Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Extrinsic fiber-optic Fabry-Perot interferometer sensor for refractive index measurement of optical glass

A simple fiber-optic sensor based on Fabry-Perot interference for refractive index measurement of optical glass is investigated both theoretically and experimentally. A broadband light source is coupled into an extrinsic fiber Fabry-Perot cavity formed by the surfaces of a sensing fiber end and the measured sample. The interference signals from the cavity are reflected back into the same fiber. The refractive index of the sample can be obtained by measuring the contrast of the interference fringes. The experimental data meet with the theoretical values very well. The proposed technique is a new method for glass refractive index measurement with a simple, solid, and compact structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of SRF monolayer/multilayer thin film materials to increase the performance of SRF accelerating structures beyond bulk Nb

The minimization of cost and energy consumption of future particle accelerators, both large and small, depends upon the development of new materials for the active surfaces of superconducting RF (SRF) accelerating structures. SRF properties are inherently a surface phenomenon as the RF only penetrates the London penetration depth ?, typically between 20 and 400 nm depending on the material. The greatest potential for dramatic new performance capabilities lies with methods and materials which deliberately produce the sub-micron-thick critical surface layer in a controlled way. Thus, two opportunities arise for the use of SRF thin ?lms as single layer superconductor or multilayer Superconductor-Insulator-Superconductor structures: SRF properties are inherently a surface phenomenon, and when other technological processes are optimized, the fundamental limit to the maximum supportable RF ?eld amplitude is understood to be the ?eld at which the magnetic ?ux ?rst penetrates into the surface, Hc1. Niobium, the material most exploited for SRF accelerator applications, has Hc1 ? 170 mT, which yields a maximum acceler?ating gradient of less than 50 MV/m. Thus, new materials must be investigated to push this limit to the desired range. Although many compounds have shown higher critical superconducting transition temperature (Tc), their critical ?eld (Hc1) is lower than niobium. To circumvent this issue, a Super?conductor/Insulator/Superconductor (S-I-S) multilayer ?lms approach has been proposed to achieve performance in excess of that of bulk Nb. In this system, the critical ?eld is enhanced and the ?uxon penetration delayed by using, on top of the Nb surface, a superposition of superconductor layers, each less than a penetration depth in thickness, separated by a dielectric layer a few nanometers thick. For bulk type-II superconducting materials, vortex entry occurs at surface magnetic ?eld Hc1. The key aspect of Gurevich's analysis is the recognition that vortex entry is inhibited if the surface layer thick?ness (d) of the superconductor is less than the penetration depth, ?. The overlayer provides magnetic screening of the underlying Nb with the attenuation factor exp(d/ ?0). The Nb surface can remain in the Meissner state at ?elds much higher than in bulk due to the increase of the parallel Hc1 in a thin ?lm. This could potentially lead to further improvement in RF cavity performance using the bene?t of the higher-Tc superconductors without being limited by their lower Hc1. Niobium on copper (Nb/Cu) technology for superconducting cavities has proven over the years to be a viable alternative to bulk niobium. However the deposition techniques used for cavities, mainly magnetron sputtering, have not yielded, so far, SRF surfaces suitable for high ?eld performance. High quality ?lms can be grown using methods of energetic condensation, such as Electron Cy?clotron Resonance (ECR) Nb ion source in UHV and High Power Impulse Magnetron Sputtering (HiP?IMS) with energetic ions only and neutral atoms signi?cantly blocked. The main advantages of these techniques are the production of higher ?ux of ions with controllable incident angle and kinetic energy and the absence of macroparticle production. The project in general, is focusing onto understanding the physics underlying the RF superconduc?tivity in layered structures and developing SRF material ?lms suitable as substrate and S-I-S multilayer structures. In ?rst hand, the primary focus is to understand the physics governing the relationship be?tween growth conditions, ?lm microstructure and RF performance for SRF materials produced by energetic condensation. The deposition by energetic condensation in UHV via ECR and HiPIMS are studied for Nb and B1 superconducting compounds on substrates with various lattice match and sur?face conditions (in-situ etching, high energy assisted atomic annealing, deposition temperature). The general energy-temperature zone model developed by André Anders is explored to de?ne the optimized coating conditions for ?lms suitable for single layer and multilayer SRF structures. The contribution of both the ion incident energy and the substrate lattice energy on the nucleation of the SRF materials considered, and some insulating materials (AlN and MgO) and the in?uence of the coating conditions on the resulting materials, superconducting and/or RF properties will be investigated. Attention is be given to minimize the residual stress (intrinsic and thermal) with the choice of lattice match between the ?lm and substrate materials, the coating temperature, and to evaluate the coating methods used in terms of conformality for 3D structures. In second hand, as a proof of concept, the coating condi?tions developed will be used to prepare multi-layer superconductor/insulator/superconductor (S-I-S) ?lms having high quality factor and high gradient breakthrough potential. A thick Nb ?lm (> 1µm) could be used as a substrate. Particular attention is given to the interface between superconducting and insulator ?lms. For this work, various material analyses techniques have been used to character?ize each type of thin ?lm material: electron backscatter di?raction (EBSD), X-ray di?raction (XRD), high-resolution scanning electron microscopy (SEM), transmission electron microscopy (TEM), stylus and AFM pro?lometry, secondary ion mass spectroscopy (SIMS), scanning auger microscopy (SAM). Superconducting and RF measurements are also performed (RRR, Tc, and low-temperature SRF sur- face impedance, SQUID-magnetometry). The insight gained from this project on the physics involved in RF superconductivity of layered structures open the way to enable major reductions in both capital and operating costs associated with future particle accelerators across the spectrum from low foot?print compact machines to energy frontier facilities. Realization of quality thin ?lm SRF cavities may dramatically change the cost structure of acceleration systems and signi?cantly improve performance consistency and reliability.

