Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Synthesis, characterization, and hydrogen uptake studies of magnesium nanoparticles by solution reduction method

Graphical abstract: X-ray diffraction (XRD) pattern of magnesium nanoparticles synthesized by solution reduction method with and without TOPO. - Highlights: • Simple and convenient method of preparing Mg nanoparticles. • Characterized by XRD, SEM, FESEM and TEM. • Trioctylphosphine oxide offers a greater control over the size of the particles. • Hydrogen uptake of samples at different temperatures and pressure of 4.5 MPa. - Abstract: Facile and simple, surfactant-mediated solution reduction method was used to synthesize monodisperse magnesium nanoparticles. Little amount of magnesium oxide nanoparticles were also formed due to the presence of TOPO and easy oxidation of magnesium, eventhough, all precautions were taken to avoid oxidation of the sample. Precise size control of particles was achieved by carefully varying the concentration ratio of two different types of surfactants, – trioctylphosphine oxide and hexadecylamine. Recrystallized magnesium nanoparticle samples with and without TOPO were analyzed by X-ray diffraction, scanning electron microscope, field emission scanning electron microscope, and transmission electron microscope. The peak diameters of particles were estimated from size distribution analysis of the morphological data. The particles synthesized in the presence and absence of TOPO found to have diameters 46.5 and 34.8 nm, respectively. This observed dependence of particle size on the presence of TOPO offers a convenient method to control the particle size by simply using appropriate surfactant concentrations. Exceptional enhancement in hydrogen uptake and kinetics in synthesized magnesium nanoparticles as compared to commercial magnesium sample was due to the smaller particle size and improved morphology. Overall hydrogen uptake not affected by the little variation in particle size with and without TOPO.

36 MATERIALS SCIENCE↗

Total Recoverable Aluminum: Not Totally Relevant for Water Quality Standards

Abstract A large water quality data set, representing more than 100 surface-water locations sampled from 2007 to 2017 in the Los Alamos area of New Mexico, USA's Pajarito Plateau, was assembled to evaluate Al concentrations in unfiltered and filtered samples. Aluminum concentrations often exceeded United States Environmental Protection Agency (USEPA) and New Mexico ambient water quality criteria (AWQC), regardless of filter size and sample location. However, AWQC are based on laboratory toxicity studies using soluble Al salts and do not reflect natural conditions in Pajarito Plateau surface waters. The plateau is predominately covered by glassy and recrystallized volcanic ashes (e.g., Bandelier Tuff) containing colloidal to sand-sized aluminosilicates. Samples from natural background drainages and areas downstream of developed regions exhibited similar Al concentrations, suggesting that AWQC exceedances are caused by naturally elevated Al concentrations. Solubility calculations indicated that most samples were oversaturated with respect to amorphous Al(OH)3(s). Therefore, AWQC exceedances are likely artifacts of the “total recoverable” sample preparation, which includes acidification and partial digestion, thereby liberating nonbioavailable Al from aluminosilicates. Accordingly, Al concentrations were strongly associated with suspended sediment concentrations (SSCs), implying that aluminosilicates in suspended sediment contributed to AWQC exceedances and Al oversaturation. Solid-phase particle characterization, using X-ray diffraction (XRD) and scanning electron microscopy with electron dispersive spectroscopy (SEM/EDS) did not identify potentially bioavailable amorphous Al(OH)3(s) in any sample tested. Thus, current sample collection and analysis protocols should not be used to evaluate attainment of Al AWQC on the Pajarito Plateau or locations where aluminosilicates are substantial contributors to total recoverable Al. A sample preparation method (e.g., pH 4 extraction) capable of differentiating nonbioavailable and bioavailable forms of Al is recommended. Otherwise, current New Mexico and USEPA sample preparation approaches will continue to generate artifactual AWQC exceedances in surface waters that contain aluminosilicates. Integr Environ Assess Manag 2019;00:1–14. © 2019 SETAC

