Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Methodology for Mechanical Property Testing on Fuel Cladding Using an Expanded Plug Wedge Test

To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at ORNL and is described fully in US Patent Application 20060070455, Expanded plug method for developing circumferential mechanical properties of tubular materials. This method is designed for testing fuel rod cladding ductility in a hot cell utilizing an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the test component assembly in the hot cell and the direct measurement of specimen strain. It was also found that cladding strength could be determined from the test results. The basic approach of this test method is to apply an axial compressive load to a cylindrical plug of polyurethane (or other materials) fitted inside a short ring of the test material to achieve radial expansion of the specimen. The diameter increase of the specimen is used to calculate the circumferential strain accrued during the test. The other two basic measurements are total applied load and amount of plug compression (extension). A simple procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves. However, several deficiencies exist in this expanded-plug loading ring test, which will impact accuracy of test results and introduce potential shear failure of the specimen due to inherited large axial compressive stress from the expansion plug test. First of all, the highly non-uniform stress and strain distribution resulted in the gage section of the clad. To ensure reliable testing and test repeatability, the potential for highly non-uniform stress distribution or displacement/strain deformation has to be eliminated at the gage section of the specimen. Second, significant compressive stresses were induced by clad bending deformation due to a clad bulging effect (or the barreling effect). The barreling effect caused very large localized shear stress in the clad and left testing material at a high risk of shear failure. The above combined effects will result in highly non-conservative predictions both in strength and ductility of the tested clad, and the associated mechanical properties as well. To overcome/mitigate the mentioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. Through detailed parameter investigation on specific geometry designs, careful filtering of material for the expansion plug, as well as adding newly designed parts to the testing system, a method to reconcile the potential non-conservatism embedded in the expansion plug test system has been discovered. A modified expansion plug testing protocol has been developed based on the method. In order to closely resemble thin-wall theory, a general procedure was also developed to determine the hoop stress $\sigma_\theta$ in the tested ring specimen. A scaling factor called $\chi$-factor is defined to correlate the ring load F ring into hoop stress $\sigma_\theta$, and written as $\sigma_\theta = \chi \frac{F_{ring}} {tl}$. The generated stress-strain curve agrees very well with tensile test data in both the elastic and plastic regions.

expansion plug test↗

Tagged DVCS on neutron with the CLAS12 Experiment and the detector BONuS12 at Jefferson Lab (USA)

Hadronic physics studies the properties of the proton and neutron. The theory of Quantum Chromodynamics (QCD) governs the structure of hadrons. Non-perturbative structure functions are used to describe the hadrons? structure. Generalized Parton Distributions (GPDs) are a set of structure functions providing access to a 3D view of the nucleon. GPDs contain information about the longitudinal momentum and transverse position of quarks and their correlation. They are related to the spin structure and play a role in solving the proton spin puzzle. They provide access to the quarks? orbital angular momentum, a crucial puzzle piece. For this, measurements on the proton, already present, and neutron are necessary. This thesis aims to explore Compton scattering on the neutron with a deuterium target by measuring the spectator proton with the CLAS12 detector and the BONuS12 RTPC at Jefferson Lab. This work first describes the implementation, which I carried out, of a Kalman filter to reconstruct spectator protons in the BONuS12 detector. The second part of the manuscript is dedicated to the work on the analysis of DVCS on the neutron with the subtraction of background noises. Two different methods for the subtraction of ?0 will be detailed. Finally, the obtained results are presented and discussed

Ouillon, Mathieu↗

On the Origin of Charge Generation in Hybrid TiOx/Conjugated Polymer Photovoltaic Devices

