Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physics-informed hybrid modeling methodology for building infiltration

Infiltration is responsible for one-third to one-half of the space conditioning load of a typical residential home, but the modeling of infiltration for building energy modeling is either represented by over-simplified equations or dependent on over-generalized rules of thumb. Here, this paper develops a physics-informed data-driven methodology for modeling infiltration using building-specific empirical measurements. The developed hybrid methodology combines machine-learning categorization and grey-box sub-modeling to improve the accuracy and generalization of commonly used grey-box infiltration models. The developed methodology excels at predicting infiltration by improving the ability to predict infiltration under unseen environmental conditions using machine learning algorithms with physical significance. In a case study conducted using the iUnit, a modular studio apartment experimental test facility located at the National Renewable Energy Laboratory, we use empirical airtightness measurements to fit an infiltration model using the developed methodology. We find that the developed methodology can improve the overall model accuracy by 43% and improve extrapolation by 38%, compared with the model based on the common grey-box infiltration equation. We also notice that the selected features can improve the performance of a pure machine-learning model, indicating that our methodology identifies the features with the most physical significance to infiltration modeling.

97 MATHEMATICS AND COMPUTING↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

The effect of additives on the speed of the crystallization front of xylitol with various degrees of supercooling

Some liquids can be kept in a supercooled or supersaturated metastable state for substantially long periods. Such liquids can be applied as long-term heat storage where the latent heat can be released when needed. As xylitol possesses a relatively high value of latent heat and as it can be easily supercooled, it has promising properties for this application. However, the speed of the crystallization of xylitol is low, leading to a low release rate of latent heat. Several additives have been experimentally tested for the purpose of accelerating the crystallization speed. The effect of the additives on the latent heat, on the melting temperatures, and on the long-term durability of the supercooled state was also measured. The highest speeds of the crystallization front, at a temperature of 22 C, were achieved with methanol as an additive leading to speeds 33 times higher in vertical experiments and in 170 times higher in horizontal ones than with pure xylitol. The improved speed of the crystallization front is mostly caused by the methanol flow currents generated as a result of the separation of methanol during crystallization, and to a lesser extent, as a result of the increase in the speed of the growth of the crystals. (author)

25 ENERGY STORAGE↗

Heat transfer and hydrodynamics analysis of a novel dimpled tube

In the present investigation, heat transfer and hydrodynamics analysis of a new enhanced heat transfer tube with ellipsoidal dimples was carried out. The dimples are disposed to form a certain specified angle between the major axis of the ellipsoid and flow direction, and the direction of the major axis of each adjacent ellipsoidal dimple in the same cross-section is alternated. Experimental tests were carried out with heating water on the shell side with a constant flow rate, and cold air in the tube side with flow rates range from 1 to 55 m{sup 3}/h. The temperatures and pressures for the inlet and outlet of both sides were measured. The heat transfer and pressure drop of the new dimpled tube were investigated and compared with the results of a dimpled tube with spherical dimples and a conventional smooth tube. The computed results indicated that the Nusselt number for ellipsoidal dimpled tube and spherical dimpled tube are 38.6-175.1% and 34.1-158% higher than that for the smooth tube respectively. The friction factors of dimpled tube increase by 26.9-75% and 32.9-92% for ellipsoidal and spherical dimples compared with the smooth tube respectively. It was perceived that ellipsoidal dimple roughness accelerates transition to critical Reynolds numbers down to less than 1000. By integrated performance evaluation of (Nu{sub a}/Nu{sub s})/(f{sub a}/f{sub s}), a maximum of about 87% heat transfer enhancement with the same friction penalty could be achieved by optimize the dimpled tube design. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lignin-based jet fuel and its blending effect with conventional jet fuel

