Voitenko experiments with novel diagnostics detect velocities of 89 km/s
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
In order to reveal the physical processes taking place within the ''{mu}10'' microwave discharge ion thruster, internal plasma diagnosis is indispensable. However, the ability of metallic probes to access microwave plasmas biased at a high voltage is limited from the standpoints of the disturbance created in the electric field and electrical isolation. In this study, the axial density profiles of excited neutral xenon were successfully measured under ion beam acceleration by using a novel laser absorption spectroscopy system. The target of the measurement was metastable Xe I 5p{sup 5}({sup 2}P{sup 0}{sub 3/2})6s[{sup 3}/{sub 2}]{sup 0}{sub 2} which absorbed a wavelength of 823.16 nm. Signals from laser absorption spectroscopy that swept a single-mode optical fiber probe along the line of sight were differentiated and converted into axial number densities of the metastable neutral particles in the plasma source. These measurements revealed a 10{sup 18} m{sup -3} order of metastable neutral particles situated in the waveguide, which caused two different modes during the operation of the {mu}10 thruster. This paper reports a novel spectroscopic measurement system with axial resolution for microwave plasma sources utilizing optical fiber probes.
Time-gated radiography with monoenergetic 15-MeV protons, 3-MeV protons, and 4-MeV alpha particles has revealed a rich and complex evolution of electromagnetic field structures in and around imploding, directly driven inertial-confinement fusion (ICF) targets at the OMEGA laser facility. Plastic-shell capsules and solid plastic spheres were imaged during and after irradiation with ICF-relevant laser drive (up to 6 x 10{sup 14} W/cm{sup 2}). Radial filaments appeared while the laser was on; they filled, and were frozen into, the out-flowing corona, persisting until well after the end of the laser drive. Data from specially designed experiments indicate that the filaments were not generated by two-plasmon-decay instabilities or by Rayleigh-Taylor instabilities associated with shell acceleration. Before the onset of visible filamentation, quasi-spherical field structures appeared outside the capsule in the images in a form that suggests outgoing shells of net positive charge. We conjecture that these discrete shells are related to multiple peaks seen previously in the spectra of protons ablated from the targets.
We have developed and demonstrated a versatile, compact electron source that can produce a mono-energetic electron beam up to 50 mm in diameter from 0.1 to 30 keV with an energy spread of <10 eV. By illuminating a metal cathode plate with a single near ultraviolet light emitting diode, a spatially uniform electron beam with 15% variation over 1 cm{sup 2} can be generated. A uniform electric field in front of the cathode surface accelerates the electrons into a beam with an angular divergence of <1 Degree-Sign at 1 keV. The beam intensity can be controlled from 10 to 10{sup 9} electrons cm{sup -2} s{sup -1}.
Experiments at the HERCULES laser facility have produced directional neutron beams with energies up to 16.8({+-}0.3) MeV using {sub 1}{sup 2}d(d,n){sub 2}{sup 3}He,{sub 7}{sup 3}Li(p,n){sub 4}{sup 7}Be,and{sub 3}{sup 7}Li(d,n){sub 4}{sup 8}Be reactions. Efficient {sub 1}{sup 2}Li(d,n){sub 4}{sup 8}Be reactions required the selective acceleration of deuterons through the introduction of a deuterated plastic or cryogenically frozen D{sub 2}O layer on the surface of a thin film target. The measured neutron yield was {<=}1.0 ({+-}0.5) Multiplication-Sign 10{sup 7} neutrons/sr with a flux 6.2({+-}3.7) times higher in the forward direction than at 90{sup Degree-Sign }. This demonstrates that femtosecond lasers are capable of providing a time averaged neutron flux equivalent to commercial {sub 1}{sup 2}d(d,n){sub 2}{sup 3}He generators with the advantage of a directional beam with picosecond bunch duration.
Previous works on reconstructing the 4D phase space using tomography require optimal selection of projection views to achieve accurate reconstruction. In 2D reconstruction, the process is straightforward, as an object can be evenly sampled by dividing the angles evenly. However, extending this concept from 2D to 4D is not intuitive. This work demonstrates that quaternions can be used to more effectively describe views in 4D and introduces the Fibonacci Flower algorithm and repulsive force algorithm to evenly space views in 4D space in order to achieve higher reconstruction accuracy.
