Worldwide benchmarking of cost-effective radiometers for direct and diffuse irradiance

Solar energy projects can benefit from direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) measurements during all project phases. Several commercial measurement systems for DNI and DHI are available. Sun trackers with pyranometers and pyrheliometers can provide highly accurate measurements but are often impractical in solar energy applications. For less expensive and more robust sensors, it is often unclear which accuracy can be expected under a project site's specific atmospheric conditions. We address this challenge through our dedicated experimental comparison of relevant sensor systems (rotating shadowband irradiometer [short RSI], Delta-T SPN1, EKO MS-90, PyranoCam, Sunto CaptPro, Kipp & Zonen CSD3) at up to six sites worldwide. The RSI systems (rRMSD 3 to 8.6%, DNI; 4.8 to 7.6%, DHI) and PyranoCam (rRMSD 2.6 to 5.2%, DNI; 4.4 to 5.8%, DHI) exhibit similar error metrics and are the most accurate systems in the test. Delta-T SPN1 and EKO MS-90 (rRMSD 6.8 to 15%, DNI; 10.6 to 20.1%, DHI) but especially Kipp & Zonen CSD3 and Sunto CaptPro show significant deviations (rRMSD 17.7 to 20%, DNI; 33 to 58%, DHI). We evaluate the influence of relevant atmospheric parameters on the sensors' accuracies by a rather unique measurement setup. MS-90's DNI errors depend on DNI itself, with overestimations for low reference DNI. The deviations of SPN1's DHI and DNI measurements increase sharply in situations with high circumsolar irradiance. Also CaptPro and CSD3's increased measurement errors are related to circumsolar irradiance. For RSI and PyranoCam, only moderate influences on the measurements are identified, indicating a general applicability of these instruments.

14 SOLAR ENERGY↗

Measuring and modeling of binary mixture effects of pharmaceuticals and nickel on cell viability/cytotoxicity in the human hepatoma derived cell line HepG2

The interaction of drugs and non-therapeutic xenobiotics constitutes a central role in human health risk assessment. Still, available data are rare. Two different models have been established to predict mixture toxicity from single dose data, namely, the concentration addition (CA) and independent action (IA) model. However, chemicals can also act synergistic or antagonistic or in dose level deviation, or in a dose ratio dependent deviation. In the present study we used the MIXTOX model (EU project ENV4-CT97-0507), which incorporates these algorithms, to assess effects of the binary mixtures in the human hepatoma cell line HepG2. These cells possess a liver-like enzyme pattern and a variety of xenobiotic-metabolizing enzymes (phases I and II). We tested binary mixtures of the metal nickel, the anti-inflammatory drug diclofenac, and the antibiotic agent irgasan and compared the experimental data to the mathematical models. Cell viability was determined by three different methods the MTT-, AlamarBlue (registered) and NRU assay. The compounds were tested separately and in combinations. We could show that the metal nickel is the dominant component in the mixture, affecting an antagonism at low-dose levels and a synergism at high-dose levels in combination with diclofenac or irgasan, when using the NRU and the AlamarBlue assay. The dose-response surface of irgasan and diclofenac indicated a concentration addition. The experimental data could be described by the algorithms with a regression of up to 90%, revealing the HepG2 cell line and the MIXTOX model as valuable tool for risk assessment of binary mixtures for cytotoxic endpoints. However the model failed to predict a specific mode of action, the CYP1A1 enzyme activity.

60 APPLIED LIFE SCIENCES↗

Identifying geological structures through microseismic cluster and burst analyses complementing active seismic interpretation

