Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Toward equitable environmental exposure modeling through convergence of data, open, and citizen sciences: an example of air pollution exposure modeling amidst increasing wildfire smoke

Exposure modeling is critical in environmental epidemiology and human health but may face challenges (e.g., skewed data, unequal error, context-insensitive validation, and computational demands). Modeling decisions reflect the intended use of the models and the values that modelers prioritize. We aimed to provide a conceptual framework and machine learning (ML) modeling protocols that address these issues. With 500m-gridded hourly PM 2.5 and O 3 levels in Illinois before, during, and after the 2023 Canadian wildfire season as a motivating example, we conducted modeling experiments to evaluate modeling methods, guided by three domains we propose based on theories of science: 1) Data Diversity, leveraging open and citizen science data to enhance inclusivity, parsimony, and representativeness; 2) Equitable Accuracy, ensuring fairly distributed uncertainties across subpopulations; and 3) Sustainable Modeling, balancing accuracy with reducing computational demands to promote accessibility for under-resourced researchers. Here, we found that ML with publicly available data can achieve high accuracy. Depending on methods, performance may vary substantially, even with identical input data. Large but skewed data may reduce performance. Misuse of cross-validation protocols can underestimate prediction error; although we observed R 2 s of ∼98 %, the modeled estimates varied significantly, indicating the need for careful model validation. By using new modeling protocols including representativeness-considered training and validation data and a new loss function, we achieved high agreement between estimates and ground-based measurements (e.g., R 2 = ∼90 % for PM 2.5 ; ∼80 % for O 3 ), equally distributed errors across sociodemographic strata and urban–rural divides, and reduction in computation time—from several weeks or months to a few days.

Exposure assessment↗

Chemical specificity in polyzwitterion-polyelectrolyte coacervates: polycations vs polyanions

Aqueous solutions containing polyzwitterions and polyelectrolytes were studied to probe the effects of chemical specificity on the complexation among different types of chains and resulting liquid–liquid phase separation (coacervation). Two kinds of blends were studied. A polyzwitterion, poly(sulfobetaine methacrylate) (PSBMA), was blended with either (1) a polycation, poly(diallydimethylammonium chloride) (PDADMAC), or (2) a polyanion, sodium poly(styrene sulphonate) (NaPSS). Coacervation was observed in both blends after equilibration, while the freshly prepared blend solutions exhibited distinct behavior dependent on the mixing protocols. Mixing solutions of the polyzwitterions and the polycations led to coacervation almost instantaneously. In contrast, the blends containing the same polyzwitterions and the polyanions exhibited no such coacervation by following the same mixing protocol. However, blends prepared after dissolving a solid mixture containing the same polyzwitterions and the polyanions in water exhibited coacervation. Based on the small-angle X-ray scattering (SAXS), cryo-electron microscopy, and rheology measurements, complexation and coacervation in the polyzwitterion-polyelectrolyte blends is rationalized in terms of the entropy change associated with reorganization of solvent (water), which appears to be larger in the polyzwitterion-polycation case in comparison with the polyzwitterion-polyanion blends. These results highlight the importance of chemical specificity and mixing protocols leading to metastable structures in designing a new class of materials based on macromolecular complexation of polyzwitterions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of thorium, uranium, and rare earths from a strip solution generated from coarse coal refuse

This work systematically evaluated the separation performance of thorium, uranium, and rare earths when coal and coal byproduct were utilized as a non-traditional feedstock for rare earth production. A synthetic solution was prepared following the elemental composition of a strip solution generated from coarse coal refuse and used throughout the study. Various separation techniques including selective precipitation, solvent extraction, and a modified experimental protocol incorporating the two were applied to extract rare earths while minimizing the non-selective recovery of thorium and uranium into the product stream. Test results indicate that selective precipitation was effective for the removal of thorium at a pH value approaching 5 while solvent extraction preferentially removed uranium from rare earths. Therefore, a modified experimental protocol consisting of both selective precipitation and solvent extraction was subsequently developed and implemented. The findings following the modified experimental protocol indicate that extractant concentration, solvent extraction feed pH, and organic to aqueous (O/A) ratio all played a significant role in the removal of uranium. Among all the tests conducted, the best separation performance was achieved using a one-stage precipitation at a pH value of 4.8, 50 v% TBP, solvent extraction feed pH of 3.5, and an O/A ratio of 3, which corresponded to an overall rare earth, thorium, and uranium recovery of 79.6%, 0%, and 3.1%, respectively.

