Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

An Improved UAV-Based Fog Collector for Local-Scale Aerobiological Sampling

The use of unmanned air vehicles (UAVs) to passively collect fog for microbiological analysis is being investigated at NASA Ames, contributing to our understanding of the dynamics and limits of the biosphere. Current improvements to a preliminary payload design include physically modifying the mesh of the passive impactor collection unit (PICU) to increase fog-capture efficiency and a quick- mounting system to improve sample turnaround and contamination control. Increasing the water-capture efficiency of the PICU involved changing the surface roughness of the polypropylene mesh by abrasive sanding. Four scale models of the PICU were created, with three of those models sanded with 80-, 150-, and 240-grit sand paper for a minimum of thirty seconds on each side. Each mesh was individually tested in a fog-simulation chamber to measure collection efficiency. Tests showed that sanding the mesh will increase the water-capture efficiency by at least 3-fold for the 150- and 240-grit. Next steps are to determine the scaling laws and minimum amount of exposure time as a function of the fog density, to acquire enough microorganisms for analysis; a light-weight ground module for the PICU has been developed to allow rapid, easy field testing. Developing a mounting system that will ensure sterile deployment, as well as prompt changes of PICUs, for collection of fog water, utilized computational fluid dynamics (CFD) for the UAV to ensure that the location of the impactors will not be contaminated by particulates in the UAV downwash. The original design allowed the impactors to remain within sterile packaging until mounted on the UAV but did not address the concerns of contamination from aerodynamic ground effects and particulate lofting during takeoff. Design for a raised launch pad would allow for the sterile PICU to be attached to UAV and launched from outside the region of projected particulate lofting. California coastal sites have been scouted for appropriate testing locations. The improvements to the PICU design and operations will allow for multiple sampling points within a single fog event. The returned fog samples will undergo ion chromatography, qPCR, ATP quantification, and other tests to characterize microbial species and relevant biochemistry.

Wong, Amber↗

Regolith and Environment Science and Oxygen and Lunar Volatile Extraction (RESOLVE): Lunar Advanced Volatile Analysis (LAVA) Capillary Fluid Dynamic Restriction Effects on Gas Chromatography

The Resource Prospector (RP) mission with the Regolith and Environment Science and Oxygen Lunar Volatile Extraction (RESOLVE) payload aims to show the presence of water in lunar regolith, and establish a proving ground for NASAs mission to Mars. One of the analysis is performed by the Lunar Advanced Volatiles Analysis (LAVA) subsystem, which consists of a fluid network that facilitates the transport of volatile samples to a gas chromatograph and mass spectrometer (GC-MS) instrument. The understanding of fluid dynamics directed from the GC to the MS is important due to the influence of flow rates and pressures that affect the accuracy of and prevent the damage to the overall GC-MS instrument. The micro-scale capillary fluid network within the GC alone has various lengths and inner-diameters; therefore, determination of pressure differentials and flow rates are difficult to model computationally, with additional complexity from the vacuum conditions in space and lack of a lunar atmosphere. A series of tests were performed on an experimental set-up of the system where the inner diameters of the GC transfer line connecting to the MS were varied. The effect on chromatography readings were also studied by applying these lines onto a GC instrument. It was found that a smaller inner diameter transfer line resulted in a lower flow rate, as well as a lower pressure differential across the thermal conductivity detector (TCD) unit of the GC and a negligible pressure drop across the mock-up capillary column. The chromatography was affected with longer retention times and broader peak integrations. It was concluded that a 0.050 mm inner diameter line still proved most suitable for the systems flow rate preferences. In addition, it was evident that this small transfer line portrayed some expense to GC signal characteristics and the wait time for steady-state operation.

RESOLVE↗

Mechanical and optical response of polymethylpentene under dynamic compression

Polymethylpentene, commonly referred to by its trade name TPX (Mitsui Chemicals, Inc.), is a thermoplastic polymer that has the potential to be a useful window material for dynamic compression experiments. For such experiments, an optically transparent or a low x-ray absorptive window is often used to maintain stress within the sample during compression. TPX can be used as a low-impedance optical and x-ray window due to its good transmittance in most parts of the electromagnetic spectrum, very low density (0.83 g/cm 3 ), and low x-ray absorption. In dynamic compression experiments, interferometry can be used to determine the particle velocity at the interface between the sample and window. However, velocimetry measures the rate of change of the optical path length, commonly referred to as the apparent particle velocity. An experimentally determined window correction factor is needed to ascertain the actual particle velocity from the measured apparent velocity. Here, we present the results of a series of dynamic compression experiments from 1 to 31 GPa designed to characterize the mechanical and optical response of TPX, determine the range of stresses over which TPX is transparent, and determine the window correction factor. Finally, the index of refraction was found to be essentially linear in density, resulting in a simple constant correction factor. TPX was found to remain largely transparent over the entire stress range examined.

