Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Integrated modeling of alpha particle losses in JET DT plasmas

Alpha particle confinement is crucial for sustaining burning plasmas and designing future reactor concepts. Along with classical/prompt losses, various magnetohydrodynamic instabilities can lead to wave-particle interactions which can transport alpha particles outward from the plasma. This can result in a reduction in plasma heating/performance, and, at worst, damage in-vessel components. Joint European Torus’s recent deuterium–tritium campaigns in 2021–2023 have produced numerous alpha particle loss measurements with its scintillator probe and Faraday cup array fast ion loss detectors as discussed in Bonofiglo et al (2024 Nucl. Fusion 64 096038). This paper will report on integrated energetic particle transport modeling in support of those measurements. The modeling is accomplished with the TRANSP and ORBIT-kick codes with the use of recently developed reduced models which calculate mode structure, amplitude, and the evolving dynamics. When possible, constraints and comparisons to experiment are conducted. Case studies are performed on a variety of magnetohydrodynamic activity, including: fishbones, tearing modes (TMs), and sawtooth crashes. Additionally, a special case of an alpha-driven toroidal Alfvén eigenmode is briefly discussed, where modeling showed marginally weak alpha losses and was unable to support experimental observations. Coupled effects between a TM and toroidal field ripple are presented and were unable to replicate the observations in lost particle pitch but did duplicate the localized flattening of the measured neutron profile. Additional modeling results compare the magnitude of losses and energy/velocity-space sensitivities against experimental observations/measurements for each scenario. This work corroborates numeric alpha transport modeling while also identifying model deficiencies. While this report details alpha transport, it also presents open issues for discussion in assessing the validity of our numerical models towards burning plasmas.

Bonofiglo, Phillip J. [Princeton Plasma Physics La↗

The CUORE and CUORE-0 experiments at LNGS

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. The construction of the experiment and, in particular, the installation of all towers in the cryostat was completed in August 2016 and commissioning started in fall 2016. The experiment has completed the pre-operation phase and is currently in data taking. We present here the achievements of CUORE during the commissioning phase and the limit on the 130Te half-life for the neutrinoless double beta decay that has been released after the first 3 weeks of collected data. Physics results from CUORE-0 will also be updated.

Alduino, C↗

Results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta (0νββ) decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. The construction of the experiment and, in particular, the installation of all towers in the cryostat was completed in 2016 and data taking started in 2017. In this conference we present the 0νββ decay results of CUORE from examining a total TeO2 exposure of 86.3 kg yr, characterized by an effective energy resolution of 7.7 keV FWHM and a background in the region of interest of 0.014 counts/(keV kg yr). Based on these data, CUORE places a lower limit on the 0νββ decay half-life of (90% C.L.). We then discuss the latest updates in the analysis of background and in the evaluation of the half-life of 2νββ decay of 130Te.

Chiesa, D↗

Investigation of secondary γ -ray angular distributions using the N 15 ( p , α 1 γ ) C * 12 reaction

The observation of secondary γ-rays provides an alternative method of measuring cross sections that populate excited final states in nuclear reactions. The angular distributions of these γ-rays also provide information on the underlying reaction mechanism. Despite a large amount of data of this type in the literature, publicly available R-matrix codes do not have the ability to calculate these types of angular distributions. In this report, the mathematical formalism derived in Brune and deBoer is implemented in the R-matrix code AZURE2 and calculations are compared with previous data from the literature for the 15 N( p, α1γ ) 12 C* reaction. In addition, new measurements, made at the University of Notre Dame Nuclear Science Laboratory using the Hybrid Array of Gamma Ray Detectors (HAGRiD), are reported that span an energy range from E p = 0.88 to 4.0 MeV. Excellent agreement between data and the phenomenological fit is obtained up to the limit of the previous fit at E p = 2.0 MeV and the R-matrix fit is extended from E x ≈ 13.5 up to E x ≈ 15.3 MeV, where 15 N+p and 12 C+α reactions are fit simultaneously for the first time. An excellent reproduction of the 15 N( p, α1γ ) 12 C* and 12 C(α, α) 12 C data is achieved, but inconsistencies and difficulty in fitting other data is encountered and discussed.

