Search NASA⌕ Search

SEARCH · Search NASA

Results for “responsive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Descriptive Linear modeling of steady-state visual evoked response

A study is being conducted to explore use of the steady state visual-evoke electrocortical response as an indicator of cognitive task loading. Application of linear descriptive modeling to steady state Visual Evoked Response (VER) data is summarized. Two aspects of linear modeling are reviewed: (1) unwrapping the phase-shift portion of the frequency response, and (2) parsimonious characterization of task-loading effects in terms of changes in model parameters. Model-based phase unwrapping appears to be most reliable in applications, such as manual control, where theoretical models are available. Linear descriptive modeling of the VER has not yet been shown to provide consistent and readily interpretable results.

Levison, W. H.↗

Multi Resolution In-Situ Testing and Multiscale Simulation for Creep Fatigue Damage Analysis of Alloy 617

This report outlines the research activities that were carried out for the integrated experimental and simulation investigation of creep-fatigue damage mechanism and life prediction of Nickel-based alloy, Inconel 617 at high temperatures (950° and 850°). First, a novel experimental design using a hybrid control technique is proposed. The newly developed experimental technique can generate different combinations of creep and fatigue damage by changing the experimental design parameters. Next, detailed imaging analysis and statistical data analysis are performed to quantify the failure mechanisms of the creep fatigue of alloy 617 at high temperatures. It is observed that the creep damage is directly associated with the internal voids at the grain boundaries and the fatigue damage is directly related to the surface cracking. It is also observed that the classical time fraction approach does not has a good correlation with the experimental observed damage features. An effective time fraction parameter is seen to have an excellent correlation with the material microstructural damage. Thus, a new empirical damage interaction diagram is proposed based on the experimental observations. Following this, a macro level viscoplastic model coupled with damage is developed to simulate the stress/strain response under creep fatigue loadings. A damage rate function based on the hysteresis energy and creep energy is proposed to capture the softening behavior of the material and a good correlation with life prediction and material hysteresis behavior is observed. The simulation work is extended to include the microstructural heterogeneity. A crystal plasticity finite element model considering isothermal and large deformation conditions at the microstructural scale has been developed for fatigue, creep-fatigue as well as creep deformation and rupture at high temperature. The model considers collective dislocation glide and climb of the grains and progressive damage accumulation of the grain boundaries. The glide model incorporates a slip resistance evolution model that characterizes the solute-drag creep effects and can capture well the stress-strain and stress time response of fatigue and creep-fatigue tests at various strain ranges and hold times. In order to accurately capture the creep strains that accumulate particularly at relatively low stress levels, a dislocation climb model has been incorporated into the crystal plasticity modeling framework. The dislocation climb model parameters are calibrated and verified through experimental creep tests performed at 950°. In addition, a cohesive zone model has been fully implemented in the context of the crystal plasticity finite element model to capture the intergranular creep damage. The parameters of the cohesive zone model have been calibrated using available experimental data. The numerical simulations illustrate the capability of the proposed model in capturing damage initiation and growth under creep loads as compared to the experimental observations. The microscale analysis sheds light on the crack initiation sites and propagation patterns within the microstructure. The model is also utilized to investigate the hybrid-controlled creep-fatigue tests and has been found to capture reasonably well the stress-strain response with different hold times and hold stress magnitudes.

36 MATERIALS SCIENCE↗

Dynamic power load simulator

Two independent models simulate dynamic and steady-state responses of electrical and electronic equipment under power load. One is resistance/capacitance/inductance network, and the other is variable resistance analog device. Resistance, inductance, and/or capacitance are selected by iterative process; time-domain response is compared with that of real equipment to select optimal values.