At the Decatur carbon capture and storage site (IL, USA) CO 2 has been injected from 2011–2014 and from 2017 to present near the base of the Lower Mt. Simon Sandstone saline reservoir, resulting in microseismicity. Microseismicity is mainly located in the basement and distributed in distinct spatial clusters. The lack of significant impedance contrasts within the basement makes the interpretation of active-source seismic reflection data challenging, however, recent reprocessing allowed to resolve faults above and at the top of the basement. These faults generally do not coincide with the location of microseismic events and their continuation to the general depth of the seismic events cannot be assumed. This paper shows how the interpretation of the microseismicity can complement structural interpretations of active-source seismic reflection data. In particular, we analyze clusters and bursts (abrupt increases) of microseismicity, identify unresolved, smaller-scale weaknesses and extract statistical parameters. These parameters allow comparisons with the interpreted faults, and with fracture sets intercepted by boreholes. During injection at the Decatur site, the injection pressure was kept far below fracture pressure, nevertheless, seismic events were induced and spread far beyond the expected extent of the CO 2 plume. We argue that local stress transfers related to the CO 2 injection reactivated pre-existing fractures within the critically stressed basement. Finally, we conducted a slip tendency analysis for faults interpreted from active seismic, selected cluster, bursts and nodal planes from focal mechanisms to determine if the interpreted structures are optimally oriented with respect to the stress regime. Our results suggest that the orientation of fractures close to the injection well, generally shows slight deviations from the optimal orientation for slip. This might indicate either slight local deviations of the maximum horizontal stress azimuth from the average direction used in the analysis, or the lack of optimally oriented fractures at this location.

58 GEOSCIENCES↗

Design exploration of a Symmetric Pass Gate Adiabatic Logic for energy-efficient and secure hardware

Adiabatic logic is one of the circuit design techniques for designing energy-efficient hardware. In recent years, it has also been proved that this technique is suitable for designing secure hardware. In the existing literature, a Secured Quasi-Adiabatic Logic Family (SQAL) has recently been proposed in designing Differential Power Analysis (DPA)-resistant and energy-efficient hardware. SQAL shows improvement over all other existing DPA-resistant adiabatic logic in terms of energy dissipation and area-overhead. However, the drawback is, SQAL suffers from non-adiabatic energy loss during the evaluation of the outputs. To minimize the non-adiabatic loss, we propose in this paper a novel Symmetric Pass Gate Adiabatic Logic (SPGAL). SPICE simulations show that the bit-parallel cellular multiplier over GF(2 4 ) that we implemented using SPGAL saves up to 81% of energy as compared to SQAL at 12.5 MHz. Calculated values of Normalized Energy Deviation (NED) and Normalized Standard Deviation (NSD) show that the proposed logic gates based on SPGAL consume uniform energy for every cycle of operation irrespective of their input transition. Finally, the uniform energy rate and low power operation shows that the proposed SPGAL is energy-efficient in nature and would be resistant to DPA attack at the circuit level.

97 MATHEMATICS AND COMPUTING↗

Recyclability assessment of nano-reinforced plastic packaging

Highlights: • The study compares the recyclability of polymers with and without nanoparticles. • Visual appearance, material quality and mechanical properties are evaluated. • Minor variations in mechanical properties in R-PE and R-PP with nanoparticles. • Slight degradation of R-PET which affect mechanical properties. • Colour deviations in recycled PE, PP and PET in ranges higher that 0.3 units. - Abstract: Packaging is expected to become the leading application for nano-composites by 2020 due to the great advantages on mechanical and active properties achieved with these substances. As novel materials, and although there are some current applications in the market, there is still unknown areas under development. One key issue to be addressed is to know more about the implications of the nano-composite packaging materials once they become waste. The present study evaluates the extrusion process of four nanomaterials (Layered silicate modified nanoclay (Nanoclay1), Calcium Carbonate (CaCO{sub 3}), Silver (Ag) and Zinc Oxide (ZnO) as part of different virgin polymer matrices of polyethylene (PE), Polypropylene (PP) and Polyethyleneterephtalate (PET). Thus, the following film plastic materials: (PE–Nanoclay1, PE–CaCO{sub 3}, PP–Ag, PET–ZnO, PET–Ag, PET–Nanoclay1) have been processed considering different recycling scenarios. Results on recyclability show that for PE and PP, in general terms and except for some minor variations in yellowness index, tensile modulus, tensile strength and tear strength (PE with Nanoclay1, PP with Ag), the introduction of nanomaterial in the recycling streams for plastic films does not affect the final recycled plastic material in terms of mechanical properties and material quality compared to conventional recycled plastic. Regarding PET, results show that the increasing addition of nanomaterial into the recycled PET matrix (especially PET–Ag) could influence important properties of the recycled material, due to a slight degradation of the polymer, such as increasing pinholes, degradation fumes and elongation at break. Moreover, it should be noted that colour deviations were visible in most of the samples (PE, PP and PET) in levels higher than 0.3 units (limit perceivable by the human eye). The acceptance of these changes in the properties of recycled PE, PP and PET will depend on the specific applications considered (e.g. packaging applications are more strict in material quality that urban furniture or construction products)