VALENTE-FELICIANO, Anne-Marie↗

Comparison of measured and modelled negative hydrogen ion densities at the ECR-discharge HOMER

As the negative hydrogen ion density n{sub H{sup −}} is a key parameter for the investigation of negative ion sources, its diagnostic quantification is essential in source development and operation as well as for fundamental research. By utilizing the photodetachment process of negative ions, generally two different diagnostic methods can be applied: via laser photodetachment, the density of negative ions is measured locally, but only relatively to the electron density. To obtain absolute densities, the electron density has to be measured additionally, which induces further uncertainties. Via cavity ring-down spectroscopy (CRDS), the absolute density of H{sup −} is measured directly, however LOS-averaged over the plasma length. At the ECR-discharge HOMER, where H{sup −} is produced in the plasma volume, laser photodetachment is applied as the standard method to measure n{sub H{sup −}}. The additional application of CRDS provides the possibility to directly obtain absolute values of n{sub H{sup −}}, thereby successfully bench-marking the laser photodetachment system as both diagnostics are in good agreement. In the investigated pressure range from 0.3 to 3 Pa, the measured negative hydrogen ion density shows a maximum at 1 to 1.5 Pa and an approximately linear response to increasing input microwave powers from 200 up to 500 W. Additionally, the volume production of negative ions is 0-dimensionally modelled by balancing H{sup −} production and destruction processes. The modelled densities are adapted to the absolute measurements of n{sub H{sup −}} via CRDS, allowing to identify collisions of H{sup −} with hydrogen atoms (associative and non-associative detachment) to be the dominant loss process of H{sup −} in the plasma volume at HOMER. Furthermore, the characteristic peak of n{sub H{sup −}} observed at 1 to 1.5 Pa is identified to be caused by a comparable behaviour of the electron density with varying pressure, as n{sub e} determines the volume production rate via dissociative electron attachment to vibrationally excited hydrogen molecules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PB-AM: An open-source, fully analytical linear poisson-boltzmann solver

Here, we present the open source distributed software package Poisson-Boltzmann Analytical Method (PB-AM), a fully analytical solution to the linearized PB equation, for molecules represented as non-overlapping spherical cavities. The PB-AM software package includes the generation of outputs files appropriate for visualization using visual molecular dynamics, a Brownian dynamics scheme that uses periodic boundary conditions to simulate dynamics, the ability to specify docking criteria, and offers two different kinetics schemes to evaluate biomolecular association rate constants. Given that PB-AM defines mutual polarization completely and accurately, it can be refactored as a many-body expansion to explore 2- and 3-body polarization. Additionally, the software has been integrated into the Adaptive Poisson-Boltzmann Solver (APBS) software package to make it more accessible to a larger group of scientists, educators, and students that are more familiar with the APBS framework.

