Search NASA⌕ Search

SEARCH · Search NASA

Results for “source selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Technology Solutions Case Study: Design Guidance for Passive Vents in New Construction, Multifamily Buildings

In an effort to improve indoor air quality in high-performance, new construction, multifamily buildings, dedicated sources of outdoor air are being implemented. Passive vents are being selected by some design teams over other strategies because of their lower first costs and operating costs. The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings constructed eight steps, which outline the design and commissioning required for these passive vents to perform as intended.

building america↗

Nanoparticle deposition in porous and on planar substrates

A method of preparing a metal nanoparticle on a surface includes subjecting a metal source to a temperature and a pressure in a carrier gas selected to provide a vapor metal species at a vapor pressure in the range of about 10−4 to about 10−11 atm; contacting the vapor metal species with a heated substrate; and depositing the metal as a nanoparticle on the substrate.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In-situ resource utilization-derived water purification and hydrogen and oxygen production

This disclosure provides an integrated system and method for producing purified water, hydrogen, and oxygen from contaminated water. The contaminated water may be derived from regolith-based resources on the moon, Mars, near-Earth asteroids, or other destination in outer space. The integrated system and method utilize a cold trap to receive the contaminated water in a vapor phase and selectively freeze out water from one or more volatiles. A heat source increases temperature in the cold trap to vaporize the frozen contaminated water to produce a gas stream of water vapor and volatiles. A chemical scrubber may remove one or more volatiles. The integrated system and method utilize ionomer membrane technology to separate the water vapor from remaining volatiles. The water vapor is delivered for crew use or delivered to an electrolyzer to produce hydrogen and oxygen.

Finger, Barry Wynns↗

Origin and characterization of single-electron events in Skipper-CCDs for light dark matter searches

This manuscript summarizes the work carried out within the SENSEI (Sub-Electron-Noise Skipper-CCD Experimental Instrument) collaboration, an effort focused on the search for light dark matter using Skipper-CCDs. Firstly, it presents the data acquisition and processing protocol developed to establish a selection criteria for events compatible with the dark matter signal. This protocol also enabled the structure and tools used for the study and characterization of phenomena that impact the quality of measurements made in the search for dark matter (measurement of the Fano factor, determination of the Compton background, and characterization of the high-energy surface background), which were carried out during this work. Secondly, it discusses the comprehensive study conducted on the origin of single-electron events in Skipper-CCDs, which allowed for the selection of detector operating parameters and improved the detection sensitivity in the search for dark matter. It is highlighted the characterization of the spatial correlation between single-electron events and high-energy events, among other developed event selection criteria, and the optimization of the output device to reduce sources of luminescence during its operation. As a result of this study, the lowest levels of dark current and spurious charge ever measured in a CCD are reported. Finally, the latest published results from SENSEI are presented. The obtained limits for the scattering of a light mediator are the best reported to date across the entire investigated mass range, while for the heavy mediator, they are the best for masses below 10 MeV. In terms of dark matter absorption, the most restringent limits below 10 eV are reported. These results, achieved with only a very small fraction of the total projected exposure for SENSEI, position Skipper-CCDs as leaders in the search for light dark matter worldwide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo N-Particle Transport Performance of Predicting Digital Radiographic IQI Inspection

The identification of porosity, geometric noncompliance, and other defect types are critical to the qualification of materials and components. X-ray radiographic nondestructive testing is a common industrial inspection method for process quality control and component qualification and certification. Digital radiography provides a quick and efficient alternative when compared to traditional film-based inspection. The quality of radiographic inspection is dependent on equipment specifications, such as the source spot size and detector pixel size, and the specific parameters selected for use for the radiographic technique. To evaluate if an x-ray system and technique is sufficient for a given requirement, a radiographic image quality indicator (IQI) can be used. Radiographic IQIs in hard to machine materials or hard to manufacture defects can be time consuming and expensive to manufacture. This study was conducted to evaluate current Savannah River National Laboratory (SRNL) x-ray imaging systems with a custom tantalum IQI and using Monte Carlo simulations to predict the performance of future systems. The tantalum IQI was tested using a Siefert Isovolt 420 keV x-ray tube with a Perkin Elmer XRD 1611 flat panel with 100-micron pixels. Using the Monte Carlo N-Particle transport software, the radiographic tally was used to simulate the photon flux through an identical tantalum IQI. These simulations provided a benchmark as to the best theoretical identification on a given system using our tantalum IQI. The simulations were refined to match SRNL’s current systems’ noise levels, leading to confidence in their ability to predict the performance of other systems that may be purchased and deployed in the future at the Savannah River Site. Future studies will be conducted to prove this research can be extended to artificially evaluate the ability for systems to identify critical defect sizes through x-ray radiographic inspection, drastically reducing the cost and time burdens of producing high-fidelity radiographic test articles.