36 MATERIALS SCIENCE↗

Drag of a heated sphere at low Reynolds numbers in the absence of buoyancy

Fully resolved simulations are used to quantify the effects of heat transfer in the absence of buoyancy on the drag of a spatially fixed heated spherical particle at low Reynolds numbers ( $Re$ ) in the range $10^{-3}\leqslant Re\leqslant 10$ in a variable-property fluid. The case where buoyancy is present is analysed in a subsequent paper. This analysis is carried out without making any assumptions on the amount of heat addition from the sphere and thus encompasses both the heating regime where the Boussinesq approximation holds and the regime where it breaks down. The particle is assumed to have a low Biot number, which means that the particle is uniformly at the same temperature and has no internal temperature gradients. Large deviations in the value of the drag coefficient as the temperature of the sphere increases are observed. When $Re , these deviations are explained using a low-Mach-number perturbation analysis as irrotational corrections to a Stokes–Oseen base flow. Correlations for the drag and Nusselt number of a heated sphere are proposed for the range of Reynolds numbers $10^{-3}\leqslant Re\leqslant 10$ which fit the computationally obtained values with less than 1 % and 3 % errors, respectively. These correlations can be used in simulations of gas–solid flows where the accuracy of the drag law affects the prediction of the overall flow behaviour. Finally, an analogy to incompressible flow over a modified sphere is demonstrated.

Mechanics↗

Elimination of Systematic Mass Measurement Errors in Liquid Chromatography-Mass Spectrometry Based Proteomics using Regression Models and a priori Partial Knowledge of the Sample Content

The high mass measurement accuracy and precision available with recently developed mass spectrometers is increasingly used in proteomics analyses to confidently identify tryptic peptides from complex mixtures of proteins, as well as post-translational modifications and peptides from non-annotated proteins. To take full advantage of high mass measurement accuracy instruments it is necessary to limit systematic mass measurement errors. It is well known that errors in the measurement of m/z can be affected by experimental parameters that include e.g., outdated calibration coefficients, ion intensity, and temperature changes during the measurement. Traditionally, these variations have been corrected through the use of internal calibrants (well-characterized standards introduced with the sample being analyzed). In this paper we describe an alternative approach where the calibration is provided through the use of a priori knowledge of the sample being analyzed. Such an approach has previously been demonstrated based on the dependence of systematic error on m/z alone. To incorporate additional explanatory variables, we employed multidimensional, nonparametric regression models, which were evaluated using several commercially available instruments. The applied approach is shown to remove any noticeable biases from the overall mass measurement errors, and decreases the overall standard deviation of the mass measurement error distribution by 1.2- to 2-fold, depending on instrument type. Subsequent reduction of the random errors based on multiple measurements over consecutive spectra further improves accuracy and results in an overall decrease of the standard deviation by 1.8- to 3.7-fold. This new procedure will decrease the false discovery rates for peptide identifications using high accuracy mass measurements.

