at NASA Ames

Autonomous decision-making significantly increases mission effectiveness by mitigating the effects of communication constraints, like latency and bandwidth, and mission complexity on multi-spacecraft operations. To advance the state of the art in autonomous Distributed Space Systems (DSS), the Distributed Spacecraft Autonomy (DSA) team at NASA's Ames Research Center is developing within five relevant technical areas: distributed resource and task management, reactive operations, system modeling and simulation, human-swarm interaction, and ad hoc network communications. DSA is maturing these technologies - critical for future large autonomous DSS - from concept to launch via simulation studies and orbital deployments. A 100-node heterogenous Processor-in-the-Loop (PiL) testbed aids distributed autonomy capability development and verification of multi-spacecraft missions. The DSA software payload deployed to the D-Orbit SCV-004 spacecraft demonstrates multi-agent reconfigurability and reliability as part of an ESA-sponsored in-orbit technology demonstration. Finally, DSA's primary flight mission showcases collaborative resource allocation for multipoint science data collection with four small spacecraft as a payload on NASA's Starling 1.0 satellites.

Caleb Ashmore Adams↗

Fiber Optic Tamper Indicating Enclosure (TIE); A Case Study in Authentication

A robust fiber optic-based tamper-indicating enclosure (TIE) has been developed by PNNL through funding by the National Nuclear Security Administration Office of Nuclear Verification over the past few years. The objective of this work is to allow monitors to have confidence in both the authenticity and integrity of the TIE and the monitoring equipment inside, throughout the time it may be located at a host facility. Incorporating authentication features into the design were the focus of fiscal year 2014 development efforts. Throughout the development process, modifications have been made to the physical TIE design based on lessons learned via exercises and expert elicitation. The end result is a robust and passive TIE which can be utilized to protect monitoring party equipment left in a host facility.

Arms Control↗

Assessing the Predictive Capability of the LIFEIV Nuclear Fuel Performance Code Using Sequential Calibration

This report considers the problem of calibrating a numerical model to data from an experimental campaign (or series of experimental tests). The issue is that when an experimental campaign is proposed, only the input parameters associated with each experiment are known (i.e. outputs are not known because the experiments have yet to be conducted). Faced with such a situation, it would be beneficial from the standpoint of resource management to carefully consider the sequence in which the experiments are conducted. In this way, the resources available for experimental tests may be allocated in a way that best 'informs' the calibration of the numerical model. To address this concern, the authors propose decomposing the input design space of the experimental campaign into its principal components. Subsequently, the utility (to be explained) of each experimental test to the principal components of the input design space is used to formulate the sequence in which the experimental tests will be used for model calibration purposes. The results reported herein build on those presented and discussed in [1,2] wherein Verification & Validation and Uncertainty Quantification (VU) capabilities were applied to the nuclear fuel performance code LIFEIV. In addition to the raw results from the sequential calibration studies derived from the above, a description of the data within the context of the Predictive Maturity Index (PMI) will also be provided. The PMI [3,4] is a metric initiated and developed at Los Alamos National Laboratory to quantitatively describe the ability of a numerical model to make predictions in the absence of experimental data, where it is noted that 'predictions in the absence of experimental data' is not synonymous with extrapolation. This simply reflects the fact that resources do not exist such that each and every execution of the numerical model can be compared against experimental data. If such resources existed, the justification for numerical models would be reduced considerably. The authors note that the PMI is primarily intended to provide a high-level, quantitative description of year-to-year (or version-to-version) improvements in numerical models, where these descriptions can be used as a means of justifying funding requests to support further model development research. It is in this context that the present report should be considered: the availability of data from experimental tests should be viewed as a time-dependent variable, where experiments are added to the calibration suite as resources become available. For the present report, the experimental data is of course already available (permitting demonstration of the proposed methodology). Furthermore, the authors are not proposing this methodology as the answer to the question of how to allocate resources for experimental tests, and readers are directed to [5] and the references contained in Section 1 of [5] for additional information on the subject. However, the strength of this methodology is that it offers a means by which to select the sequence of experiments in a pre-arranged experimental campaign (a situation for which the methods discussed in [5] are less appropriate). The report is organized as follows. Section 2 describes the methodology employed to formulate the sequences of experiments for the calibrations performed for this study. Section 3 then presents the results associated with two sequences; supplementary results are provided in the Appendix. The report then concludes in Section 4 with a brief summary.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-376: 3-D Commissioning for An Image-Guided Small Animal Micro- Irradiation Platform

Purpose: A 3-D radiochromic plastic dosimeter has been used to cross-test the isocentricity of a high resolution image-guided small animal microirradiation platform. In this platform, the mouse stage rotating for cone beam CT imaging is perpendicular to the gantry rotation for sub-millimeter radiation delivery. A 3-D dosimeter can be used to verify both imaging and irradiation coordinates. Methods: A 3-D dosimeter and optical CT scanner were used in this study. In the platform, both mouse stage and gantry can rotate 360° with rotation axis perpendicular to each other. Isocentricity and coincidence of mouse stage and gantry rotations were evaluated using star patterns. A 3-D dosimeter was placed on mouse stage with center at platform isocenter approximately. For CBCT isocentricity, with gantry moved to 90°, the mouse stage rotated horizontally while the x-ray was delivered to the dosimeter at certain angles. For irradiation isocentricity, the gantry rotated 360° to deliver beams to the dosimeter at certain angles for star patterns. The uncertainties and agreement of both CBCT and irradiation isocenters can be determined from the star patterns. Both procedures were repeated 3 times using 3 dosimeters to determine short-term reproducibility. Finally, dosimeters were scanned using optical CT scanner to obtain the results. Results: The gantry isocentricity is 0.9 ± 0.1 mm and mouse stage rotation isocentricity is about 0.91 ± 0.11 mm. Agreement between the measured isocenters of irradiation and imaging coordinates was determined. The short-term reproducibility test yielded 0.5 ± 0.1 mm between the imaging isocenter and the irradiation isocenter, with a maximum displacement of 0.7 ± 0.1 mm. Conclusion: The 3-D dosimeter can be very useful in precise verification of targeting for a small animal irradiation research. In addition, a single 3-D dosimeter can provide information in both geometric and dosimetric uncertainty, which is crucial for translational studies.

