Search NASA⌕ Search

SEARCH · Search NASA

Results for “analytical methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Establishing rapid analysis of Pu isotopes in seawater to study the impact of Fukushima nuclear accident in the Northwest Pacific

In order to evaluate the impact of the Fukushima derived Pu isotopes on seawater, a new analytical method to rapidly determine Pu isotopes in seawater by SF-ICP-MS including Fe(OH)2 primary co-precipitation, CaF 2 /LaF 3 secondary co-precipitation and TEVA+UTEVA+DGA extraction chromatographic separation was established. High concentration efficiency (~100%) and high U decontamination factor (~10 7 ) were achieved. The plutonium chemical recoveries were 74–88% with the mean of 83 ± 5%. The precisions for both 240 Pu/ 239 Pu atom ratios and 239+240 Pu activity concentrations were less than 5% when 15 L of seawater samples with the typical 239+240 Pu activity of the Northwest Pacific were measured. It just needs 12 hours to determine plutonium using this new method. The limit of detection (LOD) for 239 Pu and 240 Pu were both 0.08 fg/mL, corresponding to 0.01 mBq/m 3 for 239 Pu and 0.05 mBq/m 3 for 240 Pu when a 15 L volume of seawater was measured. This method was applied to determine the seawater samples collected 446–1316 km off the FDNPP accident site in the Northwest Pacific in July of 2013. The obtained 239+240 Pu activity concentrations of 1.21–2.19 mBq/m 3 and the 240 Pu/ 239 Pu atom ratios of 0.198–0.322 implied that there was no significant Pu contamination from the accident to the Northwest Pacific.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A new mathematical approach to finding global solutions of the magnetic structure determination problem

Abstract Determination of magnetic structure is an important analytical procedure utilized in various fields ranging from fundamental condensed-matter physics and chemistry to advanced manufacturing. It is typically performed using a neutron diffraction technique; however, finding global solutions of the magnetic structure optimization problem represents a significant challenge. Generally, it is not possible to mathematically prove that the obtained magnetic structure is a truly global solution and that no solution exists when no acceptable structure is found. In this study, the global optimization technique called semidefinite relaxation of quadratic optimization, which has attracted much interest in the field of applied mathematics, is proposed to use as a new analytical method for the determination of magnetic structure, followed by the application of polarized neutron diffraction data. This mathematical approach allows avoiding spurious local solutions, decreasing the amount of time required to find a tentative solution and finding multiple solutions when they exist.

97 MATHEMATICS AND COMPUTING↗

A simple soil mass correction for a more accurate determination of soil carbon stock changes

Abstract Agricultural soils can act as a sink for large quantities of soil organic carbon (SOC) but can also be sources of carbon to the atmosphere. The international standard for assessing SOC stock and measuring stock change stipulates fixed depth sampling to at least 30 cm. The tendency of bulk density (BD) to decrease with decreasing disturbance and increasing SOC concentration and the assumption of constant SOC and BD within this depth profile promotes error in the estimates of SOC stock. A hypothetical but realistic change in BD from 1.5 to 1.1 g cm −3 from successive fixed depth sampling to 30 cm underestimates SOC stock change by 17%. Significant effort has been made to evaluate and reduce this fixed depth error by using the equivalent soil mass (ESM) approach, but with limited adoption. We evaluate the error in SOC stock assessment and change generated from fixed depth measurements over time relative to the ESM approach and propose a correction that can be readily adopted under current sampling and analytical methods. Our approach provides a more accurate estimate of SOC stock accumulation or loss that will help incentivize management practice changes that reduce the environmental impacts of agriculture and further legitimize the accounting practices used by the emerging carbon market and organizations that have pledged to reduce their supply chain greenhouse gas (GHG) footprints.

60 APPLIED LIFE SCIENCES↗

Esterification of 3-quinuclidinol, a marker for the incapacitant BZ, for analysis by EI-GC-MS in OPCW test matrices