digital X-ray radiography↗

Alternative Analysis and Prioritization of Department of Energy “TBD” Materials with No Identified Disposition Pathway

The Department of Energy (DOE) complex manages a significant inventory of excess nuclear materials for which disposition pathways have not been identified, commonly referred to as "To Be Determined" (TBD) items. The Disposition Pathways Program, initiated in FY2018, provides a standardized framework for identifying viable disposition pathways for these materials. In 2023, the program undertook a comprehensive review and systematic analysis of the remaining TBD material groups, updating the assessment from the 2020 TBD Study using the 2022 fiscal year-end Nuclear Material Inventory Assessment (NMIA) as the primary data source. This effort aimed to utilize quantitative analysis to down-select from a wide range of potential disposition options and prioritize the remaining pathways to facilitate informed, risk-based decision-making for future programmatic funding and execution. This paper details the alternative analysis methodology used for screening and prioritization, highlighting the key criteria, ranking process, and resultant recommendations. The study successfully narrowed fifty-two potential disposition options down to nineteen, providing a focused path forward for addressing a longstanding challenge within the DOE complex.

Ramsey, Catherine [Savannah River National Laborat↗

Cost of Capturing CO 2 from Industrial Sources

The objective of this study is to provide an estimate of the cost to capture carbon dioxide (CO 2 ) from select industrial processes (ammonia, ethylene oxide, ethanol, natural gas processing, coal-to-liquids, gas-to-liquids, refinery hydrogen, cement, iron/steel, and pulp/paper). Each of the ten processes were chosen for analysis due to either the high purity of the CO 2 emission source (99–100 mole percent CO 2 ) or the large quantity of CO 2 potentially available. For each industrial process considered, available plant information, such as existing average plant size, projected new development plant size, or existing plant operations data was used to develop a reference plant for this study.

20 FOSSIL-FUELED POWER PLANTS↗

Recovering waste plastics using shape-selective nano-scale reactors as catalysts

We report that waste plastic composed of low-density polyethylene can be converted into a potential new fuel source. This research describes a new nano-scale catalyst with well-defined and uniform surface openings. This material, called Al-SBA-15, is shape-selective, so it uses only one step to generate a gasoline-type product that requires less additional processing compared to that produced by previous catalysts.

36 MATERIALS SCIENCE↗

Radiological Characterization of Selected Thermal Centres Based on Indoor Radon Dosimetry - 17507

In countries with long historical tradition in thermal water therapy and with several mineral-medicinal thermal sources, workplaces within thermal centers may be a source of radon exposure which may be intensified if these are located in regions of high level of natural radiation. According to the EU Directive 96/29/Euratom (repealed by the Directive 2013/59/EURATOM) each Member State shall identify, by means of survey or any other adequate mean, the work activities where a significant increase in the exposure from natural radiation sources may occur, including thermal centers where the exposure to thoron/radon daughters or gamma radiation may occur. The purpose of this work was to perform a radiological characterization of selected thermal centers based on indoor dosimetry. The effective doses received by workers due to radon inhalation were estimated and gamma dose rates were measured through continuous periods. The radon risk for indoor exposure was assessed on a probabilistic basis both on thermal centers and workers' dwellings. Radon levels within the thermal centers ranged from 73 to 4335 Bq/m{sup 3} and the values within the workers dwellings are of the same order of magnitude, 68-4051 Bq/m{sup 3}. Approximately 66 % of indoor radon concentration values are above the maximum EU reference (300 Bq/m{sup 3}) and 94 % of the effective dose is higher than 1 mSv/year. In some situations, radon levels at residential environments are much higher than at workplaces and effective doses are higher than 6 mSv/year, both at residential and work environments. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Low-$p_T$ direct-photon production in Au + Au collisions at $\sqrt{s_{NN}}$ = 39 and 62.4 GeV