36 MATERIALS SCIENCE↗

Data-driven modeling and control of an X-ray bimorph adaptive mirror

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The emergence and transmission dynamics of HIV-1 CRF07_BC in Mainland China

A total of 1155 partial pol gene sequences of human immunodeficiency virus (HIV)-1 CRF07_BC were sampled between 1997 and 2015, spanning 13 provinces in Mainland China and risk groups [heterosexual, injecting drug users (IDU), and men who have sex with men (MSM)] to investigate the evolution, adaptation, spatiotemporal and risk group dynamics, migration patterns, and protein structure of HIV-1 CRF07_BC. Due to the unequal distribution of sequences across time, location, and risk group in the complete dataset (‘full1155’), subsampling methods were used. Maximum-likelihood and Bayesian phylogenetic analysis as well as discrete trait analysis of geographical location and risk group were carried out. To study mutations of a cluster of HIV-1 CRF07_BC (CRF07-1), we performed a comparative analysis of this cluster to the other CRF07_BC sequences (‘backbone_295’) and mapped the mutations observed in the respective protein structure. Our findings showed that HIV-1 CRF07_BC most likely originated among IDU in Yunnan Province between October 1992 to July 1993 [95 per cent hightest posterior density (HPD): May 1989–August 1995] and that IDU in Yunnan Province and MSM in Guangdong Province likely served as the viral sources during the early and more recent spread in Mainland China. We also revealed that HIV-1 CRF07-1 has been spreading for roughly 20 years and continues to cause local transmission in Mainland China and worldwide. Overall, our study sheds light on the dynamics of HIV-1 CRF07_BC distribution patterns in Mainland China. Our research may also be useful in formulating public health policies aimed at controlling acquired immune deficiency syndrome in Mainland China and globally.

60 APPLIED LIFE SCIENCES↗

The evolution of metallicity and metallicity gradients from z = 2.7 to 0.6 with KMOS{sup 3D}

We present measurements of the [N ii]/Hα ratio as a probe of gas-phase oxygen abundance for a sample of 419 star-forming galaxies at z = 0.6–2.7 from the KMOS{sup 3D} near-IR multi-integral field unit (IFU) survey. The mass–metallicity relation (MZR) is determined consistently with the same sample selection, metallicity tracer, and methodology over the wide redshift range probed by the survey. We find good agreement with long-slit surveys in the literature, except for the low-mass slope of the relation at z∼2.3, where this sample is less biased than previous samples based on optical spectroscopic redshifts. In this regime we measure a steeper slope than some literature results. Excluding the contribution from active galactic nuclei from the MZR reduces sensitivity at the high-mass end, but produces otherwise consistent results. There is no significant dependence of the [N ii]/Hα ratio on star formation rate at fixed redshift and stellar mass. The IFU data allow spatially resolved measurements of [N ii]/Hα, from which we can infer abundance gradients for 180 galaxies, thus tripling the current sample in the literature. The observed gradients are on average flat, with only 15 gradients statistically offset from zero at >3σ. We have modeled the effect of beam smearing, assuming a smooth intrinsic radial gradient and known seeing, inclination, and effective radius for each galaxy. Our seeing-limited observations can recover up to 70% of the intrinsic gradient for the largest, face-on disks, but only 30% for the smaller, more inclined galaxies. We do not find significant trends between observed or corrected gradients and any stellar population, dynamical, or structural galaxy parameters, mostly in agreement with existing studies with much smaller sample sizes. In cosmological simulations, strong feedback is generally required to produce flat gradients at high redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Anomalies in the electromagnetic response and peculiarities of the domain structure in the magnetic Weyl semimetal Co 3⁢ Sn 2 ⁢S 2