Hybrid films of donor/acceptor conjugated polymer/metal oxides are considered promising materials for low-cost, solution-processed solar cells. Because device performances depend on the nanoscale film morphologies, most attention and extensive efforts have been invested in improving the nanofabrication of hybrid films. Nevertheless, the reported conjugated polymer/metal oxide device efficiencies are still far poorer than those of all-organic and solid-state dye-sensitized metal oxide solar cells. To decouple the effect of insufficient morphology control from other generic photocurrent-limiting processes, we study the photocurrent generation at conjugated polymer-metal oxide interfaces in self-organized, highly ordered, and uniform hybrid nanostructures. A combination of small-angle X-ray scattering, high-resolution transmission electron microscopy (TEM), and energy-filtered TEM confirms the structure and composition of the highly ordered, high interfacial area hybrid cubic mesostructured films prepared by the coassembly of a titania precursor species, a water-soluble polythiophene derivative, and a block copolymer surfactant. Contactless time-resolved microwave photoconductivity (TRMC) measurements show a moderate 2-fold increase in the photoconductivity of the highly ordered TiO{sub x}/conjugated polymer mesostructured film compared to that of a pristine film of the same polymer, indicating inefficient exciton dissociation at the oxide/polymer interface. Furthermore, strong correlation between the TRMC results and the device performance reveals that most of the photogenerated carriers in the conjugated polymer/TiO{sub x} photovoltaic device originate from exciton dissociation in the polymer bulk, followed by electron transfer from the polymer to the metal oxide, and not at the interface. Therefore, the photovoltaic devices utilizing the highly ordered conjugated polymer/metal oxide mesostructured films are not primarily limited by insufficient morphology control but rather by the inefficient process of exciton dissociation in the polymer. This observation is in agreement with the low photocurrent densities generally observed in photovoltaic devices comprising conjugated polymer/metal oxide active layers.

14 SOLAR ENERGY↗

GRB 110709A, 111117A, AND 120107A: FAINT HIGH-ENERGY GAMMA-RAY PHOTON EMISSION FROM FERMI-LAT OBSERVATIONS AND DEMOGRAPHIC IMPLICATIONS

Launched on 2008 June 11, the Large Area Telescope (LAT) instrument on board the Fermi Gamma-ray Space Telescope has provided a rare opportunity to study high-energy photon emission from gamma-ray bursts (GRBs). Although the majority of such events (27) have been identified by the Fermi-LAT Collaboration, four were uncovered by using more sensitive statistical techniques. In this paper, we continue our earlier work by finding three more GRBs associated with high-energy photon emission, GRB 110709A, 111117A, and 120107A. To systematize our matched filter approach, a pipeline has been developed to identify these objects in nearly real time. GRB 120107A is the first product of this analysis procedure. Despite the reduced threshold for identification, the number of GRB events has not increased significantly. This relative dearth of events with low photon number prompted a study of the apparent photon number distribution. We find an extremely good fit to a simple power law with an exponent of -1.8 {+-} 0.3 for the differential distribution. As might be expected, there is a substantial correlation between the number of lower energy photons detected by the Gamma-ray Burst Monitor (GBM) and the number observed by LAT. Thus, high-energy photon emission is associated with some but not all of the brighter GBM events. Deeper studies of the properties of the small population of high-energy emitting bursts may eventually yield a better understanding of these entire phenomena.

79 ASTRONOMY AND ASTROPHYSICS↗

THE ACS SURVEY OF GLOBULAR CLUSTERS. XIII. PHOTOMETRIC CALIBRATION IN COMPARISON WITH STETSON STANDARDS

In this study we compare the photometric data of 34 Milky Way globular clusters, observed within the Advanced Camera for Surveys (ACS) Treasury Program (PI: A. Sarajedini) with the corresponding ground-based data, provided by the Photometric Standard Field Catalogs of Stetson. We focus on the transformation between the Hubble Space Telescope/ACS F606W to V-band and F814W to I-band only. The goal is to assess the validity of the filter transformation equations by Sirianni et al. with respect to their dependence on metallicity, horizontal branch morphology, mass, and integrated (V – I) color of the various globular clusters. The transformation equations as recommended by Sirianni et al. are based on synthetic photometry, were mostly tested on NGC 2419, and may introduce additional uncertainties when applied to different stellar populations. Such a dependence is expected due to the fact that the transformation equations are based on the observations of only one globular cluster, i.e., NGC 2419. Surprisingly, the correlation between offset and metallicity is found to be weak, with a low level significance. The correlation between offset and horizontal branch structure, as well as total cluster mass is still weaker. Based on the available data we do not find the photometric offset to be linked to multiple stellar populations, e.g., as found in NGC 0288, NGC 1851, and NGC 5139. The results of this study show that there are small systematic offsets between the transformed ACS- and observed ground-based photometry, and that these are only weakly correlated, if at all, with various cluster parameters and their underlying stellar populations. As a result, investigators wishing to transform globular cluster photometry from the Sirianni et al. ground-based V, I system onto the Stetson system simply need to add –0.040 (±0.012) to the V magnitudes and –0.047 (±0.011) to the I magnitudes. This in turn means that the transformed ACS V – I colors match the ground-based values from Stetson to within ∼0.01 mag.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing weak lensing mass estimates for cluster profile uncertainty