Joncas, K. P.↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scattering of impact wave by a crack in composite plate

The surface responses due to impact load on an infinite uniaxial graphite/epoxy plate with and without delamination cracks are investigated both in time and frequency domain by using a hybrid method combining the finite element discretization of the near-field with boundary integral representation of the field outside a contour enclosing completely the crack. This combined method leads to a set of linear unsymmetric complex matrix equations which are solved to obtain the response in the frequency domain by biconjugate gradient method. The time domain response is then obtained by using an FFT. In order to capture the time-domain characteristics accurately, high order finite elements have been used. Also, both the six node singular elements and eight node transition elements are used around the crack tips to model the crack-tip singularity. It is shown that from the numerical results for surface responses both depth and length of this crack can be identified.

Ju, T. H.↗

A Unified Virtual Battery Model for Responsive Assets

We propose a unified virtual battery model for the flexibility of various responsive assets including batteries, thermostatically controllable loads (TCLs), deferrable loads, shiftable loads, and photovoltaics. Such a unified model lays a foundation to apply transactive control to responsive assets for ancillary service provision. We generalize the virtual battery model to shiftable loads and PVs. In the unified model, we select a set of parameters to represent the flexibility of different responsive assets to provide ancillary services related to active power. The set of parameters includes an energy state, an energy upper bound, an energy lower bound, a power upper bound, and a power lower bound. These parameters are selected to be as few as possible to represent the ancillary service provision flexibility of different responsive assets. The meaning of these parameters are explained to those responsive assets. Simulation examples are provided to show the efficacy of the general model to deal with various responsive assets in a unified way.

battery, photovoltaic↗

Antibody Binding Alters the Characteristics and Contents of Extracellular Vesicles Released by Histoplasma capsulatum

ABSTRACT Histoplasma capsulatum produces extracellular vesicles containing virulence-associated molecules capable of modulating host machinery, benefiting the pathogen. Treatment of H. capsulatum cells with monoclonal antibodies (MAbs) can change the outcome of infection in mice. We evaluated the sizes, enzymatic contents, and proteomic profiles of the vesicles released by fungal cells treated with either protective MAb 6B7 (IgG1) or nonprotective MAb 7B6 (IgG2b), both of which bind H. capsulatum heat shock protein 60 (Hsp60). Our results showed that treatment with either MAb was associated with changes in size and vesicle loading. MAb treatments reduced vesicle phosphatase and catalase activities compared to those of vesicles from untreated controls. We identified 1,125 proteins in vesicles, and 250 of these manifested differences in abundance relative to that of proteins in vesicles isolated from yeast cells exposed to Hsp60-binding MAbs, indicating that surface binding of fungal cells by MAbs modified protein loading in the vesicles. The abundance of upregulated proteins in vesicles upon MAb 7B6 treatment was 44.8% of the protein quantities in vesicles from fungal cells treated with MAb 6B7. Analysis of orthologous proteins previously identified in vesicles from other fungi showed that different ascomycete fungi have similar proteins in their extracellular milieu, many of which are associated with virulence. Our results demonstrate that antibody binding can modulate fungal cell responses, resulting in differential loading of vesicles, which could alter fungal cell susceptibility to host defenses. This finding provides additional evidence that antibody binding modulates microbial physiology and suggests a new function for specific immunoglobulins through alterations of fungal secretion. IMPORTANCE Diverse fungal species release extracellular vesicles, indicating that this is a common pathway for the delivery of molecules to the extracellular space. However, there has been no study reporting the impact of antibody binding to the fungal cell on extracellular vesicle release. In the present work, we observed that treatment of H. capsulatum cells with Hsp60-binding MAbs significantly changed the size and cargo of extracellular vesicles, as well as the enzymatic activity of certain virulence factors, such as laccase and phosphatase. Furthermore, this finding demonstrates that antibody binding can directly impact protein loading in vesicles and fungal metabolism. Hence, this work presents a new role for antibodies in the modification of fungal physiology.