6 ≤ A ≤ 19↗

Levels in 125 Cd populated by the β decay of 125 m Ag and 125 Ag

Here, the β decay of 125 m, 125 Ag into levels in 125 Cd was investigated at the Holifield Radioactive Ion Beam Facility (HRIBF). Uranium-238 targets were bombarded with 50-MeV protons with an intensity of 15 μ A, and the induced fission products were mass separated and deposited on a moving tape in the center of the VANDLE array consisting of γ detectors and plastic scintillators. A partial decay scheme has been assigned for both β decay of the (9/2 + ) ground state of 125 Ag and its low-lying (1/2 - ) isomer, with the energy of the low-lying (11/2 - ) isomeric state in 125 Cd assigned as 188.5 keV. In addition, β -delayed neutron emission probabilities were also determined to be 1.2(2)% for the (9/2 + ) 125 Ag ground state and 4.6(10)% for the (1/2 - ) isomer, which are substantially lower than the previously reported value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low spin spectroscopy of neutron-rich Cl 43 , 44 , 45 via β - and β n decay

In this article, β - decay studies of neutron-rich isotopes 43,45 S performed at the National Superconducting Cyclotron Laboratory are reported. β -delayed $\gamma$ transitions were detected by an array of 16 clover detectors surrounding the Beta Counting Station, which consists of a 40×40 double-sided silicon strip detector followed by a single-sided silicon strip detector. β -decay half-lives were extracted for 43,45 S by correlating implants and decays in the pixelated implant detector and by considering further coincidences with $\gamma$ transitions in the daughter nuclei. Further, the level structures of 43,45 Cl are expanded by the addition of 20 and 8 new $\gamma$ transitions in 43 Cl and 45 Cl respectively, and core-excited negative-parity states were observed in both nuclei for the first time. For 45 S, a large fraction of the β -decay strength was observed feeding neutron-unbound states in 45 Cl, which, decaying by delayed neutrons, populated excited states in the β ⁢1⁢ n daughter, 44 Cl. Experimental observations were compared to detailed shell-model calculations using the SDPFSDG-MU interaction to highlight the role of the diminished N = 28 neutron shell gap and the near degeneracy of the proton s 1/2 and d 3/2 orbitals in the structure of the neutron-rich Cl isotopes. The current work also provides further support to a ground-state spin-parity assignment of 3/2 + in 45 Cl.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New levels and a lifetime measurement in {sup 204}Tl

The {sup 205}Tl(n,2n{gamma}) reaction was used to populate excited states in {sup 204}Tl. The {gamma}-ray detection was accomplished with the GEANIE spectrometer, a Compton suppressed array of 26 Ge detectors. An energetic beam of neutrons was provided by the pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility. The time-of-flight technique was used to determine the incident neutron energies. {gamma}-ray excitation functions were determined from incident neutron energy of 1 MeV up to E{sub n}=25 MeV. The level scheme of {sup 204}Tl was enriched and the partial level scheme and nuclear structure above the previously known 7{sup +} isomer at 1104-keV excitation energy were established for the first time up to E{sub x}{approx}2.3 MeV. The high-spin part of the level scheme exhibits striking similarities to that of the neighboring {sup 202}Tl isotope, suggesting similarities in the underlying nuclear structure. The half-life of the 7{sup +} isomer was measured with a more precise result (T{sub 1/2}=60.7{+-}1.2 {mu}s), in agreement with literature values. A lower limit for the excitation energy of the {pi}h{sub 11/2}{nu}i{sub 13/2} structure with J{sup {pi}}=12{sup -} is proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy distribution of ternary {alpha} particles in spontaneous fission of {sup 252}Cf

The energy distribution of the ternary {alpha} particles in spontaneous fission of {sup 252}Cf was measured. For the first time an energy threshold as low as 1 MeV was reached. The experiment used an array of unshielded silicon detectors measuring energy and time-of-flight (TOF) of ternary particles in coincidence with fission fragments. The TOF resolution of the system was sufficient for clear separation of {sup 6}He and tritons from {sup 4}He. The statistics were adequate to extract the {sup 6}He/{sup 4}He yield ratio. For both {sup 4}He and {sup 6}He, an excess in the yield (as compared to a Gaussian shape) was observed at energies below 9 MeV. The measured ternary {alpha} spectrum was corrected for the distortion induced by the detection geometry covering equatorial particle emission only. The emission angle was found to affect mainly the width of the energy distribution by up to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of elastic {sup 12}C+{alpha} scattering: Details of the experiment, analysis, and discussion of phase shifts

