Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Two-axis winch installer for heavy ducts in confined space

Two-axis winching and traversing device is used for installing liquid-propellant rocket-engine fuel and liquid oxygen suction ducts between the valves and the rocket engine on a test stand. The device raises and maneuvers the duct into the required position where it can be safely installed by mechanics.

Cox, E. F.↗

Monitor for status epilepticus seizures

This paper describes the sensor technology and associated electronics of a monitor designed to detect the onset of a seizure disorder called status epilepticus. It is a condition that affects approximately 3-5 percent of those individuals suffering from epilepsy. This form of epilepsy does not follow the typical cycle of start-peak-end. The convulsions continue until medically interrupted and are life threatening. The mortality rate is high without prompt medical treatment at a suitable facility. The paper describes the details of a monitor design that provides an inexpensive solution to the needs of those responsible for the care of individuals afflicted with this disorder. The monitor has been designed as a cooperative research and development effort involving the United States Army Armament Research, Development, and Engineering Center's Benet Laboratories (Benet) and the Cerebral Palsy Center for the Disabled (Center), in association with the Department of Neurology at Albany Medical College (AMC). Benet has delivered a working prototype of the device for field testing, in collaboration with Albany Medical College. The Center has identified several children in need of special monitoring and has agreed to pursue commercialization of the device.

Johnson, Mark↗

Statistical Evaluation of Molecular Contamination During Spacecraft Thermal Vacuum Test

The purpose of this paper is to evaluate the statistical molecular contamination data with a goal to improve spacecraft contamination control. The statistical data was generated in typical thermal vacuum tests at the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The magnitude of material outgassing was measured using a Quartz Crystal Microbalance (QCM) device during the test. A solvent rinse sample was taken at the conclusion of the each test. Then detailed qualitative and quantitative measurements were obtained through chemical analyses. All data used in this study encompassed numerous spacecraft tests in recent years.

Chen, Philip↗

Statistical Evaluation of Molecular Contamination During Spacecraft Thermal Vacuum Test

The purpose of this paper is to evaluate the statistical molecular contamination data with a goal to improve spacecraft contamination control. The statistical data was generated in typical thermal vacuum tests at the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The magnitude of material outgassing was measured using a Quartz Crystal Microbalance (QCM) device during the test. A solvent rinse sample was taken at the conclusion of each test. Then detailed qualitative and quantitative measurements were obtained through chemical analyses. All data used in this study encompassed numerous spacecraft tests in recent years.

Chen, Philip↗

Statistical Evaluation of Molecular Contamination During Spacecraft Thermal Vacuum Test

The purpose of this paper is to evaluate the statistical molecular contamination data with a goal to improve spacecraft contamination control. The statistical data was generated in typical thermal vacuum tests at the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The magnitude of material outgassing was measured using a Quartz Crystal Microbalance (QCNO device during the test. A solvent rinse sample was taken at the conclusion of each test. Then detailed qualitative and quantitative measurements were obtained through chemical analyses. All data used in this study encompassed numerous spacecraft tests in recent years.

Chen, Philip↗

Towards linking lab and field lifetimes of perovskite solar cells

Metal halide perovskite solar cells (PSCs) represent a promising low-cost, thin-film photovoltaic (PV) technology, with unprecedented power conversion efficiencies (PCEs) obtained for both single-junction and tandem applications. To push PSCs toward commercialization, it is critical, albeit challenging, to understand device reliability under real-world outdoor conditions where multiple stress factors (e.g., light, heat, humidity) coexist, generating complicated degradation behaviors. It is necessary to identify accelerated indoor testing protocols - which can correlate specific stressors with observed degradation modes in fielded devices - to quickly guide PSC development. Here, we use a state-of-the-art p-i-n PSC stack (with PCE up to ~25.5%) to show that indoor accelerated stability tests can predict our 6-month outdoor aging tests. Device degradation rates under illumination and at elevated temperatures are most instructive for understanding outdoor device reliability. Further, we also find that the indium tin oxide (ITO)/self-assembled monolayer (SAM)-based hole transport layer (HTL)/perovskite interface most strongly affects our device operation stability. Improving the ion-blocking properties of the SAM HTL increases averaged device operational stability at 50 degree C-85 °C by a factor of ~2.8, reaching over 1000 h at 85 °C and to near 8200 h at 50 °C with a projected 20% degradation, which is among the best to date for high-efficiency p-i-n PSCs.