59 BASIC BIOLOGICAL SCIENCES↗

Online distributed price-based control of DR resources with competitive guarantees

Demand response (DR) of building HVAC load can provide crucial demand-side flexibility for the future smart grid. Compared to direct load control, price-based control can respect the customers’ autonomy and privacy. However, it is challenging for price-based control to attain provable performance guarantees under future uncertainty. In this paper, we propose a framework for a utility to perform price-based control of flexible building load within the utility’s service area, in order to attain competitive performance guarantees in terms of controlling the system peak demand under future uncertainty. By adopting a two-step approach, our online price-based control solution can attain a provable competitive ratio for all possible realizations within a given uncertainty set. Simulation experiments demonstrate that, with a robustification procedure, our solution can perform well not only for worst-case inputs, but also for average-case inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of dynamic fracture using peridynamics, finite element modeling, and contact.

Peridynamics is a nonlocal extension of classical solid mechanics that allows for the modeling of bodies in which discontinuities occur spontaneously. Because the peridynamic expression for the balance of linear momentum does not contain spatial derivatives and is instead based on an integral equation, it is well suited for modeling phenomena involving spatial discontinuities such as crack formation and fracture. In this study, both peridynamics and classical finite element analysis are applied to simulate material response under dynamic blast loading conditions. A combined approach is utilized in which the portion of the simulation modeled with peridynamics interacts with the finite element portion of the model via a contact algorithm. The peridynamic portion of the analysis utilizes an elastic-plastic constitutive model with linear hardening. The peridynamic interface to the constitutive model is based on the calculation of an approximate deformation gradient, requiring the suppression of possible zero-energy modes. The classical finite element portion of the model utilizes a Johnson-Cook constitutive model. Simulation results are validated by direct comparison to expanding tube experiments. The coupled modeling approach successfully captures material response at the surface of the tube and the emerging fracture pattern. The coupling of peridynamics and finite element analysis via a contact algorithm has been shown to be a viable means for simulating material fracture in a high-velocity impact experiment. A combined peridynamics/finite element approach was applied to model an expanding tube experiment performed by Vogler, et al., in which loading on the tube is a result of Lexan slugs impacting inside the tube. The Lexan portion of the simulation was modeled with finite elements and a Johnson-Cook elastic-plastic material model in conjunction with an equation-of-state law. The steel tube portion of the simulation was modeled with peridynamics, an elastic-plastic material model, and a critical stretch bond damage model. The application of peridynamics to the tube portion of the model allowed the capture of the formation of cracks and eventual fragmentation of the tube. The simulation results yielded good agreement with the experimental results published by Vogler, et al., for the velocity and displacement profiles on the surface of the tube and the resulting fragment distribution. Numerical difficulties were encountered that required removal of hexahedron elements from the Lexan portion of the model over the course of the simulation. The significant number of inverted and nearly-inverted elements appearing over the course of the simulation is believed to be a result of irregularities in the contact between the Lexan and AerMet portions of the model, and was likely exacerbated by the ultra-high strength of the AerMet tube. Future simulations are planned in which the Lexan portion of the simulation is modeled with peridynamics, or with an alternative method such as smoothed particle hydrodynamics, with the goal of reducing these numerical difficulties.

36 MATERIALS SCIENCE↗

Progress in the U.S./Japan PHENIX Project for the Technological Assessment of Plasma Facing Components for DEMO Reactors

The PHENIX Project is a 6-year U.S./Japan bilateral, multi-institutional collaboration program for the Technological Assessment of Plasma Facing Components for DEMO Reactors. The goal is to address the technical feasibility of helium-cooled divertor concepts using tungsten as the armor material in fusion power reactors. The project specifically attempts to (1) improve heat transfer modeling for helium-cooled divertor systems through experiments including steady-state and pulsed high-heat-load testing, (2) understand the thermomechanical properties of tungsten metals and alloys under divertor-relevant neutron irradiation conditions, and (3) determine the behavior of tritium in tungsten materials through high-flux plasma exposure experiments. The High Flux Isotope Reactor and the Plasma Arc Lamp facility at Oak Ridge National Laboratory, the Tritium Plasma Experiment facility at Idaho National Laboratory, and the helium loop at Georgia Institute of Technology are utilized for evaluation of the response to high heat loads and tritium interactions of irradiated and unirradiated materials and components. This paper provides an overview of the progress achieved during the first 3 years and discusses the plan for the remainder of the project.