60 APPLIED LIFE SCIENCES↗

Analysis of Harrell Monosodium Titanate Lot #081811

Monosodium titanate (MST) for use in the Actinide Removal Process (ARP) must be qualified and verified in advance. A single qualification sample for each batch of material is sent to SRNL for analysis, as well as a statistical sampling of verification samples. The Harrell Industries Lot No.081811 qualification and 12 verification samples met all the requirements in the specification, with the possible exception of the geometric standard deviation for particle size. Two subsamples from the qualification sample were analyzed, giving results of 3.82 and 3.28, respectively, for the geometric standard deviation. The specification is {le}3.5. The results for both samples met the remaining particle size specifications, i.e. <10 vol% below 0.8 {mu}m and <1 vol% above 37 {mu}m. Filtration behavior of the current batch is expected to be near that of recent batches. SRNL recommends acceptance of this material. SRNL also recommends performing a statistical review of particle size data for the MST lots from this vendor to assess whether an improved material specification is appropriate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutronics Modeling of the pulsed plasma rocket reactor using rattlesnake

In the pulsed plasma rocket (PPR) reactor, neutron induced fission processes are utilized to implement a series of pulsed micro-explosions of very high power and eject plasma as a propellant. More specifically, projectiles (bullets) composed of moderated uranium are sent through the chamber of an unmoderated uranium barrel. By inducing rapid fission within the bullets, a plasma can be generated with appropriate delivery of neutrons. This study aims to assess the neutronics performance of the PPR reactor during normal operations using the MOOSE-based Rattlesnake code through the evaluation of the impact of the movement of the fuel bullet and the rotation of control drums on the criticality of the system. The Monte Carlo (MC) code Serpent 2 was employed to generate material-based cross sections for use in Rattlesnake and the reference neutronics solution. Cubit was used to generate the mesh for the Rattlesnake model. Parametric studies were conducted to evaluate the best approaches for cross section and mesh generation to ensure accurate results from Rattlesnake. As part of the verification process, the eigenvalue results of the system at various fuel bullet positions were obtained using Rattlesnake and compared with the reference solutions. The acceptable differences show that the Rattlesnake model with appropriate cross section and mesh generation procedure is a sufficiently accurate approximation of the continuous energy (CE) MC model for micro-sized reactors like the PPR reactor. Next, the impact of the rotation of the control drums on the system criticality was evaluated using the verified model. It was shown that the high-fidelity simulation using the deterministic code Rattlesnake can produce sufficiently accurate results for the evaluation of the reactor's neutronics performance in different phases of the normal operation with acceptable computational cost.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CALIBRATED ULTRA FAST IMAGE SIMULATIONS FOR THE DARK ENERGY SURVEY

Image simulations are becoming increasingly important in understanding the measurement process of the shapes of galaxies for weak lensing and the associated systematic effects. For this purpose we present the first implementation of the Monte Carlo Control Loops (MCCL), a coherent framework for studying systematic effects in weak lensing. It allows us to model and calibrate the shear measurement process using image simulations from the Ultra Fast Image Generator (UFig) and the image analysis software SExtractor. We apply this framework to a subset of the data taken during the Science Verification period (SV) of the Dark Energy Survey (DES). We calibrate the UFig simulations to be statistically consistent with one of the SV images, which covers ∼0.5 square degrees. We then perform tolerance analyses by perturbing six simulation parameters and study their impact on the shear measurement at the one-point level. This allows us to determine the relative importance of different parameters. For spatially constant systematic errors and point-spread function, the calibration of the simulation reaches the weak lensing precision needed for the DES SV survey area. Furthermore, we find a sensitivity of the shear measurement to the intrinsic ellipticity distribution, and an interplay between the magnitude-size and the pixel value diagnostics in constraining the noise model. This work is the first application of the MCCL framework to data and shows how it can be used to methodically study the impact of systematics on the cosmic shear measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification

Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was used for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Benchmark On Sensitivity Calculation (Phase III)

The sensitivities of the keff eigenvalue to neutron cross sections have become commonly used in similarity studies and as part of the validation algorithm for criticality safety assessments. To test calculations of the sensitivity coefficients, a benchmark study (Phase III) has been established by the OECD-NEA/WPNCS/EG UACSA (Expert Group on Uncertainty Analysis for Criticality Safety Assessment). This paper presents some sensitivity results generated by the benchmark participants using various computational tools based upon different computational methods: SCALE/TSUNAMI-3D and -1D, MONK, APOLLO2-MORET 5, DRAGON-SUSD3D and MMKKENO. The study demonstrates the performance of the tools. It also illustrates how model simplifications impact the sensitivity results and demonstrates the importance of 'implicit' (self-shielding) sensitivities. This work has been a useful step towards verification of the existing and developed sensitivity analysis methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