Influence of high temperature on solid state nuclear track detector parameters

This work concerns the influence of high temperatures on tracks induced in solid state nuclear track detectors of the CR-39/PM-355 type. In order to investigate this effect some samples of the detectors were irradiated with energetic protons and {alpha} particles and subsequently heated under controlled temperatures for different periods of time. After heating the samples were etched and the track evolution was analyzed using an optical microscope. The bulk etch rate V{sub B} of the PM-355 material was also determined as a function of heating temperature. The track etch rate V{sub T} values were estimated for craters induced by protons and {alpha} particles from track diameter measurement as a function of heating temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed feedback GaSb based laser diodes with buried grating

We report on the growth, fabrication, and experimental study of distributed feed-back antimonide diode lasers with buried grating. A second order index-coupled grating was defined by interferometric lithography on the top of the laser waveguide and dry etched by reactive ion etching. The grating was then buried thanks to an overgrowth of the top cladding layer using molecular beam epitaxy. The wafer was then processed using standard photolithography and wet etching into 15 μm-wide laser ridges. Single frequency laser emission at a wavelength of 2.2 μm was measured with a side mode suppression ratio of 34 dB, a maximum output power of 30 mW, and a total continuous tuning range of 6.5 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanowire dopant measurement using secondary ion mass spectrometry

A method is presented to improve the quantitative determination of dopant concentration in semiconductor nanowire (NW) arrays using secondary ion mass spectrometry (SIMS). SIMS measurements were used to determine Be dopant concentrations in a Be-doped GaAs thin film and NW arrays of various pitches that were dry-etched from the same film. A comparison of these measurements revealed a factor of 3 to 12 difference, depending on the NW array pitch, between the secondary Be ion yields of the film and the NW arrays, despite being identically doped. This was due to matrix effects and ion beam mixing of Be from the NWs into the surrounding benzocyclobutene that was used to fill the space between the NWs. This indicates the need for etched NWs to be used as doping standards instead of 2D films when evaluating NWs of unknown doping by SIMS. Using the etched NWs as doping standards, NW arrays of various pitches grown by the vapour-liquid-solid mechanism were characterized by SIMS to yield valuable insights into doping mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of GaN-on-GaN vertical p - n diode with regrown p -GaN by metalorganic chemical vapor deposition

Here, to mimic selective-area doping, p -GaN was regrown on an etched GaN surface on GaN substrates by metalorganic chemical vapor deposition. Vertical GaN-on-GaN p - n diodes were fabricated to investigate the effects of the etch-then-regrowth process on device performance. The crystal quality of the sample after each epitaxial step was characterized by X-ray diffraction, where the etch-then-regrowth process led to a very slight increase in edge dislocations. A regrowth interfacial layer was clearly shown by transmission electron microscopy. Strong electroluminescence was observed with three emission peaks at 2.2 eV, 2.8 eV and 3.0 eV, respectively. The forward current density increased slightly with the increasing temperature, while the reverse current density was almost temperature independent indicating tunneling as the reverse transport mechanism. This result is very similar to the reported Zener tunnel diode comprising a high doping profile at the junction interface. High levels of silicon and oxygen concentrations were observed at the regrowth interface with a distribution width of ~100 nm. This work provides valuable information of p -GaN regrowth and regrown GaN p - n diodes, which can serve as an important reference for developing selective doping for advanced GaN power electronics for high voltage and high power applications.

42 ENGINEERING↗

Investigation of vertical GaN-on-GaN p – n diode with regrown p -GaN for operation in Venus and other extreme environments

This Letter reports the performance of vertical GaN-on-GaN p–n diodes with etch-then-regrown p-GaN after exposure to a simulated Venus environment (460 °C, ∼94 bar, containing CO2/N2/SO2 etc., atmosphere) for over 10 days, and compared them to the performance of GaN p–n diodes without the etch-then-regrow process. After the above-mentioned Venus test, temperature-dependent I–V and microscopy investigation were conducted to study the robustness of etch-then-regrow p-GaN and vertical GaN p–n diodes under harsh environments and operation up to 500 °C. p-electrode degradation is found to be the main issue of the device's performance. This is the highest temperature at which such characterization has been conducted for vertical GaN p–n diodes, therefore establishing a critical reference for the development of p-GaN regrown and vertical GaN-based electronics for extreme environments.