Weak lensing measurements of cluster masses are necessary for calibrating mass-observable relations (MORs) to investigate the growth of structure and the properties of dark energy. However, the measured cluster shear signal varies at fixed mass M 200m due to inherent ellipticity of background galaxies, intervening structures along the line of sight, and variations in the cluster structure due to scatter in concentrations, asphericity and substructure. We use N-body simulated halos to derive and evaluate a weak lensing circular aperture mass measurement M ap that minimizes the mass estimate variance <(M ap - M 200m ) 2 > in the presence of all these forms of variability. Depending on halo mass and observational conditions, the resulting mass estimator improves on M ap filters optimized for circular NFW-profile clusters in the presence of uncorrelated large scale structure (LSS) about as much as the latter improve on an estimator that only minimizes the influence of shape noise. Optimizing for uncorrelated LSS while ignoring the variation of internal cluster structure puts too much weight on the profile near the cores of halos, and under some circumstances can even be worse than not accounting for LSS at all. As a result, we discuss the impact of variability in cluster structure and correlated structures on the design and performance of weak lensing surveys intended to calibrate cluster MORs.

79 ASTRONOMY AND ASTROPHYSICS↗

Suppression of biodynamic interference in head-tracked teleoperation

The utility of helmet-tracked sights to provide pointing commands for teleoperation of cameras, lasers, or antennas in aircraft is degraded by the presence of uncommanded, involuntary heat motion, referred to as biodynamic interference. This interference limits the achievable precision required in pointing tasks. The noise contributions due to biodynamic interference consists of an additive component which is correlated with aircraft vibration and an uncorrelated, nonadditive component, referred to as remnant. An experimental simulation study is described which investigated the improvements achievable in pointing and tracking precision using dynamic display shifting in the helmet-mounted display. The experiment was conducted in a six degree of freedom motion base simulator with an emulated helmet-mounted display. Highly experienced pilot subjects performed precision head-pointing tasks while manually flying a visual flight-path tracking task. Four schemes using adaptive and low-pass filtering of the head motion were evaluated to determine their effects on task performance and pilot workload in the presence of whole-body vibration characteristic of helicopter flight. The results indicate that, for tracking tasks involving continuously moving targets, improvements of up to 70 percent can be achieved in percent on-target dwelling time and of up to 35 percent in rms tracking error, with the adaptive plus low-pass filter configuration. The results with the same filter configuration for the task of capturing randomly-positioned, stationary targets show an increase of up to 340 percent in the number of targets captured and an improvement of up to 24 percent in the average capture time. The adaptive plus low-pass filter combination was considered to exhibit the best overall display dynamics by each of the subjects.

Lifshitz, S.↗

An Experimental Study of the Flow Emerging from Porous Walls

The fluid mechanics of air flow exiting from porous materials is investigated. Porous walls with filter ratings differing by about three orders of magnitude are studied. The flow behavior is investigated for its spatial and temporal stability. The measurements show that coalescence effects cause jet development which gives rise to a stable, spatial velocity non-uniformity termed pseudo-turbulence. Beyond a critical mean velocity, the pseudo-turbulence shows a leveling trend and the flow exhibits jets whose dimensions are independent of wall porosity and provide a unique length scale for this type of flow field (approx. 1 mm). A correlation is developed to predict the onset of fully developed jets. The impact of using porous wall materials in cold flow solid rocket motor testing is addressed.

