Search NASA⌕ Search

SEARCH · Search NASA

Results for “reduced set methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Quality Guidelines for Energy System Studies: Capital Cost Scaling Methodology: Revision 4b Report

The National Energy Technology Laboratory (NETL) regularly updates legacy analysis with new studies and cases as the Department of Energy objectives change, technology performance improves, costs are reduced, regulations change, market drivers are established, fuel prices fluctuate, and any number of other relevant factors vary in the market. As legacy studies are updated by NETL, the underlying performance and cost of the cases presented changes, and as such, the methods for interpreting and scaling the cost estimates change. Therefore, it is important that NETL maintain public guidance documents associated with different sets of cost estimates that delineate how a specific set, based on report vintage and/or year published, should be scaled. This Quality Guidelines for Energy System Studies report, providing guidance on capital cost scaling, should generally be applied to NETL case costs included in the report “Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity Revision 4b,” (NETL, 2025) or any cases derived from the cases presented in the referenced report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Use of a Compliant Tether to Decouple Observation Buoy Motion for Auxiliary Wave Power

With the growth of the Blue Economy, the volume of data collection within the ocean environment has been rapidly increasing. Larger numbers of oceanographic, meteorological, and floating Light Detection And Ranging (LiDAR) buoys have been collecting high fidelity measurements while pushing against power budget limits. Power limitations lead to infrequent transmission of reduced data sets or recording data to local storage that must be physically collected when the buoy is serviced. Triton Systems, Inc. and its partners are developing a retrofittable wave energy converter (WEC) to provide auxiliary power to these observation buoys to increase mission duration and power budget, improve reliability, and reduce the need for service trips. One of the greatest challenges has been developing a method to interface Triton's WEC with these buoys without impacting measurement fidelity. This is especially critical for inertial wave and LiDAR wind measurements collected with sensors that could be adversely affected by additional buoy dynamics introduced by an integrated WEC. To address this, Triton and EOM Offshore developed a compliant tether to pair an observation buoy with a floating WEC while decoupling relative motion. Based on EOM's proven stretch hose technology, this compliant tether transmits power and data between the buoy-WEC system. In conclusion, modeling shows that the system has the potential to minimally adversely affect oceanographic, meteorological, wind resource characterization, and other measurements, with future testing scheduled to validate modeling efforts.

16 TIDAL AND WAVE POWER↗

Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE

Graphical operator interface methods have been developed for modular, reconfigurable articulated surface systems in general, and a specific instantiation thereof for JPL's Tri-ATHLETE. The All- Terrain Hex-Limbed Extra-Terrestrial Explorer Robot (ATHLETE) has six limbs with six kinematic degrees of freedom each. The core advancement of this work was the development of a novel set of algorithms for dynamically maintaining a reduced coordinate model of any connected assembly of robot modules.

Norris, Jeffrey S.↗

Stochastic Modelling of Wireless Energy Transfer

This study investigates the efficiency of a new method of powering remote sensors by the means of wireless energy transfer. The increased use of sensors for data collection comes with the inherent cost of supplying power from sources such as power cables or batteries. Wireless energy transfer technology eliminates the need for power cables or periodic battery replacement. The time and cost of setting up or expanding a sensor network will be reduced while allowing sensors to be placed in areas where running power cables or battery replacement is not feasible. This paper models wireless channels for power and data separately. Smart scheduling for the data channel is proposed to avoid transmitting data on a noisy channel where the probability of data loss is high to improve power efficiency. Analytical models have been developed and verified using simulations.

Veilleux, Shaun↗

Data-Driven Computation of Probabilistic Marching Cubes for Efficient Visualization of Level-Set Uncertainty

Uncertainty visualization is an important emerging research area. Being able to visualize data uncertainty can help scientists improve trust in analysis and decision-making. However, visualizing uncertainty can add computational overhead, which can hinder the efficiency of analysis. In this paper, we propose novel data-driven techniques to reduce the computational requirements of the probabilistic marching cubes (PMC) algorithm. PMC is an uncertainty visualization technique that studies how uncertainty in data affects level-set positions. However, the algorithm relies on expensive Monte Carlo (MC) sampling for the multivariate Gaussian uncertainty model because no closed-form solution exists for the integration of multivariate Gaussian. In this work, we propose the eigenvalue decomposition and adaptive probability model techniques that reduce the amount of MC sampling in the original PMC algorithm and hence speed up the computations. Our proposed methods produce results that show negligible differences compared with the original PMC algorithm demonstrated through metrics, including root mean squared error, maximum error, and difference images. We demonstrate the performance and accuracy evaluations of our data-driven methods through experiments on synthetic and real datasets.