01 COAL, LIGNITE, AND PEAT↗

Quality Assurance Issues in Conducting Multi-Institutional Advanced Technology Clinical Trials

The National Cancer Institute-sponsored Advanced Technology Quality Assurance (QA) Consortium, which consisted of the Image-Guided Therapy QA Center, Radiation Therapy Oncology Group, Radiological Physics Center, Quality Assurance Review Center, and Resource Center for Emerging Technologies, has pioneered the development of an infrastructure and QA method for advanced technology clinical trials that requires volumetric digital data submission of a protocol patient's treatment plan and verification data. In particular, the Image-Guided Therapy QA Center has nearly 15 years experience in facilitating QA review for Radiation Therapy Oncology Group advanced technology clinical trials. This QA process includes (1) a data integrity review for completeness of protocol required elements, the format of data, and possible data corruption, and recalculation of dose-volume histograms; (2) a review of compliance with target volume and organ-at-risk contours by study chairs; and (3) a review of dose prescription and dose heterogeneity compliance by the Radiation Therapy Oncology Group Headquarters Dosimetry Group or the Radiological Physics Center dosimetrists (for brachytherapy protocols). This report reviews the lessons learned and the QA challenges presented by the use of advanced treatment modalities in clinical trials requiring volumetric digital data submission.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast-Conserving Therapy: Radiotherapy Margins for Breast Tumor Bed Boost

Purpose: To quantify the interfraction position variability of the excision cavity (EC) and to compare the rib and breast surface as surrogates for the cavity. Additionally, we sought to determine the required margin for on-line, off-line and no correction protocols in external beam radiotherapy. Methods and Materials: A total of 20 patients were studied who had been treated in the supine position for 28 daily fractions. Cone-beam computed tomography scans were regularly acquired according to a shrinking action level setup correction protocol based on bony anatomy registration of the ribs and sternum. The position of the excision area was retrospectively analyzed by gray value cone-beam computed tomography-to-computed tomography registration. Subsequently, three setup correction strategies (on-line, off-line, and no corrections) were applied, according to the rib and breast surface registrations, to estimate the residual setup errors (systematic [{sigma}] and random [{sigma}]) of the excision area. The required margins were calculated using a margin recipe. Results: The image quality of the cone-beam computed tomography scans was sufficient for localization of the EC. The margins required for the investigated setup correction protocols and the setup errors for the left-right, craniocaudal and anteroposterior directions were 8.3 mm ({sigma} = 3.0, {sigma} = 2.6), 10.6 mm ({sigma} = 3.8, {sigma} = 3.2), and 7.7 mm ({sigma} = 2.7, {sigma} = 2.9) for the no correction strategy; 5.6 mm ({sigma} = 2.0, {sigma} = 1.8), 6.5 mm ({sigma} = 2.3, {sigma} = 2.3), and 4.5 mm ({sigma} = 1.5, {sigma} = 1.9) for the on-line rib strategy; and 5.1 mm ({sigma} = 1.8, {sigma} = 1.7), 4.8 mm ({sigma} = 1.7, {sigma} = 1.6), and 3.3 mm ({sigma} = 1.1, {sigma} = 1.6) for the on-line surface strategy, respectively. Conclusion: Considerable geometric uncertainties in the position of the EC relative to the bony anatomy and breast surface have been observed. By using registration of the breast surface, instead of the rib, the uncertainties in the position of the EC area were reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Uncertainties of Anatomical Sub-Regions in Head-and-Neck Cancer Patients After Offline CBCT Guidance