Ramachandran, N.↗

Compact and multi-view solid state neutral particle analyzer arrays on National Spherical Torus Experiment-Upgrade

A compact and multi-view Solid State Neutral Particle Analyzer (SSNPA) diagnostic based on silicon photodiode arrays has been successfully tested on the National Spherical Torus Experiment-Upgrade (NSTX-U). The SSNPA diagnostic provides spatially, temporally, and pitch-angle resolved measurements of fast-ion distribution by detecting fast neutral flux resulting from charge exchange (CX) reactions. The system consists of three 16-channel subsystems: t-SSNPA viewing the plasma mid-radius and neutral beam (NB) line #2 tangentially, r-SSNPA viewing the plasma core and NB line #1 radially and p-SSNPA with no intersection with any NB lines. Due to the setup geometry, the active CX signals of t-SSNPA and r-SSNPA are mainly sensitive to passing and trapped particles respectively. In addition, both t-SSNPA and r-SSNPA utilize three vertically stacked arrays with different filter thickness to obtain coarse energy information. The experimental data show that all channels are operational. The signal to noise ratio is typically larger than 10 and the main noise is x-ray induced signal. The active and passive CX signals are clearly observed on t-SSNPA and r-SSNPA during NB modulation. The SSNPA data also indicate significant losses of passing particles during sawteeth, while trapped particles are weakly affected. Fluctuations up to 120 kHz, have been observed on SSNPA, and they are strongly correlated with magnetohydrodynamics (MHD) instabilities.

Charge exchange neutral particle fast ion distribu↗

Compact Radar Transceiver with Included Calibration

The Digital Beamforming Synthetic Aperture Radar (DBSAR) is an eight-channel phased array radar system that employs solid-state radar transceivers, a microstrip patch antenna, and a reconfigurable waveform generator and processor unit. The original DBSAR transceiver design utilizes connectorized electronic components that tend to be physically large and heavy. To achieve increased functionality in a smaller volume, PCB (printed circuit board) transceivers were designed to replace the large connectorized transceivers. One of the most challenging problems designing the transceivers in a PCB format was achieving proper performance in the calibration path. For a radar loop-back calibration path, a portion of the transmit signal is coupled out of the antenna feed and fed back into the receiver. This is achieved using passive components for stability and repeatability. Some signal also leaks through the receive path. As these two signal paths are correlated via an unpredictable phase, the leakage through the receive path during transmit must be 30 dB below the calibration path. For DBSAR s design, this requirement called for a 100-dB isolation in the receiver path during transmit. A total of 16 solid-state L-band transceivers on a PCB format were designed. The transceivers include frequency conversion stages, T/R switching, and a calibration path capable of measuring the transmit power-receiver gain product during transmit for pulse-by-pulse calibration or matched filtering. In particular, this calibration path achieves 100-dB isolation between the transmitted signal and the low-noise amplifier through the use of a switching network and a section of physical walls achieving attenuation of radiated leakage. The transceivers were designed in microstrip PCBs with lumped elements and individually packaged components for compactness. Each transceiver was designed on a single PCB with a custom enclosure providing interior walls and compartments to isolate transceiver subsystems from radiated interference. The enclosure also acts as a heat sink for the voltage regulators and power amplifiers inside the system. The PCB transceiver design produces transmit pulses of 2 W with an arbitrary duty cycle. Each transceiver is fed by an external 120-MHz signal transmit and two 1,140-MHz local oscillator signals. The received signal is amplified and down-converted to 120 MHz and is fed to the data processor. The transceiver dimensions are approximately 3.5 11.5 0.6 in. (9 29 1.5 cm). The PCB transceiver design reduces the volume and weight of the DBSAR instrument while maintaining the functionality found in the original design. Both volume and weight are critical for airborne and flight remote sensing instrumentation.

McLinden, Matthew↗

Spatiotemporal Pattern Recognition in the PMU Signals in the WECC system

Phasor measurement unit (PMU) data has been used by multiple power system applications, including state estimation, post event analysis, oscillation detection, model validation, and many others. Still, due to its big data nature and availability to general research institutions, comprehensive understanding of the spatiotemporal patterns and underlying mechanisms are incomplete. This study applies a set of signal processing and machine learning approaches aiming at deciphering the characteristic behaviors of multiple phasor measurement units (PMUs) attributes (e.g., voltage, frequency, rate of change of frequency, phase angle), including their auto-correlation, cross-dependence, similarities and discrepancies across units and temporal scales, and distributions of anomalies and their linkages to potential external factors such as weather events. Data analytics are applied to PMUs from the U.S. Western Electricity Coordinating Council (WECC) system. The PMU measurements, recorded events, outages, and weather extremes are all from real world datasets. The findings from the study and mechanistic understanding of the PMU dynamics help provide guidance on system control or preventing blackouts. The derived metrics can be directly used for adjusting or filtering simulated PMU data used for advanced algorithm development.