14 SOLAR ENERGY↗

Final Report: Next Generation Diamond Drumhead X-Ray Optics

Problem / Opportunity Statement: Future high-impact scientific applications at synchrotron and Free-Electron Laser (FEL) X-ray sources require the development of processing and mounting methods for ultra-thin diamond crystals to meet the most challenging needs of pioneering research at next generation light source facilities. These methods should be capable of manufacturing crystal plates as thin as 10 micrometers over an area of a few mm2, and with a surface cut in different crystal orientations, such as the diamond {100}, {111}, {110} and {113} planes. Project Purpose and Approach: In Phase I, Great Lakes Crystal Technologies (GLCT) partnered with Stonybrook University (SUNY) to created thin diamond drumhead crystals. The purpose of the Phase I project is to transfer the drumhead membrane window etching technology from SUNY to GLCT. Testing of a device using the beamline at Stanford Linear Accelerator Laboratory was initially planned, however, a delay on the part of a third party service provided required us to get beamline testing done at Argonne National Laboratory. Phase I Taskwork: Testing of a high purity diamond plate thinning and etching process was performed. By SUNY and GLCT. Plates were sent to a third party service provider for thinning to ~100 microns, however, delays required that GLCT develop an in-house thinning process to complete the taskwork. GLCT successfully developed this in-house capability even though it was initially planned to be part of the Phase II Taskwork. Multiple practice and deliverable plates were provided to SUNY to be etched into the target drumhead devices. GLCT practiced and refined an in-house plate thinning process and produced five plates with thicknesses in the 60 – 150 micron range. Processing of the plates has begun and will continue in a no-cost extension period necessitated by the third party service provider delay. GLCT also procured and installed a reactive ion etching/inductively coupled plasma system. In addition, one of the thinned plates was measured at the Applied Photon Source at APL for a pre-processing assessment of the crystalline strain. After processing the plate into a drumhead and annealing, a post-processing assessment of the strain will be performed. Phase I Results: The initial data from GLCT’s plate thinning process development, SUNY’s drumhead etching processing, and characterization at APS/ANL demonstrate our teams capabilities to achieve the project goals. Commercial Applications & Benefits: The proposed technology will benefit advanced x-ray science performed at BNL and the 70+ additional advanced beamlines around the world. There are also a number of medical and homeland security applications which could benefit from the technology.

Quayle, Paul↗

Atomic-Scale Manipulation and In Situ Characterization with Scanning Tunneling Microscopy

Scanning tunneling microscope (STM) has presented a revolutionary methodology to nanoscience and nanotechnology. It enables imaging of the topography of surfaces, mapping the distribution of electronic density of states, and manipulating individual atoms and molecules, all at atomic resolutions. In particular, atom manipulation capability has evolved from fabricating individual nanostructures toward the scalable production of the atomic-sized devices bottom-up. The combination of precision synthesis and in situ characterization has enabled direct visualization of many quantum phenomena and fast proof-of-principle testing of quantum device functions with immediate feedback to guide improved synthesis. Several representative examples are reviewed to demonstrate the recent development of atomic-scale manipulation, focusing on progress that addresses quantum properties by design in several technologically relevant materials systems. Integration of several atomically precisely controlled probes in a multiprobe STM system vastly extends the capability of in situ characterization to a new dimension where the charge and spin transport behaviors can be examined from mesoscopic to atomic length scale. The automation of atomic-scale manipulation and the integration with well-established lithographic processes further push this bottom-up approach to a new level that combines reproducible fabrication, extraordinary programmability, and the ability to produce large-scale arrays of quantum structures.

47 OTHER INSTRUMENTATION↗

Research and Development to Reduce Impurity Production and Transport of the Impurities to the Target in Linear Plasma Devices Using Helicon Plasma Sources

Linear plasma devices used to test plasma facing materials (PFMs) and components for fusion reactors are often suffering under the production of intrinsic impurities from the plasma source system. Most linear plasma devices use internal electrodes (hollow cathodes, reflex arc, or cascading arc), which typically are the source of the main impurities. The next-generation plasma generators use radio frequency (RF) plasma sources like helicons to avoid internal electrodes. However, high power operation of helicons has proven to result in impurity production due to the high rectified sheath voltages created. Depending on the plasma parameters and magnetic configuration, these impurities can be transported to the target and deposited there to unacceptable high levels. Here, in this contribution, the experimental results from Proto-MPEX are summarized, and the conclusions of the impurity source physics are given. Methods to reduce the impurity production, the impurity transport, and the net deposition on the target are presented. These methods to reduce the impurity production include Faraday screens to reduce the sheath voltage drop, high-Z refractory coatings to reduce the erosion yield, and wall conditioning methods. Methods to reduce the impurity transport include changes in the magnetic configuration as well as electron heating to change axial and radial temperature profiles. Preliminary results on the effectiveness of some of these methods are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monitoring of explosive/pyrotechnic performance.