In this paper, we present a comprehensive study of magnetic properties of Co 3 ⁢Sn 2 ⁢S 2 (CoSnS) crystals using macroscopic characterization and observations of the domain structure (DS) in a wide range of easy- and hard-axis fields (𝐻) and temperatures (𝑇). From macroscopic measurements, we derive temperature dependences of the basic magnetic parameters of the material [saturation magnetization 𝑀 𝑠 ⁡(𝑇), uniaxial anisotropy constant 𝐾⁡(𝑇), and exchange stiffness 𝐴⁡(𝑇)] and, based on them, calculate the thermodynamic magnetization 𝑀⁡(𝐻,𝑇) curves and DS parameters for pinning-free samples. We find important qualitative and quantitative differences between the theory and experiment defined by the efficient pinning of domain walls (DWs) in our samples. It turns out that, already at temperatures close to the ferromagnetic transition 𝑇 𝑐 , the DW dynamics falls into the heavy creep regime, resulting in a strong deferral of the DS adjustment into the equilibrium state. Here, we suggest that specific magnetic defects, responsible for pinning and causing field-tuned reproducible domain nucleation patterns observed in our high-quality samples, are pointlike. Recently found magnetic polarons formed around vacancies and impurities, which carry strong diamagnetic moments of spin-orbit nature and are intrinsic for CoSnS and expected in other Weyl semimetals, are a possible source of pinning yielding peculiar 𝑀⁡(𝐻,𝑇) response of CoSnS.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin dynamics and a nearly continuous magnetic phase transition in an entropy-stabilized oxide antiferromagnet

In this work, the magnetic order and the spin dynamics in the antiferromagnetic entropy-stabilized oxide (Mg 0.2 Co 0.2 Ni 0.2 Cu 0.2 Zn 0.2 )O (MgO-ESO) have been studied using muon spin relaxation (μSR) and inelastic neutron scattering. We find that antiferromagnetic order develops gradually in the sample volume as it is cooled below 140 K, becoming fully ordered around 100 K. The spin dynamics show a critical slowing down in the vicinity of the transition, and the magnetic order parameter grows continuously in the ordered state. These results indicate that the antiferromagnetic transition is continuous but proceeds with a Gaussian distribution of ordering temperatures. Additionally, the magnetic contribution to the specific heat determined from inelastic neutron scattering likewise shows a broad feature centered around 120 K. High-resolution inelastic neutron scattering further reveals an initially gapped spectrum at low temperature which sees an increase in a quasielastic contribution upon heating until the ordering temperature.

36 MATERIALS SCIENCE↗

Exploring the High-Pressure Phases of Carbon through X-ray Diffraction of Dynamic Compression Experiments on Sandia’s Z Pulsed Power Facility

The carbon phase diagram is rich with polymorphs which possess very different physical and optical properties ideal for different scientific and engineering applications. An understanding of the dynamically driven phase transitions in carbon is particularly important for applications in inertial confinement fusion, as well as planetary and meteorite impact histories. Experiments on the Z Pulsed Power Facility at Sandia National Laboratories generate dynamically compressed high-pressure states of matter with exceptional uniformity, duration, and size that are ideal for investigations of fundamental material properties. X-ray diffraction (XRD) is an important material physics measurement because it enables direct observation of the strain and compression of the crystal lattice, and it enables the detection and identification of phase transitions. Several unique challenges of dynamic compression experiments on Z prevent using XRD systems typically utilized at other dynamic compression facilities, so novel XRD diagnostics have been designed and implemented. We performed experiments on Z to shock compress carbon (pyrolytic graphite) samples to pressures of 150–320 GPa. The Z-Beamlet Laser generated Mn-Heα (6.2 keV) X-rays to probe the shock-compressed carbon sample, and the new XRD diagnostics measured changes in the diffraction pattern as the carbon transformed into its high-pressure phases. Quantitative analysis of the dynamic XRD patterns in combination with continuum velocimetry information constrained the stability fields and melting of high-pressure carbon polymorphs.

36 MATERIALS SCIENCE↗

Phosphate (U-Th)/He Thermochronology of Apollo 14 Melt Breccia 14311

Our ability to confidently characterize the impact history of the inner solar system is limited by discrepancies in radiometric dates and age interpretations for lunar rocks, impact melts, and recovered meteorites. It is therefore important to explore different thermally sensitive radiometric systems to unravel the timing and extent of the long term impact flux. Low-temperature thermochronology of lunar samples has the potential to provide more complementary geochronological datasets and further test dynamical models related to the evolution of the inner solar system (e.g., [1]). (U-Th)/He dating is based on the production of 4He atoms by radioactive alpha decay of U and Th (and to a lesser extent, Sm) in a crystal and the thermally activated volumetric diffusion of those 4He nuclides. At high temperatures, the crystal is an open system from which 4He can escape; at lower temperatures, 4He may be retained. This retention temperature depends on factors such as crystal structure and volume fraction of radiation damage in the crystal (e.g., [2, 3]), but is significantly lower for phosphate minerals compared to the diffusion of the radiogenic daughter products in other widely used chronometric systems (e.g., ~75°C in terrestrial apatite (U-Th)/He vs. ~500°C in apatite U-Th-Pb vs. ~900°C in zircon U-Th-Pb chronometry). Phosphate (U-Th)/He dating has been used to decipher peak temperatures and cooling rates related to terrestrial impact events (e.g., [4]). Pairing a low-temperature thermochronometer with higher-temperature approaches (i.e., a combined 207Pb-206Pb and (U-Th)/He approach), can therefore resolve multiple impact ages within a given sample or even grain. However, despite its potential, phosphate (U-Th)/He dating has not been reported on any lunar samples. Here we present the first lunar phosphate (U-Th)/He thermochronology on an Apollo 14 impact melt-breccia.