Physics↗

Measurement and alleviation of subsurface damage in a thick-crystal neutron interferometer

The construction is described of a monolithic thick-crystal perfect silicon neutron interferometer using an ultra-high-precision grinding technique and a combination of annealing and chemical etching that differs from the construction of prior neutron interferometers. The interferometer is the second to have been annealed after machining and the first to be annealed prior to chemical etching. Monitoring the interference signal at each post-fabrication step provides a measurement of subsurface damage and its alleviation. In this case, the strain caused by subsurface damage manifests itself as a spatially varying angular misalignment between the two relevant volumes of the crystal and is reduced from ~10 -5 rad to ~10 -9 rad by way of annealing and chemical etching.

Chemistry↗

Lithography-Free Mesa Isolation of III–V Solar Cells Through Laser Ablation

Eliminating photolithography from solar cell processing is a significant opportunity for cost reduction for III-V solar cells. Here, in this work, we explore femtosecond laser ablation as an alternative to contact photolithography and wet chemical etching for mesa isolation. We demonstrate both GaAs and GaInP solar cells mesa-isolated by femtosecond laser ablation with minimal to no loss in solar cell performance. We show the best results with a 400 fs UV pulsed laser and a short clean-up etch that also serves as a contact layer removal etch.

14 SOLAR ENERGY↗

Improving Performance of III-V Solar Cells Grown on Spalled Germanium with Ex Situ Substrate Planarization

Controlled spalling allows removal of devices and provides an opportunity for cost reduction through substrate reuse. However, the fracture-based process can leave behind morphological surface features, notably river lines, that can disrupt epitaxial growth and degrade device performance. We investigate the viability of various wet etch chemistries to planarize river lines to ensure high-quality device growth and performance without mechanical repolishing, and so maintain a route towards cost-effective reuse. Etching in a HF: HNO 3 :CH 3 COOH solution effectively planarizes river lines and produces a surface that yields devices with equivalent performance to those grown on epi-ready Ge wafer surfaces. Further studies will focus on optimizing etch composition, temperature, and time to minimize material removal while maintaining a suitable surface for high-quality epitaxy.

germanium↗

Optimization of a plasma immersion ion implantation process for shallow junctions in silicon

A plasma immersion ion implantation (PIII) process has been developed for realizing shallow doping profiles of phosphorus and boron in silicon using an in-house built dual chamber cluster tool. High Si etch rates observed in a 5% PH{sub 3} in H{sub 2} plasma have been ascribed to high concentration of H(α) radicals. Therefore, subsequent work was carried out with 5% PH{sub 3} in He, leading to much smaller etch rates. By optical emission spectroscopy, the radical species H(α), PH*{sub 2}, and PH* have been identified. The concentration of all three species increased with pressure. Also, ion concentrations increased with pressure as evidenced by Langmuir data, with a maximum occurring at 0.12 mbar. The duty cycle of pulsed DC bias has a significant bearing on both the implantation and the etching process as it controls the leakage of positive charge collected at the surface of the silicon wafer during pulse on-time generated primarily due to secondary electron emission. The P implant process was optimized for a duty cycle of 10% or less at a pressure of 0.12 mbar with implant times as low as 30 s. Secondary ion mass spectroscopy showed a P dopant depth of 145 nm after rapid thermal annealing (RTA) at 950 °C for 5 s, resulting in a sheet resistance of 77 Ω/◻. Si n{sup +}/p diodes fabricated with phosphorus implantation using optimized PIII and RTA conditions exhibit J{sub on}/J{sub off} > 10{sup 6} with an ideality factor of nearly 1.2. Using similar conditions, shallow doping profiles of B in silicon have also been realized.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved film quality of plasma enhanced atomic layer deposition SiO{sub 2} using plasma treatment cycle

