Search NASA⌕ Search

SEARCH · Search NASA

Results for “high loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Solvent-Free Preparation of High Energy, Binder-Free Electrodes Enabled by Dry Compressible Holey Graphene

Graphene is an atomically thick sheet consisting of a graphitic carbon network with excellent mechanical strength, electrical and thermal conductivity, and chemical stability. Holey graphene, a structural derivative of graphene, has an array of through-the-thickness holes across the lateral surface of the nanosheet. The presence of these holes has minimal detrimental effect on the graphene properties and leads to enhanced performance in applications such as electronics, sensors, and energy storage. For example, these holes allow more facile cross-plane ion and gas transport than intact graphene, making holey graphene an ideal electrode material for electrochemical energy storage. This presentation will focus on the ability of holey graphene to be compression molded into robust articles or architectures under solvent-free conditions without the need for potentially parasitic binders. The unique dry compressibility of holey graphene has enabled facile fabrication of high mass loading electrodes with both high density and high porosity, which have found use in supercapacitors and various high-energy battery systems such as lithium-oxygen, lithium-sulfur, and lithium-selenium batteries.

Yi Lin↗

High frequency medium voltage drive system for high speed machine applications

In one aspect, a medium voltage power converter includes a plurality of slices each having: a transformer including a plurality of primary windings to couple to a utility source of input power and a plurality of secondary windings; and a plurality of power cubes coupled to the plurality of secondary windings, each of the plurality of power cubes comprising a low frequency front end stage, a DC link, and a high frequency silicon carbide (SiC) inverter stage to couple to a high frequency load or to a high speed machine.

Ledezma, Enrique↗

Aerosol properties and their influences on low warm clouds during the Two-Column Aerosol Project

Twelve months of measurements collected during the Two-ColumnAerosol Project field campaign at Cape Cod, Massachusetts, which started inthe summer of 2012, were used to investigate aerosol physical, optical, andchemical properties and their influences on the dependence of clouddevelopment on thermodynamic (i.e., lower tropospheric stability, LTS)conditions. Relationships between aerosol loading and cloud properties underdifferent dominant air-mass conditions and the magnitude of the firstindirect effect (FIE), as well as the sensitivity of the FIE to differentaerosol compositions, are examined. The seasonal variation in aerosol numberconcentration (Na) was not consistent with variations in aerosoloptical properties (i.e., scattering coefficient, σs, andcolumnar aerosol optical depth). Organics were found to have a largecontribution to small particle sizes. This contribution decreased during theparticle growth period. Under low-aerosol-loading conditions, the liquidwater path (LWP) and droplet effective radius (DER) significantly increasedwith increasing LTS, but, under high-aerosol-loading conditions, LWP and DERchanged little, indicating that aerosols significantly weakened thedependence of cloud development on LTS. The reduction in LWP and DER fromlow- to high-aerosol-loading conditions was greater in stable environments,suggesting that clouds under stable conditions are more susceptible toaerosol perturbations than those under more unstable conditions. Highaerosol loading weakened the increase in DER as LWP increased andstrengthened the increase in cloud optical depth (COD) with increasing LWP,resulting in changes in the interdependence of cloud properties. Under bothcontinental and marine air-mass conditions, high aerosol loading cansignificantly increase COD and decrease LWP and DER, narrowing theirdistributions. Magnitudes of the FIE estimated under continental air-massconditions ranged from 0.07±0.03 to 0.26±0.09 with a meanvalue of 0.16±0.03 and showed an increasing trend as LWP increased.The calculated FIE values for aerosols with a low fraction of organics aregreater than those for aerosols with a high fraction of organics. Thisimplies that clouds over regions dominated by aerosol particles containingmostly inorganics are more susceptible to aerosol perturbations, resultingin larger climate forcing, than clouds over regions dominated by organicaerosol particles.

54 ENVIRONMENTAL SCIENCES↗

Normal Component of Induced Velocity for Entire Field of a Uniformly Loaded Lifting Rotor with Highly Swept Wake as Determined by Electromagnetic Analog

Values of the normal component of induced velocity throughout the entire field of a uniformly loaded r(rotor at high high speed are presented in the form of charts and tables. Many points were found by an electromagnetic analog, details of which are given. Comparisons of computed and analog values for the induced velocity indicate that the latter are sufficiently accurate for engineering purposes.