Sustainable aviation fuels (SAFs) must demonstrate specific physical and chemical properties as well as material compatibility (i.e., seal swell) to be used as an aviation turbine fuel. Several alternative jet fuels incorporated in ASTM D7566 are comprised mainly of n/iso-alkanes and can only be blended up to 50 vol% due to material compatibility and density issues. Prior work illustrated the ability of cycloalkanes to replace aromatics’s role in material compatibility. Here, we report the first archival documentation of a feedstock and chemical process to yield a product composition able to complement existing SAF ASTM D7566 annexes. A lignin-based jet fuel (LJF) blend components is generated and composed of mostly C7-C18 mono, di, and tri-cycloalkanes. The neat LJF was blended with conventional jet fuel at 10 vol% (LJF blend) to simulate an ASTM “Fast Track” evaluation process. Fuel properties that are critical to engine operability (ATSM D4054 Tier 3 & 4) were either predicted or experimental tested based on the volume availability. All LJF blend’s critical properties fall within the experience range of conventional jet fuel, with o-ring swelling exceeding the typical range of conventional fuels. Here, these results in total support the potential use of this LJF pathway to complement other SAF pathways and achieve 100% drop-in SAF.

09 BIOMASS FUELS↗

Experimental results of embedded phase change material capsules for increasing the performance of a wrapped heat pump water heater

Herein, to enhance the capacity of heat pump water heaters (HPWHs), high energy density phase change material (PCM) was used in two experimentally tested HPWH prototypes. Preliminary findings showed that in the PCM, stored thermal potential energy could be effectively converted into sensible heat in the water over a slight temperature difference, with the goal of increasing the capacity of hot water above a desired cut-off temperature. This exchange of energy results in an increased amount of hot water necessary for mixing at the location utilized by the consumer. It was also found that for a wrapped HPWH, there was an average increase of 27.7% in the capacity when 7.6 L of novel PCM filled spherical capsules were added to a 22.7 L tank downstream of the HPWH. In the second design (Beta), PCM capsules were immersed into the tank with a cylindrical geometry, and the UEF was increased by 5.5% over the baseline HPWH test result. As for the Beta design, heat loss was reduced significantly compared to a typical HPWH and the Alpha design. Food-grade PCMs were selected as appropriate. The novel encapsulation design increased the effective conductivity inside the capsule by adding metal fins.

42 ENGINEERING↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Training material models using gradient descent algorithms

High temperature design requires accurate constitutive models to describe material inelastic deformation and failure behavior. Oftentimes, calibrating accurate models devolves into the problem of fitting the model parameters against experimental test data. Here, we present the pyopmat package, an open source framework for calibrating constitutive models against experiment data subjected to various loading conditions using machine learning techniques. The package calculates the exact gradient of the model response with respect to the parameters using a combination of automatic differentiation and the adjoint method. Given this exact gradient, we compare the performance of several gradient-based optimization techniques in fitting realistic constitutive models against data. Here, we demonstrate the efficiency and accuracy of our package through example problems using both synthetic data, generated using known parameter sets, under monotonic and cyclic loading conditions and also with an example applying the techniques developed here to actual high temperature creep-fatigue test data.

36 MATERIALS SCIENCE↗

A macro-micro approach for identifying crystal plasticity parameters for necking and failure in nickel-based alloy haynes 282

Here, this work develops a two-scales macro-micro approach to address the challenge in calibrating crystal plasticity microstructural models when samples undergo necking prior to fracture. The crystal plasticity models are crucial for predicting the materials’ plastic deformation and failure at the microstructure level, identifying the materials’ intrinsic properties as well as investigating the microstructure-properties relationships. However, after necking occurs, the experimentally measured stress-strain curves fail to reflect the materials ‘true’ stress-strain behavior and cannot be directly fitted into crystal plasticity models. The proposed macro-micro approach employs a top-down strategy to address this challenge, which has been studied with experimental tests on precipitation-strengthened Ni-based superalloy Haynes® 282®. In this approach, a macro rate-dependent anisotropic plasticity model with Voce-type hardening and Rice-Tracey damage law is first utilized to model the deformation and failure of the tensile bar, and calibrated by matching the stress-strain curves, necking strain, and reduction of area. Especially, to match the testing results under different applied strain rates, the rate-sensitivity parameter m and saturation stress in the elasticity model are modified to incorporate dependence on the local strain rate. Then, the ‘true’ stress-strain behaviors are extracted from the necking zone of the macro-model, which are used to calibrate a micro-model with explicit microstructures and governed by an extended crystal plasticity law. The consistency between the micro-model and macro-model are enforced during calibration. The calibration outcomes from the crystal plasticity model elucidate the materials intrinsic properties for slip, hardening, and failure, which is vital for further investigations into the microstructure-properties relationship and for accurate prediction of the material behavior under various test and service conditions.

