Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Human speed perception is contrast dependent

When two parallel gratings moving at the same speed are presented simultaneously, the lower-contrast grating appears slower. This misperception is evident across a wide range of contrasts (2.5-50 percent) and does not appear to saturate (e.g. a 50 percent contrast grating appears slower than a 70 percent contrast grating moving at the same speed). On average, a 70 percent contrast grating must be slowed by 35 percent to match a 10 percent contrast grating moving at 2 deg/sec (N = 6). Furthermore, the effect is largely independent of the absolute contrast level and is a quasi-linear function of log contrast ratio. A preliminary parametric study shows that, although spatial frequency has little effect, relative orientation is important. Finally, the misperception of relative speed appears lessened when the stimuli to be matched are presented sequentially.

Stone, Leland S.↗

Diffraction-Based Optical Switch

Method and system for controllably redirecting a light beam, having a central wavelength lambda, from a first light-receiving site to a second light-receiving site. A diffraction grating is attached to or part of a piezoelectric substrate, which is connected to one or two controllable voltage difference sources. When a substrate voltage difference is changed and the diffraction grating length in each of one or two directions is thereby changed, at least one of the diffraction angle, the diffraction order and the central wavelength is controllably changed. A diffracted light beam component, having a given wavelength, diffraction angle and diffraction order, that is initially received at a first light receiving site (e.g., a detector or optical fiber) is thereby controllably shifted or altered and can be received at a second light receiving site. A polynomially stepped, chirped grating is used in one embodiment. In another embodiment, an incident light beam, having at least one of first and second wavelengths, lambda1 and lambda2, is received and diffracted at a first diffraction grating to provide a first diffracted beam. The first diffracted beam is received and diffracted at a second diffraction grating to produce a second diffracted beam. The second diffracted beam is received at a light-sensitive transducer, having at least first and second spaced apart light detector elements that are positioned so that, when the incident light beam has wavelength lambda1 or lambda2 (lambda1 not equal to lambda2), the second diffracted beam is received at the first element or at the second element, respectively; change in a selected physical parameter at the second grating can also be sensed or measured. A sequence of spaced apart light detector elements can be positioned along a linear or curvilinear segment with equal or unequal spacing.

Stevan M Sperno↗

Variable magnification variable dispersion glancing incidence imaging x-ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x-ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x-ray and extreme ultraviolet radiation sources includes a pirmary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carries each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a mutlilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x-ray sensitive photogrpahic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard B.↗

Micro spectrometer for parallel light and method of use

A spectrometer system includes an optical assembly for collimating light, a micro-ring grating assembly having a plurality of coaxially-aligned ring gratings, an aperture device defining an aperture circumscribing a target focal point, and a photon detector. An electro-optical layer of the grating assembly may be electrically connected to an energy supply to change the refractive index of the electro-optical layer. Alternately, the gratings may be electrically connected to the energy supply and energized, e.g., with alternating voltages, to change the refractive index. A data recorder may record the predetermined spectral characteristic. A method of detecting a spectral characteristic of a predetermined wavelength of source light includes generating collimated light using an optical assembly, directing the collimated light onto the micro-ring grating assembly, and selectively energizing the micro-ring grating assembly to diffract the predetermined wavelength onto the target focal point, and detecting the spectral characteristic using a photon detector.

Park, Yeonjoon↗

Single-Mode, Distributed Feedback Interband Cascade Lasers

Single-mode, distributed feedback interband cascade lasers (ICLs) using distributed-feedback gratings (e.g., lateral Bragg gratings) and methods of fabricating such ICLs are provided. The ICLs incorporate distributed-feedback gratings that are formed above the laser active region and adjacent the ridge waveguide (RWG) of the ICL. The ICLs may incorporate a double-ridge system comprising an optical confinement structure (e.g., a RWG) disposed above the laser active region that comprises the first ridge of the double ridge system, a DFB grating (e.g., lateral Bragg grating) disposed above the laser active region and adjacent the optical confinement structure, and an electric confinement structure that passes at least partially through the laser active region and that defines the boundary of the second ridge comprises and the termination of the DFB grating.

