Summary Report of Working Group 4: Plasma Wakefield Acceleration

This report gives a guide to the discussions of Working Group 4 of the 2010 Advanced Accelerator Concepts Workshop, which was devoted to theory, simulation and experimental issues associated with plasma wakefield acceleration (PWFA). Sessions were organized thematically in this group, concentrating on broad issues of: exploitation of future facilities such as FACET; pushing the accelerating gradient beyond the current frontier, to over a TeV/m; use of positively charged beams to drive plasma wakes; resonant excitation of the PWFA with pulse trains; beam-plasma instabilities; and injection and capture of electron beams into PWFA systems.

43 PARTICLE ACCELERATORS↗

High gradient tests of metallic mm-wave accelerating structures

This study explores the physics of vacuum rf breakdowns in high gradient mm-wave accelerating structures. We performed a series of experiments with 100 GHz and 200 GHz metallic accelerating structures, at the Facility for Advanced Accelerator Experimental Tests (FACET) at the SLAC National Accelerator Laboratory. This paper presents the experimental results of rf tests of 100 GHz travelling-wave accelerating structures, made of hard copper-silver alloy. The results are compared with pure hard copper structures. The rf fields were excited by the FACET ultra-relativistic electron beam. The accelerating structures have open geometries, 10 cm long, composed of two halves separated by a variable gap. The rf frequency of the fundamental accelerating mode depends on the gap size and can be changed from 90 GHz to 140 GHz. The measured frequency and pulse length are consistent with our simulations. When the beam travels off-axis, a deflecting field is induced in addition to the decelerating longitudinal field. We measured the deflecting forces by observing the displacement of the electron bunch and used this measurement to verify the expected accelerating gradient. We present the first quantitative measurement of rf breakdown rates in 100 GHz copper-silver accelerating structure, which was 10 –3 per pulse, with peak electric field of 0.42 GV/m, an accelerating gradient of 127 MV/m, at a pulse length of 2.3 ns. The goal of our studies is to understand the physics of gradient limitations in order to increase the energy reach of future accelerators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and testing of coarse-grained models for ultrasonic simulations of cast austenitic stainless steel

Ultrasonic inspection of cast austenitic stainless steel (CASS) in the nuclear industry is particularly challenging because of sound field scatter and attenuation caused by the coarse-grained microstructure. Modeling and simulation are important tools in ultrasonic testing, as they can be used to help address key aspects of inspections, such as developing new probe designs, predicting inspection reliability, and testing phased-array focal laws. However, developing a useful and reliable CASS model is challenging due to the many grain interfaces and crystalline orientations that must be captured. We demonstrate a method of creating a realistic CASS model that is usable in CIVA, a commercially available modeling and simulation software platform. Using polished and chemically etched sections, we generate models of a coarse-grained equiaxed specimen and a columnar specimen. We also test an alternative method of generating a coarse-grained model using Voronoi regions. We qualitatively compare sound field scatter and quantitatively compare sound field attenuation and beam partitioning in simulated sound fields to those of laboratory-measured sound fields. Results show that the Voronoi models perform as well as or better than the models based on actual grain morphology. Here we also show that model-to-model randomness in Voronoi grain structure can impact the magnitude of a simulated echo response by a factor of two or more. Although CASS models are potentially a good depiction of reality for a given scenario, they should not be considered representative since CASS morphology can change significantly from specimen to specimen or within the same specimen.

36 MATERIALS SCIENCE↗

Strong-field QED experiments using the BELLA PW laser dual beamlines

The petawatt (PW) laser facility of the Berkeley Lab Laser Accelerator (BELLA) Center has recently commissioned its second laser pulse transport line. This new beamline can be operated in parallel with the first beamline and enables strong-field quantum electrodynamics (SF-QED) experiments at BELLA. In this paper, we present an overview of the upgraded BELLA PW facility with a SF-QED experimental layout in which intense laser pulses collide with GeV-class laser-wakefield-accelerated electron beams. We present simulation results showing that experiments will allow the study of laser-particle interactions from the classical to the SF-QED regime with a nonlinear quantum parameter of up to χ ~2. Additionally, we show that experiments will enable the study and production of GeV-class, mrad-divergence positron beams via the Breit–Wheeler process. Graphical abstract: [Figure not available: see fulltext.].