97 MATHEMATICS AND COMPUTING↗

Locoregionally Advanced Head and Neck Cancer Treated With Primary Radiotherapy: A Comparison of the Addition of Cetuximab or Chemotherapy and the Impact of Protocol Treatment

Purpose: The addition of platinum-based chemotherapy (ChRT) or cetuximab (ExRT) to concurrent radiotherapy (RT) has resulted in improved survival in Phase III studies for locoregionally advanced head and neck cancer (LAHNC). However the optimal treatment regimen has not been defined. A retrospective study was performed to compare outcomes in patients who were treated definitively with ExRT or ChRT. Methods: Cetuximab with concurrent RT was used to treat 29 patients with LAHNC, all of whom had tumors of the oral cavity, oropharynx, or larynx. All patients were T2 to T4 and overall American Joint Committee on Cancer Stage III to IVB, with a Karnofsky Performance Status (KPS) score of 60 or greater. ChRT was used to treat 103 patients with similar characteristics. Patients were evaluated for locoregional control (LRC), distant metastasis-free survival (DMFS), disease-specific survival (DSS), and overall survival (OS). Median follow-up for patients alive at last contact was 83 months for those treated with ExRT and 53 months for those treated with ChRT. Cox proportional hazard models were used to assess independent prognostic factors. Results: The LRC, DMFS, and DSS were not significantly different, with 3-year rates of 70.7%, 92.4%, and 78.6% for ExRT and 74.7%, 86.6%, and 76.5% for ChRT, respectively. The OS was significantly different between the two groups (p = 0.02), with 3-year rates of 75.9% for ExRT and 61.3% for ChRT. OS was not significant when patients who were on protocol treatments of ExRT or ChRT were compared. Also, OS was not significant when multivariate analysis was used to control for potential confounding factors. Conclusion: In our single-institution retrospective review of patients treated with ExRT or ChRT, no significant differences were found in LRC, DMFS, DSS, or OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning

Purpose: For cranial patients receiving stereotactic radiotherapy, we use the Exactrac stereoscopic X-ray system to optimize patient positioning. Patients are immobilized with the BrainLAB Mask System (BrainLAB, Feldkirchen, Germany). We have developed an adapter to this system that accommodates a vacuum mouth piece (VMP). Measurements with the Exactrac system have been performed to study the positioning accuracy after corrections with this system and to evaluate the accuracy of the VMP vs. the standard available upper jaw support (UJS). Methods and Materials: Positioning results were collected for 20 patients with the UJS and 20 patients with the VMP, before treatment (1,122 fractions) and after treatment (400 fractions). For all 6 degrees of freedom the average, the random error and systematic error were calculated. Results: The average vector length before and after correction with the Exactrac system was 2.1 {+-} 1.2 mm and 0.7 {+-} 0.6 mm respectively for UJS and 1.7 {+-} 0.7 mm and 0.4 {+-} 0.4 mm for VMP. Interfraction positioning for translations was greatly improved after correction with the Exactrac system (p < 0.0005) and is better with VMP than with UJS (p = 0.005). Outliers were greatly reduced. Interfraction rotations were significantly smaller for VMP. Intrafraction errors for vertical and longitudinal translations and for rotations were smaller for the VMP. Conclusions: Positioning correction using the Exactrac X-ray system greatly improves accuracy. Adding the VMP results in even better patient fixation and smaller rotations, making it a useful addition to the Mask System. Combined, this is a convenient and accurate alternative to invasive fixation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Developing one-dimensional implosions for inertial confinement fusion science

Experiments on the National Ignition Facility show that multi-dimensional effects currently dominate the implosion performance. Low mode implosion symmetry and hydrodynamic instabilities seeded by capsule mounting features appear to be two key limiting factors for implosion performance. One reason these factors have a large impact on the performance of inertial confinement fusion implosions is the high convergence required to achieve high fusion gains. To tackle these problems, a predictable implosion platform is needed meaning experiments must trade-off high gain for performance. LANL has adopted three main approaches to develop a one-dimensional (1D) implosion platform where 1D means measured yield over the 1D clean calculation. A high adiabat, low convergence platform is being developed using beryllium capsules enabling larger case-to-capsule ratios to improve symmetry. The second approach is liquid fuel layers using wetted foam targets. With liquid fuel layers, the implosion convergence can be controlled via the initial vapor pressure set by the target fielding temperature. The last method is double shell targets. For double shells, the smaller inner shell houses the DT fuel and the convergence of this cavity is relatively small compared to hot spot ignition. However, double shell targets have a different set of trade-off versus advantages. As a result, details for each of these approaches are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Assessment of Pose Prediction Accuracy in RNA–Ligand Docking