Athawale, Tushar↗

An error reduction algorithm to improve lidar turbulence estimates for wind energy

Abstract. Remote-sensing devices such as lidars are currently being investigated as alternatives to cup anemometers on meteorological towers for the measurement of wind speed and direction. Although lidars can measure mean wind speeds at heights spanning an entire turbine rotor disk and can be easily moved from one location to another, they measure different values of turbulence than an instrument on a tower. Current methods for improving lidar turbulence estimates include the use of analytical turbulence models and expensive scanning lidars. While these methods provide accurate results in a research setting, they cannot be easily applied to smaller, vertically profiling lidars in locations where high-resolution sonic anemometer data are not available. Thus, there is clearly a need for a turbulence error reduction model that is simpler and more easily applicable to lidars that are used in the wind energy industry. In this work, a new turbulence error reduction algorithm for lidars is described. The Lidar Turbulence Error Reduction Algorithm, L-TERRA, can be applied using only data from a stand-alone vertically profiling lidar and requires minimal training with meteorological tower data. The basis of L-TERRA is a series of physics-based corrections that are applied to the lidar data to mitigate errors from instrument noise, volume averaging, and variance contamination. These corrections are applied in conjunction with a trained machine-learning model to improve turbulence estimates from a vertically profiling WINDCUBE v2 lidar. The lessons learned from creating the L-TERRA model for a WINDCUBE v2 lidar can also be applied to other lidar devices. L-TERRA was tested on data from two sites in the Southern Plains region of the United States. The physics-based corrections in L-TERRA brought regression line slopes much closer to 1 at both sites and significantly reduced the sensitivity of lidar turbulence errors to atmospheric stability. The accuracy of machine-learning methods in L-TERRA was highly dependent on the input variables and training dataset used, suggesting that machine learning may not be the best technique for reducing lidar turbulence intensity (TI) error. Future work will include the use of a lidar simulator to better understand how different factors affect lidar turbulence error and to determine how these errors can be reduced using information from a stand-alone lidar.

17 WIND ENERGY↗

Development and validation of a quantitative PCR assay method of assessing relative resistance of oat ( Avena sativa ) to crown rust ( Puccinia coronata f. sp. avenae )

Evaluation of oat crown rust resistance is usually based on visual assessment of disease severity or infection types. Visual assessment is subjective, prone to rater bias and requires expert knowledge. PCR‐based quantitative assays can overcome challenges associated with visual assessment. New TaqMan primers and probes were designed from Puccinia coronata f. sp. avenae (Pca) sequences. The primer–probe sets were specific to Pca, amplified using as little as 0.5 pg fungal DNA (fDNA) and allowed for scaling to variation in sample total DNA quantity. The quantitative PCR (qPCR) assay was validated using oat recombinant inbred lines (RILs) from the Provena × 94197A1‐9‐2‐2‐2‐5 cross evaluated under a controlled environment. For comparison with fDNA load, inoculation with the Pca race LCBB provided segregation data on the hypersensitive response, while Pca race LSLG provided data on segregation for reduced pustule number. fDNA content was positively correlated with both pustule number and infection type (IT). Composite interval mapping identified two quantitative trait loci (QTLs) on oat linkage groups Mrg12 and Mrg20 using visual and qPCR assessments (pustule number, IT and fDNA). In this study a qPCR assay method that can be used to assess the relative resistance of oat to crown rust was refined and validated, and single nucleotide polymorphisms (SNPs) closely linked with two QTLs derived from the crown rust resistant line 94197A1‐9‐2‐2‐2‐5 were identified.

Admassu‐Yimer, B.↗

A method for assessing effects of circumferential flow distortion on compressor stability

This paper describes the development of a new analysis to predict the onset of flow instability for an axial compressor operating in a circumferentialy distorted inlet flow. A relatively simple model is used to examine the influence of various distortions in setting this instability point. It is found that the model reproduces known experimental trends for the loss of stability margin with increasing distortion amplitude and with changes in reduced frequency. In particular, there is a recognizable 'critical sector angle' which characterizes loss of stability margin. To the authors' knowledge, this is the first time the effects described herein have been theoretically demonstrated as the direct result of a fluid dynamic stability.