Kato, Yutai↗

Spent nuclear fuel dynamic performance under normal conditions of transport

The objective of this project is to evaluate the spent nuclear fuel (SNF) vibration integrity under normal condition of transport. The SNF fatigue strength data has been collected from various pressurized water reactors. The CIRFT (Cyclic Integrated Reversible-Bending Fatigue Tester) has been used to simulate transportation environments. CIRFT is an enabling hot-cell testing technology developed at Oak Ridge National Laboratory (ORNL). The CIRFT consists mainly of a U-frame testing setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages to a universal testing machine. The curvature of rod bending is obtained through a three-point deflection measurement method. Three linear variable differential transformers (LVDTs) are used and clamped to the side connecting plates of the U-frame to capture the deformation of the rod. CIRFT results have provided insight into the fuel/clad system response to transportation related loads. Because of the non-homogeneous composite structure of the SNF system, finite element analyses (FEA) are needed to translate the global moment-curvature measurement into local stress-strain profiles. The detailed mechanisms of the pellet-pellet and pellet-clad interactions and the stress concentration effects at the pellet-pellet interface cannot be readily obtained directly from a CIRFT system measurement. Therefore, detailed FEA is used to understand the global test response. The major findings of CIRFT test on the high burn-up SNF are as follows: -) SNF system interface bonding plays an important role in SNF vibration performance; -) Fuel structure contributes to the SNF system stiffness; -) There are significant variations in stress and curvature of SNF systems during vibration cycles resulting from segment pellets and clad interaction, and -) SNF failure initiates at the pellet-pellet interface region and appears to be spontaneous.

42 ENGINEERING↗

Intelligent Facades for High Performance Green Buildings. Final Technical Report

Intelligent Facades for High Performance Green Buildings: Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building- integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring on- site solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high- quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Facades for High Performance Green Buildings

Progress Towards Net-Zero and Net-Positive-Energy Commercial Buildings and Urban Districts Through Intelligent Building Envelope Strategies Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring onsite solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets. With a team that spans multiple stakeholders across disparate industries, from CPV to A&E partners that are responsible for the design and development of District and Regional Scale Urban Development, this project demonstrates that integrating utility-scale high efficiency CPV installations with urban and suburban environments is both viable and desirable within the marketplace. The historical schism between utility scale CPV and BIPV has been one of differing scale and cultures. There is no technical reason why utility-scale CPV cannot be located within urban embedded district scale sites of energy harvesting. New models for leasing large areas of district scale roofs and facades are emerging, such that the model for utility scale energy harvesting can be reconciled to commercial and public scale building sites and campuses. This consortium is designed to unite utility scale solar harvesting into building applications for smart grid development.

14 SOLAR ENERGY↗

Effect of bedrest on thermoregulation.

Attempt to determine what changes occur in the thermoregulatory control system during the simulated weightlessness of prolonged bed rest, as determined by measurement of the onset of sweating in response to an imposed heat load. The threshold for sweating occurred at a lower mean skin temperature and the normal vasodilation response appears to be impaired slightly. It is possible that the result of bed rest is to decrease the circulatory capability of the body (autonomic dysfunction) and the effect on the thermoregulatory system, therefore, is to decrease vasomotor heat loss capability.

Williams, B. A.↗

An Evaluation of an Analytical Simulation of an Airplane with Tailplane Icing by Comparison to Flight Data