The analysis by EI-GC-MS of 3-quinuclidinol (3Q), a marker for the riot control and incapacitating agent quinuclinidyl benzilate (BZ), using several, new acylation strategies is described. After evaluating and optimizing conditions for the acylations, these were tested on their ability to successfully derivatize 3Q in three different matrices featured in the 44th Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test (PT). As 3Q is a highly polar compound, the work here describes acylation strategies that generate 3Q analogs with superior gas chromatographic profiles relative to the underivatized material. The acyl groups studied in this work included acetyl, benzoyl, pentafluorobenzoyl and the bis(3,5-trifluoromethyl)benzoyl. The acylated 3Q products provide sharp, detectable peaks with significantly different retention times from that of the unmodified 3Q. Thus, the retention times for acetyl-, benzoyl-, pentafluorobenzoyl- and 3,5-bis(trifluoromethyl)benzoyl-3Q were determined to be 15.9, 24.9, 22.8 and 22.1 min respectively, in stark contrast to the unmodified 3Q which provides a sharp peak with a retention time centered at ~ 13.5 min only at high concentrations (> 10 µg/mL or µg/g) while a broad peak (RT ~ 15–15.5 min) at low concentrations (< 5 µg/mL or µg/g). The developed protocol was used to derivatize 3Q in three separate matrices. The first two matrices were liquid samples featured during the 44th OPCW PT at two separate concentrations in each (5 and 50 µg/mL). The last matrix was a soil sample featured in the same 44th OPCW PT wherein the 3Q had been spiked at a 12 µg/g concentration. The approach involves the extraction of 3Q from all matrices followed by its acylation resulting in a second reportable analytical method for an OPCW PT. The presented derivatization strategies should find wide applicability particularly in laboratories involved with the analysis of this chemical weapon agent degradation product and those participating in the yearly OPCW PTs.

3-quinuclidinol↗

Sulfur isotopes from the Paleoproterozoic Francevillian Basin record multigenerational pyrite formation, not depositional conditions

Bulk-rock sulfur isotope data from pyrite in the ~2.1 billion-year sedimentary rocks of the Francevillian Basin, Gabon, have underpinned ideas about initial oxygenation of Earth’s surface environments and eukaryote evolution. In this paper, we show, using micro-scale analytical methods, that the bulk sulfur isotope record represents progressive diagenetic modification. Our findings indicate no significant change in microbial sulfur cycling processes and seawater sulfate composition throughout that initial phase of atmosphere-ocean oxygenation of Paleoproterozoic time. This offers an alternative view of Earth system evolution during the transition from an anoxic to an oxic state and highlights the need for a judicious reappraisal of conceptual models using sulfur isotope data as primary depositional signals linked to global-scale biogeochemical processes.

58 GEOSCIENCES↗

Colloidal quantum dots for optoelectronics

Colloidal quantum dots (QDs) are semiconductor nanocrystals that have unique size-tunable optoelectronic properties and are suitable for wet processing. QD research aims to answer fundamental questions about the chemical and physical properties of nanoscale materials and use these tools for technological applications ranging from bio-imaging to quantum optics. At the core of this field is a set of synthetic, processing and analytical methods designed to produce QDs in uniform ensembles that meet the highest performance standards. Here, this Primer reviews QD fabrication methods with a focus on the applications of QDs in printed optoelectronics and quantum optics. After outlining the current state-of-the-art QD syntheses, the experimental and computational analysis of QDs is discussed. These topics are then connected to the methodologies, processes and concepts required for developing QD-based photodetectors, light-emitting devices and quantum optics applications. Special attention is paid to challenges in reproducibility and current limitations of the field, such as the need to balance non-restricted material composition with high performing technology while achieving long-term stability in QD devices under operating conditions. Finally, the ongoing advancement in QD synthesis, precise atomic-level analysis and computational methodologies are highlighted as key drivers towards rational QD design, particularly in understanding how structural changes under loading impact QD properties.

optical materials↗

An open science resource for establishing reliability and reproducibility in functional connectomics

Efforts to identify meaningful functional imaging-based biomarkers are limited by the ability to reliably characterize inter-individual differences in human brain function. Although a growing number of connectomics-based measures are reported to have moderate to high test-retest reliability, the variability in data acquisition, experimental designs, and analytic methods precludes the ability to generalize results. The Consortium for Reliability and Reproducibility (CoRR) is working to address this challenge and establish test-retest reliability as a minimum standard for methods development in functional connectomics. Specifically, CoRR has aggregated 1,629 typical individuals’ resting state fMRI (rfMRI) data (5,093 rfMRI scans) from 18 international sites, and is openly sharing them via the International Data-sharing Neuroimaging Initiative (INDI). To allow researchers to generate various estimates of reliability and reproducibility, a variety of data acquisition procedures and experimental designs are included. Similarly, to enable users to assess the impact of commonly encountered artifacts (for example, motion) on characterizations of inter-individual variation, datasets of varying quality are included.

60 APPLIED LIFE SCIENCES↗

Probing Liquid Surfaces under Vacuum Using SEM and TOF-SIMS

Applying vacuum-based molecular probes of liquid surfaces would aid many environmental, biological, and industrial studies. However the high vapor pressure of water and most organic solvents largely prohibit this use. We report a newly developed versatile and self-contained vacuum interface for high-vapor pressure liquid surfaces, and its application in a time of flight secondary ion mass spectrometer (TOFSIMS) and scanning electron microscope (SEM). The self-contained module requires no wires or tubing connections to the outside of the instrument. It uses a microfluidic channel with a 3 micrometer diameter window into the flowing fluid beneath it. This window supports the liquid against the vacuum by the liquid’s surface tension, while limiting the high-density vapor region traversed by the probe beams to only a few microns. This aperture size also limits temperature and concentration changes due to evaporation of the solvent. The beam damage caused by the probe beams is largely negligible, as the flowing liquid surface self-renews. We demonstrate the performance of this microfluidic interface for in situ liquid surface TOFSIMS (ISLS-TOFSIMS) and SEM (ISLS-SEM) for chemical analysis of liquid surfaces. This device enables in situ liquid (ISL) studies in a wide range of vacuum analytical methods beyond SEM and TOFSIMS.