Hou, Zhangshuan↗

Verification of plutonium content in spent fuel assemblies using neutron self-interrogation

The large amounts of plutonium in reactor spent fuel assemblies has led to increased research directed toward the measurement of the plutonium for safeguards verification. The high levels of fission product gamma-ray activity and curium neutron backgrounds have made the plutonium measurement difficult. We have developed a new technique that can directly measure both the {sup 235}U concentration and the plutonium fissile concentration using the intrinsic neutron emission fronl the curium in the fuel assembly. The passive neutron albedo reactivity (PNAR) method has been described previously where the curium neutrons are moderated in the surrounding water and reflect back into the fuel assembly to induce fissions in the fissile material in the assembly. The cadmium (Cd) ratio is used to separate the spontaneous fission source neutrons from the reflected thermal neutron fission reactions. This method can measure the sum of the {sup 235}U and the plutonium fissile mass, but not the separate components. Our new differential die-away self-interrogation method (DDSI) can be used to separate the {sup 235}U from the {sup 239}Pu. The method has been applied to both fuel rods and full assemblies. For fuel rods the epi-thermal neutron reflection method filters the reflected neutrons through thin Cd filters so that the reflected neutrons are from the epi-cadmium energy region. The neutron fission energy response in the epi-cadmium region is distinctly different for {sup 235}U and {sup 239}Pu. We are able to measure the difference between {sup 235}U and {sup 239}Pu by sampling the neutron induced fission rate as a function of time and multiplicity after the initial fission neutron is detected. We measure the neutron fission rate using list-mode data collection that stores the time correlations between all of the counts. The computer software can select from the data base the time correlations that include singles, doubles, and triples. The die-away time for the doubles distribution is distinctly different for {sup 235}U and {sup 239}Pu. The {sup 239}Pu has a higher fission cross-section in the epi-cadmium neutron region and larger induced fission moments than {sup 235}U, so the measured die-away time can provide the relative amounts of {sup 239}Pu and {sup 235}U. This paper will present the Monte Carlo simulations for the detector and sample configurations for both fuel pins and full fuel assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Smoothing of respiratory motion traces for motion-compensated radiotherapy

Purpose: The CyberKnife system has been used successfully for several years to radiosurgically treat tumors without the need for stereotactic fixation or sedation of the patient. It has been shown that tumor motion in the lung, liver, and pancreas can be tracked with acceptable accuracy and repeatability. However, highly precise targeting for tumors in the lower abdomen, especially for tumors which exhibit strong motion, remains problematic. Reasons for this are manifold, like the slow tracking system operating at 26.5 Hz, and using the signal from the tracking camera ''as is''. Since the motion recorded with the camera is used to compensate for system latency by prediction and the predicted signal is subsequently used to infer the tumor position from a correlation model based on x-ray imaging of gold fiducials around the tumor, camera noise directly influences the targeting accuracy. The goal of this work is to establish the suitability of a new smoothing method for respiratory motion traces used in motion-compensated radiotherapy. The authors endeavor to show that better prediction--With a lower rms error of the predicted signal--and/or smoother prediction is possible using this method. Methods: The authors evaluated six commercially available tracking systems (NDI Aurora, PolarisClassic, Polaris Vicra, MicronTracker2 H40, FP5000, and accuTrack compact). The authors first tracked markers both stationary and while in motion to establish the systems' noise characteristics. Then the authors applied a smoothing method based on the a trous wavelet decomposition to reduce the devices' noise level. Additionally, the smoothed signal of the moving target and a motion trace from actual human respiratory motion were subjected to prediction using the MULIN and the nLMS{sub 2} algorithms. Results: The authors established that the noise distribution for a static target is Gaussian and that when the probe is moved such as to mimic human respiration, it remains Gaussian with the exception of the FP5000 and the Aurora systems. The authors also showed that the proposed smoothing method can indeed be used to filter noise. The signal's jitter dropped by as much as 95% depending on the tracking system employed. Subsequently, the 3D prediction error (rms) for a prediction horizon of 150 ms on a synthetic signal dropped by up to 37% when using a normalized LMS prediction algorithm (nLMS{sub 2}) and hardly changed when using a MULIN algorithm. When smoothing a real signal obtained in our laboratory, the improvement of prediction was similar: Up to 30% for both the nLMS{sub 2} and the best MULIN algorithm. The authors also found a noticeable increase in smoothness of the predicted signal, the relative jitter dropped by up to 95% on the real signal, and on the simulated signal. Conclusions: In conclusion, the authors can say that preprocessing of marker data is very useful in motion-compensated radiotherapy since the quality of prediction increases. This will result in better performance of the correlation model. As a side effect, since the prediction of a preprocessed signal is also less noisy, the authors expect less robot vibration resulting in better targeting accuracy and less strain on the robot gears.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fish scale deformation analysis using scanning electron microscope: New potential biomarker in aquatic environmental monitoring of aluminum and iron contamination