Recent global analyses of {sup 12}C({alpha},{gamma}){sup 16}O have incorporated both elastic-scattering and {beta}-decay data in addition to direct measurements. In that context, it has been shown that an improvement in the available elastic-scattering data could help determine the contribution of the two subthreshold states, 6.92(2{sup +}) and 7.12(1{sup -}) MeV, and with excellent statistics could restrict resonance parameters above the threshold. To this end angular distributions of {sup 12}C({alpha},{alpha}){sup 12}C in the {alpha}-energy range of 2.6-8.2 MeV, at angles from 24 deg. to 166 deg. have been measured at the University of Notre Dame using an array of 32 silicon detectors. Details of the experiment are reported. In the present analysis, the phase shifts have been determined from our previously reported R-matrix fit to these data. The uncertainties in the R-matrix phase shifts (l=0...6) are derived by a new Monte Carlo analysis technique as described in the article. We provide these phase shifts here for general use, in particular for the improved analysis and extrapolation of the {alpha} radiative capture to low energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First 3{sup -} excited state of {sup 56}Fe

There is no reliable evidence for the existence of the 3.076 MeV (3{sup -}) level adopted in the ENSDF evaluation for {sup 56}Fe although it has been reported in a few experiments. Previous reports of the observation of this level appear to be based on an incorrect assignment in early (e,e{sup '}) work. Recent neutron inelastic scattering measurements by Demidov et al. [Phys. At. Nucl. 67, 1884, (2004)] show that the assigned {gamma}-ray decay of this state does not occur at a level consistent with known properties of inelastic scattering. In the present work the {sup 56}Fe(n,n{sup '}{gamma}) reaction was used to populate excited states in {sup 56}Fe. Neutrons in the energy range from 1 to 250 MeV were provided by the pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility. Deexciting {gamma} rays were detected with the GEANIE spectrometer, a Compton suppressed array of 26 Ge detectors. The {gamma}-{gamma} data obtained with GEANIE were used to establish coincidence relations between transitions. All previously reported levels up to E{sub x}=3.6 MeV excitation energy were observed except for the 3.076 MeV (3{sup -}) level. The 991- and 2229-keV transitions, previously reported to deexcite this level, were not observed in the {gamma}-{gamma} coincidence data obtained in the present experiment. The present work supports the assignment of the 4509.6 keV level as the first 3{sup -} excited state in {sup 56}Fe by observation of two previously known transitions deexciting this state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of two-proton emission from excited states of the odd-Z nucleus {sup 28}P by complete-kinematics measurements

An experiment to study exotic two-proton emission from excited levels of the odd-Z nucleus {sup 28}P was performed at the National Laboratory of Heavy Ion Research-Radioactive Ion Beam Line (HIRFL-RIBLL) facility. The projectile {sup 28}P at the energy of 46.5 MeV/u was bombarding a {sup 197}Au target to populate the excited states via Coulomb excitation. Complete-kinematics measurements were realized by the array of silicon strip detectors and the CsI+PIN telescope. Two-proton events were selected and the relativistic-kinematics reconstruction was carried out. The spectrum of relative momentum and opening angle between two protons was deduced from Monte Carlo simulations. Experimental results show that two-proton emission from {sup 28}P excited states less than 17.0 MeV is mainly two-body sequential emission or three-body simultaneous decay in phase space. The present simulations cannot distinguish these two decay modes. No obvious diproton emission was found.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of two-{alpha} emission from high-lying excited states of {sup 18}Ne by complete-kinematics measurements

Two-{alpha} emission from high-lying excited states of {sup 18}Ne was studied by complete-kinematics measurements. The {sup 18}Ne beam at the energy of 51.8 MeV/u was bombarding a {sup 197}Au target to populate the excited states via Coulomb excitation. Products of two-{alpha} emission, {sup 10}C-{alpha}-{alpha}, were measured by an array of silicon strip detectors and a CsI + PIN telescope. With the help of Monte Carlo simulations, the experimental results show the characteristics of sequential two-{alpha} emission via {sup 14}O excited states. Sequential two-{alpha} and two-proton emissions from {sup 18}Ne via one-particle daughter states are compared and the distinction of the opening angles of these two modes originates from the difference of the mass ratio of emitted particles to daughter nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiment to demonstrate separation of Cherenkov and scintillation signals