Plasma thrusters have been operated at power levels from 10kW to 0.1MW. When these devices have had magnetic fields applied to them which form a nozzle configuration for the expanding plasma, they have shown marked increases in exhaust velocity which is in direct proportion to the magnitude of the applied field. Further, recent results have shown that electrode erosion may be influenced by applied magnetic fields. This research is directed to the experimental and computational study of the effects of applied magnetic field nozzles in the acceleration of plasma flows. Plasma source devices which eliminate the plasma interaction in normal thrusters are studied as most basic. Normal thruster configurations will be studied without applied fields and with applied magnetic nozzle fields. Unique computational studies will utilize existing codes which accurately include transport processes. Unique diagnostic studies will support the experimental studies to generate new data. Both computation and diagnostics will be combined to indicate the physical mechanisms and transport properties that are operative in order to allow scaling and accurate prediction of thruster performance.
A visually-based deictic primative used as an elementary command set for general purpose navigation was investigated. It was shown that a simple 'follow your eyes' scenario is sufficient for tracking a moving target. Limitations of velocity, acceleration, and modeling of the response of the mechanical systems were enforced. Realistic paths of the robots were produced during the simulation. Scientists could remotely command a planetary rover to go to a particular rock formation that may be interesting. Similarly an expert at plant maintenance could obtain diagnostic information remotely by using deictic primitives on a mobile are used in the deictic primitives, we could imagine that the exact same control software could be used for all of these applications.
An electronic communication-and-control system has been developed as a prototype of advanced means of automatically modifying the switching of traffic lights to give priority to emergency vehicles. This system could be used alternatively or in addition to other emergency traffic-light-preemption systems, including a variety of systems now in use as well as two proposed systems described in "Systems Would Preempt Traffic Lights for Emergency Vehicles" (NPO-30573), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 36. Unlike those prior systems that depend on detection of sounds and/or lights emitted by emergency vehicles, this system is not subject to severe range limitations. This system can be retrofitted into any pre-existing traffic-light-control system, without need to modify that system other than to make a minimal number of wire connections between the two systems. This system comprises several subsystems, including a transponder and interface circuitry on each emergency vehicle, a monitoring and control unit at each intersection equipped with traffic lights, and a wide-area two-way radio communication network that connects the emergency vehicles and intersection units. Computers in the various intersections and vehicle units run special-purpose software that implements the traffic- light-preemption scheme. The operations of the intersection and vehicle units are synchronized by use of Global Positioning System (GPS) timing signals. The transponder in each vehicle estimates its own position and velocity by use of GPS signals, deductive ("dead") reckoning, data from the onboard diagnostic (OBD) computer of the vehicle, and/or triangulation of beacon signals. When the operator of an emergency vehicle turns on its flashing lights and sirens in response to a request for an emergency response, the transponder unit goes into action, reading the OBD data to determine speed and acceleration, and reading and gathering further navigational data as described above. The position, velocity, and acceleration data are combined with vehicle-identification data in a prescribed format, and the resulting set of data is transmitted to the intersections within communication range of the transponder.
One of the biggest challenges in understanding magnetohydrodynamic (MHD) turbulence is identifying the plasma mode components from observational data. Previous studies on synchrotron polarization from the interstellar medium (ISM) suggest that the dominant MHD modes can be identified via statistics of Stokes parameters, which would be crucial for studying various ISM processes such as the scattering and acceleration of cosmic rays, star formation, and dynamo. In this paper, we present a numerical study of the synchrotron polarization analysis (SPA) method through systematic investigation of the statistical properties of the Stokes parameters. We derive the theoretical basis for our method from the fundamental statistics of MHD turbulence, recognizing that the projection of the MHD modes allows us to identify the modes dominating the energy fraction from synchrotron observations. Based on the discovery, we revise the SPA method using synthetic synchrotron polarization observations obtained from 3D ideal MHD simulations with a wide range of plasma parameters and driving mechanisms, and present a modified recipe for mode identification. We propose a classification criterion based on a new SPA+ fitting procedure, which allows us to distinguish between Alfvén mode and compressible/slow mode dominated turbulence. We further propose a new method to identify fast modes by analyzing the asymmetry of the SPA+ signature and establish a new asymmetry parameter to detect the presence of fast mode turbulence. Additionally, we confirm through numerical tests that the identification of the compressible and fast modes is not affected by Faraday rotation in both the emitting plasma and the foreground.