Fish scale has the potential to be a rapid biomarker due to its structure and high possibility to come into contact with any pollutant in the aquatic environment. The scale structure consists of osteoblastic cells and other bone materials such as collagen where it is possible to form a molecular complex with heavy metals such as aluminum and iron. Hence, aluminum and iron in water could possibly destroy the scale material and marked as a scale deformation that quantitatively could be analyzed by comparing it to the normal scale structure. Water sampling and fish cage experiment were performed between June and July 2011 in Porong river which represented the water body that has high aluminum and iron contamination. The filtered water samples were preserved and extracted using the acid-mixture procedure prior to measurement of the aluminum and iron concentrations using Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), while samples for total suspended solid (TSS) analysis were kept at 4 °C in cool-boxes. The scales were cleaned with sterile water, then dehydrated in 30, 50, 70, and 90% ethanol and dried on filter papers. They were then mounted on an aluminum stub and coated with gold in a sputter coater prior to Scanning Electron Microscope (SEM) observation. According to the SEM analysis, it was found that there were several deformations on the scale samples taken from sites that have high concentrations of aluminum and iron i.e. the increasing number of pits, deformation and decreasing number of spherules and ridges while the control scale exhibited the normal features. However, the site with higher TSS and pH indicated lower aluminum effect. A moderate correlation was found between the number of pits with aluminum (r=0.43) and iron (r=0.41) concentrations. Fish scale deformation using SEM analysis can potentially be a rapid biomarker in aquatic monitoring of aluminum and iron contamination. However, the measurement must be accompanied by pH and TSS observations.

36 MATERIALS SCIENCE↗

Optimal interpolation and the Kalman filter

The estimation theory of stochastic-dynamic systems is described and used in a numerical study of optimal interpolation. The general form of data assimilation methods is reviewed. The Kalman-Bucy, KB filter, and optimal interpolation (OI) filters are examined for effectiveness in performance as gain matrices using a one-dimensional form of the shallow-water equations. Control runs in the numerical analyses were performed for a ten-day forecast in concert with the OI method. The effects of optimality, initialization, and assimilation were studied. It was found that correct initialization is necessary in order to localize errors, especially near boundary points. Also, the use of small forecast error growth rates over data-sparse areas was determined to offset inaccurate modeling of correlation functions near boundaries.