Castles, Walter, Jr.↗

Buffet Load Alleviation

High performance aircraft are, by their very nature, often required to undergo maneuvers involving high angles of attack. Under these conditions unsteady vortices emanating from the wing and the fuselage will impinge on the twin fins (required for directional stability) causing excessive buffet loads, in some circumstances, to be applied to the aircraft. These loads result in oscillatory stresses, which may cause significant amounts of fatigue damage. Active control is a possible solution to this important problem. A full-scale test was carried out on an F/A-18 fuselage and fins using piezoceramic actuators to control the vibrations. Buffet loads were simulated using very powerful electromagnetic shakers. The first phase of this test was concerned with the open loop system identification whereas the second stage involved implementing linear time invariant control laws. This paper looks at some of the problems encountered as well as the corresponding solutions and some results. It is expected that flight trials of a similar control system to alleviate buffet will occur as early as 2001.

Ryall, T. G.↗

Laser velocimeter measurements of the flow field generated by a forward-swept propfan during flutter

Results are presented from an investigation to measure the flow field generated by a forward-swept propfan operating in flutter at a low forward velocity. For comparison to the flutter condition, flow field data are also presented for a slightly reduced rotational speed just below flutter. The forward-swept propfan was tested as the front rotor of a counterrotating pusher propeller. A laser Doppler velocimeter (LDV) was used to measure the velocity field in planes normal to the model centerline downstream of the rotor and in planes of constant radius within the blade passages at each operating condition. The mean time-averaged flow about the blades did not change drastically as the propfan rotational speed was increased from the stable operating point to the flutter condition. No regions of flow separation could be identified in the data plots of the mean intrablade flow field. The relative flow about the blades remained subsonic during flutter operation. The blades were found to have a higher than expected tip loading at both operating conditions. This is thought to have been caused by the outer blade sections twisting under load to higher than expected effective blade angles. This high tip loading resulted in strong vortices and a very nonuniform flow downstream of the tips of the forward-swept blades. This high tip loading may also have caused the blade flutter.

Podboy, Gary G.↗

Laser velocimeter measurements of the flow field generated by a forward-swept propfan during flutter

Results are presented from an investigation to measure the flow field generated by a forward-swept propfan operating in flutter at a low forward velocity. For comparison to the flutter condition, flow field data are also presented for a slightly reduced rotational speed just below flutter. The forward-swept propfan was tested as the front rotor of a counterrotating pusher propeller. A laser Doppler velocimeter (LDV) was used to measure the velocity field in planes normal to the model centerline downstream of the rotor and in planes of constant radius within the blade passages at each operating condition. A comparison of the data taken at the two different operating conditions indicated that the mean, time-averaged flow about the blades did not change drastically as the propfan rotational speed was increased from the stable operating point to the flutter condition. No regions of flow separation could be identified in the data plots of the mean intrablade flow field. The data also indicate that the relative flow about the blades remained subsonic during flutter operation. The blades were found to have a higher than expected tip loading at both operating conditions. This is thought to have been caused by the outer blade sections twisting under load to higher than expected effective blade angles. This high tip loading resulted in strong vortices and a very nonuniform flow downstream of the tips of the forward-swept blades. This high tip loading may also have caused the blade flutter.

Podboy, Gary G.↗

The yield behavior of polyethylene tubes subjected to biaxial loadings

High-density polyethylene is subjected to biaxial states of stress to examine the yield behavior of the semicrystalline thermoplastic under constant octahedral shear-stress rates. Combinations of internal pressures and axial loads are applied to thin-walled tubes of polyethylene, and the strain response in the axial and hoop directions are measured. The polyethylene specimens are found to be anisotropic, and the experimental measurements are compared to yield criteria that are applicable to isotropic and anisotropic materials.

Semeliss, M.↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings: Preprint

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

27 ARPA - Advanced Research Projects Agency-Energy↗

Generation of high-amplitude soliton waves in crystalline materials of different dimensions under high radiative, dynamic, and temperature loads

It is shown that beams of high-amplitude supersonic breather solitons, phonons, and subsonic excitations of new type (torsions) are generated in crystalline materials of different dimensions under high radiative and dynamic loads near the stability threshold. The dispersion dependences of solitons and phonons in 1D crystals are presented. It is shown that, in 2D crystals beams consisting of six or two (depending on the bombarding particle direction), breather solitons are generated and propagate in certain crystallographic directions. The masses of soliton excitations as particles (coupled complexes of massless phonons) have been determined. It is shown that the subsonic soliton waves of a new type with torsion atomic vibrations are generated in 3D nanotubes, along with supersonic soliton waves of longitudinal vibrations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New Particle Formation and Growth in an Isoprene-Dominated Ozark Forest: From Sub-5 nm to CCN-Active Sizes