Future accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. Coherent synchrotron radiation (CSR) in the dipoles could limit the performance of the emittance exchanger. In this paper, we report the experimental studies on measuring CSR and its effects on the beam at the A0 photoinjector in the emittance exchange line. After reporting the CSR power measurements, we report on the diagnostic scheme based on a weak skew quad in the emittance exchange line to study the CSR effects on the beam and other beam dynamics. In this work, we have reported on CSR measurements and the effect of skew quad on the dogleg line with the 5-cell turned on and off. We plan to study CSR effects on the bunch with the 5-cell on at larger chirp. This is will not only increase the CSR self-effect but also reduce the beamsize at the screen for convenient beamsize measurements.
SLAC National Accelerator Laboratory has built and is currently operating a first generation prototype Marx klystron modulator to meet ILC specifications. Under development is a second generation prototype, aimed at improving overall performance, serviceability, and manufacturability as compared to its predecessor. It is designed around 32 cells, each operating at 3.75 kV and correcting for its own capacitor droop. Due to the uniqueness of this application, high voltage gate drivers needed to be developed for the main 6.5 kV and droop correction 1.7 kV IGBTs. The gate driver provides vital functions such as protection of the IGBT from over-voltage and over-current, detection of gate-emitter open and short circuit conditions, and monitoring of IGBT degradation (based on collector-emitter saturation voltage). Gate drive control, diagnostic processing capabilities, and communication are digitally implemented using an FPGA. This paper details the design of the gate driver circuitry, component selection, and construction layout. In addition, experimental results are included to illustrate the effectiveness of the protection circuit.
Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.
Modifications have been implemented in the Penning-Malmberg device ELTRAP aimed at performing studies on the dynamics of space-charge dominated nanosecond electron bunches traveling along the magnetic field. In particular, a Thomson backscattering apparatus has been developed where an infrared (IR) laser pulse collides with the bunched electron beam. The frequency-shifted backscattered radiation, acquired by means of a photomultiplier (PMT), can be exploited to evaluate information on energy, energy spread and density of the bunch. The achievable sensitivity of the diagnostics has been estimated, and valuable information on the main parameters affecting the signal-to-noise (S/N) ratio has been obtained [B. Paroli, F. Cavaliere, M. Cavenago, F. De Luca, M. Ikram, G. Maero, C. Marini, R. Pozzoli, and M. Rome, JINST 7, P01008 (2012)]. A series of upgrades are under way, aimed at increasing the S/N ratio through the use of a new laser for the electron source, the insertion of a stray light shield, and the optimization of the detection electronics. Moreover, electromagnetic simulations relevant to the design and implementation of a microwave heating system are presented. The generation of an electron plasma in ELTRAP by means of a low-power radio frequency (RF) drive in the MHz range applied on one of the trap electrodes and under ultra-high vacuum (UHV) conditions has previously been demonstrated [B. Paroli, F. De Luca, G. Maero, F. Pozzoli, and M. Rome, Plasma Sources Sci. Technol. 19, 045013 (2010)]. The new heating system will allow the extension of the RF studies to the GHz range and in particular the production of a more energetic electron plasma via cyclotron resonant excitation.