Purpose: To quantify local geometrical uncertainties in anatomical sub-regions during radiotherapy for head-and-neck cancer patients. Methods and Materials: Local setup accuracy was analyzed for 38 patients, who had received intensity-modulated radiotherapy and were regularly scanned during treatment with cone beam computed tomography (CBCT) for offline patient setup correction. In addition to the clinically used large region of interest (ROI), we defined eight ROIs in the planning CT that contained rigid bony structures: the mandible, larynx, jugular notch, occiput bone, vertebrae C1-C3, C3-C5, and C5-C7, and the vertebrae caudal of C7. By local rigid registration to successive CBCT scans, the local setup accuracy of each ROI was determined and compared with the overall setup error assessed with the large ROI. Deformations were distinguished from rigid body movements by expressing movement relative to a reference ROI (vertebrae C1-C3). Results: The offline patient setup correction protocol using the large ROI resulted in residual systematic errors (1 SD) within 1.2 mm and random errors within 1.5 mm for each direction. Local setup errors were larger, ranging from 1.1 to 3.4 mm (systematic) and 1.3 to 2.5 mm (random). Systematic deformations ranged from 0.4 mm near the reference C1-C3 to 3.8 mm for the larynx. Random deformations ranged from 0.5 to 3.6 mm. Conclusion: Head-and-neck cancer patients show considerable local setup variations, exceeding residual global patient setup uncertainty in an offline correction protocol. Current planning target volume margins may be inadequate to account for these uncertainties. We propose registration of multiple ROIs to drive correction protocols and adaptive radiotherapy to reduce the impact of local setup variations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reproducibility of 'Intelligent' Contouring of Gross Tumor Volume in Non-Small-Cell Lung Cancer on PET/CT Images Using a Standardized Visual Method

Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly used for delineating gross tumor volume (GTV) in non-small-cell lung cancer (NSCLC). The methodology for contouring tumor margins remains controversial. We developed a rigorous visual protocol for contouring GTV that uses all available clinical information and studied its reproducibility in patients from a prospective PET/CT planning trial. Methods and Materials: Planning PET/CT scans from 6 consecutive patients were selected. Six 'observers' (two radiation oncologists, two nuclear medicine physicians, and two radiologists) contoured GTVs for each patient using a predefined protocol and subsequently recontoured 2 patients. For the estimated GTVs and axial distances, least-squares means for each observer and for each case were calculated and compared, using the F test and pairwise t-tests. In five cases, tumor margins were also autocontoured using standardized uptake value (SUV) cutoffs of 2.5 and 3.5 and 40% SUV{sub max}. Results: The magnitude of variation between observers was small relative to the mean (coefficient of variation [CV] = 3%), and the total variation (intraclass correlation coefficient [ICC] = 3%). For estimation of superior/inferior (SI), left/right (LR), and anterior/posterior (AP) borders of the GTV, differences between observers were also small (AP, CV = 2%, ICC = 0.4%; LR, CV = 6%, ICC = 2%; SI, CV 4%, ICC = 2%). GTVs autocontoured generated using SUV 2.5, 3.5, and 40% SUV{sub max} differed widely in each case. An SUV contour of 2.5 was most closely correlated with the mean GTV defined by the human observers. Conclusions: Observer variation contributed little to total variation in the GTV and axial distances. A visual contouring protocol gave reproducible results for contouring GTV in NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Image-Guidance Frequency on Geometric Accuracy and Setup Margins in Radiotherapy for Locally Advanced Lung Cancer