Here, the measurement of direct photons from Au + Au collisions at $\sqrt{s_{NN}}$ = 39 and 62.4 GeV in the transverse-momentum range 0.4 < $p_T$ < 3 Gev/c is presented by the PHENIX collaboration at the BNLRelativistic Heavy Ion Collider. A significant direct-photon yield is observed in both collision systems. A universal scaling is observed when the direct-photon $p_T$ spectra for different center-of-mass energies and for different centrality selections at $\sqrt{s_{NN}}$ = 62.4 GeV is scaled with $(dN_{\text{ch}}/dη)^α$ for α = 1.21 ± 0.04. This scaling also holds true for direct-photon spectra from Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV measured earlier by PHENIX, as well as the spectra from Pb + Pb at $\sqrt{s_{NN}}$ = 2760 GeV published by ALICE. The scaling power α seems to be independent of $p_T$, center of mass energy, and collision centrality. The spectra from different collision energies have a similar shape up to $p_T$ of 2 Gev/c. The spectra have a local inverse slope $T_{\text{eff}}$ increasing with $p_T$ of 0.174 ± 0.018 Gev/c in the range 0.4 < $p_T$ < 1.3 Gev/c and increasing to 0.289 ± 0.024 Gev/c for 0.9 < $p_T$ < 2.1 Gev/c. The observed similarity of low-$p_T$ direct-photon production from $\sqrt{s_{NN}}$ = 39 to 2760 GeV suggests a common source of direct photons for the different collision energies and event centrality selections, and suggests a comparable space-time evolution of direct-photon emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

User Guide for the Anvil Threat Cooridor Forecast Tool V2.4 for AWIPS

The Anvil Tool GUI allows users to select a Data Type, toggle the map refresh on/off, place labels, and choose the Profiler Type (source of the KSC 50 MHz profiler data), the Date- Time of the data, the Center of Plot, and the Station (location of the RAOB or 50 MHz profiler). If the Data Type is Models, the user selects a Fcst Hour (forecast hour) instead of Station. There are menus for User Profiles, Circle Label Options, and Frame Label Options. Labels can be placed near the center circle of the plot and/or at a specified distance and direction from the center of the circle (Center of Plot). The default selection for the map refresh is "ON". When the user creates a new Anvil Tool map with Refresh Map "ON, the plot is automatically displayed in the AWIPS frame. If another Anvil Tool map is already displayed and the user does not change the existing map number shown at the bottom of the GUI, the new Anvil Tool map will overwrite the old one. If the user turns the Refresh Map "OFF", the new Anvil Tool map is created but not automatically displayed. The user can still display the Anvil Tool map through the Maps dropdown menu* as shown in Figure 4.

Barett, Joe H., III↗

Power sources for search and rescue 406 MHz beacons

The results of a study directed at the selection of a commercially available, safe, low cost, light weight and long storage life battery for search and rescue (Sarsat) 406 MHz emergency beacons are presented. In the course of this work, five electrochemical systems (lithium-manganese dioxide, lithium-carbon monofluoride, lithium-silver vanadium oxide, alkaline cells, and cadmium-mercuric oxide) were selected for limited experimental studies to determine their suitability for this application. Two safe, commercially available batteries (lithium-manganese dioxide and lithium-carbon monofluoride) which meet the near term requirements and several alternatives for the long term were identified.

Attia, Alan I.↗

Simultaneous Retrieval of Selected Optical Water Quality Indicators From Landsat-8, Sentinel-2, and Sentinel-3