Ryan, Adam C.↗

Erbium induced magnetic properties of Er/ZnO nanoparticles

Pure and Er (2, 3 and 4 at. %) doped ZnO nanoparticles have been synthesized by chemical co-precipitation method. EDS spectrum confirmed the presence of Zn, O and Er in the synthesized samples. The XRD measurements confirmed the hexagonal wurtzite structure of ZnO for all samples. The crystallite size of the samples decreases with increase in concentration and are compatible with the results that obtained from TEM analysis.EPR spectra exhibitedferromagnetic signals the substitution Er The possible ferromagnetic zinc interstials signal is appeared for 2 at. % of Er dopant. The room temperature ferromagnetic is observed only for 2 at. % of Er while all other samples exhibiting weak ferromagnetic nature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Radiochemical Separation and Quantification of Tritium in Metallic Radwastes Generated from CANDU Type NPP - 13279

As a destructive quantification method of {sup 3}H in low and intermediate level radwastes, bomb oxidation, sample oxidation, and wet oxidation methods have been introduced. These methods have some merits and demerits in the radiochemical separation of {sup 3}H radionuclides. That is, since the bomb oxidation and sample oxidation methods are techniques using heating at high temperature, the separation methods of the radionuclides are relatively simple. However, since {sup 3}H radionuclide has a property of being diffused deeply into the inside of metals, {sup 3}H which is distributed on the surface of the metals can only be extracted if the methods are applied. As an another separation method, the wet oxidation method makes {sup 3}H oxidized with an acidic solution, and extracted completely to an oxidized HTO compound. However, incomplete oxidized {sup 3}H compounds, which are produced by reactions of acidic solutions and metallic radwastes, can be released into the air. Thus, in this study, a wet oxidation method to extract and quantify the {sup 3}H radionuclide from metallic radwastes was established. In particular, a complete extraction method and complete oxidation method of incomplete chemical compounds of {sup 3}H using a Pt catalyst were studied. The radioactivity of {sup 3}H in metallic radwastes is extracted and measured using a wet oxidation method and liquid scintillation counter. Considering the surface dose rate of the sample, the appropriate size of the sample was determined and weighed, and a mixture of oxidants was added to a 200 ml round flask with 3 tubes. The flask was quickly connected to the distilling apparatus. 20 mL of 16 wt% H{sub 2}SO{sub 4} was given into the 200-ml round flask through a dropping funnel while under stirring and refluxing. After dropping, the temperature of the mixture was raised to 96 deg. C and the sample was leached and oxidized by refluxing for 3 hours. At that time, the incomplete oxidized {sup 3}H compounds were completely oxidized using the Pt catalysts and produced a stable HTO compound. After that, about a 20 ml solution was distilled in the separation apparatus, and the distillate was mixed with an ultimagold LLT as a cocktail solution. The solution in the vial was left standing for at least 24 hours. The radioactivity of {sup 3}H was counted directly using a liquid scintillation analyzer (Packard, 2500 TR/AB, Alpha and Beta Liquid Scintillation Analyzer). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Specimen sizing and remaining life sample calculations for high temperature reactor material surveillance

Advanced high-temperature nuclear reactors rely on structural components that will operate for decades under combined mechanical, thermal, and environmental loading. Materials surveillance programs are a promising strategy for managing the resulting uncertainty in long-term structural integrity by monitoring degradation in service using passively actuated mechanical test articles. Previous reports have developed a simplified, spreadsheetimplementable framework for sizing these test articles and for inferring accumulated creep damage and remaining life from ex-situ test data. This report advances that work toward practical deployment by providing a sample-problem book: a collection of worked, end-toend examples in which the ASME Section III, Division 5 design analysis of a representative high-temperature reactor component is carried through to a sized surveillance article, verified with detailed finite-element analysis, and concluded with a remaining-life assessment based on an assumed ex-situ creep-rate measurement on the retrieved specimen. The report also summarizes ongoing ANL engagement with ASTM Committee E10 on Nuclear Technology and Applications toward drafting a standard covering surveillance procedures for advanced reactors.