Cohn, S.↗

Imaging Asteroid 4 Vesta Using the Framing Camera

The Framing Camera (FC) onboard the Dawn spacecraft serves a dual purpose. Next to its central role as a prime science instrument it is also used for the complex navigation of the ion drive spacecraft. The CCD detector with 1024 by 1024 pixels provides the stability for a multiyear mission and its high requirements of photometric accuracy over the wavelength band from 400 to 1000 nm covered by 7 band-pass filters. Vesta will be observed from 3 orbit stages with image scales of 227, 63, and 17 m/px, respectively. The mapping of Vesta s surface with medium resolution will be only completed during the exit phase when the north pole will be illuminated. A detailed pointing strategy will cover the surface at least twice at similar phase angles to provide stereo views for reconstruction of the topography. During approach the phase function of Vesta was determined over a range of angles not accessible from earth. This is the first step in deriving the photometric function of the surface. Combining the topography based on stereo tie points with the photometry in an iterative procedure will disclose details of the surface morphology at considerably smaller scales than the pixel scale. The 7 color filters are well positioned to provide information on the spectral slope in the visible, the depth of the strong pyroxene absorption band, and their variability over the surface. Cross calibration with the VIR spectrometer that extends into the near IR will provide detailed maps of Vesta s surface mineralogy and physical properties. Georeferencing all these observation will result in a coherent and unique data set. During Dawn s approach and capture FC has already demonstrated its performance. The strong variation observed by the Hubble Space Telescope can now be correlated with surface units and features. We will report on results obtained from images taken during survey mode covering the whole illuminated surface. Vesta is a planet-like differentiated body, but its surface gravity and escape velocity are comparable to those of other asteroids and hence much smaller than those of the inner planets or

Keller, H. Uwe↗

Miniaturized Gas Correlation Radiometer for the Detection of Trace Gases in the Martian Atmosphere

We present a miniaturized and simplified version of a gas correlation radiometer (GCR) capable of simultaneously mapping multiple trace gases and identifying active regions on the Mars surface. Gas correlation radiometry (GCR) has been shown to be a sensitive and versatile method for detecting trace gases in Earth's atmosphere. Reduction of the size and mass of the GCR was achieved by implementing compact, light-weight 1 mm inner diameter hollow-core optical fibers (hollow waveguides) as the gas correlation cells. In a comparison with an Earth orbiting CO2 GCR instrument, exchanging the 10 m multipass cells with hollow waveguide gas correlation cells of equivalent path length reduces the mass from approximately 150 kg to approximately 0.5 kg, and reduces the volume from 1.9 m x 1.3 m x 0.86 m to a small bundle of fiber coils approximately 1 meter in diameter by 0.05 m in height (mass and volume reductions of greater than 99%). A unique feature of this instrument is its stackable module design, with a single module for each trace gas. Each of the modules is self-contained, and fundamentally identical; differing by the bandpass filter wavelength range and gas mixtures inside the hollow-waveguide absorption cells. The current configuration contains four stacked modules for simultaneous measurements of methane (CH4), formaldehyde (H2CO), water vapor (H2O), and deuterated water vapor (HDO) but could easily be expanded to include measurements of additional species of interest including nitrous oxide (N2O), hydrogen sulfide (H2S), methanol (CH3OH), and sulfur dioxide (SO2), as well as carbon dioxide (CO2) for a simultaneous measure of mass balance. Preliminary results indicate that a 1 ppb detection limit is possible for both formaldehyde and methane with one second of averaging. Using non-optimized components, we have demonstrated an instrument sensitivity equivalent to approximately 30 ppb for formaldehyde, and approximately 500 ppb for methane. We expect custom bandpass filters and 6 m long waveguides to significantly improve these promising results. Ongoing testing is being conducted on water vapor and deuterated water vapor.

Melroy, Hilary R.↗

Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings

A substantial fraction of HVAC energy use in large commercial buildings is due to fan operation. Fan energy use depends in part on the relationship between system pressure drop and flow through the fan, which is commonly called a "system curve." As a step toward enabling better selections of air-handling system components and analyses of common energy efficiency measures such as duct static pressure reset and duct leakage sealing, this paper shows that a simple four-parameter physical model can be used to define system curves. Our model depends on the square of the fan flow, as is commonly considered. It also includes terms that account for linear-like flow resistances such as filters and coils, and for supply duct leakage when damper positions are fixed or are changed independently of static pressure or fan flow. Only two parameters are needed for systems with variable-position supply dampers (e.g., VAV box dampers modulating to control flow). For these systems, reducing or eliminating supply duct leakage does not change the system curve. The parametric system curve may be most useful when applied to field data. Non-linear techniques could be used to fit the curve to fan pressure rise and flow measurements over a range of operating conditions. During design, when measurements are unavailable, one could use duct design calculation tools instead to determine the coefficients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