Constructing multi-source satellite-derived water quality (WQ) products in inland and nearshore coastal waters from the past, present, and future missions is a long-standing challenge. Despite inherent differences in sensors’ spectral capability, spatial sampling, and radiometric performance, research efforts focused on formulating, implementing, and validating universal WQ algorithms continue to evolve. This research extends a recently developed machine-learning (ML) model, i.e., Mixture Density Networks (MDNs) (Pahlevan et al., 2020; Smith et al., 2021), to the inverse problem of simultaneously retrieving WQ indicators, including chlorophyll-a (Chla), Total Suspended Solids (TSS), and the absorption by Colored Dissolved Organic Matter at 440 nm (a cdom (440)), across a wide array of aquatic ecosystems. We use a database of in situ measurements to train and optimize MDN models developed for the relevant spectral measurements (400–800 nm) of the Operational Land Imager (OLI), MultiSpectral Instrument (MSI), and Ocean and Land Color Instrument (OLCI) aboard the Landsat-8, Sentinel-2, and Sentinel-3 missions, respectively. Our two performance assessment approaches, namely hold-out and leave-one-out, suggest significant, albeit varying degrees of improvements with respect to second-best algorithms, depending on the sensor and WQ indicator (e.g., 68%, 75%, 117% improvements based on the hold-out method for Chla, TSS, and a cdom (440), respectively from MSI-like spectra). Using these two assessment methods, we provide theoretical upper and lower bounds on model performance when evaluating similar and/or out-of-sample datasets. To evaluate multi-mission product consistency across broad spatial scales, map products are demonstrated for three near-concurrent OLI, MSI, and OLCI acquisitions. Overall, estimated TSS and a cdom (440) from these three missions are consistent within the uncertainty of the model, but Chla maps from MSI and OLCI achieve greater accuracy than those from OLI. By applying two different atmospheric correction processors to OLI and MSI images, we also conduct matchup analyses to quantify the sensitivity of the MDN model and best-practice algorithms to uncertainties in reflectance products. Our model is less or equally sensitive to these uncertainties compared to other algorithms. Recognizing their uncertainties, MDN models can be applied as a global algorithm to enable harmonized retrievals of Chla, TSS, and a cdom (440) in various aquatic ecosystems from multi-source satellite imagery. Local and/or regional ML models tuned with an apt data distribution (e.g., a subset of our dataset) should nevertheless be expected to outperform our global model.

Machine learning↗

SU-E-P-07: Retrospective Analysis of Incident Reports at a Radiology Department: Feedback From Incident Reporting System

Purpose: To provide an overview of reported incidents that occurred in a radiology department and to describe the most common causal source of incidents. Methods: Incident reports from the radiology department at the University of the Ryukyus Hospital between 2008 and 2013 were collected and analyzed retrospectively. The incident report form contains the following items, causal factors of the incident and desirable corrective actions to prevent recurrence of similar incidents. These items allow the institution to investigate/analyze root causes of the incidents and suggest measures to be taken to prevent further, similar incidents. The ‘causal factors of the incident’ item comprises multiple selections from among 24 selections and includes some synonymous selections. In this study, this item was re-categorized into four causal source types: (i) carelessness, (ii) lack of skill or knowledge, (iii) deficiencies in communication, and (iv) external factors. Results: There were a total of 7490 incident reports over the study period and 276 (3.7%) were identified as originating from the radiology department. The most frequent causal source type was carelessness (62%). The other three types showed similar frequencies (10–14%). The staff members involved in incidents indicate three predominant desirable corrective actions to prevent or decrease the recurrence of similar incidents. These are ‘improvement in communication’ (24%), ‘staff training/education’ (19%), and ‘daily medical procedures’ (22%), and the most frequent was ‘improvement in communication’. Even though the most frequent causal factor was related to carelessness, the most desirable corrective action indicated by the staff members was related to communication. Conclusion: Our finding suggests that the most immediate causes are strongly related to carelessness. However, the most likely underlying causes of incidents would be related to deficiencies in effective communication. At our department, therefore, the primary action to prevent/reduce similar incidents should be ‘communication improvement’.