36 MATERIALS SCIENCE↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Analysis of the laser welding keyhole using inline coherent imaging

Laser beam welding is a widely used fusion welding process in many industrial applications such as automotive, aerospace, energy, defense, and medical products. Industry has a fundamental need to model the laser welding process to minimize experimental testing and improve confidence in production welds. However, computational models attempting to predict weld formation are limited by an incomplete understanding of the beam-material interactions. As a consequence, these models do not accurately predict the mechanisms associated with laser weld formation. To improve the current state of prediction capabilities, it is vital to better detect/measure the physical aspects of the weld pool during high energy density welding. In this work, a novel real-time laser weld monitoring device using inline coherent imaging (ICI) was used to provide a fundamental understanding of laser weld formation via vaporization. The objective of this work was to investigate and quantify the relationship relating laser weld parameters and the vapor capillary (keyhole) through a state-of-the-art measurement technique. Bead-on-plate laser beam welds were produced with partial penetration on 304L stainless steel, 2205 duplex stainless steel, and Ti-6Al-4V. Keyhole monitoring was performed using a commercially available ICI system to collect keyhole penetration data in real time. These measurements were reconstructed to generate the vapor capillary shape at different welding parameters. Process parameters significantly influenced the keyhole shape and the keyhole root position relative to the process beam. Finally, the keyhole geometry showed distinct differences between the stainless steel alloys and Ti-6Al-4V.

2205↗

Integrated simulation, machine learning, and experimental approach to characterizing fracture instability in indentation pillar-splitting of materials

Measuring fracture toughness of materials at small scales remains challenging due to limited experimental testing configurations. A recently developed indentation pillar-splitting method has shown promise of improved flexibility in fracture toughness measurements at the microscale, partly due to the occurrence of an unusual fracture instability, i.e., a transition from stable to unstable crack propagation. In spite of growing interest in this method, the underlying mechanism of this phenomenon is yet to be elucidated. Furthermore, we provide a comprehensive description of fracture instability in indentation pillar-splitting by combining in situ experiments with high-fidelity simulations based on cohesive zone and J-integral methods. In addition, a machine-learning-based solution for predicting the critical indentation load of fracture instability is established through Gaussian processes regression for broad use of this method by the community.

36 MATERIALS SCIENCE↗

Numerical and experimental analysis of mechanically induced failure in electric vehicle battery modules

Mitigating thermal runaway and cell-to-cell propagation is essential for improving the safety of electric and hybrid vehicles. Enhancing digital twin capabilities to predict battery mechanical abuse is particularly critical for automotive and aerospace applications, where crashworthiness is a key concern. Understanding failure conditions and propagation in battery modules during mechanical abuse is complex due to interactions between structural deformation, heat transfer, electrochemical processes, exothermic reactions and mechanical fracture. While prior studies have focused on modeling cell-level behavior, extending these models to module or pack level is necessary for a system level understating of electric vehicle safety. This study develops coupled large deformation finite element models that simultaneously solve for electrochemistry, material failure, internal short circuit and thermal runaway propagation. The models account for mechanical and thermal interactions between lithium-ion cells and other battery components while the contact interfaces are evolving with time. Model-predicted voltage, temperature and force responses are compared with experimental data for validation. The results demonstrate that the approach captures key failure mechanisms, including thermal propagation through heat transfer, electrical propagation from short circuits in parallel-connected cells, and mechanical propagation via penetration and crack formation. These findings show that computational models are valuable tools for understanding battery module failure and providing insight that can reduce the need for extensive experimental testing.