C A Diaz↗

Rotation of X-ray polarization in the glitches of a silicon crystal monochromator

EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the `glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normalization of the fluorescence signal by the incident flux alone is sometimes insufficient to compensate for the glitches. Measurements performed at the state-of-the-art wiggler beamline I20-scanning at Diamond Light Source have shown that the glitches alter the spatial distribution of the sample's quasi-elastic X-ray scattering. Because glitches result from additional Bragg reflections, multiple-beam dynamical diffraction theory is necessary to understand their effects. Here, the glitches of the Si(111) four-bounce monochromator of I20-scanning just above the Ni K edge are associated with their Bragg reflections. A fitting procedure that treats coherent and Compton scattering is developed and applied to a sample of an extremely dilute (100 micromolal) aqueous solution of Ni(NO 3 ) 2 . The depolarization of the wiggler X-ray beam out of the electron orbit is modeled. The fits achieve good agreement with the sample's quasi-elastic scattering with just a few parameters. The X-ray polarization is rotated up to ±4.3° within the glitches, as predicted by dynamical diffraction. These results will help users normalize EXAFS data at glitches.

Sutter, John P.↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

The Physics of Hard Spheres Experiment on MSL-1: Required Measurements and Instrument Performance

The Physics of HArd Spheres Experiment (PHaSE), one of NASA Lewis Research Center's first major light scattering experiments for microgravity research on complex fluids, flew on board the Space Shuttle's Microgravity Science Laboratory (MSL-1) in 1997. Using colloidal systems of various concentrations of micron-sized plastic spheres in a refractive index-matching fluid as test samples, illuminated by laser light during and after crystallization, investigations were conducted to measure the nucleation and growth rate of colloidal crystals as well as the structure, rheology, and dynamics of the equilibrium crystal. Together, these measurements support an enhanced understanding of the nature of the liquid-to-solid transition. Achievement of the science objectives required an accurate experimental determination of eight fundamental properties for the hard sphere colloidal samples. The instrument design met almost all of the original measurement requirements, but with compromise on the number of samples on which data were taken. The instrument performs 2-D Bragg and low angle scattering from 0.4 deg. to 60 deg., dynamic and single-channel static scattering from 10 deg. to 170 deg., rheology using fiber optics, and white light imaging of the sample. As a result, PHaSE provided a timely microgravity demonstration of critical light scattering measurement techniques and hardware concepts, while generating data already showing promise of interesting new scientific findings in the field of condensed matter physics.

Doherty, Michael P.↗

Octafluoropropane Concentration Dynamics on Board the International Space Station

Since activating the International Space Station s (IS9 Service Module in November 2000, archival air quality samples have shown highly variable concentrations of octafluoropropane in the cabin. This variability has been directly linked to leakage from air conditioning systems on board the Service Module, Zvezda. While octafluoro- propane is not highly toxic, it presents a significant chal- lenge to the trace contaminant control systems. A discussion of octafluoropropane concentration dynamics is presented and the ability of on board trace contami- nant control systems to effectively remove octafluoropro- pane from the cabin atmosphere is assessed. Consideration is given to operational and logistics issues that may arise from octafluoropropane and other halo- carbon challenges to the contamination control systems as well as the potential for effecting cabin air quality.