Hynes, T. P.↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

Experimental Setup for Mechanically Testing Subscale Triangular, Rollable, and Collapsible Deployable Composite Booms

High-strain composite deployable space structures are used for space infrastructure and science applications such as solar array supports, antennae, camera masts, and lightweight structures supporting solar sailing propulsion ele-ments. Triangular, Rollable, and Collapsible (TRAC) deployable composite booms are one example of a high-strain composite deployable structure and were studied using novel experimental test and characterization methods developed under the Gravity Offloading and Analysis of Long Imperfection-sensitive Ele-ments (GOALIE) project. In the present work, a subscale 7-m-long TRAC boom was suspended vertically to orient gravity along the length of the boom. By ori-enting vertically, highly nonlinear and unstable behavior often encountered dur-ing horizontally oriented gravity offload testing of similar structures was reduced. Pretest analytical predictions of TRAC booms indicated three unique failure modes, loads, and locations for three unique loading cases of in-plane bending, out-of-plane bending, and axial compression. To investigate the predicted behav-ior, an experimental test was set up to impart mechanical loads to a subscale TRAC boom. The experimental setup, loading cases, and instrumentation used to characterize the mechanical response of a subscale TRAC boom are described in this paper.

High-strain composites↗

A novel IMRT planning study by using the fixed-jaw method in the treatment of peripheral lung cancer with mediastinal lymph node metastasis

Intensity-modulated radiotherapy (IMRT) is an important technology in cancer radiotherapy. In the current planning system, such as in the Pinnacle{sup 3} system, jaw positions are automatically set to cover all target volumes, and many medical centers in developing countries are not equipped with linear accelerators with a jaw tracing function. As solitary lesions are often located in patients, the resulting radiation leakage and transmission increase the dose exposure in surrounding critical organs, although blocked by multileaf collimator (MLC) leaves. We therefore designed a method to manually fix jaw positions, which further reduces doses. We particularly focused on the patients of peripheral lung cancer combined with mediastinal lymph node metastasis, as our medical center mainly targets lung cancer. We designed 2 treatment plans for each patient with the same optimization parameters, i.e., the plan of automatically chosen jaw positions (jaw auto-chosen plan) and the plan of fixed-jaw positions (fixed-jaw plan). In the latter plan, jaws were manually fixed for tumors in lung and in mediastinal lymph node metastases, respectively. We found that both plans met the clinical requirements, and the D{sub 2}, D{sub 98}, conformation number (CN), and homogeneity index (HI) for planning target volume (PTV) had no significant differences between the 2 plans. Importantly, the machine units (MUs) for fixed-jaw plans were 50%~60% more than routine jaw auto-chosen plans, whereas the V{sub 5}, V{sub 10}, V{sub 20}, V{sub 30}, and the mean dose in the total lung and the ipsilateral lung were less than the routine jaw auto-chosen plans. Dose-volume values D{sub 1} for the spinal cord and D{sub 2}, V{sub 40}, V{sub 60} for the heart existed no significant differences for 2 plans. In the fixed-jaw method, the total lung TLV{sub 5}-â–³V{sub ab} and TLV{sub 10}-â–³V{sub ab} values had a moderate positive correlation with the lung radiation leakage and the transmission area reduction. We concluded that the fixed-jaw plan is superior to the routine jaw auto-chosen plan in reducing the radiation exposure of surrounding critical organs, which will benefit the IMRT application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of machine learning for a helium line intensity ratio method in Magnum-PSI

Optical emission spectroscopy (OES) of helium (He) line intensities has been used to measure the electron density, ne, and temperature, Te, in various plasma devices. In this study, a neural network with five hidden layers is introduced to model the relation between the OES data and ne/Te from laser Thomson scattering in the linear plasma device Magnum-PSI and compared to multiple regression analysis. It is shown that the neural network reduces the residual errors of prediction values (ne and Te) less than half those of the multiple regression analysis. We checked two different data splitting methods for training and validation data, i.e., with and without considering the unit of discharge. A comparison of the splitting methods suggests that the residual error will decrease to ~10% even for a new discharge data when accumulating a sufficient data set.

Kajita, Shin↗

Efficient algorithm for locating and sizing series compensation devices in large power transmission grids: I. Model implementation

We explore optimization methods for planning the placement, sizing and operations of Flexible Alternating Current Transmission System (FACTS) devices installed to relieve transmission grid congestion. We limit our selection of FACTS devices to Series Compensation (SC) devices that can be represented by modification of the inductance of transmission lines. Our master optimization problem minimizes the l 1 norm of the inductance modification subject to the usual line thermal-limit constraints. We develop heuristics that reduce this non-convex optimization to a succession of Linear Programs (LP) which are accelerated further using cutting plane methods. The algorithm solves an instance of the MatPower Polish Grid model (3299 lines and 2746 nodes) in 40 seconds per iteration on a standard laptop—a speed up that allows the sizing and placement of a family of SC devices to correct a large set of anticipated congestions. We observe that our algorithm finds feasible solutions that are always sparse, i.e., SC devices are placed on only a few lines. In a companion manuscript, we demonstrate our approach on realistically-sized networks that suffer congestion from a range of causes including generator retirement. In this manuscript, we focus on the development of our approach, investigate its structure on a small test system subject to congestion from uniform load growth, and demonstrate computational efficiency on a realistically-sized network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Three independent one-dimensional margins for single-fraction frameless stereotactic radiosurgery brain cases using CBCT