43 PARTICLE ACCELERATORS↗

Convergence study of wakefield simulations with GdfidL and ECHO3D

The interaction of charged particle beams with vacuum chamber components gives rise to electromagnetic wakefields, whose frequency-domain representation is known as beam coupling impedance. Geometric impedance arising from discontinuities and transitions in the vacuum chamber is the focus of this study. Minimizing this impedance is essential to mitigate adverse collective effects in modern storage rings operating with high-intensity particle beams. Accurate and reliable impedance simulations is a key factor of the vacuum chamber design. This paper presents the results of a convergence study of two widely used electromagnetic solvers, GdfidL and ECHO3D, applied to key vacuum-chamber components of the National Synchrotron Light Source II (NSLS-II) storage ring. Detailed comparisons are performed for several geometries, including flange absorbers, RF bellows, button-type beam position monitors, and an in-vacuum undulator (IVU). The results show notable differences in convergence and computational efficiency between the two codes. While GdfidL provides highly resolved results and serves as a common benchmark tool, ECHO3D yields consistent results with coarser meshes, significantly reducing simulation time and memory demands. Simulations with a full-geometry IVU model demonstrate that simplified taper-transition models can miss important impedance contributions. In conclusion, these findings provide practical guidelines for efficient and accurate impedance modeling to optimize design of vacuum chamber components for accelerators.

36 MATERIALS SCIENCE↗

On the possibility of generating low-energy positrons on accelerators of electrons with a beam energy of a few MeV and on terawatt lasers

Based on the numerical simulations, we estimate the possibility of generating positrons by low-energy electrons (below 10 MeV) produced by electron accelerators and femtosecond lasers. A review of experimental work reported in the literature is presented. The simulation is carried out using the GEANT-4 software package for the particular conditions of a possible experiment at the terawatt femtosecond laser facility of the International Laser Centre at the Moscow State University and the LUE-8 MeV linear electron accelerator at the Institute for Nuclear Research, Russian Academy of Sciences. (paper)

43 PARTICLE ACCELERATORS↗

The simulation of lunar micrometeorite impacts by laser pulses

Laser pulses of a finely focused beam were used to simulate micrometeorite impacts on lunar rocks and in lunar soil. The electron microscope pictures show the detailed effects so caused; it is possible to derive an estimate of the comparative amounts of erosion a given micrometeorite flux would cause in lunar rocks and lunar soil.

Bilson, E.↗

Magnetic shielding of walls from the unmagnetized ion beam in a Hall thruster

We demonstrate by numerical simulations and experiments that the unmagnetized ion beam formed in a Hall thruster can be controlled by an applied magnetic field in a manner that reduces by 2-3 orders of magnitude deleterious ion bombardment of the containing walls. The suppression of wall erosion in Hall thrusters to such low levels has remained elusive for decades.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling of the charge-state separation at ITEP experimental facility for material science based on a Bernas ion source

The experiment automation system is supposed to be developed for experimental facility for material science at ITEP, based on a Bernas ion source. The program CAMFT is assumed to be involved into the program of the experiment automation. CAMFT is developed to simulate the intense charged particle bunch motion in the external magnetic fields with arbitrary geometry by means of the accurate solution of the particle motion equation. Program allows the consideration of the bunch intensity up to 10{sup 10} ppb. Preliminary calculations are performed at ITEP supercomputer. The results of the simulation of the beam pre-acceleration and following turn in magnetic field are presented for different initial conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear dynamics of diocotron instability

The nonlinear dynamics of the diocotron instability of an electron beam in a waveguide is investigated by numerical simulations. A study is made of how the structures arising in the beam depend on the geometric parameters of the problem. It is shown that the energy source for such azimuthal structures is the initial (stored in the formation of the beam) electrostatic energy of the unneutralized beam charge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining mode excitations of vacuum electronics devices via three-dimensional simulations using the SOS code

The SOS code is used to compute the resonance modes (frequency-domain information) of sample devices and separately to compute the transient behavior of the same devices. A code, DOT, is created to compute appropriate dot products of the time-domain and frequency-domain results. The transient behavior of individual modes in the device is then plotted. Modes in a coupled-cavity traveling-wave tube (CCTWT) section excited beam in separate simulations are analyzed. Mode energy vs. time and mode phase vs. time are computed and it is determined whether the transient waves are forward or backward waves for each case. Finally, the hot-test mode frequencies of the CCTWT section are computed.