Utilization of performance monitoring techniques for acceptance, lot qualification, and comparison testing, as well as to provide engineering guidelines for systems design. Test techniques and apparatus have been developed to evaluate the performance of squibs, initiators, gas generating cartridges, detonators, and linear explosives for aerospace applications. A variety of devices has been tested in each of these apparatuses, including the Apollo Standard Initiator, the Apollo End Detonating Cartridge, and the mild detonating fuse and flexible linear shaped charge.

Bement, L. J.↗

Magnetic Calorimeter Option for the Lynx X-Ray Microcalorimeter

One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagnetic sensor to detect the temperature rise in a microfabricated x-ray absorber. While small arrays of MMCs have previously been demonstrated that have energy resolution better than the 3 eV requirement for LXM, we describe LXM prototype MMC arrays that have 55,800 x-ray pixels, thermally linked to 5688 sensors in “hydra” configurations, and that have sensor inductance increased to avoid signal loss from the stray inductance in the large-scale arrays when the detectors are read out with microwave superconducting quantum interference device multiplexers, and that use multilevel planarized superconducting wiring to provide low-inductance, low-crosstalk connections to each pixel. We describe the features of recently tested MMC prototype devices and simulations of expected performance in designs opti- mized for the three subarray types in LXM.

Stevenson, Thomas R.↗

Single Drop Cytometry Onboard the International Space Station

Real-time lab analysis is needed to support clinical decision making and research on human missions to the Moon and Mars. Powerful laboratory instruments, such as flow cytometers, are generally too cumbersome for spaceflight. Here, we show that scant test samples can be measured in microgravity, by a trained astronaut, using a miniature cytometry-based analyzer, the rHEALTH ONE, modified specifically for spaceflight. The base device addresses critical spaceflight requirements including minimal resource utilization and alignment-free optics for surviving rocket launch. To fully enable reduced gravity operation onboard the space station, we incorporated bubble-free fluidics, electromagnetic shielding, and gravity-independent sample introduction. We show microvolume flow cytometry from 10 μL sample drops, with data from five simultaneous channels using 10 μs bin intervals during each sample run, yielding an average of 72 million raw data points in approximately 2 minutes. We demonstrate the device measures each test sample repeatably, including correct identification of a sample that degraded in transit to the International Space Station. This approach can be utilized to further our understanding of spaceflight biology and provide immediate, actionable diagnostic information for management of astronaut health without the need for Earth-dependent analysis.

Daniel J. Rea↗

A Possible Dechirper Device for the LCLS and LCLS-II

The purpose of this note is to investigate the use of a metallic pipe with small corrugations for passively dechirping, through its wakefield, the LCLS beam. Similar dechirper systems have been tested in Pohang and Brookhaven at relatively low energies (< 100 MeV) and with relatively long bunches (> 1 ps). A recent proposal from RadiaBeam is to build a 2-m dechirper and install it in the LCLS for a GeV, femtosecond beam test. Such a device can be used to either reduce or increase the amount of energy chirp in a short electron bunch prior to the FEL interaction in the undulator, and hence provide a flexible control of the LCLS FEL bandwidth. The results can be used to guide the design of the LCLS-II dechirper, where it is important to remove unwanted electron energy chirp from the LCLS-II superconducting accelerator and to provide independent controls of x-ray properties in each of the two parallel beamlines.

43 PARTICLE ACCELERATORS↗

Current Status of High Performance Large Format Si:As IBC Detectors for SOFIA-like Applications