25 ENERGY STORAGE↗

Controlled dehumidification to extract clean water from a multicomponent gaseous mixture of organic contaminants

Rapid expansion of the unconventional oil and gas extraction has increased American energy independence, but also led to increased production of large amounts of contaminated water. Wastewater from the oil and gas industry contains a wide range of contaminants. Injecting such contaminated water into disposal wells or discharging it to the environment jeopardizes freshwater resources. Conventional and membrane-based wastewater treatment techniques are often not effective choices to treat highly contaminated wastewater; however, a suitable way to remove contaminants from wastewater is to selectively separate water in a process analogous to humidification-dehumidification (HDH). Only a few studies have investigated the use of HDH for wastewater treatment. In this study, a novel HDH system is introduced for treating highly contaminated water, such as oil and gas flowback and produced water. In this HDH process, a non-condensable gas, such as air, mixes with wastewater vapor to facilitate the separation of contaminants. As a result, clean water condenses from the multicomponent gaseous mixture while air carries organic contaminants out of the dehumidification section. A laboratory apparatus was constructed and experiments were performed to investigate the HDH process for wastewater treatment and to study the effects of flow dynamics including air flow rate on the composition of treated water. Different contaminants including benzene, toluene, 2-propanol and 2-butoxyethanol were tested. Experimental results showed that the system can be successfully applied for removing volatile and/or toxic organic contaminants from wastewater. A representative multicomponent mixture of fracking wastewater was successfully treated using the experimental setup and clean water with quality of 98.3% was obtained. It was revealed that increasing the air-to-vapor mass ratio improves purity of treated water. Quantitative analysis showed that by increasing the air-to-vapor mass ratio from 0.6 to 5.9, the fraction of separated 2-propanol through the air was improved from 43% to more than 96% of the initial amount. ASPEN software was employed to simulate equilibrium conditions. Finally, experimental results were observed to have lower mass fraction of residual contaminant in the treated water compared to equilibrium state.

42 ENGINEERING↗

Effect of CeLa addition on the microstructures and mechanical properties of Al-Cu-Mn-Mg-Fe alloy

Development of high strength lithium battery shell alloy is highly desired for new energy automobile industry. The microstructures and mechanical properties of Al-Cu-Mn-Mg-Fe alloy with different CeLa additions were investigated through optical microscopy (OM), X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Rietveld refinement and tensile testing. Experimental results indicate that Al{sub 8}Cu{sub 4}Ce and Al{sub 6}Cu{sub 6}La phases formed due to CeLa addition. Addition of 0.25 wt.% CeLa could promote the formation of denser precipitation of Al{sub 20}Cu{sub 2}Mn{sub 3} and Al{sub 6}(Mn, Fe) phases, which improved the mechanical properties of the alloy at room temperature. However, up to 0.50 wt.% CeLa addition could promote the formation of coarse Al{sub 8}Cu{sub 4}Ce phase, Al{sub 6}Cu{sub 6}La phase and Al{sub 6}(Mn, Fe) phase, which resulted in weakened mechanical properties. - Highlights: •Al-Cu-Mn-Mg-Fe alloys with different CeLa addition were fabricated through casting and rolling. •Al{sub 8}Cu{sub 4}Ce and Al{sub 6}Cu{sub 6}La phases formed after CeLa addition. •Addition of 0.25 wt.% CeLa promoted formation of denser precipitates of Al{sub 20}Cu{sub 2}Mn{sub 3} and Al{sub 6}(Mn, Fe). •Mechanical properties of the alloy was improved after 0.25 wt.% CeLa addition.

36 MATERIALS SCIENCE↗