Purpose: Setting a proper margin is crucial for not only delivering the required radiation dose to a target volume, but also reducing the unnecessary radiation to the adjacent organs at risk. This study investigated the independent one-dimensional symmetric and asymmetric margins between the clinical target volume (CTV) and the planning target volume (PTV) for linac-based single-fraction frameless stereotactic radiosurgery (SRS).Methods: The authors assumed a Dirac delta function for the systematic error of a specific machine and a Gaussian function for the residual setup errors. Margin formulas were then derived in details to arrive at a suitable CTV-to-PTV margin for single-fraction frameless SRS. Such a margin ensured that the CTV would receive the prescribed dose in 95% of the patients. To validate our margin formalism, the authors retrospectively analyzed nine patients who were previously treated with noncoplanar conformal beams. Cone-beam computed tomography (CBCT) was used in the patient setup. The isocenter shifts between the CBCT and linac were measured for a Varian Trilogy linear accelerator for three months. For each plan, the authors shifted the isocenter of the plan in each direction by ±3 mm simultaneously to simulate the worst setup scenario. Subsequently, the asymptotic behavior of the CTV V{sub 80%} for each patient was studied as the setup error approached the CTV-PTV margin.Results: The authors found that the proper margin for single-fraction frameless SRS cases with brain cancer was about 3 mm for the machine investigated in this study. The isocenter shifts between the CBCT and the linac remained almost constant over a period of three months for this specific machine. This confirmed our assumption that the machine systematic error distribution could be approximated as a delta function. This definition is especially relevant to a single-fraction treatment. The prescribed dose coverage for all the patients investigated was 96.1%± 5.5% with an extreme 3-mm setup error in all three directions simultaneously. It was found that the effect of the setup error on dose coverage was tumor location dependent. It mostly affected the tumors located in the posterior part of the brain, resulting in a minimum coverage of approximately 72%. This was entirely due to the unique geometry of the posterior head.Conclusions: Margin expansion formulas were derived for single-fraction frameless SRS such that the CTV would receive the prescribed dose in 95% of the patients treated for brain cancer. The margins defined in this study are machine-specific and account for nonzero mean systematic error. The margin for single-fraction SRS for a group of machines was also derived in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure (LoTToR) v1.0

The low-tilt tomographic reconstruction (LoTToR) method is a post-processing method to correct the missing-wedge artifact, which contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination. Moreover, the software can be used for hospital computer tomography (CT) to reduce the radiation damage to patients without reducing the CT image quality.

Ren, Gang↗

Efficient Algorithm for Locating and Sizing Series Compensation Devices in Large Transmission Grids: Model Implementation (PART 1)

We explore optimization methods for planning the placement, sizing and operations of Flexible Alternating Current Transmission System (FACTS) devices installed to relieve transmission grid congestion. We limit our selection of FACTS devices to Series Compensation (SC) devices that can be represented by modification of the inductance of transmission lines. Our master optimization problem minimizes the l 1 norm of the inductance modification subject to the usual line thermal-limit constraints. We develop heuristics that reduce this non-convex optimization to a succession of Linear Programs (LP) which are accelerated further using cutting plane methods. The algorithm solves an instance of the MatPower Polish Grid model (3299 lines and 2746 nodes) in 40 seconds per iteration on a standard laptop—a speed up that allows the sizing and placement of a family of SC devices to correct a large set of anticipated congestions. We observe that our algorithm finds feasible solutions that are always sparse, i.e., SC devices are placed on only a few lines. In a companion manuscript, we demonstrate our approach on realistically-sized networks that suffer congestion from a range of causes including generator retirement. In this manuscript, we focus on the development of our approach, investigate its structure on a small test system subject to congestion from uniform load growth, and demonstrate computational efficiency on a realistically-sized network.

25 ENERGY STORAGE↗

On the concept of varying influence radii for a successive corrections objective analysis

This paper discusses objective analysis techniques known as 'methods of successive corrections' which were introduced by Cressman (1959) and developed for the analysis of mesoscale weather systems by Barnes (1964 and 1973). Theoretical filter response characteristics of the Barnes method are compared for filter parameters set to retrieve the short wavelengths and then build in the long wavelengths. The accuracy of the method is judged by the ability of the filters to restore desired wavelengths and remove undesired wavelengths. It was found that no single selection of filter parameters for the two-pass Barnes method gives the best analysis for all wavelengths. A three-pass hybrid method is shown to reduce this problem.

Achtemeier, Gary L.↗