Purpose: To assess the relative effectiveness of five image-guidance (IG) frequencies on reducing patient positioning inaccuracies and setup margins for locally advanced lung cancer patients. Methods and Materials: Daily cone-beam computed tomography data for 100 patients (4,237 scans) were analyzed. Subsequently, four less-than-daily IG protocols were simulated using these data (no IG, first 5-day IG, weekly IG, and alternate-day IG). The frequency and magnitude of residual setup error were determined. The less-than-daily IG protocols were compared against the daily IG, the assumed reference standard. Finally, the population-based setup margins were calculated. Results: With the less-than-daily IG protocols, 20-43% of fractions incurred residual setup errors {>=}5 mm; daily IG reduced this to 6%. With the exception of the first 5-day IG, reductions in systematic error ({Sigma}) occurred as the imaging frequency increased and only daily IG provided notable random error ({sigma}) reductions ({Sigma} = 1.5-2.2 mm, {sigma} = 2.5-3.7 mm; {Sigma} = 1.8-2.6 mm, {sigma} = 2.5-3.7 mm; and {Sigma} = 0.7-1.0 mm, {sigma} = 1.7-2.0 mm for no IG, first 5-day IG, and daily IG, respectively. An overall significant difference in the mean setup error was present between the first 5-day IG and daily IG (p < .0001). The derived setup margins were 5-9 mm for less-than-daily IG and were 3-4 mm with daily IG. Conclusion: Daily cone-beam computed tomography substantially reduced the setup error and could permit setup margin reduction and lead to a reduction in normal tissue toxicity for patients undergoing conventionally fractionated lung radiotherapy. Using first 5-day cone-beam computed tomography was suboptimal for lung patients, given the inability to reduce the random error and the potential for the systematic error to increase throughout the treatment course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Addition of Bevacizumab to Standard Radiation Therapy and Daily Temozolomide Is Associated With Minimal Toxicity in Newly Diagnosed Glioblastoma Multiforme

Purpose: To determine the safety of the addition of bevacizumab to standard radiation therapy and daily temozolomide for newly diagnosed glioblastoma multiforme (GBM). Methods and Materials: A total of 125 patients with newly diagnosed GBM were enrolled in the study, and received standard radiation therapy and daily temozolomide. All patients underwent a craniotomy and were at least 2 weeks postoperative. Radiation therapy was administered in 1.8-Gy fractions, with the clinical target volume for the primary course treated to a dose of 45 to 50.4 Gy, followed by a boost of 9 to 14.4 Gy, to a total dose of 59.4 Gy. Patients received temozolomide at 75 mg/m{sup 2} daily throughout the course of radiation therapy. Bevacizumab was given at 10 mg/kg intravenously every 14 days, beginning a minimum of 4 weeks postoperatively. Results: Of the 125 patients, 120 (96%) completed the protocol-specified radiation therapy. Five patients had to stop the protocol therapy, 2 patients with pulmonary emboli, and 1 patient each with a Grade 2 central nervous system hemorrhage, Grade 4 pancytopenia, and wound dehiscence requiring surgical intervention. All 5 patients ultimately finished the radiation therapy. After radiation therapy, 3 patients had progressive disease, 2 had severe fatigue and decreased performance status, 1 patient had a colonic perforation, and 1 had a rectal fissure; these 7 patients therefore did not proceed with the protocol-specified adjuvant temozolomide, bevacizumab, and irinotecan. However, 113 patients (90%) were able to continue on study. Conclusions: The addition of bevacizumab to standard radiation therapy and daily temozolomide was found to be associated with minimal toxicity in patients newly diagnosed with GBM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase II Study of Intensity Modulated Radiation Therapy to the Pelvis for Postoperative Patients With Endometrial Carcinoma: Radiation Therapy Oncology Group Trial 0418