Perry, J. L.↗

Fluid System Stability Analysis Techniques

Fluid systems, or networks, consist of multiple components that work together to achieve some desired thermofluid state. For any generic application, this fluid state can be a combination of the fluid pressure, flow rate, enthalpy, or species concentration. Fluid system components, such as pumps and valves, are often governed by nonlinear differential equations, resulting in complex component-to-component interactions. System-level fluid network stability occurs when the flow through the system can maintain a steady-state solution in the presence of small perturbations, which depends on these component interactions. System instability, however, can go undetected until issues arise during integrated system testing. This presentation explores a method for system designers to think of the fluid network as an assembly of components, each with their own thermofluid surfaces of partial stability, called nullclines. The intersections of all nullclines yields system-level solutions, called equilibrium points. When designers define operating points, they are tuning system parameters so that these equilibrium points move to the desired location in the thermofluid state plane. However, linearization theory shows us that the dynamic behavior around these points can be unstable. The local stability of these equilibrium points can be assessed analytically with eigen-analysis, or numerically by propagating state-plane samples to construct a phase portrait. Investigating a phase portrait can help designers gain a qualitative understanding of a system’s dynamic performance. This understanding can then help inform requirement definitions, component selection, and operational procedures. This presentation includes an example of the phase portrait technique on a system featuring a centrifugal pump and a back-pressure regulator (BPR). Numerical modeling of this system suggests that equilibrium points on the left-hand side of the pump curve are dynamically unstable.

Fluid System↗

Fluid System Stability Analysis Techniques

Fluid systems, or networks, consist of multiple components that work together to achieve some desired thermofluid state. For any generic application, this fluid state can be a combination of the fluid pressure, flow rate, enthalpy, or species concentration. Fluid system components, such as pumps and valves, are often governed by nonlinear differential equations, resulting in complex component-to-component interactions. System-level fluid network stability occurs when the flow through the system can maintain a steady-state solution in the presence of small perturbations, which depends on these component interactions. System instability, however, can go undetected until issues arise during integrated system testing. This presentation explores a method for system designers to think of the fluid network as an assembly of components, each with their own thermofluid surfaces of partial stability, called nullclines. The intersections of all nullclines yields system-level solutions, called equilibrium points. When designers define operating points, they are tuning system parameters so that these equilibrium points move to the desired location in the thermofluid state plane. However, linearization theory shows us that the dynamic behavior around these points can be unstable. The local stability of these equilibrium points can be assessed analytically with eigen-analysis, or numerically by propagating state-plane samples to construct a phase portrait. Investigating a phase portrait can help designers gain a qualitative understanding of a system’s dynamic performance. This understanding can then help inform requirement definitions, component selection, and operational procedures. This presentation includes an example of the phase portrait technique on a system featuring a centrifugal pump and a back-pressure regulator (BPR). Numerical modeling of this system suggests that equilibrium points on the left-hand side of the pump curve are dynamically unstable.

Fluid System↗

High definition large area mapping of geological samples using a Maia detector array in the Nuclear Microprobe

A Maia detector array has been utilized and installed on the CSIRO-MARC Nuclear Microprobe. Maia uses an annular array of 384 silicon detectors to provide a solid-angle of 1.3 sr to improve the collection of X-rays induced by Particle Induced X-ray Emission (PIXE) using a micron focussed MeV proton beam. It features event-by-event data acquisition with dead-time correction and pileup rejection and a total count-rate capacity above 10 M/s, versatile stage and beam scanning modes (coupled to the DAQ-36 system described previously) to cater for a variety of sample configuration and experimental needs, precise measurement of transit time and integration of beam fluence per pixel, and spectral deconvolution of event data in real-time using the Dynamic Analysis method to provide element images during data collection. In this work we demonstrate the system on thin sections made from geological samples extracted from active seafloor hydrothermal vents in the PACMANUS hydrothermal field in Papua New Guinea.

36 MATERIALS SCIENCE↗

Data Requirements for Application of Risk-Based Dynamic Contingency Analysis to Evaluate Hurricane Impact to Electrical Infrastructure in Puerto Rico

This paper presents a risk-based dynamic contingency analysis framework that was used to evaluate the hurricane impact to electrical infrastructure in Puerto Rico. PNNL developed a scalable risk-based framework for identifying high-voltage transmission resilience improvements by classifying and prioritizing high-risk power grid contingencies (system failures) under hurricane impact. The risk-based framework is founded on grid outage definitions with their associated probabilities of occurrence from hurricane events, in combination with an impact assessment derived from detailed dynamic cascading failure analysis. This paper focuses on a discussion around data requirements for transmission resilience planning for hurricane events, derived from the development of the risk-based framework and its application to Puerto Rico. This paper launches an important first step in encouraging the engineering community and power system industry to move towards establishing resilience planning as a routine practice. Since actual results for Puerto Rico contain sensitive information, sample simulation results will be used to illustrate the data requirements and risk-based dynamic cascading framework on the Puerto Rico power grid, as well as demonstrate the potential for such a simulation framework. The paper includes a discussion on the lessons learned, importance and need for improved datasets that are not usually considered in traditional power system planning. The paper will also elaborate on how the scalable simulation framework and datasets might be expanded to larger footprints and leveraged for modelling other types of natural disasters.

DCAT, Puerto Rico, hurricane, Power System Stabili↗