Barua, Bipul (ORCID:0000000247184113)↗

Compact Sensitive Piezoelectric Mass Balance for Measurement of Unconsolidated Materials in Space

In many in-situ instruments information about the mass of the sample could aid in the interpretation of the data and portioning instruments might require an accurate sizing of the sample mass before dispensing the sample. In addition, on potential sample return missions a method to directly assess the captured sample size would be required to determine if the sampler could return or needs to continue attempting to acquire sample. In an effort to meet these requirements piezoelectric balances were developed using flextensional actuators which are capable of monitoring the mass using two methods. A piezoelectric balance could be used to measure mass directly by monitoring the voltage developed across the piezoelectric which is linear with force, or it could be used in resonance to produce a frequency change proportional to the mass change. In this case of the latter, the piezoelectric actuator/balance would be swept in frequency through its fundamental resonance. If a mass is added to the balance the resonance frequency would shift down proportionally to the mass. By monitoring the frequency shift the mass could be determined. This design would allow for two independent measurements of the mass. In microgravity environments spacecraft thrusters could be used to provide acceleration in order to produce the required force for the first technique or to bring the mass into contact with the balance in the second approach. In addition, the measuring actuators, if driven at higher voltages, could be used to fluidize the powder to aid sample movement. In this paper, we outline some of our design considerations and present the results of a few prototype balances that we have developed.

resonance↗

Sampling Landsat classifications for crop area estimation

An investigation was conducted to evaluate the effect of several sampling alternatives on the accuracy of crop area estimates made from classification of Landsat Multispectral Scanner (MSS) data. The specific objective was to assess the precision and the bias associated with alternative sampling schemes involving different numbers of several sampling unit sizes. The estimates achieved using the 5 by 6 nm segments were found to have the least precision of any sampling scheme tested. The estimates become more precise as the segment size decreases and more segments are taken. The precision of the 5 by 6 nm segments was significantly less than that of the pixel samples. None of the sampling schemes was significantly biased on the average, and none of the average estimates differed significantly from the population parameter. The maximum absolute deviation, however, was directly related to sampling unit size and should be considered in selection of a sampling unit.

Hixson, M. M.↗

Nanofluidic Size-Exclusion Chromatograph

Efforts are under way to develop a nanofluidic size-exclusion chromatograph (SEC), which would be a compact, robust, lightweight instrument for separating molecules of interest according to their sizes and measuring their relative abundances in small samples. About as large as a deck of playing cards, the nanofluidic SEC would serve, in effect, as a laboratory on a chip that would perform the functions of a much larger, conventional, bench-top SEC and ancillary equipment, while consuming much less power and much smaller quantities of reagent and sample materials. Its compactness and low power demand would render it attractive for field applications in which, typically, it would be used to identify and quantitate a broad range of polar and nonpolar organic compounds in soil, ice, and water samples. Size-exclusion chromatography is a special case of high-performance liquid chromatography. In a conventional SEC, a sample plug is driven by pressure along a column packed with silica or polymer beads that contain uniform nanopores. The interstices between, and the pores in, the beads collectively constitute a size-exclusion network. Molecules follow different paths through the size-exclusion network, such that characteristic elution times can be related to sizes of molecules: basically, smaller molecules reach the downstream end of the column after the larger ones do because the smaller ones enter minor pores and stay there for a while, whereas the larger ones do not enter the pores. The volume accessible to molecules gradually diminishes as their size increases. All molecules bigger than a pore size elute together. For most substances, the elution times and sizes of molecules can be correlated directly with molecular weights. Hence, by measuring the flux of molecules arriving at the downstream end as a function of time, one can obtain a liquid mass spectrum for the molecules present in a sample over a broad range of molecular weights.

Feldman, Sabrina↗

Bootstrapping outperforms community‐weighted approaches for estimating the shapes of phenotypic distributions