Warren, Gary↗

SU-E-T-132: Assess the Shielding of Secondary Neutrons From Patient Collimator in Proton Therapy Considering Secondary Photons Generated in the Shielding Process with Monte Carlo Simulation

Purpose: In this study we present Monte Carlo based evaluation of the shielding effect for secondary neutrons from patient collimator, and secondary photons emitted in the process of neutron shielding by combination of moderator and boron-10 placed around patient collimator. Methods: The PHITS Monte Carlo Simulation radiation transport code was used to simulate the proton beam (Ep = 64 to 93 MeV) from a proton therapy facility. In this study, moderators (water, polyethylene and paraffin) and boron (pure {sup 10}B) were placed around patient collimator in this order. The rate of moderator and boron thicknesses was changed fixing the total thickness at 3cm. The secondary neutron and photons doses were evaluated as the ambient dose equivalent per absorbed dose [H*(10)/D]. Results: The secondary neutrons are shielded more effectively by combination moderators and boron. The most effective combination of shielding neutrons is the polyethylene of 2.4 cm thick and the boron of 0.6 cm thick and the maximum reduction rate is 47.3 %. The H*(10)/D of secondary photons in the control case is less than that of neutrons by two orders of magnitude and the maximum increase of secondary photons is 1.0 µSv/Gy with the polyethylene of 2.8 cm thick and the boron of 0.2 cm thick. Conclusion: The combination of moderators and boron is beneficial for shielding secondary neutrons. Both the secondary photons of control and those emitted in the shielding neutrons are very lower than the secondary neutrons and photon has low RBE in comparison with neutron. Therefore the secondary photons can be ignored in the shielding neutrons.This work was supported by JSPS Core-to-Core Program (No.23003). This work was supported by JSPS Core-to-Core Program (No.23003)

60 APPLIED LIFE SCIENCES↗

Startup of the Kling Center for Proton Therapy

In November of 2011 Mevion Medical Systems (formerly Still River Systems) delivered the Mevion S250 proton therapy system accelerator to the Kling Center for Proton Therapy at the Siteman Cancer Center in Saint Louis. The Mevion system is unique, with an in-room gantry-mounted superconducting synchrocyclotron. This is the first true single-room proton therapy system and it has a greatly reduced size as well as cost. A month after its arrival, the installation was complete and the superconducting magnet was ramped up to full current ({approx}2000 amperes). In March of 2012, full energy beam (250 MeV) was extracted and radiation surveys were performed to verify the shielding. Once that was shown to be sufficient, Mevion began fine-tuning the system to provide a highly isocentric beam from the 50 ton system. In June of 2012 the field-shaping system (energy degraders, contoured scatterers and range modulators) were installed and measurements of the clinical beam properties commenced. Monte Carlo simulations (MCNPX) have been performed for the system and validated with beam measurements done at the factory. These simulations have been used for a preliminary commissioning of our treatment planning system. Additionally, predictions of the neutron background have been made and validated with factory measurements. Final commissioning of the treatment planning system and verification of the neutron background will be accomplished with measurements made later in 2012. Based on current progress, patient treatments are scheduled to begin in late 2012. Beam and radiation background data will be presented.

43 PARTICLE ACCELERATORS↗

Verification and benchmarking relativistic electron beam transport through a background gas

It is necessary to establish confidence in high-consequence codes containing an extensive suite of physics algorithms in the regimes of interest. Verification problems allow code developers to assess numerical accuracy and increase confidence that specific sets of model physics were implemented correctly in the code. The two main verification techniques are code verification and solution verification. In this work, we present verification problems that can be used in other codes to increase confidence in simulations of relativistic beam transport. Specifically, we use the general plasma code EMPIRE to model and compare with the analytical solution to the evolution of the outer radial envelope of a relativistic charged particle beam. Additionally, we also outline a benchmark test of a relativistic beam propagating through a vacuum and pressurized gas cell, and present the results between EMPIRE and the hybrid code GAZEL. Further, we discuss the subtle errors that were caught with these problems and detail lessons learned.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of ion-to-electron mass ratio on the evolution of ion beam driven instability in particle-in-cell simulations