99 GENERAL AND MISCELLANEOUS↗

Probing Battery Chemistry with Liquid Cell Electron Energy Loss Spectroscopy

We demonstrate the ability to apply electron energy loss spectroscopy (EELS) to follow the chemistry and oxidation states of LiMn 2 O 4 and Li 4 Ti 5 O1 2 battery electrodes within a battery solvent. The use and importance of in situ electrochemical cells coupled with a scanning/transmission electron microscope (S/TEM) has expanded and been applied to follow changes in battery chemistry during electrochemical cycling. Furthermore, we discuss experimental parameters that influence measurement sensitivity and provide a framework to apply this important analytical method to future in situ electrochemical studies.

25 ENERGY STORAGE↗

The influence of ns- and fs-LA plume local conditions on the performance of a combined LIBS/LA-ICP-MS sensor

Both laser-induced breakdown spectroscopy (LIBS) and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) are well-established analytical techniques with their own unique advantages and disadvantages. The combination of the two analytical methods is a very promising way to overcome the challenges faced by each method individually. We made a comprehensive comparison of local plasma conditions between nanosecond (ns) and femtosecond (fs) laser ablation (LA) sources in a combined LIBS and LA-ICP-MS system. The optical emission spectra and ICP-MS signal were recorded simultaneously for both ns- and fs-LA and figures of merit of the system were analyzed. Characterization of the plasma was conducted by evaluating temperature and density of the plume under various irradiation conditions using optical emission spectroscopy, and correlations to ns- and fs-LIBS and LA-ICP-MS signal were made. The present study is very useful for providing conditions for a multimodal system as well as giving insight into how laser ablation plume parameters are related to LA-ICP-MS and LIBS results for both ns- and fs-LA.

LaHaye, Nicole L.↗

Gold silver alloy nanoparticles (GSAN): an imaging probe for breast cancer screening with dual-energy mammography or computed tomography

Earlier detection of breast cancer reduces mortality from this disease. Thus, the development of better screening techniques is a topic of intense interest. Contrast-enhanced dual-energy mammography (DEM) is a novel technique that has improved sensitivity for cancer detection. However, the development of contrast agents for this technique is in its infancy. We herein report gold-silver alloy nanoparticles (GSAN) that have potent DEM contrast properties and improved biocompatibility. GSAN formulations containing a range of gold:silver ratios and capped with m-PEG were synthesized and characterized using various analytical methods. DEM and computed tomography (CT) phantom imaging showed that GSAN produced robust contrast that was comparable to silver alone. Cell viability, reactive oxygen species generation and DNA damage results revealed that the formulations with 30% or higher gold content are cytocompatible to Hep G2 and J774A.1 cells. In vivo imaging was performed in mice with and without breast tumors. The results showed that GSAN produce strong DEM and CT contrast and accumulated in tumors. Furthermore, both in vivo imaging and ex vivo analysis indicated the excretion of GSAN via both urine and feces. In summary, GSAN produce strong DEM and CT contrast, and has potential for both blood pool imaging and for breast cancer screening.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single atoms and small clusters of atoms may accompany Au and Pd dendrimer-encapsulated nanoparticles

Here we report the presence of small clusters of atoms (<1 nm) (SCs) and single atoms (SAs) in solutions containing 1–2 nm dendrimer-encapsulated nanoparticles (DENs). Au and Pd DENs were imaged using aberration-corrected scanning transmission electron microscopy (ac-STEM), and energy dispersive spectroscopy (EDS) was used to identify and quantify the SAs/SCs. Two main findings have emerged from this work. First, the presence or absence of SAs/SCs depends on both the terminal functional group of the dendrimer (–NH 2 or –OH) and the elemental composition of the DENs (Au or Pd). Second, dialysis can be used to remove the majority of SAs/SCs in cases where a high density of SAs/SCs are present. The foregoing conclusions provide insights into the mechanisms for Au and Pd DEN synthesis and stability. Ultimately, these results demonstrate the need for careful characterization of systems containing nanoparticles to ensure that SAs/SCs, which may be below the detection limit of most analytical methods, are taken into consideration (especially for catalysis experiments).