Petyuk, Vladislav A.↗

Determination of elemental constituents in different matrix materials and flow injection studies by the electrolyte cathode glow discharge technique with a new design

An open-to-air type electrolyte cathode discharge (ELCAD) has been developed with a new design. The present configuration leads to a stable plasma even at low flow rates (0.96 mL/min). Plasma fluctuations arising from the variations in the gap between solid anode and liquid cathode were eliminated by providing a V-groove to the liquid glass-capillary. Cathode (ground) connection is given to the solution at the V-groove itself. Interfaced to atomic emission spectrometry (AES), its analytical performance is evaluated. The optimized molarity of the solution is 0.2 M. The analytical response curves for Ca, Cu, Cd, Pb, Hg, Fe, and Zn demonstrated good linearity. The limit of detections of Ca, Cu, Cd, Pb, Hg, Fe, and Zn are determined to be 17, 11, 5, 45, 15, 28, and 3 ng mL{sup -1}. At an integration time of 0.3 s, the relative standard deviation (RSD) values of the acid blank solutions are found to be less than 10% for the elements Ca, Cu, Cd, Hg, Fe, and Zn and 18% for Pb. The method is applied for the determination of the elemental constituents in different matrix materials such as tuna fish (IAEA-350), oyster tissue (NIST SRM 1566a), and coal fly ash (CFA SRM 1633b). The obtained results are in good agreement with the certified values. The accuracy is found to be between 7% and 0.6% for major to trace levels of constituent elements and the precision between 11% and 0.6%. For the injection of 100 {mu} L of 200 ng mL{sup -1} mercury solution at the flow rate of 0.8 mL/min, the flow injection studies resulted in the relative standard deviation (RSD) of 8%, concentration detection limit of 10 ng/mL, and mass detection limit of 1 ng for mercury.

01 COAL, LIGNITE, AND PEAT↗

Plutonium(IV) and (V) sorption to goethite at sub-femtomolar to micromolar concentrations: Redox transformations and surface precipitation

Here, Pu(IV) and Pu(V) sorption to goethite was investigated over a concentration range of 10 –15 –10 –5 M at pH 8. Experiments with initial Pu concentrations of 10 –15 – 10 –8 M produced linear Pu sorption isotherms, demonstrating that Pu sorption to goethite is not concentration-dependent across this concentration range. Equivalent Pu(IV) and Pu(V) sorption Kd values obtained at 1 and 2-week sampling time points indicated that Pu(V) is rapidly reduced to Pu(IV) on the goethite surface. Further, it suggested that Pu surface redox transformations are sufficiently rapid to achieve an equilibrium state within 1 week, regardless of the initial Pu oxidation state. At initial concentrations >10 –8 M, both Pu oxidation states exhibited deviations from linear sorption behavior and less Pu was adsorbed than at lower concentrations. NanoSIMS and HRTEM analysis of samples with initial Pu concentrations of 10 –8 – 10 –6 M indicated that Pu surface and/or bulk precipitation was likely responsible for this deviation. In 10 –6 M Pu(IV) and Pu(V) samples, HRTEM analysis showed the formation of a body centered cubic (bcc) Pu 4 O 7 structure on the goethite surface, confirming that reduction of Pu(V) had occurred on the mineral surface and that epitaxial distortion previously observed for Pu(IV) sorption occurs with Pu(V) as well.

54 ENVIRONMENTAL SCIENCES↗

Direct Effect of Solvent Viscosity on the Physical Mass Transfer for Wavy Film Flow in a Packed Column

ABSTRACT Post-combustion carbon capture via solvent absorption in a packed column can be a promising technology for mitigating greenhouse gas emissions. The mass transfer between gas and liquid solvent phases plays a critical role in determining the packing height of the packed column. Recent experiments [1] involving physical mass transfer for aqueous amine in a packed column have distinguished the direct and indirect impacts of viscosity (µ_L) on the mass transfer coefficient ?( k?_L). The direct impact of viscosity on the mass transfer coefficient has been found to be significantly higher for a packed column ?(k?_L~µ_L^(-0.38)) than a wetted wall column (WWC) ?(k?_L~µ_L^(-0.17)). To explain the deviation from the well-controlled uniform film flow in a WWC, we propose a mechanism involving the unavoidable wavy film flow and eddy-enhanced mass transfer in a packed column. A mathematical analysis based on fundamental flow and mass transfer equations is presented to quantify this deviation. The correlation for mass transfer coefficient derived from the mathematical analysis is found to match the corresponding one derived from the experiments for a packed column. Multiphase flow simulations using the Volume of Fluid method also are conducted to verify the direct impact of viscosity on the mass transfer coefficient for both uniform and wavy film flows. The mass transfer coefficient calculated from simulations shows steeper variation with viscosity for wavy film compared to the uniform film, further confirming our proposed theory. A similar relation ?(k?_L~µ^(-0.38)) for wavy film flow in a packed column is observed for aqueous solvent from both theory, experiment, and computer simulations.