Frez, Clifford F.↗

Optically transduced MEMS magnetometer

MEMS magnetometers with optically transduced resonator displacement are described herein. Improved sensitivity, crosstalk reduction, and extended dynamic range may be achieved with devices including a deflectable resonator suspended from the support, a first grating extending from the support and disposed over the resonator, a pair of drive electrodes to drive an alternating current through the resonator, and a second grating in the resonator overlapping the first grating to form a multi-layer grating having apertures that vary dimensionally in response to deflection occurring as the resonator mechanically resonates in a plane parallel to the first grating in the presence of a magnetic field as a function of the Lorentz force resulting from the alternating current. A plurality of such multi-layer gratings may be disposed across a length of the resonator to provide greater dynamic range and/or accommodate fabrication tolerances.

47 OTHER INSTRUMENTATION↗

Textured micrometer scale templates as light managing fabrication platform for organic solar cells

A three-dimensional, microscale-textured, grating-shaped organic solar cell geometry. The solar cells are fabricated on gratings to give them a three-dimensional texture that provides enhanced light absorption. Introduction of microscale texturing has a positive effect on the overall power conversion efficiency of the devices. This grating-based solar cell having a grating of pre-determined pitch and height has shown improved power-conversion efficiency over a conventional flat solar cell. The improvement in efficiency is accomplished by homogeneous coverage of the grating with uniform thickness of the active layer, which is attributed to a sufficiently high pitch and low height of the underlying gratings. Also the microscale texturing leads to suppressed reflection of incident light due to the efficient coupling of the incident light into modes that are guided in the active layer.

14 SOLAR ENERGY↗

Ultra-high Resolution Optics for EUV and Soft X-ray Inelastic Scattering

We describe a revolutionary new approach to high spectral resolution soft x-ray optics. Conventionally in the soft x-ray energy range, high spectral resolution is obtained by use of a relatively low line density grating operated in 1st order with small slits. This severely limits throughput. This limitation can be removed by use of a grating either in very high order, or with very high line density, if one can maintain high diffraction efficiency. We have developed a new technology for achieving both of these goals which should allow high throughput spectroscopy, at resolving powers of up to 10{sup 6} at 1 keV. Such optics should provide a revolutionary advance for high resolution lifetime free spectroscopy, such as RIXS, and for pulse compression of chirped beams. We report recent developmental fabrication and characterization of a prototype grating optimized for 14.2 nm EUV light. The prototype grating with a 200 nm period of the blazed grating substrate coated with 20 Mo/Si bilayers with a period of 7.1 nm demonstrates good dispersion in the third order (effective groove density of 15,000 lines per mm) with a diffraction efficiency of more than 33%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sub-Wavelength Imaging of Photo-Induced Refractive Index Pattern in Chalcogenide Glass Films

Mapping of refractive index patterns with sub-wavelength resolution is achieved using Near-field Scanning Optical Microscopy (NSOM) in reflection mode. Imaging of index pattern is performed on surface gratings photo-imprinted in As2S3 films. The NSOM is adapted with a near infrared laser which wavelength (785 nm) is chosen to be within the transparency window of the glass film therefore allowing consistent measure of reflected light. Quantitative measurements of photo-induced index changes can then be obtained from knowledge of the initial film index. Images of gratings with a period of 0.5 micron are easily collected therefore demonstrating sub-wavelength spatial resolution. The technique permits to concurrently obtain a topographic image and index image of the gratings thereby permitting to quantify the extent of photodarkening and photoexpansion simultaneously. It is shown that relief gratings tend to vanish in films aged in air for several months however the index gratings remain.

36 MATERIALS SCIENCE↗

Freestanding diffractive optical elements as light extractors for burning plasma experiments

Optical diagnostics will be critical for the operation and performance assessment of burning plasma experiments, such as ITER. At the same time, extracting light for these diagnostics with reflective mirrors becomes difficult in the burning plasma environment due to the deleterious effects of the prolonged exposure on plasma and nuclear radiations. As an alternative, we explore the possibility to use freestanding diffractive optical elements, such as transmission gratings and zone plates, as light extractors. Since in diffractive systems, light is deflected by periodic slits rather than by a surface, these may withstand plasma exposure with less degradation of their optical properties. To investigate this possibility, we developed freestanding transmission gratings for the visible range and exposed them to conditions resembling (or even exceeding) those expected for the ITER 'first mirrors.' The results of this study indicate that the gratings can withstand high heat fluxes and plasma and energetic radiation bombardment. Additionally, in contrast to the reflective elements, the extraction efficiency of diffractive elements may even improve with plasma exposure, which is possibly due to the shaping and thinning of the grating bars by plasma erosion. Moreover, in tightly collimated configurations, even very thin gratings can be used to extract light from hot fusion plasmas, as demonstrated by our tests of an extreme ultraviolet extractor at the National Spherical Torus Experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution imaging spectrometer for recording absolutely calibrated far ultraviolet spectra from laser-produced plasmas