Structure-based virtual high-throughput screening is used in early-stage drug discovery. Over the years, docking protocols and scoring functions for protein–ligand complexes have evolved to improve the accuracy in the computation of binding strengths and poses. In the past decade, RNA has also emerged as a target class for new small-molecule drugs. However, most ligand docking programs have been validated and tested for proteins and not RNA. Here, we test the docking power (pose prediction accuracy) of three state-of-the-art docking protocols on 173 RNA–small molecule crystal structures. The programs are AutoDock4 (AD4) and AutoDock Vina (Vina), which were designed for protein targets, and rDock, which was designed for both protein and nucleic acid targets. AD4 performed relatively poorly. For RNA targets for which a crystal structure of a bound ligand used to limit the docking search space is available and for which the goal is to identify new molecules for the same pocket, rDock performs slightly better than Vina, with success rates of 48% and 63%, respectively. However, in the more common type of early-stage drug discovery setting, in which no structure of a ligand–target complex is known and for which a larger search space is defined, rDock performed similarly to Vina, with a low success rate of ~27%. Further, Vina was found to have bias for ligands with certain physicochemical properties, whereas rDock performs similarly for all ligand properties. Thus, for projects where no ligand–protein structure already exists, Vina and rDock are both applicable. However, the relatively poor performance of all methods relative to protein–target docking illustrates a need for further methods refinement.

59 BASIC BIOLOGICAL SCIENCES↗

Improved finite-difference computation of the van der Waals force: One-dimensional case

We present an improved demonstration of the calculation of Casimir forces in one-dimensional systems based on the recently proposed numerical imaginary frequency Green's function computation approach. The dispersion force on two thick lossy dielectric slabs separated by an empty gap and placed within a perfectly conducting cavity is obtained from the Green's function of the modified Helmholtz equation by means of an ordinary finite-difference method. In order to demonstrate the possibility to develop algorithms to explore complex geometries in two and three dimensions to higher order in the mesh spacing, we generalize existing classical electromagnetism algebraic methods to generate the difference equations for dielectric boundaries not coinciding with any grid points. Diagnostic tests are presented to monitor the accuracy of our implementation of the method and follow-up applications in higher dimensions are introduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser frequency stabilization by dual arm locking for LISA

The Laser Interferometer Space Antenna (LISA) will be the first dedicated space based gravitational wave detector. LISA will consist of a triangular formation of spacecraft, forming an interferometer with 5x10{sup 6} km long arms. Annual length variations of the interferometer arms prevent exact laser frequency noise cancellation. Despite prestabilization to an optical cavity the expected frequency noise is many orders of magnitude larger than the required levels. Arm locking is a feedback control method that will further stabilize the laser frequency by referencing it to the 5x10{sup 6} km arms. Although the original arm locking scheme produced a substantial noise reduction, the technique suffered from slowly decaying start-up transients and excess noise at harmonic frequencies of the inverse round-trip time. Dual arm locking, presented here, improves on the original scheme by combining information from two interferometer arms for feedback control. Compared to conventional arm locking, dual arm locking exhibits significantly reduced start-up transients, no noise amplification at frequencies within the LISA signal band, and more than 50 fold improvement in noise suppression at low frequencies. In this article we present a detailed analysis of the dual arm locking control system and present simulation results showing a noise reduction of 10 000 at a frequency of 10 mHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppressing spectral diffusion of emitted photons with optical pulses

In many quantum architectures the solid-state qubits, such as quantum dots or color centers, are interfaced via emitted photons. However, the frequency of photons emitted by solid-state systems exhibits slow uncontrollable fluctuations over time (spectral diffusion), creating a serious problem for implementation of the photon-mediated protocols. Here we show that a sequence of optical pulses applied to the solid-state emitter can stabilize the emission line at the desired frequency. We demonstrate efficiency, robustness, and feasibility of the method analytically and numerically. Taking nitrogen-vacancy center in diamond as an example, we show that only several pulses, with the width of 1 ns, separated by few ns (which is not difficult to achieve) can suppress spectral diffusion. As a result, our method provides a simple and robust way to greatly improve the efficiency of photon-mediated entanglement and/or coupling to photonic cavities for solid-state qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved quality of intrafraction kilovoltage images by triggered readout of unexposed frames