Mass transfer, viscosity, eddy diffusion↗

Atom Equivalent Energies for the Rapid Estimation of the Heat of Formation of Explosive Molecules from Density Functional Tight Binding Theory

Atom equivalent energies have been derived from which the gas-phase heat of formation of explosive molecules can be estimated from fast, semiempirical density functional tight binding total energy calculations. The root-mean-square deviation and maximum deviation of the heats of formation from the experimental values for the set of 45 energetic molecules compiled by Byrd and Rice [ J. Phys. Chem. A, 2006, 110, 1005–1013] are 10.4 and 25.5 kcal/mol, respectively, using 4 atom equivalent energies and 7.4 and 15.0 kcal/mol, respectively, using 7 atom equivalent energies. These errors are around a factor of 2–3 larger than those obtained from density functional theory calculations but are smaller than those obtained from other semiempirical electronic structure methods. Heats of formation calculated with density functional tight binding theory using the 4 and 7 atom equivalent energies, the Byrd and Rice scheme, and the atom pair contribution method for a new set of 531 energetic molecules that contain only carbon, hydrogen, nitrogen, and oxygen are provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Examination of How Well Long-Range-Corrected Density Functionals Satisfy the Ionization Energy Theorem

For this work, we calculated the vertical ionization energies (VIE) of 99 species in two ways to examine the accuracy of several long-range-corrected (LC) hybrid meta functionals in comparison with a gradient approximation (GA), global hybrids, and doubly hybrids. In the category of LC functionals, we examined both those with meta ingredients (i.e., that depend on the kinetic energy density) and those without them. The LC-hybrid meta functionals examined are M11, revM11, M11plus, and ωB97M-V. The reference data used to assess accuracy consist of 95 molecules and 4 atoms in the GW100 set. The two methods studied are the ΔSCF method (involving the difference of neutral and cation self-consistent field (SCF) energies) and the ionization energy theorem (involving the orbital energy of the highest occupied molecular orbital, HOMO). We calculated linear correlation coefficients (r 2 ) and mean absolute deviations (MADs) between each approach and the reference VIE value from the CCSD(T)/def2-TZVPP level of theory. We compared the new LC-hybrid meta calculations to calculations with the 10 functionals in a previous VIE study by Brémond et al. and to the calculations with LC-BLYP (LC-Becke, Lee–Yang–Parr), CAM-B3LYP (Coulomb-attenuating-method Becke-3-parameter Lee–Yang–Parr), LC-ωHPBE, and ωB97X-D. The results show that Minnesota LC-hybrid meta functionals have the smallest mean absolute deviation of ionization energy theorem VIEs with the reference data; the LC-ωHPBE functional also does quite well in this test. This is very encouraging and indicates that LC-hybrid meta functionals would be the best starting points for the tuning strategy that has been shown to be a very good procedure for improving time-dependent density functional calculations, and it also helps explain the good success of LC-hybrid meta functionals for molecular excitation energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dipole Moment Calculations Using Multiconfiguration Pair-Density Functional Theory and Hybrid Multiconfiguration Pair-Density Functional Theory