Abstract Estimating phenotypic distributions of populations and communities is central to many questions in ecology and evolution. These distributions can be characterized by their moments (mean, variance, skewness and kurtosis) or diversity metrics (e.g. functional richness). Typically, such moments and metrics are calculated using community‐weighted approaches (e.g. abundance‐weighted mean). We propose an alternative bootstrapping approach that allows flexibility in trait sampling and explicit incorporation of intraspecific variation, and show that this approach significantly improves estimation while allowing us to quantify uncertainty. We assess the performance of different approaches for estimating the moments of trait distributions across various sampling scenarios, taxa and datasets by comparing estimates derived from simulated samples with the true values calculated from full datasets. Simulations differ in sampling intensity (individuals per species), sampling biases (abundance, size), trait data source (local vs. global) and estimation method (two types of community‐weighting, two types of bootstrapping). We introduce the traitstrap R package, which contains a modular and extensible set of bootstrapping and weighted‐averaging functions that use community composition and trait data to estimate the moments of community trait distributions with their uncertainty. Importantly, the first function in the workflow, trait_fill , allows the user to specify hierarchical structures (e.g. plot within site, experiment vs. control, species within genus) to assign trait values to each taxon in each community sample. Across all taxa, simulations and metrics, bootstrapping approaches were more accurate and less biased than community‐weighted approaches. With bootstrapping, a sample size of 9 or more measurements per species per trait generally included the true mean within the 95% CI. It reduced average percent errors by 26%–74% relative to community‐weighting. Random sampling across all species outperformed both size‐ and abundance‐biased sampling. Our results suggest randomly sampling ~9 individuals per sampling unit and species, covering all species in the community and analysing the data using nonparametric bootstrapping generally enable reliable inference on trait distributions, including the central moments, of communities. By providing better estimates of community trait distributions, bootstrapping approaches can improve our ability to link traits to both the processes that generate them and their effects on ecosystems.

Maitner, Brian S.↗

Fully Automated Laser Ablation Liquid Capture Sample Analysis using NanoElectrospray Ionization Mass Spectrometry

RATIONALE: Laser ablation provides for the possibility of sampling a large variety of surfaces with high spatial resolution. This type of sampling when employed in conjunction with liquid capture followed by nanoelectrospray ionization provides the opportunity for sensitive and prolonged interrogation of samples by mass spectrometry as well as the ability to analyze surfaces not amenable to direct liquid extraction. METHODS: A fully automated, reflection geometry, laser ablation liquid capture spot sampling system was achieved by incorporating appropriate laser fiber optics and a focusing lens into a commercially available, liquid extraction surface analysis (LESA ) ready Advion TriVersa NanoMate system. RESULTS: Under optimized conditions about 10% of laser ablated material could be captured in a droplet positioned vertically over the ablation region using the NanoMate robot controlled pipette. The sampling spot size area with this laser ablation liquid capture surface analysis (LA/LCSA) mode of operation (typically about 120 m x 160 m) was approximately 50 times smaller than that achievable by direct liquid extraction using LESA (ca. 1 mm diameter liquid extraction spot). The set-up was successfully applied for the analysis of ink on glass and paper as well as the endogenous components in Alstroemeria Yellow King flower petals. In a second mode of operation with a comparable sampling spot size, termed laser ablation/LESA , the laser system was used to drill through, penetrate, or otherwise expose material beneath a solvent resistant surface. Once drilled, LESA was effective in sampling soluble material exposed at that location on the surface. CONCLUSIONS: Incorporating the capability for different laser ablation liquid capture spot sampling modes of operation into a LESA ready Advion TriVersa NanoMate enhanced the spot sampling spatial resolution of this device and broadened the surface types amenable to analysis to include absorbent and solvent resistant materials.

alstroemeria↗

Trajectory sampling and finite-size effects in first-principles stopping power calculations

Abstract Real-time time-dependent density functional theory (TDDFT) is presently the most accurate available method for computing electronic stopping powers from first principles. However, obtaining application-relevant results often involves either costly averages over multiple calculations or ad hoc selection of a representative ion trajectory. We consider a broadly applicable, quantitative metric for evaluating and optimizing trajectories in this context. This methodology enables rigorous analysis of the failure modes of various common trajectory choices in crystalline materials. Although randomly selecting trajectories is common practice in stopping power calculations in solids, we show that nearly 30% of random trajectories in an FCC aluminum crystal will not representatively sample the material over the time and length scales feasibly simulated with TDDFT, and unrepresentative choices incur errors of up to 60%. We also show that finite-size effects depend on ion trajectory via “ouroboros” effects beyond the prevailing plasmon-based interpretation, and we propose a cost-reducing scheme to obtain converged results even when expensive core-electron contributions preclude large supercells. This work helps to mitigate poorly controlled approximations in first-principles stopping power calculations, allowing 1–2 order of magnitude cost reductions for obtaining representatively averaged and converged results.