This report presents the assessment of an analytical tool developed as part of the NASA/FAA Tailplane Icing Program. The analytical tool is a specialized simulation program called TAILSM4 which was developed to model the effects of tailplane icing on the flight dynamics Twin Otter Icing Research Aircraft. This report compares the responses of the TAILSIM program directly to flight test data. The comparisons should be useful to potential users of TAILSIM. The comparisons show that the TAILSIM program qualitatively duplicates the flight test aircraft response during maneuvers with ice on the tailplane. TAILSIM is shown to be quantitatively "in the ballpark" in predicting when Ice Contaminated Tailplane Stall will occur during pushover and thrust transition maneuvers. As such, TAILSIM proved its usefulness to the flight test program by providing a general indication of the aircraft configuration and flight conditions of concern. The aircraft dynamics are shown to be modeled correctly by the equations of motion used in TAILSIM. However, the general accuracy of the TAILSIM responses is shown to be less than desired primarily due to inaccuracies in the aircraft database. The high sensitivity of the TAILSIM program responses to small changes in load factor command input is also shown to be a factor in the accuracy of the responses. A pilot model is shown to allow TAILSIM to produce more accurate responses and contribute significantly to the usefulness of the program. Suggestions to improve the accuracy of the TAILSIM responses are to further refine the database representation of the aircraft aerodynamics and tailplane flowfield and to explore a more realistic definition of the pilot model.

Hiltner, Dale W.↗

Compressive Failure of Fiber Composites under Multi-Axial Loading

This paper examines the compressive strength of a fiber reinforced lamina under multi-axial stress states. An equilibrium analysis is carried out in which a kinked band of rotated fibers, described by two angles, is sandwiched between two regions in which the fibers are nominally straight. Proportional multi-axial stress states are examined. The analysis includes the possibility of bifurcation from the current equilibrium state. The compressive strength of the lamina is contingent upon either attaining a load maximum in the equilibrium response or satisfaction of a bifurcation condition, whichever occurs first. The results show that for uniaxial loading a non-zero kink band angle beta produces the minimum limit load. For multi-axial loading, different proportional loading paths show regimes of bifurcation dominated and limit load dominated behavior. The present results are able to capture the beneficial effect of transverse compression in raising the composite compressive strength as observed in experiments.

Basu, Shiladitya↗

Methodology for Stress-Controlled Fatigue Test Under In-Air and Pressurized Water Reactor Coolant Water Condition and to Evaluate the Effect of Pressurized Water Reactor Water and Loading Rate on Ratcheting [Methodology for Stress-Controlled Fatigue Test Under In-Air and PWR Coolant Water Condition and to Evaluate the Effect of PWR Water and Loading Rate on Ratcheting]

Here, this work investigates the behavior of 316 stainless steel (SS) under stress-controlled low cycle fatigue loading. Several fatigue experiments are conducted under different environment such as in air at 300°C and primary loop water conditions for a pressurized water reactor (PWR). Two different loading conditions are also employed to examine the effect of stress rate on material hardening and ratcheting. During PWR water test, actuator position measurements are used to determine the strain of the specimen. Under PWR environment, 316 SS is found to ratchet to a significantly greater degree compared with in air. At slow stress rate, higher amount of cyclic hardening is observed in 316 SS, and slow stress rate increases the rate of ratcheting. Results also indicate that 316 SS exhibits asymptotic strain response at higher stress loading which can cause material to behave very differently under same stress cyclic loading.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Examining Uncertainty in Demand Response Baseline Models and Variability in Automated Response to Dynamic Pricing

Controlling electric loads to deliver power system services presents a number of interesting challenges. For example, changes in electricity consumption of Commercial and Industrial (C&I) facilities are usually estimated using counterfactual baseline models, and model uncertainty makes it difficult to precisely quantify control responsiveness. Moreover, C&I facilities exhibit variability in their response. This paper seeks to understand baseline model error and demand-side variability in responses to open-loop control signals (i.e. dynamic prices). Using a regression-based baseline model, we define several Demand Response (DR) parameters, which characterize changes in electricity use on DR days, and then present a method for computing the error associated with DR parameter estimates. In addition to analyzing the magnitude of DR parameter error, we develop a metric to determine how much observed DR parameter variability is attributable to real event-to-event variability versus simply baseline model error. Using data from 38 C&I facilities that participated in an automated DR program in California, we find that DR parameter errors are large. For most facilities, observed DR parameter variability is likely explained by baseline model error, not real DR parameter variability; however, a number of facilities exhibit real DR parameter variability. In some cases, the aggregate population of C&I facilities exhibits real DR parameter variability, resulting in implications for the system operator with respect to both resource planning and system stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