61 RADIATION PROTECTION AND DOSIMETRY↗

Environment-based selection effects of Planck clusters

We investigate whether the large-scale structure environment of galaxy clusters imprints a selection bias on Sunyaev–Zel'dovich (SZ) catalogues. Such a selection effect might be caused by line of sight (LoS) structures that add to the SZ signal or contain point sources that disturb the signal extraction in the SZ survey. We use the Planck PSZ1 union catalogue in the Sloan Digital Sky Survey (SDSS) region as our sample of SZ-selected clusters. We calculate the angular two-point correlation function (2pcf) for physically correlated, foreground and background structure in the RedMaPPer SDSS DR8 catalogue with respect to each cluster. We compare our results with an optically selected comparison cluster sample and with theoretical predictions. In contrast to the hypothesis of no environment-based selection, we find a mean 2pcf for background structures of -0.049 on scales of ≲40 arcmin, significantly non-zero at ~4σ, which means that Planck clusters are more likely to be detected in regions of low background density. We hypothesize this effect arises either from background estimation in the SZ survey or from radio sources in the background. We estimate the defect in SZ signal caused by this effect to be negligibly small, of the order of ~10 -4 of the signal of a typical Planck detection. Analogously, there are no implications on X-ray mass measurements. However, the environmental dependence has important consequences for weak lensing follow up of Planck galaxy clusters: we predict that projection effects account for half of the mass contained within a 15 arcmin radius of Planck galaxy clusters. We did not detect a background underdensity of CMASS LRGs, which also leaves a spatially varying redshift dependence of the Planck SZ selection function as a possible cause for our findings.

79 ASTRONOMY AND ASTROPHYSICS↗

The Sejong Open Cluster Survey (SOS). VII. A Photometric Study of the Young Open Cluster IC 1590

Young open clusters are ideal laboratories to understand the star formation process. We present deep UBVI and Hα photometry for the young open cluster IC 1590 in the center of the H ii region NGC 281. Early-type members are selected from UBV photometric diagrams, and low-mass pre-main-sequence (PMS) members are identified by using Hα photometry. In addition, the published X-ray source list and Gaia astrometric data are also used to isolate probable members. A total of 408 stars are selected as members. The mean reddening obtained from early-type members is &lang;E(B – V)&rang; = 0.40 ± 0.06 (s.d.). We confirm the abnormal extinction law for the intracluster medium. The distance modulus to the cluster determined from the zero-age main-sequence fitting method is 12.3 ± 0.2 mag (d = 2.88 ± 0.28 kpc), which is consistent with the distance d=2.70{sub -0.20}{sup +0.24} kpc from the recent Gaia parallaxes. We also estimate the ages and masses of individual members by means of stellar evolutionary models. The mode of the age of PMS stars is about 0.8 Myr. The initial mass function of IC 1590 is derived. It appears to be a steeper shape (Γ = -1.49 ± 0.14) than that of the Salpeter/Kroupa initial mass function for the high-mass regime (m > 1 M {sub ⊙}). The signature of mass segregation is detected from the difference in the slopes of the initial mass functions for the inner ([[Formula]]) and outer regions of this cluster. We finally discuss the star formation history in NGC 281.

47 OTHER INSTRUMENTATION↗

Supersonic Flight Testing to Assess Ground Recording Systems for NASA's Low Boom Flight Demonstrator

The National Aeronautics and Space Administration (NASA) has performed two supersonic flight test campaigns in preparation for the extensive ground measurements that will be taken during Quesst Phase 2 to verify the low boom from the X-59. The first test campaign was Carpet Determination In Entirety Measurements (CarpetDIEM) Phase II, with F/A-18B aircraft and a subscale ground sensor array and the second campaign was CarpetDIEM Phase III,with both F-15B and F/A-18D aircraft and a geographically large scale ground sensor array. CarpetDIEM Phase II served to evaluate prototypes of the state-of-the-art Ground Recording System (GRS) which NASA is developing in order to record the low boom of X-59. The prototype GRS measured both N-wave and evanescent wave sonic booms which were1.4±1.1PLdB from co-located truth sources during these flights. CarpetDIEM Phase II was also used to down select two NASA developed unattended trigger concepts, one based on Automatic Dependent Surveillance-Broadcast (ADS-B) and the other utilizing satellite communications. Both unattended trigger concepts performed well, with the ADS-B based concept being chosen at the conclusion of CarpetDIEM Phase II for integration with the GRS. CarpetDIEM Phase III was primarily a logistics risk-reduction effort for Quesst Phase 2, but also sought to evaluate the capabilities, including the newly implemented ADS-B unattended trigger, and ruggedness of the GRS during a long-term deployment. The F-15B stood in for the X-59, flying two different X-59flight profiles, including an accelerating climb maneuver. The GRS successfully self-triggered to capture 80% of sonic booms generated from both steady and dynamic flight maneuvers. Low booms, defined by the project as being≤80 PLdB, were recorded by the GRS near the end of CarpetDIEM Phase III. The GRS measured low booms were found to be within0.4±0.1PLdB of a co-located truth source.

Forrest L Carpenter IV↗