Purpose: To determine the feasibility of pelvic intensity modulated radiation therapy (IMRT) for patients with endometrial cancer in a multi-institutional setting and to determine whether this treatment is associated with fewer short-term bowel adverse events than standard radiation therapy. Methods: Patients with adenocarcinoma of the endometrium treated with pelvic radiation therapy alone were eligible. Guidelines for target definition and delineation, dose prescription, and dose-volume constraints for the targets and critical normal structures were detailed in the study protocol and a web-based atlas. Results: Fifty-eight patients were accrued by 25 institutions; 43 were eligible for analysis. Forty-two patients (98%) had an acceptable IMRT plan; 1 had an unacceptable variation from the prescribed dose to the nodal planning target volume. The proportions of cases in which doses to critical normal structures exceeded protocol criteria were as follows: bladder, 67%; rectum, 76%; bowel, 17%; and femoral heads, 33%. Twelve patients (28%) developed grade {>=}2 short-term bowel adverse events. Conclusions: Pelvic IMRT for endometrial cancer is feasible across multiple institutions with use of a detailed protocol and centralized quality assurance (QA). For future trials, contouring of vaginal and nodal tissue will need continued monitoring with good QA and better definitions will be needed for organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Bladder Motion in Radiation Therapy Estimated From Pretreatment and Posttreatment Volumetric Imaging

Purpose: The use of image guidance protocols using soft tissue anatomy identification before treatment can reduce interfractional variation. This makes intrafraction clinical target volume (CTV) to planning target volume (PTV) changes more important, including those resulting from intrafraction bladder filling and motion. The purpose of this study was to investigate the required intrafraction margins for soft tissue image guidance from pretreatment and posttreatment volumetric imaging. Methods and Materials: Fifty patients with muscle-invasive bladder cancer (T2-T4) underwent an adaptive radiation therapy protocol using daily pretreatment cone beam computed tomography (CBCT) with weekly posttreatment CBCT. A total of 235 pairs of pretreatment and posttreatment CBCT images were retrospectively contoured by a single radiation oncologist (CBCT-CTV). The maximum bladder displacement was measured according to the patient's bony pelvis movement during treatment, intrafraction bladder filling, and bladder centroid motion. Results: The mean time between pretreatment and posttreatment CBCT was 13 minutes, 52 seconds (range, 7 min 52 sec to 30 min 56 sec). Taking into account patient motion, bladder centroid motion, and bladder filling, the required margins to cover intrafraction changes from pretreatment to posttreatment in the superior, inferior, right, left, anterior, and posterior were 1.25 cm (range, 1.19-1.50 cm), 0.67 cm (range, 0.58-1.12 cm), 0.74 cm (range, 0.59-0.94 cm), 0.73 cm (range, 0.51-1.00 cm), 1.20 cm (range, 0.85-1.32 cm), and 0.86 cm (range, 0.73-0.99), respectively. Small bladders on pretreatment imaging had relatively the largest increase in pretreatment to posttreatment volume. Conclusion: Intrafraction motion of the bladder based on pretreatment and posttreatment bladder imaging can be significant particularly in the anterior and superior directions. Patient motion, bladder centroid motion, and bladder filling all contribute to changes between pretreatment and posttreatment imaging. Asymmetric expansion of CTV to PTV should be considered. Care is required in using image-guided radiation therapy protocols that reduce CTV to PTV margins based only on daily pretreatment soft tissue position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dependence of Coronary 3-Dimensional Dose Maps on Coronary Topologies and Beam Set in Breast Radiation Therapy: A Study Based on CT Angiographies