36 MATERIALS SCIENCE↗

Ultrafast Imaging of Carrier Transport across Grain Boundaries in Hybrid Perovskite Thin Films

For optoelectronic devices based on polycrystalline semiconducting thin films, carrier transport across grain boundaries is an important process in defining efficiency. Here we employ transient absorption microscopy (TAM) to directly measure carrier transport within and across the boundaries in hybrid organic-inorganic perovskite thin films for solar cell applications with 50 nm spatial precision and 300 fs temporal resolution. By selectively imaging sub-bandgap states, our results show that lateral carrier transport is slowed down by these states at the grain boundaries. However, the long carrier lifetimes allow for efficient transport across the grain boundaries. The carrier diffusion constant is reduced by about a factor of 2 for micron-sized grain samples by the grain boundaries. For grain sizes on the order of ~200 nm, carrier transport over multiple grains has been observed within a time window of 5 ns. These observations explain both the shortened photoluminescence lifetimes at the boundaries as well as the seemingly benign nature of the grain boundaries in carrier generation.

14 SOLAR ENERGY↗

Highly Selective Separation of DNA Fragments Using Optically Directed Transport

We present a design that allows selective separation of biomolecules of a particular size without performing complete separation of the sample by size. By focusing a laser beam onto a photoelectrode in contact with an electrolyte medium, a highly localized and optically controlled photoelectrophoretic trap is created. Moving the light beam along the photoelectrode consequently moves the trap. We demonstrate that by manipulating the speed of the photoelectrophoretic trap biomolecules of a particular size can be selectively separated from the mixture. We achieve a qualitative agreement between our experimental results and numerical simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Alpha spectrometric characterization of process-related particle size distributions from active particle sampling at the Los Alamos National Laboratory uranium foundry

Uranium particles within the respirable size range pose a significant hazard to the health and safety of workers. Significant differences in the deposition and incorporation patterns of aerosols within the respirable range can be identified and integrated into sophisticated health physics models. Data characterizing the uranium particle size distribution resulting from specific foundry-related processes are needed. Using personal air sampling cascade impactors, particles collected from several foundry processes were sorted by activity median aerodynamic diameter onto various Marple substrates. After an initial gravimetric assessment of each impactor stage, the substrates were analyzed by alpha spectrometry to determine the uranium content of each stage. Alpha spectrometry provides rapid nondestructive isotopic data that can distinguish process uranium from natural sources and the degree of uranium contribution to the total accumulated particle load. In addition, the particle size bins utilized by the impactors provide adequate resolution to determine if a process particle size distribution is: lognormal, bimodal, or trimodal. Data on process uranium particle size values and distributions facilitate the development of more sophisticated and accurate models for internal dosimetry, resulting in an improved understanding of foundry worker health and safety.

36 MATERIALS SCIENCE↗

Water Migration and Swelling in Engineered Barrier Materials for Radioactive Waste Disposal

Deep, underground repositories are needed to isolate radioactive waste from the biosphere. Because bentonite is an integral component of many multibarrier repository systems, information on the hydraulic behavior of bentonite is crucial for modeling the long-term viability of such systems. In this paper the hydraulic behavior of bentonite samples was analyzed as a function of aggregate size, and samples were subjected to hydrothermal treatments involving contact with NaCl, KCl, and deionized water. Neutron and X-ray imaging were used to quantify water sorption into packed bentonite samples and bentonite swelling into the water column. The distance between the original clay-water interface and the wetting front was determined as a function of time. Average water uptake exhibited a square-root-of-time dependence in freshly prepared samples, but more variable rates were observed for samples previously in contact with water. The radiography was supported by small-angle neutron scattering analysis and ultra-small-angle neutron scattering analysis of aggregate size distributions and by inelastic neutron scattering to understand the physicochemical environment of the sorbed water. Results showed that hydrothermal treatment with KCl had the greatest effect of increased water transport in the bentonite, possibly as a result of the interaction of K + with smectite layers in the clay.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Static Load Model Estimation in Distribution Systems: Preprint

The paper focuses on parameter identification for time varying voltage dependent polynomial load models, namely the constant impedance (Z), constant current (I), and constant power (P), in the distribution systems. Typically, parameter identification has been done for aggregated loads at substations for the transmission planning studies. Given the higher voltage volatility faced by active distribution systems, this paper takes the load model estimation to the distribution networks. The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. Least squares estimation (LSE) method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations of the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system due to varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data, and the use of dynamic simulations to create synthetic measurement data in the absence of real ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