Purpose: The gantry-mounted kilovoltage (kV) imager of modern linear accelerators can be used for real-time tumor localization during radiation treatment delivery. However, the kV image quality often suffers from cross-scatter from the megavoltage (MV) treatment beam. This study investigates readout of unexposed kV frames as a means to improve the kV image quality in a series of experiments and a theoretical model of the observed image quality improvements. Methods: A series of fluoroscopic images were acquired of a solid water phantom with an embedded gold marker and an air cavity with and without simultaneous radiation of the phantom with a 6 MV beam delivered perpendicular to the kV beam with 300 and 600 monitor units per minute (MU/min). An in-house built device triggered readout of zero, one, or multiple unexposed frames between the kV exposures. The unexposed frames contained part of the MV scatter, consequently reducing the amount of MV scatter accumulated in the exposed frames. The image quality with and without unexposed frame readout was quantified as the contrast-to-noise ratio (CNR) of the gold marker and air cavity for a range of imaging frequencies from 1 to 15 Hz. To gain more insight into the observed CNR changes, the image lag of the kV imager was measured and used as input in a simple model that describes the CNR with unexposed frame readout in terms of the contrast, kV noise, and MV noise measured without readout of unexposed frames. Results: Without readout of unexposed kV frames, the quality of intratreatment kV images decreased dramatically with reduced kV frequencies due to MV scatter. The gold marker was only visible for imaging frequencies ≥3 Hz at 300 MU/min and ≥5 Hz for 600 MU/min. Visibility of the air cavity required even higher imaging frequencies. Readout of multiple unexposed frames ensured visibility of both structures at all imaging frequencies and a CNR that was independent of the kV frame rate. The image lag was 12.2%, 2.2%, and 0.9% in the first, second, and third frame after an exposure. The CNR model predicted the CNR with triggered image readout with a mean absolute error of 2.0% for the gold marker. Conclusions: A device that triggers readout of unexposed frames during kV fluoroscopy was built and shown to greatly improve the quality of intratreatment kV images. A simple theoretical model successfully described the CNR improvements with the device.

60 APPLIED LIFE SCIENCES↗

Statistics of discrete photodetection of resonance fluorescence in the Mollow sidebands

A method is proposed for generating conditional single-photon states with a high degree of purity in a single-mode cavity by successive discrete photodetection. The cavity is pumped by resonance fluorescence emission from a source atom driven by a classical field. The cavity is tuned to a Mollow sideband. A relation between detector parameters is found that makes it possible to interpret the detection of a probe atom in the excited state as unambiguous evidence that a pure single-photon state has been prepared in the cavity. An expression is derived for the prior probability of such an event, and dependence of the one-photon state population of the cavity field on detuning, relaxation rate, and time is examined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multichannel television coupling modulation experiments using a CO2 laser.

Experiments are described in which a carbon dioxide laser oscillating at 28.4 THz has been modulated simultaneously by three commercial television signals with carriers at 54, 66, and 82 MHz. Signal-to-noise degradation in the system was measured to be less than 1 dB, corresponding to modulator drive power of 1 W. This combination of wide bandwidth and low power consumption was made possible by the application of coupling modulation. This technique employs an intracavity electrooptic crystal to which the modulating fields are applied. Despite the fact that the crystal is positioned inside the laser cavity, the maximum bandwidth attainable is independent of both the cavity Q and the laser transition linewidth, and is limited only by modulator characteristics and optical transit time. Rigrod's (1965) method has been adapted to obtain an expression for the power coupled out of the laser. Modulator frequency response and drive power requirements are also summarized. It is seen that the noise bandwidth performance of the system would allow simultaneous modulation by 17 color television channels, or equivalently, more than a 300-megabit/sec capacity.

Hall, D. R.↗

The momentum transfer of incompressible turbulent separated flow due to cavities with steps

An experimental study was conducted using a plate test bed having a turbulent boundary layer to determine the momentum transfer to the faces of step/cavity combinations on the plate. Experimental data were obtained from configurations including an isolated configuration and an array of blocks in tile patterns. A momentum transfer correlation model of pressure forces on an isolated step/cavity was developed with experimental results to relate flow and geometry parameters. Results of the experiments reveal that isolated step/cavity excrecences do not have a unique and unifying parameter group due in part to cavity depth effects and in part to width parameter scale effects. Drag predictions for tile patterns by a kinetic pressure empirical method predict experimental results well. Trends were not, however, predicted by a method of variable roughness density phenomenology.

White, R. E.↗

Effect of grazing flow on the nonlinear acoustic behavior of helmholtz resonators

A semi empirical fluid mechanical model is derived of the acoustic behavior of thin walled single orifice Helmholtz resonators in a grazing flow environment. The model assumes that the flow field incident to a resonator orifice consists of a spherical sound particle velocity field superimposed upon a mean grazing flow. The incident and cavity sound fields are connected in terms of an orifice discharge coefficient whose values are determined experimentally using the two microphone method. With regard to its application to rocket motor interiors, the most important finding of this study is that the acoustic impedance of Helmholtz resonators is affected by grazing flow when the product of the amplitude of the sound pressure incident to the resonator orifice and the rocket motor interior mean grazing flow speed are less than 0.5. For values greater than 0.5, the acoustic impedance is independent of the grazing flow.

Hersh, A. S.↗