Chemical, physical, and electrical characteristics of high quality silicon dioxide (SiO{sub 2}) films grown using low temperature plasma enhanced atomic layer deposition (PE-ALD) have been investigated as a buffer layer for three dimensional vertical NAND flash memory devices. The comparative angle resolved x-ray photoelectron spectroscopy studies show the plasma treatment cycle causes to shift the core level binding energy (chemical shifts) in the SiO{sub 2} film. The wet etch rates with respect to plasma treatment cycle times were varied due to curing of the SiO{sub 2} network defects by Ar{sup +} ions and oxygen radicals. It is assumed that the angle between the bonds linking SiO{sub 4} tetrahedra is a critical point understanding the variation in wet etch rate of SiO{sub 2}. The features of wet etch rate of low temperature high quality SiO{sub 2} demonstrated lower than high temperature low-pressure chemical vapor deposition (LP-CVD) SiO{sub 2} values. In addition, the better step-coverage compared to that of the LP-CVD SiO{sub 2} film was achieved from the deep trench structure having the 20:1 aspect ratio. PE-ALD SiO{sub 2} with plasma treatment cycle showed excellent I–V properties with higher breakdown voltage compared to LP-CVD SiO{sub 2} and similar to the thermal SiO{sub 2} carrier transport plot.

36 MATERIALS SCIENCE↗

Measurements and modeling of the impact of weak magnetic fields on the plasma properties of a planar slot antenna driven plasma source

The radial line slot antenna plasma source is a type of surface wave plasma source driven by a planar slot antenna. Microwave power is transmitted through a slot antenna structure and dielectric window to a plasma characterized by a generation zone adjacent to the window and a diffusion zone that contacts a substrate. The diffusion zone is characterized by a very low electron temperature. This renders the source useful for soft etch applications and thin film deposition processes requiring low ion energy. Another property of the diffusion zone is that the plasma density tends to decrease from the axis to the walls under the action of ambipolar diffusion at distances far from where the plasma is generated. A previous simulation study [Yoshikawa and. Ventzek, J. Vac. Sci. Technol. A 31, 031306 (2013)] predicted that the anisotropy in transport parameters due to weak static magnetic fields less than 50 G could be leveraged to manipulate the plasma profile in the radial direction. These simulations motivated experimental tests in which weak magnetic fields were applied to a radial line slot antenna source. Plasma absorption probe measurements of electron density and etch rate showed that the magnetic fields remote from the wafer were able to manipulate both parameters. A summary of these results is presented in this paper. Argon plasma simulation trends are compared with experimental plasma and etch rate measurements. A test of the impact of magnetic fields on charge up damage showed no perceptible negative effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Review of metal-containing resists in electron beam lithography: perspectives for extreme ultraviolet patterning

Background: Metal-containing resists entered the mainstream semiconductor industry process flow to mitigate the low absorbance of extreme ultraviolet (EUV) radiation by thin films of organic resists that lead to poor sensitivity and their inability to handle rigors of development and etching conditions. Aim: The long and rich history of using metal-containing resists in electron beam lithography can offer interesting lessons, pointers, and insights to the relatively newcomer EUV lithography, which is slightly over a decade old. Approach: Electron beam lithography has been enjoying a considerable amount of freedom in the choice of resist materials for close to 50 years; especially the use of metal-containing resists to attain not only single digit nanometer resolution, higher sensitivity, and etch resistance but also lower line-edge roughness. Here, we make a comprehensive historical review of the progress made in the patterning of metal-containing resists in electron beam lithography and derive insights that can be potentially useful in EUV patterning. Perspectives: Small molecular weight resists are proven to be crucial for achieving higher resolution with low line-edge roughness. Simplifying process flow by reducing etch-stack-layers is conceivable with metal-containing resists, along with direct-patterning of functional materials for heterogeneous integration. Efficient contact hole patterning at tighter pitches may be incumbent on progress in positive-tone resist research.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Repair of a Mirror Coating on a Large Optic for High Laser Damage Applications using Ion Milling and Over-Coating Methods.

When an optical coating is damaged, deposited incorrectly, or is otherwise unsuitable, the conventional method to restore the optic often entails repolishing the optic surface, which can incur a large cost and long lead time. We propose three alternative options to repolishing, including (i) burying the unsuitable coating under another optical coating, (ii) using ion milling to etch the unsuitable coating completely from the optic surface, and then recoating the optic, and (iii) using ion milling to etch through a number of unsuitable layers, leaving the rest of the coating intact, and then recoating the layers that were etched. Repairs were made on test optics with dielectric mirror coatings according to the above three options. The mirror coatings to be repaired were quarter wave stacks of HfO 2 and SiO 2 layers for high reflection at 1054 nm at 45° incidence in P-polarization. One of the coating layers was purposely deposited incorrectly as Hf metal instead of HfO 2 to evaluate the ability of each repair method to restore the coating’s high laser-induced damage threshold (LIDT) of 64.0 J/cm 2 . Finally, the repaired coating with the highest resistance to laser-induced damage was achieved using repair method (ii) with an LIDT of 49.0 – 61.0 J/cm 2 .