An imaging spectrometer was designed and fabricated for recording far ultraviolet spectra from laser-produced plasmas with wavelengths as short as 155 nm. The spectrometer implements a Cassegrain telescope and two gratings in a tandem Wadsworth optical configuration that provides diffraction limited resolution. Spectral images were recorded from plasmas produced by the irradiation of various target materials by intense KrF laser radiation with 248 nm wavelength. Two pairs of high-resolution gratings can be selected for the coverage of two wavebands, one grating pair with 1800 grooves/mm and covering approximately 155-175 nm and another grating pair with 1200 grooves/mm covering 230-260 nm. The latter waveband includes the 248 nm KrF laser wavelength, and the former waveband includes the wavelength of the two-plasmon decay instability at (2/3) the KrF laser wavelength (165 nm). The detection media consist of a complementary metal oxide semiconductor imager, photostimulable phosphor image plates, and a linear array of 1 mm{sup 2} square silicon photodiodes with 0.4 ns rise time. The telescope mirrors, spectrometer gratings, and 1 mm{sup 2} photodiode were calibrated using synchrotron radiation, and this enables the measurement of the absolute emission from the laser-produced plasmas with temporal, spatial, and spectral resolutions. The spectrometer is capable of measuring absolute spectral emissions at 165 nm wavelength as small as 5x10{sup -7} J/nm from a plasma source area of 0.37 mm{sup 2} and with 0.4 ns time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosis of gas temperature, electron temperature, and electron density in helium atmospheric pressure plasma jet

The optical emission spectra of helium atmospheric pressure plasma jet (APPJ) are captured with a three grating spectrometer. The grating primary spectrum covers the whole wavelength range from 200 nm to 900 nm, with the overlapped grating secondary spectrum appearing from 500 nm to 900 nm, which has a higher resolution than that of the grating primary spectrum. So the grating secondary spectrum of OH (A{sup 2}{Sigma} {sup +}({upsilon} Prime = 0) {yields} X{sup 2}{Pi}({upsilon} Double-Prime = 0)) is employed to calculate the gas temperature (T{sub g}) of helium APPJ. Moreover, the electron temperature (T{sub e}) is deduced from the Maxwellian electron energy distribution combining with T{sub g}, and the electron density (n{sub e}) is extracted from the plasma absorbed power. The results are helpful for understanding the physical property of APPJs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alignment of chirped-pulse compressor

An original method of alignment of grating compressors for ultrahigh-power CPA laser systems is proposed. The use of this method for adjustment of the grating compressor of a PEARL subpetawatt laser complex made it possible to align the diffraction gratings with a second accuracy in all three angular degrees of freedom, including alignment of the grooves, and to adjust the angles of beam incidence on the grating with a high accuracy. A simple method for measuring the difference in the groove densities of gratings with accuracy better than 0.005 lines mm{sup -1} is proposed and tested. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the formation of a microrelief on ZnSe- and CdSe-crystal surfaces ablated by excimer KrF-laser radiaton

One-dimensional gratings with a period of 0.5−2.3 μm are formed on the surfaces of CdSe and ZnSe crystals ablated by two interfering radiation beams of a nanosecond excimer KrF laser. Investigated are the dependences of the shape and depth of gratings on the energy density under irradiation by a single pulse, and on the number of pulses at a given energy density. The maximum grating depth is estimated as ∼0.57 of the period. By forming a one-dimensional grating with a period of 1.5 μm and a depth of 0.53 μm on the CdSe-crystal surface, this surface becomes antireflective at a wavelength of 4 μm. The surface reflectivity is reduced by 88 %. A possibility of forming two-dimensional gratings having periods of 1 and 1.5 μm is demonstrated. (paper)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fabrication of high aspect ratio TiO{sub 2} and Al{sub 2}O{sub 3} nanogratings by atomic layer deposition