Here, we consider the constraints from Supernova 1987A on particles with small couplings to the Standard Model. We discuss a model with a fermion coupled to a dark photon, with various mass relations in the dark sector; millicharged particles; dark-sector fermions with inelastic transitions; the hadronic QCD axion; and an axion-like particle that couples to Standard Model fermions with couplings proportional to their mass. In the fermion cases, we develop a new diagnostic for assessing when such a particle is trapped at large mixing angles. Our bounds for a fermion coupled to a dark photon constrain small couplings and masses ≲ 200 MeV, and do not decouple for low fermion masses. They exclude parameter space that is otherwise unconstrained by existing accelerator-based and direct-detection searches. In addition, our bounds are complementary to proposed laboratory searches for sub-GeV dark matter, and do not constrain several benchmark-model targets in parameter space for which the dark matter obtains the correct relic abundance from interactions with the Standard Model. For a millicharged particle, we exclude charges between 10 –9 –few×10 –6 in units of the electron charge, also for masses ≲ 200 MeV; this excludes parameter space to higher millicharges and masses than previous bounds. For the QCD axion and an axion-like particle, we apply several updated nuclear physics calculations and include the energy dependence of the optical depth to accurately account for energy loss at large couplings. These corrections allow us to rule out a hadronic axion of mass between 0.1 and a few hundred eV, or equivalently to put a bound on the scale of Peccei-Quinn symmetry breaking between a few×10 4 and 10 8 GeV, closing the hadronic axion window. For an axion-like particle, our bounds disfavor decay constants between a few×10 5 GeV up to a few×10 8 GeV, for a mass ≲ 200 MeV. In all cases, our bounds differ from previous work by more than an order of magnitude across the entire parameter space. We also provide estimated systematic errors due to the uncertainties of the progenitor.
Purpose: Accelerated partial breast irradiation (APBI) after breast-conserving therapy is currently under investigation in prospective randomized studies. Multifocality and multicentricity are exclusion criteria for APBI. Preoperative breast magnetic resonance imaging (MRI) can detect ipsilateral and contralateral invasive tumor foci or ductal carcinoma in situ in addition to conventional diagnostic methods (clinical examination, mammography, and ultrasonography). The objective of this retrospective study was to evaluate the impact of preoperative MRI on patient selection for APBI. Methods and Materials: From 2002 to 2007, a total of 579 consecutive, nonselected patients with newly diagnosed early-stage breast cancer received preoperative breast MRI in addition to conventional imaging studies at the Bonn University Breast Cancer Center. In retrospect, 113 patients would have met the criteria for APBI using conventional imaging workup (clinical tumor size {<=}3 cm; negative axillary lymph node status; unifocal disease; no evidence of distant metastases; no invasive lobular carcinoma, ductal and lobular carcinoma in situ, or Paget's disease). We analyzed the amount of additional ipsilateral and contralateral tumor foci detected by MRI. Results: MRI detected additional tumor foci in 8.8% of patients eligible for APBI (11 tumor foci in 10 of 113 patients), either ipsilateral (n = 7, 6.2%) or contralateral (n = 4, 3.5%). In 1 patient, MRI helped detect additional tumor focus both ipsilaterally and contralaterally. Conclusions: Preoperative breast MRI is able to identify additional tumor foci in a clinically relevant number of cases in this highly selected group of patients with low-risk disease and may be useful in selecting patients for APBI.
The continued emergence of pathogens, whether novel, re-emerging, or engineered, poses a persistent global biosecurity and public health challenge. Recent outbreaks, including COVID-19, Lassa fever, Marburg virus, mpox, and avian influenza, underscore the urgent need for robust systems that enable rapid surveillance, early diagnosis, and timely countermeasures before widespread human transmission occurs. In this article, we focus on early detection technologies and systematically evaluate current diagnostic and sensing modalities. We highlight sequencing and spectroscopy as two complementary approaches capable of providing broad, agnostic detection and rich biological insight. Our analysis emphasizes that scientific innovation alone is insufficient: effective preparedness also requires improved data curation, integration, and sharing to build AI-ready resources that accelerate future responses. We argue for coordinated advances in both technological capabilities and supporting infrastructure to enable the rapid identification and characterization of emerging pathogens and to fully leverage modern science against evolving infectious threats.
Development of robust instrumentation has shown evidence for a multi-μC expulsion of relativistic electrons from a sub-μm-thick foil, laser illuminated with 60–70 J on target at 2 × 10 20 W/cm 2 . From previous work and with electron spectroscopy, it is seen that an exponential electron energy distribution is accurate enough to calculate the emitted electron charge and energy content. The 5–10- μ C charge for the >100-TW Trident Laser represents the first active measurement of the >50% laser-light-to-electron conversion efficiency. By shorting out the TV/m electric field usually associated with accelerating multi-MeV ions from such targets, one finds that this charge is representative of a multi-MA current of relativistic electrons for diverse applications from electron fast ignition to advanced radiography concepts. Also included with the details of the discoveries of this research, shortcomings of the diagnostics and means of improving their fidelity are discussed.