The dipole moment is the molecular property that most directly indicates molecular polarity. The accuracy of computed dipole moments depends strongly on the quality of the calculated electron density, and the breakdown of single-reference methods for strongly correlated systems can lead to poor predictions of the dipole moments in those cases. Here, we derive the analytical expression for obtaining the electric dipole moment by multiconfiguration pair density functional theory (MCPDFT), and we assess the accuracy of MC-PDFT for predicting dipole moments at equilibrium and nonequilibrium geometries. We show that MC-PDFT dipole moment curves have reasonable behavior even for stretched geometries, and they significantly improve upon the CASSCF results by capturing more electron correlation. Herein, the analysis of a dataset consisting of 18 first-row transition metal diatomics and 6 main-group polyatomic molecules with multireference character suggests that MC-PDFT and its hybrid extension (HMC-PDFT) perform comparably to CASPT2 and MRCISD+Q methods and have a mean unsigned deviation of 0.2–0.3 D with respect to the best available dipole moment reference values. We explored the dependence of the predicted dipole moments upon the choice of the on-top density functional and active space, and we recommend the tPBE and hybrid tPBE0 on-top choices for the functionals combined with the moderate correlated participating orbital scheme for selecting the active space. With these choices, the mean unsigned deviations (in debyes) of the calculated equilibrium dipole moments from the best estimates are 0.77 for CASSCF, 0.29 for MC-PDFT, 0.24 for HMCPDFT, 0.28 for CASPT2, and 0.25 for MRCISD+Q. These results are encouraging because the computational cost of MC-PDFT or HMC-PDFT is largely reduced compared to the CASPT2 and MRCISD+Q methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate Machine Learning for Predicting the Viscosities of Deep Eutectic Solvents

Deep eutectic solvents (DESs) are emerging as environmentally friendly designer solvents for mass transport and heat transfer processes in industrial applications; however, the lack of accurate tools to predict and thus control their viscosities under both a range of environmental factors and formulations hinders their general application. While DESs may serve as designer solvents, with nearly unlimited combinations, this unfortunately makes it experimentally infeasible to comprehensively measure the viscosities of all DESs of potential industrial interest. To assist in the design of DESs, we have developed several new machine learning (ML) models that accurately and rapidly predict the viscosities of a diverse group of DESs at different temperatures and molar ratios using, to date, one of the most comprehensive data sets containing the properties of over 670 DESs over a wide range of temperatures (278.15–385.25 K). Three ML models, including support vector regression (SVR), feed forward neural networks (FFNNs), and categorical boosting (CatBoost), were developed to predict DES viscosity as a function of temperature and molar ratio and contrasted with multilinear and two-factor polynomial regression baselines. Further, quantum chemistry-based, COSMO-RS-derived sigma profile (σ-profile) features were used as inputs for the ML models. The CatBoost model is excellent at externally predicting DES viscosity, as indicated by high R 2 (0.99) and low root-mean-square-error (RMSE) and average absolute relative deviations (AARD) (5.22%) values for the testing data sets, and 98% of the data points lie within the 15% of AARD deviations. Furthermore, SHapley additive explanation (SHAP) analysis was employed to interpret the ML results and rationalize the viscosity predictions. The result is an ML approach that accurately predicts viscosity and will aid in accelerating the design of appropriate DESs for industrial applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying High Ionic Conductivity Compositions of Ionic Liquid Electrolytes Using Features of the Solvation Environment

Binary mixtures of ionic liquids with molecular solvents are gaining interest in electrochemical applications due to the improvement in their performance over neat ionic liquids. Dilution with suitable molecular solvents can reduce the viscosity and facilitate faster diffusion of ions, thereby yielding substantially higher ionic conductivity than that for a pure ionic liquid. Although viscosity and diffusion coefficients typically behave as monotonic functions of concentration, ionic conductivity often passes through a peak value at an optimum molar ratio of the molecular solvent to the ionic liquid. The ionic conductivity maximum is generally explained in terms of a balance between the ease of charge transport and the concentration of the charge carriers. In this work, fluctuation in the local environment surrounding an ion is invoked as a plausible explanation for the ionic conductivity mechanism with a binary mixture of 1-ethyl-3-methylimidazolium tetrafluoroborate and ethylene glycol as an example. The magnitude of the dynamism in the local environment is captured by measuring the spatial and temporal features of the solvation environment. Standard deviation in the number of ions in the solvation environment serves as a spatial feature, while the cage correlation lifetimes for oppositely charged ions within the first solvation shell serve as a temporal feature. Large standard deviations in the cluster ion population and short cage correlation lifetimes are indicators of highly dynamic ionic environment at the molecular level and consequently yield high ionic conductivity. Such compositions were found to be in good agreement with the optimum ionic liquid mole fractions obtained through experimental measurement. Short cage correlation lifetimes enable the identification of optimum mixture compositions using simulation trajectories significantly shorter than those required to implement the Nernst–Einstein or Einstein formalisms for calculating ionic conductivity. We validated the applicability of this approach across force fields and in six ionic liquid-molecular solvent electrolytes formed with combination of cations, anions, and solvents. We offer a computationally efficient approach of screening ionic liquid-molecular solvent binary mixture electrolytes to identify molar ratios that yield high ionic conductivity.