Purpose: In left-side breast radiation therapy (RT), doses to the left main (LM) and left anterior descending (LAD) coronary arteries are usually assessed after delineation by prior anatomic knowledge on the treatment planning computed tomography (CT) scan. In this study, dose sensitivity due to interindividual coronary topology variation was assessed, and hot spots were located. Methods and Materials: Twenty-two detailed heart models, created from heart computed tomography angiographies, were fitted into a single representative female thorax. Two breast RT protocols were then simulated into a treatment planning system: the first protocol comprised tangential and tumoral bed beams (TGs{sub T}B) at 50 + 16 Gy, the second protocol added internal mammary chain beams at 50 Gy to TGs{sub T}B (TGs{sub T}B{sub I}MC). For the heart, the LAD, and the LM, several dose indicators were calculated: dose-volume histograms, mean dose (D{sub mean}), minimal dose received by the most irradiated 2% of the volume (D{sub 2%}), and 3-dimensional (3D) dose maps. Variations of these indicators with anatomies were studied. Results: For the LM, the intermodel dispersion of D{sub mean} and D{sub 2%} was 10% and 11%, respectively, with TGs{sub T}B and 40% and 80%, respectively, with TGs{sub T}B{sub I}MC. For the LAD, these dispersions were 19% (D{sub mean}) and 49% (D{sub 2%}) with TGs{sub T}B and 35% (D{sub mean}) and 76% (D{sub 2%}) with TGs{sub T}B{sub I}MC. The 3D dose maps revealed that the internal mammary chain beams induced hot spots between 20 and 30 Gy on the LM and the proximal LAD for some coronary topologies. Without IMC beams, hot spots between 5 and 26 Gy are located on the middle and distal LAD. Conclusions: Coronary dose distributions with hot spot location and dose level can change significantly depending on coronary topology, as highlighted by 3D coronary dose maps. In clinical practice, coronary imaging may be required for a relevant coronary dose assessment, especially in cases of internal mammary chain irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Significance of ERBB2 Overexpression in Therapeutic Resistance and Cancer-Specific Survival in Muscle-Invasive Bladder Cancer Patients Treated With Chemoradiation-Based Selective Bladder-Sparing Approach

Purpose: To investigate the associations of ERBB 2 overexpression with chemoradiation therapy (CRT) resistance and cancer-specific survival (CSS) in muscle-invasive bladder cancer (MIBC) patients treated with the CRT-based bladder-sparing protocol. Methods and Materials: From 1997 to 2012, 201 patients with cT2-4aN0M0 bladder cancer were treated with CRT (40 Gy with concurrent cisplatin) following transurethral resection of bladder tumor (TURBT). Basically, patients with tumors that showed good CRT response and were amenable to segmental resection underwent partial cystectomy (PC) with pelvic lymph node dissection for bladder preservation; otherwise, radical cystectomy (RC) was recommended. Included in this study were 119 patients in whom TURBT specimens were available for immunohistochemical analysis of ERBB 2 expression. Following CRT, 30 and 65 patients underwent PC or RC, respectively; the remaining 24 patients did not undergo cystectomy. Tumors were defined as CRT-resistant when patients did not achieve complete response after CRT. Associations of ERBB 2 overexpression with CRT resistance and CSS were evaluated. Results: CRT resistance was observed clinically in 56% (67 of 119 patients) and pathologically (in cystectomy specimens) in 55% (52 of 95 patients). ERBB 2 overexpression was observed in 45 patients (38%). On multivariate analysis, ERBB 2 overexpression was an independent predictor for CRT resistance clinically (odds ratio, 3.6; P=.002) and pathologically (odds ratio, 2.9; P=.031). ERBB 2 overexpression was associated with shorter CSS (5-year CSS rates, 56% vs 87% for the ERBB 2 overexpression group vs the others; P=.001). ERBB 2 overexpression was also an independent risk factor for bladder cancer death at all time points of our bladder-sparing protocol (pre-CRT, post-CRT, and post-cystectomy). Conclusions: ERBB 2 overexpression appears relevant to CRT resistance and unfavorable CSS in MIBC patients treated with the CRT-based bladder-sparing protocol. ERBB 2-targeting treatment may improve the outcomes of such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy Quality Assurance Report From Children's Oncology Group AHOD0031