In particle-in-cell (PIC) simulation studies of ion-ion two-stream instability, a reduced ion-to-electron mass ratio is often employed to save computation time. It is tacitly assumed that electrons do not play a significant role in the evolution of the instability as the ion-ion interactions are regarded to occur on time scales much slower than the response time of electrons. However, as the effect of such a reduced mass ratio has never been closely examined, we have studied the evolution of the ion beam driven instability using a one-dimensional electrostatic PIC code by rescaling the simulation parameters according to the ion-electron mass ratio. We made a reference simulation run with a mass ratio of 100 first and compared the results to the simulation results using the real mass ratio with parameters rescaled from those of the reduced mass ratio. External electric fields were applied in these simulations, which accelerated the electrons and excited an ion acoustic type instability, forming electron phase space holes. Merging of the electron holes affected the ion dynamics significantly when the reduced mass ratio was used, while the interplay between the electron and ion dynamics became different depending on the rescaling methods in the case of the real mass ratio. Another simulation test with much enhanced external electric field results in similar mass ratio dependence. The present simulation results clearly show that the reduced mass ratio should be used cautiously in PIC simulations as the electron dynamics can modify the ion instabilities significantly by affecting the ion motions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Antenna induced range smearing in MST radars

There is considerable interest in developing stratosphere troposphere (ST) and mesosphere stratosphere troposphere (MST) radars for higher resolution to study small-scale turbulent structures and waves. At present most ST and MST radars have resolutions of 150 meters or larger, and are not able to distinguish the thin (40 - 100 m) turbulent layers that are known to occur in the troposphere and stratosphere, and possibly in the mesosphere. However the antenna beam width and sidelobe level become important considerations for radars with superior height resolution. The objective of this paper is to point out that for radars with range resolutions of about 150 meters or less, there may be significant range smearing of the signals from mesospheric altitudes due to the finite beam width of the radar antenna. At both stratospheric and mesospheric heights the antenna sidelobe level for lear equally spaced phased arrays may also produce range aliased signals. To illustrate this effect the range smearing functions for two vertically directed antennas have been calculated, (1) an array of 32 coaxial-collinear strings each with 48 elements that simulates the vertical beam of the Poker Flat, Glaska, MST radar; and (2) a similar, but smaller, array of 16 coaxial-collinear strings each with 24 elements.

Watkins, B. J.↗

Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation

The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle3 treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnrc code for 100, 120, 130, and 140 kVp energies. An in-house graphical user interface called DOSCTP (DOSXYZnrc-based) developed using MATLAB was used to calculate the dose distributions due to a 360 deg. photon arc from the CBCT beam with the same patient CT image sets as used in Pinnacle3. The two calculated dose distributions were added together by setting the CBCT doses equal to 1%, 1.5%, 2%, and 2.5% of the prescription dose of the prostate IMRT. The prostate plan and the summed dose distributions were then processed in the CERR platform to determine the dose-volume histograms (DVHs) of the regions of interest. Moreover, dose profiles along the x- and y-axes crossing the isocenter with and without addition of the CBCT dose were determined. It was found that the added doses due to CBCT are most significant at the femur heads. Higher doses were found at the bones for a relatively low energy CBCT beam such as 100 kVp. Apart from the bones, the CBCT dose was observed to be most concentrated on the anterior and posterior side of the patient anatomy. Analysis of the DVHs for the prostate and other critical tissues showed that they vary only slightly with the added CBCT dose at different beam energies. On the other hand, the changes of the DVHs for the femur heads due to the CBCT dose and beam energy were more significant than those of rectal and bladder wall. By analyzing the vertical and horizontal dose profiles crossing the femur heads and isocenter, with and without the CBCT dose equal to 2% of the prescribed dose, it was found that there is about a 5% increase of dose at the femur head. Still, such an increase in the femur head dose is well below the dose limit of the bone in our IMRT plans. Therefore, under these dose fractionation conditions, it is concluded that, though CBCT causes a higher dose deposited at the bones, there may be no significant effect in the DVHs of critical tissues in the prostate IMRT.