The ability to separately identify the Cherenkov and scintillation light components produced in scintillating mediums holds the potential for a major breakthrough in neutrino detection technology, allowing development of a large, low-threshold, directional detector with a broad physics program. Furthermore, the CHESS (CHErenkov/Scintillation Separation) experiment employs an innovative detector design with an array of small, fast photomultiplier tubes and state-of-the-art electronics to demonstrate the reconstruction of a Cherenkov ring in a scintillating medium based on photon hit time and detected photoelectron density. Our paper describes the physical properties and calibration of CHESS along with first results. The ability to reconstruct Cherenkov rings are demonstrated in a water target, and a time precision of 338 ± 12 ps FWHM is achieved. Finally, Monte Carlo–based predictions for the ring imaging sensitivity with a liquid scintillator target predict an efficiency for identifying Cherenkov hits of 94 ± 1 % and 81 ± 1 % in pure linear alkyl benzene (LAB) and LAB loaded with 2 g/L of a fluor, PPO, respectively, with a scintillation contamination of 12 ± 1 % and 26 ± 1 % .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraining the Neutron Star Compactness: Extraction of the Al 23 ( p , γ ) Reaction Rate for the r p Process

The 23 Al(p,γ) 24 Si reaction is among the most important reactions driving the energy generation in type-I x-ray bursts. However, the present reaction-rate uncertainty limits constraints on neutron star properties that can be achieved with burst model-observation comparisons. In this work, we present a novel technique for constraining this important reaction by combining the GRETINA array with the neutron detector LENDA coupled to the S800 spectrograph at the National Superconducting Cyclotron Laboratory. The 23 Al(d,n) reaction was used to populate the astrophysically important states in 24 Si. This enables a measurement in complete kinematics for extracting all relevant inputs necessary to calculate the reaction rate. For the first time, a predicted close-lying doublet of a $2^{+}_{2}$ and ($4^{+}_{1}, 0^{+}_{2}$) state in 24 Si was disentangled, finally resolving conflicting results from two previous measurements. Furthermore, it was possible to extract spectroscopic factors using GRETINA and LENDA simultaneously. This new technique may be used to constrain other important reaction rates for various astrophysical scenarios.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing Floating Guard Ring Designs for FASPAX N-in-P Silicon Sensors

FASPAX (Fermi-Argonne Semiconducting Pixel Array X-ray detector) is being developed as a fast integrating area detector with wide dynamic range for time resolved applications at the upgraded Advanced Photon Source (APS.) A burst mode detector with intended $\mbox{13 $MHz$}$ image rate, FASPAX will also incorporate a novel integration circuit to achieve wide dynamic range, from single photon sensitivity to $10^{\text{5}}$ x-rays/pixel/pulse. To achieve these ambitious goals, a novel silicon sensor design is required. This paper will detail early design of the FASPAX sensor. Results from TCAD optimization studies, and characterization of prototype sensors will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations

Purpose: To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. Methods: A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was used to simultaneously detect radiation levels across a scan field-of-view. The sampling time was as short as 0.24 ms. To measure the body bow-tie attenuation on a GE Lightspeed Pro 16 CT scanner, the x-ray tube was parked at the 12 o’clock position, and the detector was centered in the scan field at the isocenter height. Two radiation exposures were made with and without the bow-tie in the beam path. Each readout signal was corrected for the detector background offset and signal-level related nonlinear gain, and the ratio of the two exposures gave the bow-tie attenuation. The results were used in the GEANT4 based simulations of the point doses measured using six thimble chambers placed in a human cadaver with abdomen/pelvis CT scans at 100 or 120 kV, helical pitch at 1.375, constant or variable tube current, and distinct x-ray tube starting angles. Results: Absolute attenuation was measured with the body bow-tie scanned at 80–140 kV. For 24 doses measured in six organs of the cadaver, the median or maximum difference between the simulation results and the measurements on the CT scanner was 8.9% or 25.9%, respectively. Conclusions: The described method allows fast and accurate bow-tie filter characterization.

60 APPLIED LIFE SCIENCES↗