42 ENGINEERING↗

Methods for improving the damage performance of fused silica polished by magnetorheological finishing

The laser-induced damage threshold of fused-silica samples processed via magnetorheological finishing is investigated for polishing compounds depending on the type of abrasive material and the post-polishing surface roughness. The effectiveness of laser conditioning is examined using a ramped pre-exposure with the same 351-nm, 3-ns Gaussian pulses. Lastly, we examine chemical etching of the surface and correlate the resulting damage threshold to the etching protocol. A combination of etching and laser conditioning is found to improve the damage threshold by a factor of ~3, while maintaining <1-nm surface roughness.

36 MATERIALS SCIENCE↗

Enhanced laser-induced damage performance of all-glass metasurfaces for energetic pulsed laser applications

To fabricate optical components with surface layers compatible with high power laser applications that may operate as antireflective coatings, polarization rotators, or harness physical anisotropy for other uses, metasurfaces are becoming an appealing candidate. In this study, a large-beam (1.05 cm diameter) 351-nm laser-induced damage testing was done on an all-glass metasurface structure composed of cone-like features with a subwavelength spacing of adjacent features. These structures were fabricated on untreated fused silica glass and damage tested, as were structures that were fabricated on fused silica glass that experienced a preliminary etching process to remove the surface Beilby layer that is characteristic of polished fused silica. The laser-induced damage onset for structures on untreated fused silica glass was 19.3 J∙cm -2 , while the sample that saw an initial pretreatment etch exhibited an improved damage onset of 20.4 J∙cm -2 , only 6% short of the reference pretreated glass damage onset of 21.7 J∙cm -2 . For perspective, the National Ignition Facility (NIF) operational average fluence at this wavelength and pulse length is about 10 J/cm2. At a fluence of 25.5 J∙cm -2 , the reference (pretreated) fused silica initiated 5.2 damage sites per mm 2 , while the antireflective metasurface sample with a preliminary etching process treatment initiated 9.8 damage sites per mm 2 . In conclusion, these findings demonstrate that substrate-engraved metasurfaces are compatible with high energy and power laser applications, further broadening their application space.

36 MATERIALS SCIENCE↗

Final Report of “Collaborative research: Fundamental science of low temperature plasma-biological material interactions” (Award# DE-SC0005105)

Low temperature plasma (LTP) treatment of biological tissue is a promising path toward sterilization of bacteria due to its versatility and ability to operate under well-controlled and relatively mild conditions. The present collaborative research of an interdisciplinary team of investigators at University of Maryland, College Park (UMD), and University of California, Berkeley (UCB) focused on establishing our knowledge on low temperature plasma-induced chemical modifications in biomolecules that result in inactivation due to various plasma species, including ions, reactive radicals, and UV/VUV photons. The overall goals of the project were to identify the mechanisms by which low and atmospheric pressure plasma (APP) deactivates endotoxic biomolecules. Additionally, we wanted to understand how deactivation processes depend on the interaction of APP with the environment. Various low pressure plasma sources, a vacuum beam system and several atmospheric pressure plasma sources were used to accomplish these objectives. In our work we elucidated for the first time the role of ions, VUV photons and radicals in biological deactivation of model endotoxic biomolecules, both in a UHV beam system and an inductively coupled, low pressure plasma system, and established the associated atomistic modifications in biomolecules. While we showed that both ions and VUV photons can be very efficient in deactivation of biomolecules, significant etching and/or deep modification (~200 nm) were accompanied by these biological effects. One of the most important findings in this work is that the significant deactivation and surface modification can occur with minimal etching using radical species. However, if radical fluxes and corresponding etch rates are relatively high, for example, at atmospheric pressure, inactivation of endotoxic biomolecule film may require near-complete removal of the film. These findings motivated further work at atmospheric pressure using several types of low temperature plasma sources with modified geometry where radical induced interactions generally dominate due to short mean free paths of ions and VUV photons. In these conditions we demonstrated the importance of environmental interactions of plasma species when APP sources are used to modify biomolecules. This is evident from both gas phase characterization data and in-situ surface characterization of treated biomolecules. Environmental interactions can produce unexpected outcomes due to the complex reactions of reactive species with the atmosphere which determine the composition of reactive fluxes and atomistic changes in biomolecules. Overall, this work elucidated a richer spectrum of scientific opportunities and challenges for the field of low temperature plasma-biomolecule surface interactions than initially anticipated, in particular, for plasma sources operating at atmospheric pressure. The insights produced in this work, e.g. demonstration of the importance of environmental interactions, are generally important for applications of APP to materials modifications. Thus one major contributions of this research has been the establishment of methodologies to study the interaction of plasma with bio-molecules in a systemic and rigorous manner. In particular, our studies of atmospheric pressure plasma sources using very well-defined experimental conditions enabled us to correlate atomistic surface modifications of biomolecules with changes in their biological function. The clarification of the role of ions, VUV photons and radicals in deactivation of biomolecules during low pressure and atmospheric pressure plasma-biomolecule interaction has broad implications, e.g. for the emerging field of plasma medicine. The development of methods to detect the effects of plasma treatment on immune-active biomolecules will lay a fundamental foundation to enhance our understanding of the effect of plasma on biological systems. be helpful in many future studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collaborative Research. Fundamental Science of Low Temperature Plasma-Biological Material Interactions