74 ATOMIC AND MOLECULAR PHYSICS↗

Enhancing Drinking Water Quality Modeling: Leveraging Physics Informed Neural Networks for Learning with Imperfect Reaction Models and Partial Data

Chemical kinetics models, typically formulated as systems of ordinary or partial differential equations, are valuable tools for simulating drinking water quality. However, these models often face inaccuracies due to discrepancies between the laboratory and the real-world conditions, as well as limitations in experimental analytical methods, hindering the accurate representation of the true underlying chemical mechanisms. In this study, we propose a Physics Informed Neural Network (PINN), using the eXtreme Theory of Functional Connections, to improve the prediction of chemical concentrations over time. The PINN method accounts for imperfect chemical models and incorporates partial data to improve predictions. Focusing on reactions describing water disinfection residual and disinfectant byproduct formation, which are crucial for public health and regulatory compliance, we demonstrate that the PINN model is able to accurately predict the concentrations of chemical species across various pH values. Notably, the model extends its accuracy to predict concentrations of chemical species not originally included in its training data. The developed method can be extended to a variety of chemical systems, offering a wide array of potential applications.

13 HYDRO ENERGY↗

A graph embedding‐based approach for automatic cyber‐physical power system risk assessment to prevent and mitigate threats at scale

Abstract Power systems are facing an increasing number of cyber incidents, potentially leading to damaging consequences to both physical and cyber aspects. However, the development of analytical methods for the study of large‐scale power infrastructures as cyber‐physical systems is still in its early stages. Drawing inspiration from machine‐learning techniques, the authors introduce a method inspired by the principles of graph embedding that is tailored for quantitative risk assessment and the exploration of possible mitigation strategies of large‐scale cyber‐physical power systems. The primary advantage of the graph embedding approach lies in its ability to generate numerous random walks on a graph, simulating potential access paths. Meanwhile, it enables capturing high‐dimensional structures in low‐dimensional spaces, facilitating advanced machine‐learning applications, and ensuring scalability and adaptability for comprehensive network analysis. By employing this graph embedding‐based approach, the authors present a structured and methodical framework for risk assessment in cyber‐physical systems. The proposed graph embedding‐based risk analysis framework aims to provide a more insightful perspective on cyber‐physical risk assessment and situation awareness for power systems. To validate and demonstrate its applicability, the method has been tested on two cyber‐physical power system models: the Western System Coordinating Council (WSCC) 9‐Bus System and the Illinois 200‐Bus System , thereby showing its advantages in enhancing the accuracy of risk analysis and comprehensiveness of situational awareness.

Sun, Shining↗

Hot-electron recirculation in ultraintense laser pulse interactions with thin foils

A model, called the Step Model, is proposed to describe hot-electron recirculation. A formula to estimate electron density at the rear side sheath is described. With a fixed initial hot-electron density for some target thicknesses, the results from the Step Model are compared with several experiments. The influences of laser pulse absorption efficiency, laser pulse duration, the opening angle of hot-electrons, hot-electron recirculation, and target thickness on the ion acceleration are discussed. When the target thickness is far less than the laser focus radius, the initial electron density will be proportional to the laser pulse absorption efficiency, and the angular effect and the thickness effect can both be ignored. For any target thickness, the maximum ion velocity accelerated by the rear side sheath can be calculated using the Step Model. As an application to some experiments, the Step Model provides a half-analytic method to achieve the dependence of the laser pulse absorption efficiency on target thickness and the influence of amplified spontaneous emission (ASE) duration on the laser absorption efficiency.

36 MATERIALS SCIENCE↗

Hard x-rays nanoscale fluorescence imaging of Earth and Planetary science samples

A hard x-ray nanoprobe has been implemented at the synchrotron in Grenoble, France, allowing nondestructive trace element imaging of thick samples. Its advantages are nanometer spatial resolution on samples of several tens of micrometer, very high flux, and achromaticity. Nanometer imaging of a cometary grain from the NASA Stardust mission shows the sensitivity and resolution gains obtained while radically changing our understanding of the composition of heterogeneous samples. The probe opens unique possibilities in the study of minute, fragile samples fundamental to the earth and planetary sciences, which until now were out of the reach of direct analytical methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shielding Calculation for High Energy Radiation X-Ray by Software program

There are analytic methods for designing protective barriers however, they lack sufficient efficiency and considering the NCRP147(reports2007), designing mechanical protective barrier in order to protect the initial x-ray radiation and absorption of the ray quality of such radiation is different. In this study, computer software was designed to calculate the needed barrier with high accuracy. For proper determination of thickness of the protective barrier, relevant information about curves of radiation weakness, dose limit etc should be entered. The difference between the theoretical and calculated rates of this method is X{sup 2} = 10{sup -5} which indicates accuracy and high efficiency of this software.

61 RADIATION PROTECTION AND DOSIMETRY↗