Particle Investigations at a Northern Ozarks Tower: NOx, Oxidant, Isoprene Research (PINOT-NOIR) were conducted in a Missouri forest dominated by isoprene emissions, from May to October 2012. This study presents results of new particle formation (NPF) and the growth of new particles to cloud condensation nuclei (CCN)-active sizes (~100 nm) observed from this field campaign. The measured sub-5 nm particles were up to ~20000 cm-3 during a typical NPF event. Nucleation rates J1 were relatively high (11.0±10.6 cm-3s-1), and one order of magnitude higher than formation rates of 5 nm particles (J5). Sub-5 nm particle events were observed on 64% of the measurement days, with a high preference in biogenic volatile organic compounds (BVOCs)- and SO2-poor northwesterly (90%) air masses than in BVOCs-rich southerly air masses (13%). About 80% of sub-5 nm particle events led to the further growth. While high temperatures and high aerosol loadings in the southerly air masses were not favorable for nucleation, high BVOCs in the southerly air masses facilitated the growth of new particles to CCN-active sizes. In overall, 0.4-9.4% of the sub-5 nm particles grew to CCN-active sizes within a NPF event. During a regional NPF event period that took place consecutively over several days, concentrations of CCN size particles increased by a factor of 5 in average. This enhanced production of CCN particles from new particles was commonly observed during all 13 regional NPF events observed during the campaign.

cloud condensation nuclei, isoprene, BVOC↗

Spectral feature design for data compression in high dimensional multispectral data

Data transmission loads of high dimensional remote sensor systems can be greatly reduced by applying generalized Karhunen-Loeve transform as a feature design technique. Two spectral feature design approaches based upon the generalized K-L transform are developed to compress information effectively. Six sets of field data from Kansas and North Dakota on three different dates each are used to test the methods. Spatially, temporally and spatially/temporally combined data sets are formed in this paper to test the robustness property of the schemes. The probability of correct classification using Landsat MSS, Thematic Mapper bands and the proposed bands are found and compared. The comparison shows that the results are improved by the proposed methods, and they appear to be satisfactorily robust. The overall data compression ratio in this paper is about 100/16, i.e., about 6 to 1 with no loss in classification accuracy.

Chen, C.-C. Thomas↗

Kinetic study of treatment of wastewater contains food preservative agent by anaerobic baffled reactor : An overview

The characteristic of wastewater of food industries with preservative substances is high content of organic substances, degradable and high total suspended solid. High organic content in this waste forced the treatment is biologically and pointed out to anaerobic treatment. Anaerobic showed the better performance of degradation than aerobic for high content organic and also for toxic materials. During that day the treatment of food wastewater is aerobically which is high consume of energy required and high volume of sludge produced. The advantage of anaerobic is save high energy, less product of sludge, less requirement of nutrients of microorganism and high efficiency reduction of organic load. The high efficiency of reduction will reduce the load of further treatment, so that, the threshold limit based on the regulation would be easy to achieve. Research of treatment of wastewater of food industries would be utilized by both big scale industries and small industries using addition of preservative substances. The type reactor of anaerobic process is anaerobic baffled reactor that will give better contact between wastewater and microorganism in the sludge. The variables conducted in this research are the baffled configuration, sludge height, preservative agent contents, hydralic retention time and influence of micro nutrients. The respons of this research are the COD effluent, remaining preservative agent, pH, formation of volatile fatty acid and total suspended solid. The result of this research is kinetic model of the anaerobic baffled reactor, reaction kinetic of preservative agent degradation and technology of treatment wastewater contains preservative agent. The benefit of this research is to solve the treatment of wastewater of food industries with preservative substance in order to achieve wastewater limit regulation and also to prevent the environmental deterioration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Speed Shaft Bearing Loads Testing and Modeling in the NREL Gearbox Reliability Collaborative: Preprint

Bearing failures in the high speed output stage of the gearbox are plaguing the wind turbine industry. Accordingly, the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) has performed an experimental and theoretical investigation of loads within these bearings. The purpose of this paper is to describe the instrumentation, calibrations, data post-processing and initial results from this testing and modeling effort. Measured HSS torque, bending, and bearing loads are related to model predictions. Of additional interest is examining if the shaft measurements can be simply related to bearing load measurements, eliminating the need for invasive modifications of the bearing races for such instrumentation.

17 WIND ENERGY↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