25 ENERGY STORAGE↗

Bond Dissociation Energies for Diatomic Molecules Containing 3d Transition Metals: Benchmark Scalar-Relativistic Coupled-Cluster Calculations for 20 Molecules

Benchmark scalar-relativistic coupled-cluster calculations for dissociation energies of the 20 diatomic molecules containing 3d transition metals in the 3dMLBE20 database ( J. Chem. Theory Comput. 2015, 11, 2036) are reported in this paper. Electron correlation and basis set effects are systematically studied. The agreement between theory and experiment is in general satisfactory. For a subset of 16 molecules, the standard deviation between computational and experimental values is 9 kJ/mol with the maximum deviation being 15 kJ/mol. The discrepancies between theory and experiment remain substantial (more than 20 kJ/mol) for VH, CrH, CoH, and FeH. To explore the source of the latter discrepancies, the analysis used to determine the experimental dissociation energies for VH and CrH is revisited. It is shown that, if improved values are used for the heterolytic C–H dissociation energies of di- and trimethylamine involved in the experimental determination, the experimental values for the dissociation energies of VH and CrH are increased by 18 kJ/mol, such that D 0 (VH) = 223 ± 7 kJ/mol and D 0 (CrH) = 204 ± 7 kJ/mol (or D e (VH) = 233 ± 7 kJ/mol and D e (CrH) = 214 ± 7 kJ/mol). Finally, the new experimental values agree quite well with the calculated values, showing the consistency of the computation and the measured reaction thresholds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Activation by Silica Supported Metal Ion Catalysts: Catalytic Properties of Metals and Performance of DFT Functionals

Single-site heterogeneous catalysts (SSHC) have received increasing attention due to their well-defined active sites and potentially high specific activity. Detailed computational studies were carried out on a set of potential SSHC’s, i.e., silica-supported metal ions, to investigate the reactivity of these catalysts with H2 as well as to evaluate the performance of density functional theory (DFT) methods in conjunction with triple-ζ quality basis sets (i.e., cc-pVTZ) on reaction energetics. The ions considered include 4d and 5d metals as well as several post-transition metal ions. A representative cluster model of silica is used to calculate reaction free energies of the metal hydride formation that results from the heterolytic cleavage of H2 on the M–O bond. The hydride formation free energy is previously shown to be strongly correlated with the catalytic activity of such catalysts for alkene hydrogenation. ONIOM calculations (CCSD(T)//MP2) are used to assess the accuracy and reliability of the MP2 results and it is found that MP2 is a suitable level of theory for gauging the performance of DFT functionals. The performance of various DFT functionals is assessed relative to MP2 results and it is found that the wB97xd and PBE0 functionals have the lowest standard deviation (STD) value while the MN12SX and PBE functionals have the lowest mean absolute deviation (MAD) values. The B3LYP functional is shown to have similar MAD and STD values as the top performing functionals. Potential active SSHC’s for exergonic hydrogen activation predicted in this study include mostly late and post transition metal ions, i.e., Au3+, Pd2+, Pt4+, Pd4+, Ir4+, Hg2+, Rh3+, Pb4+, Tl3+, In3+, Ir3+, Os4+, Cd2+, Ru2+, and Ga3+. This study provides important guidance to future computational studies of such catalyst systems.

Plascencia, Cesar↗