Purpose: A phase 3 trial assessing response-based therapy in intermediate-risk Hodgkin lymphoma mandated real-time central review of involved field radiation therapy (IFRT) and imaging records by a centralized review center to maximize protocol compliance. We report the impact of centralized radiation therapy review on protocol compliance. Methods and Materials: Review of simulation films, port films, and dosimetry records was required before and after treatment. Records were reviewed by study-affiliated or review center–affiliated radiation oncologists. A deviation of 6% to 10% from protocol-specified dose was scored as “minor”; a deviation of >10% was “major.” A volume deviation was scored as “minor” if margins were less than specified or “major” if fields transected disease-bearing areas. Interventional review and final compliance review scores were assigned to each radiation therapy case and compared. Results: Of 1712 patients enrolled, 1173 underwent IFRT at 256 institutions in 7 countries. An interventional review was performed in 88% of patients and a final review in 98%. Overall, minor and major deviations were found in 12% and 6% of patients, respectively. Among the cases for which ≥1 pre-IFRT modification was requested by the Quality Assurance Review Center and subsequently made by the treating institution, 100% were made compliant on final review. By contrast, among the cases for which ≥1 modification was requested but not made by the treating institution, 10% were deemed compliant on final review. Conclusions: In a large trial with complex treatment pathways and heterogeneous radiation therapy fields, central review was performed in a large percentage of cases before IFRT and identified frequent potential deviations in a timely manner. When suggested modifications were performed by the institutions, deviations were almost eliminated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Nodal Dosing With Registration to the Prostate: Implications for High-Risk Prostate Cancer Patients Receiving Stereotactic Body Radiation Therapy

Purpose: To determine whether image guidance with rigid registration (RR) to intraprostatic markers (IPMs) yields acceptable coverage of the pelvic lymph nodes in the context of a stereotactic body radiation therapy (SBRT) regimen. Methods and Materials: Four to seven kilovoltage cone-beam CTs (CBCTs) from 12 patients with high-risk prostate cancer were analyzed, allowing approximation of an SBRT regimen. The nodal clinical target volume (CTV{sub N}) and bladder were contoured on all kilovoltage CBCTs. The V{sub 100} CTV{sub N}, expressed as a ratio to the same parameter on the initial plan, and the magnitude of translational shift between RR to the IPMs versus RR to the pelvic bones, were computed. The ability of a multimodality bladder filling protocol to minimize bladder height variation was assessed in a separate cohort of 4 patients. Results: Sixty-five CBCTs were assessed. The average V{sub 100} CTV{sub N} was 92.6%, but for a subset of 3 patients the average was 80.0%, compared with 97.8% for the others (P<.0001). The average overall and superior–inferior axis magnitudes of the bony-to-fiducial translations were significantly larger in the subgroup with suboptimal nodal coverage (8.1 vs 3.9 mm and 5.8 vs 2.4 mm, respectively; P<.0001). Relative bladder height changes were also significantly larger in the subgroup with suboptimal nodal coverage (42.9% vs 18.5%; P<.05). Use of a multimodality bladder-filling protocol minimized bladder height variation (P<.001). Conclusion: A majority of patients had acceptable nodal coverage after RR to IPMs, even when approximating SBRT. However, a subset of patients had suboptimal nodal coverage. These patients had large bony-to-fiducial translations and large variations in bladder height. Nodal coverage should be excellent if the superior–inferior axis bony-to-fiducial translation and the relative bladder height change (both easily measured on CBCT) are kept to a minimum. Implementation of a strict bladder filling protocol may achieve this goal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying Unnecessary Normal Tissue Complication Risks due to Suboptimal Planning: A Secondary Study of RTOG 0126