Airborne and space telescope astronomical observations in the 5-25 micrometer wavelength region, are critical for understanding the physical conditions, composition, chemistry, and excitation of many environments in the interstellar medium, external galaxies, solar system objects, extra-solar systems, and stars. The scientific impact is particularly unique in the 5-8 micrometer and 14-25 micrometer regions which are inaccessible or poorly observed from ground-based observatories. Large-format area mid-infrared (MIR) detectors sensitive over these wavelengths and operable under moderate backgrounds (greater than 10(circumflex)6 e-/s at R=2000, 10(micrometers)) are essential for efficient large-area survey imaging and for taking moderate resolution spectra over a large spectral range. Both SOFIA and passively cooled Explorer observatories could benefit from this technology. Current first-light SOFIA instruments use small-format MIR FPA's of sizes 128x128 and 256x256, With the collaboration of Raytheon Infrared Operations (RIO), NASA-ARC has been testing the first device of this kind, a combination of 1) the ALADDIN III readout multiplexer, cryo-processed for 6K operation, with 2) SIRTF IRAC-like Sides IBC detector material. designed for higher QE and low dark current. Here we report requirements. design, and initial fabrication and testing of the first 1024x1024 Si:As IBC mid-IR detector array for these conditions. This device has exhibited low dark current, moderate noise levels, and greater than 200,000 electron linear well size at 6K operation. We conclude with suggestions for future device development for optimal performance under moderate background, SOFIA- and low Earth orbit observing conditions.

Ennico, Kimberly↗

Real-time Canister Welding Health Monitoring and Prediction System for Spent Fuel Dry Storage

In this report, the salt mist corrosion testing at controlled temperature was carried out successfully on 304L SS submerged arc welded coupons by Unifog Dispersion Tower at ORNL. Corrosion in-situ monitoring system from Intelligent Automation, Inc. (IAI) was setup in the corrosion test and running smoothly to record signals during the corrosion test. Parts and device selection, sensors attachment, and experimental procedures are discussed. There wasn’t any visible corrosion or crack propagation on the weld coupon after about a month of corrosion testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structural manipulation of microcone arrays for microsurgical modification of ophthalmic tissues

The purpose of this study was to control the size and shape of fabricated glass microcone arrays for use in optical surgery instruments by varying the fiber drawing and etching methods. The spacing of the cones is controlled via the drawing process while the etching process controls the cone height-to-base ratio. The device viability was tested by imprinting, and subsequent staining, of low-density polyethylene and porcine corneas, resulting in a consistent patterned structure of micron-sized perforations. After imprint, the device was examined and no evidence of microcone fracture or over-penetration was present during the course of these experiments. This research promises to lead to advances in optical surgery for the treatment of recurrent corneal erosions, providing quicker, safer, and more cost-effective procedures with decreased risk of vision loss and scarring associated with current procedures such as anterior stromal puncture. The ease of procedure and micron sized incisions could potentially replace current techniques and provide a viable treatment alternative for recurrent corneal erosions in the visual axis.

Schaeffer, Daniel A↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Single-Event Latchup Testing of the Micrel MIC4424 Dual Power MOSFET Driver

We conducted 47 exposures of four different MIC4424 devices and did not observe any SEL or high-current events. This included worst-case conditions with a LET of 81 MeV-sq cm/mg, applied voltage of 18.5 V, a case temperature greater than 120 C, and a final fluence of 1x10(exp 7)/sq cm. We also monitored both the outputs for the presence of SETs. While the period of the 1 MHz square wave was slightly altered in some cases, no pulses were added or deleted. 1. Purpose: The purpose of this testing is to characterize the BiCMOS/DMOS Micrel MIC4424 dual, non-inverting MOSFET driver for single-event latchup (SEL) susceptibility. These data will be used for flight lot evaluation purposes. 2. Devices Tested: The MIC4423/4424/4425 family are highly reliable BiCMOS/DMOS buffer/driver MOSFET drivers. They are higher output current versions of the MIC4426/4427/4428. They can survive up to 5V of noise spiking, of either polarity, on the ground pin. They can accept, without either damage or logic upset, up to half an amp of reverse current (either polarity) forced back into their outputs. Primarily intended for driving power MOSFETs, the MIC4423/4424/4425 drivers are suitable for driving other loads (capacitive, resistive, or inductive) which require low-impedance, high peak currents, and fast switching times. Heavily loaded clock lines, coaxial cables, or piezoelectric transducers are some examples. The only known limitation on loading is that total power dissipated in the driver must be kept within the maximum power dissipation limits of the package. Five (5) parts were provided for SEL testing. We prepared four parts for irradiation and reserved one piece as an un-irradiated control. More information about the devices can be found in Table 1. The parts were prepared for testing by removing the lid from the CDIP package to expose the target die. The parts were then soldered to small copper circuit adapter boards for easy handling. These parts are fabricated in a bulk BiCMOS/DMOS technology. Since we do not know the number of overlayers used in the fabrication processes, linear energy transfer calculations are determined based on the top-surface incident ion species and kinetic energy.

Power MOSFET↗