Low temperature plasma (LTP) treatment of biological tissue is a promising path toward sterilization of bacteria due to its versatility and ability to operate under well-controlled and relatively mild conditions. The present collaborative research of an interdisciplinary team of investigators at University of Maryland, College Park (UMD), and University of California, Berkeley (UCB) focused on establishing our knowledge based with regard to low temperature plasma-induced chemical modifications in biomolecules that result in inactivation due to various plasma species, including ions, reactive radicals, and UV/VUV photons. The overall goals of the project were to identify and quantify the mechanisms by which low and atmospheric pressure plasma deactivates endotoxic biomolecules. Additionally, we wanted to understand the mechanism by which atmospheric pressure plasmas (APP) modify surfaces and how these modifications depend on the interaction of APP with the environment. Various low pressure plasma sources, a vacuum beam system and several atmospheric pressure plasma sources were used to accomplish this. In our work we elucidated for the first time the role of ions, VUV photons and radicals in biological deactivation of representative biomolecules, both in a UHV beam system and an inductively coupled, low pressure plasma system, and established the associated atomistic biomolecule changes. While we showed that both ions and VUV photons can be very efficient in deactivation of biomolecules, significant etching and/or deep modification (~200 nm) accompanied these biological effects. One of the most important findings in this work is the significant radical-induced deactivation and surface modification can occur with minimal etching. However, if radical fluxes and corresponding etch rates are relatively high, for example at atmospheric pressure, endotoxic biomolecule film inactivation may require near-complete removal of the film. These findings motivated further work at atmospheric pressure using several types of low temperature plasma sources, for which radical induced interactions generally dominate due to short mean free paths of ions and VUV photons. For these conditions we demonstrated the importance of environmental interactions when atmospheric pressure plasma sources are used to modify biomolecules. This is evident from both gas phase characterization data and in-situ surface characterization of treated biomolecules. Environmental interactions can produce unexpected outcomes due to the complexity of reactions of reactive species with the atmosphere which determines the composition of reactive fluxes and atomistic changes of biomolecules. Overall, this work clarified a richer spectrum of scientific opportunities and challenges for the field of low temperature plasma-biomolecule surface interactions than initially anticipated, in particular for plasma sources operating at atmospheric pressure. The insights produced in this work, e.g. demonstration of the importance of environmental interactions, are generally important for applications of APP to materials modifications. Thus one major contributions of this research has been the establishment of methodologies to more systematically study the interaction of plasma with bio-molecules. In particular, our studies of atmospheric pressure plasma sources using very well-defined experimental conditions enabled to combine atomistic surface modifications of biomolecules with changes in their biological function. The clarification of the role of ions, VUV photons and radicals in deactivation of biomolecules during low pressure and atmospheric pressure plasma-biomolecule interaction has broad implications, e.g. for the emerging field of plasma medicine. The development of methods to detect the effects of plasma treatment on immune-active biomolecules will be helpful in many future studies.

36 MATERIALS SCIENCE↗