Purpose: The purpose of this study was to quantify the frequency and clinical severity of quality deficiencies in intensity modulated radiation therapy (IMRT) planning in the Radiation Therapy Oncology Group 0126 protocol. Methods and Materials: A total of 219 IMRT patients from the high-dose arm (79.2 Gy) of RTOG 0126 were analyzed. To quantify plan quality, we used established knowledge-based methods for patient-specific dose-volume histogram (DVH) prediction of organs at risk and a Lyman-Kutcher-Burman (LKB) model for grade ≥2 rectal complications to convert DVHs into normal tissue complication probabilities (NTCPs). The LKB model was validated by fitting dose-response parameters relative to observed toxicities. The 90th percentile (22 of 219) of plans with the lowest excess risk (difference between clinical and model-predicted NTCP) were used to create a model for the presumed best practices in the protocol (pDVH{sub 0126,top10%}). Applying the resultant model to the entire sample enabled comparisons between DVHs that patients could have received to DVHs they actually received. Excess risk quantified the clinical impact of suboptimal planning. Accuracy of pDVH predictions was validated by replanning 30 of 219 patients (13.7%), including equal numbers of presumed “high-quality,” “low-quality,” and randomly sampled plans. NTCP-predicted toxicities were compared to adverse events on protocol. Results: Existing models showed that bladder-sparing variations were less prevalent than rectum quality variations and that increased rectal sparing was not correlated with target metrics (dose received by 98% and 2% of the PTV, respectively). Observed toxicities were consistent with current LKB parameters. Converting DVH and pDVH{sub 0126,top10%} to rectal NTCPs, we observed 94 of 219 patients (42.9%) with ≥5% excess risk, 20 of 219 patients (9.1%) with ≥10% excess risk, and 2 of 219 patients (0.9%) with ≥15% excess risk. Replanning demonstrated the predicted NTCP reductions while maintaining the volume of the PTV receiving prescription dose. An equivalent sample of high-quality plans showed fewer toxicities than low-quality plans, 6 of 73 versus 10 of 73 respectively, although these differences were not significant (P=.21) due to insufficient statistical power in this retrospective study. Conclusions: Plan quality deficiencies in RTOG 0126 exposed patients to substantial excess risk for rectal complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter- and Intrafraction Target Motion in Highly Focused Single Vocal Cord Irradiation of T1a Larynx Cancer Patients

Purpose: The purpose of this study was to verify clinical target volume–planning target volume (CTV-PTV) margins in single vocal cord irradiation (SVCI) of T1a larynx tumors and characterize inter- and intrafraction target motion. Methods and Materials: For 42 patients, a single vocal cord was irradiated using intensity modulated radiation therapy at a total dose of 58.1 Gy (16 fractions × 3.63 Gy). A daily cone beam computed tomography (CBCT) scan was performed to online correct the setup of the thyroid cartilage after patient positioning with in-room lasers (interfraction motion correction). To monitor intrafraction motion, CBCT scans were also acquired just after patient repositioning and after dose delivery. A mixed online-offline setup correction protocol (“O2 protocol”) was designed to compensate for both inter- and intrafraction motion. Results: Observed interfraction, systematic (Σ), and random (σ) setup errors in left-right (LR), craniocaudal (CC), and anteroposterior (AP) directions were 0.9, 2.0, and 1.1 mm and 1.0, 1.6, and 1.0 mm, respectively. After correction of these errors, the following intrafraction movements derived from the CBCT acquired after dose delivery were: Σ = 0.4, 1.3, and 0.7 mm, and σ = 0.8, 1.4, and 0.8 mm. More than half of the patients showed a systematic non-zero intrafraction shift in target position, (ie, the mean intrafraction displacement over the treatment fractions was statistically significantly different from zero; P<.05). With the applied CTV-PTV margins (for most patients 3, 5, and 3 mm in LR, CC, and AP directions, respectively), the minimum CTV dose, estimated from the target displacements observed in the last CBCT, was at least 94% of the prescribed dose for all patients and more than 98% for most patients (37 of 42). The proposed O2 protocol could effectively reduce the systematic intrafraction errors observed after dose delivery to almost zero (Σ = 0.1, 0.2, 0.2 mm). Conclusions: With adequate image guidance and CTV-PTV margins in LR, CC, and AP directions of 3, 5, and 3 mm, respectively, excellent target coverage in SVCI could be ensured.

62 RADIOLOGY AND NUCLEAR MEDICINE↗