The authors report on the fabrication of TiO{sub 2} and Al{sub 2}O{sub 3} nanostructured gratings with an aspect ratio of up to 50. The gratings were made by a combination of atomic layer deposition (ALD) and dry etch techniques. The workflow included fabrication of a Si template using deep reactive ion etching followed by ALD of TiO{sub 2} or Al{sub 2}O{sub 3}. Then, the template was etched away using SF{sub 6} in an inductively coupled plasma tool, which resulted in the formation of isolated ALD coatings, thereby achieving high aspect ratio grating structures. SF{sub 6} plasma removes silicon selectively without any observable influence on TiO{sub 2} or Al{sub 2}O{sub 3}, thus revealing high selectivity throughout the fabrication. Scanning electron microscopy was used to analyze every fabrication step. Due to nonreleased stress in the ALD coatings, the top parts of the gratings were observed to bend inward as the Si template was removed, thus resulting in a gradual change in the pitch value of the structures. The pitch on top of the gratings is 400 nm, and it gradually reduces to 200 nm at the bottom. The form of the bending can be reshaped by Ar{sup +} ion beam etching. The chemical purity of the ALD grown materials was analyzed by x-ray photoelectron spectroscopy. The approach presented opens the possibility to fabricate high quality optical metamaterials and functional nanostructures.

36 MATERIALS SCIENCE↗

Ultra-high Resolution Optics for EUV and Soft X-ray Inelastic Scattering

We describe a revolutionary new approach to high spectral resolution soft x-ray optics. Conventionally in the soft x-ray energy range, high spectral resolution is obtained by use of a relatively low line density grating operated in 1st order with small slits. This severely limits throughput. This limitation can be removed by use of a grating either in very high order, or with very high line density, if one can maintain high diffraction efficiency. We have developed a new technology for achieving both of these goals which should allow high throughput spectroscopy, at resolving powers of up to 106 at 1 keV. Such optics should provide a revolutionary advance for high resolution lifetime free spectroscopy, such as RIXS, and for pulse compression of chirped beams. We report recent developmental fabrication and characterization of a prototype grating optimized for 14.2 nm EUV light. The prototype grating with a 200 nm period of the blazed grating substrate coated with 20 Mo/Si bilayers with a period of 7.1 nm demonstrates good dispersion in the third order (effective groove density of 15,000 lines per mm) with a diffraction efficiency of more than 33percent.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale ultrafast lattice modulation with a free-electron laser

Ultrafast optical laser-based techniques have enabled the probing of atomistic processes at their intrinsic temporal scales with femto- and attosecond resolution. However, the long wavelengths of optical lasers have prevented their interrogation and manipulation with nanoscale spatial specificity. Advances in hard X-ray free-electron lasers have enabled progress in developing X-ray transient-grating spectroscopy, a technique that aims to coherently control elementary excitations with nanoscale X-ray standing waves. Thus far, the realization of this technique at the nanoscale has been a challenge. Here we demonstrate X-ray transient-grating spectroscopy with spatial periods of the order of 10 nm via the subfemtosecond synchronization of two hard X-ray pump pulses at a precisely controlled crossing angle. This creates a thermal grating and preferentially excites coherent longitudinal acoustic phonon modes with the transient-grating wavevector. On probing with a third, variably delayed, X-ray pulse with the same photon energy, time-and-wavevector-resolved measurements of the modulation of the induced scattering intensity provide evidence of ballistic thermal transport at nanometre scales. Finally, these results highlight the potential of X-ray transient gratings as a powerful platform for studying nanoscale transport in condensed matter and the coherent control of nanoscale dynamics.

nonlinear optics↗

Low energy soft x-ray emission spectrometer at BL-09A in NewSUBARU

A compact soft X-ray emission spectrometer for the energy region of 50-600 eV has been designed and constructed for the long undulator beamline BL-09A in the NewSUBARU synchrotron radiation (SR) facility. The optical design of the spectrometer is based on a grazing incidence flat-field spectrometer using a valid line-spacing grating. The average groove density of the grating is 2000 L/mm, and the angle of incidence to the grating is 86.5 deg. The distances from the slit to the grating and from the grating to the CCD are 355 mm and 650 mm, respectively. The energy resolution, E/ΔE, was estimated to be greater than 1000 in the energy range of 50-600 eV. Spectra of K-emission X-rays of several light elements, such as B, C, N, and O, from various samples were successfully obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