Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial orientation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

A Limited-In-Scope Comparison of Subsidence Scenarios For 3D Vadose Zone PORFLOW Trench Models

This technical memorandum summarizes the results from two separate sequences of 3D PORFLOW vadose zone flow and contaminant transport models that were used to test the impact of different spatial distributions of subsidence boundary conditions. More specifically, the two simulation setups used a general conceptual model for an engineered trench (ET): one with a subsided region specified in the center of the trench and one with a subsided region located at the end of the trench. Both subsided regions had the same geometric specifications (e.g., length, width, orientation), but used water infiltration rate boundary conditions that appropriately accounted for surface runoff and lateral drainage from the adjacent upslope intact regions of the final closure cap. Because of the substantially higher water infiltration rate associated with the subsided region at the end of the trench, this geometry produced higher absolute peak fluxes to the water table for all six radionuclides that were simulated. However, the slower release rate of the centrally located subsided hole geometry produced a higher flux to the water table in the time period subsequent to the absolute peak. A third model was implemented as a control, where the water infiltration rate that corresponds to the centrally located subsided region was applied at the end of the trench to highlight the purely geometric effects. The results show that a higher water infiltration rate produces a sharper peak, while a lower infiltration rate leads to a broader peak. A centrally located hole impacts more of the waste zone, producing a higher peak when an equal infiltration rate is applied. These generalized qualitative differences, and their impacts on the overall modeling workflow (i.e., from vadose zone models to limits and dose calculations), should receive appropriate consideration during the development of conceptual models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Goldstone Radar Observations of Horseshoe-orbiting Near-Earth Asteroid 2013 BS45, a Potential Mission Target

We report radar observations of near-Earth asteroid 2013 BS45 obtained during the 2013 apparition. This object is in a resonant, Earth-like orbit, and it is a backup target for NASA’s NEA Scout mission. 2013 BS45 belongs to the Arjuna orbital domain, which currently has ∼20 discovered representatives. These objects tend to be small and difficult to characterize, and 2013 BS45 is only the third Arjuna object observed with radar to date. We observed 2013 BS45 on three days at Goldstone (8560 MHz, 3.5 cm) between 2013 February 10 and 13. The closest approach occurred on February 12 at a distance of 0.0126 au. We obtained relatively weak echo power spectra and ranging data at resolutions up to 0.125 μs (18.75 m px{sup −1}). The Doppler broadening of the echo power spectra strongly suggests an upper bound on the rotation period of 1.9 minutes. The radar data, in combination with an assumption that the asteroid’s radar albedo is no higher than that of metallic NEA 1986 DA, constrain the equivalent diameter to 15 m ≤ D ≤ 38 m. The circular polarization ratio is 0.21 ± 0.06, which implies a near-surface that is relatively smooth on decimeter spatial scales. We bounded the OC radar albedo to η {sub OC} ≥ 0.09 and the optical albedo remains relatively unconstrained at 0.05 ≤ p {sub V} ≤ 0.35. The Yarkovsky acceleration has not been detected but, due to the object’s rapid rotation, would be dominated by a seasonal component whose direction and magnitude depends on the currently unknown pole orientation and thermal inertia.

79 ASTRONOMY AND ASTROPHYSICS↗

MOSFET dosimetry with high spatial resolution in intense synchrotron-generated x-ray microbeams

Various dosimeters have been tested for assessing absorbed doses with microscopic spatial resolution in targets irradiated by high-flux, synchrotron-generated, low-energy ({approx}30-300 keV) x-ray microbeams. A MOSFET detector has been used for this study since its radio sensitive element, which is extraordinarily narrow ({approx}1 {mu}m), suits the main applications of interest, microbeam radiation biology and microbeam radiation therapy (MRT). In MRT, micrometer-wide, centimeter-high, and vertically oriented swaths of tissue are irradiated by arrays of rectangular x-ray microbeams produced by a multislit collimator (MSC). We used MOSFETs to measure the dose distribution, produced by arrays of x-ray microbeams shaped by two different MSCs, in a tissue-equivalent phantom. Doses were measured near the center of the arrays and maximum/minimum (peak/valley) dose ratios (PVDRs) were calculated to determine how variations in heights and in widths of the microbeams influenced this for the therapy, potentially important parameter. Monte Carlo (MC) simulations of the absorbed dose distribution in the phantom were also performed. The results show that when the heights of the irradiated swaths were below those applicable to clinical therapy (<1 mm) the MC simulations produce estimates of PVDRs that are up to a factor of 3 higher than the measured values. For arrays of higher microbeams (i.e., 25 {mu}mx1 cm instead of 25x500 {mu}m{sup 2}), this difference between measured and simulated PVDRs becomes less than 50%. Closer agreement was observed between the measured and simulated PVDRs for the Tecomet MSC (current collimator design) than for the Archer MSC. Sources of discrepancies between measured and simulated doses are discussed, of which the energy dependent response of the MOSFET was shown to be among the most important.

61 RADIATION PROTECTION AND DOSIMETRY↗

Anion Selectivities in Zwitterion Grafted Nanopores: Effect of Zwitterion Architecture

The separation of ions of similar charge is a crucial challenge in many applications, from water treatment to precious metal recovery. Membranes with cross-linked zwitterionic amphiphilic copolymer (ZAC-X) selective layers, which feature self-assembled, zwitterion-lined nanodomains for permeation, offer unique permselectivity between monovalent anions (e.g. $\mathrm{Cl^-}$/$\mathrm{F^-}$). This has motivated studies on the mechanisms of transport and selectivity in this family of materials. In this study, we conducted molecular dynamics simulations of aqueous salt solutions within zwitterion-functionalized nanopores to elucidate the influence of dipole orientation of the ZI ligands on anion diffusivities, partitioning, and permeabilities. Here, our model compares systems with contrasting ZI organization: surface-cation-anion ($\mathrm{S\text{-}ZI^{+}\text{-}ZI^{-}}$, Motif A) and surface-anion-cation ($\mathrm{S\text{-}ZI^{-}\text{-}ZI^{+}}$, Motif B). Our results reveal that Motif A exhibits less pronounced ion pairing due to a spatial separation in the radial profiles of cations and anions. Motif B demonstrates prominent ion pairing for smaller anions owing to their overlap with cation distributions. Further, our potential of mean force profiles reveal that anion partitioning increases with anion size in both ligand motifs, whereas Motif B exhibits significantly higher partitioning selectivity towards larger anions compared to Motif A. Our results for ion diffusivities show that the self-diffusivities of both anions and cations are lower for Motif B compared to Motif A. Such trends in anion partitioning and diffusivities can be explained by differences in the interactions and steric hindrance experienced by the anionic species in Motifs A and B. Finally, our results for anion permselectivity, obtained by combining partitioning and diffusivity, indicate that partitioning trends dominate over diffusivity trends. Consequently, anion permeability increases with anion size, and ligand Motif B yields much higher permselectivity towards larger anions compared to ligand Motif A.

anions↗

Application of Data Cubes for Improving Detection of Water Cycle Extreme Events

As part of an ongoing NASA-funded project to remove a longstanding barrier to accessing NASA data (i.e., accessing archived time-step array data as point-time series), for the hydrology and other point-time series-oriented communities, "data cubes" are created from which time series files (aka "data rods") are generated on-the-fly and made available as Web services from the Goddard Earth Sciences Data and Information Services Center (GES DISC). Data cubes are data as archived rearranged into spatio-temporal matrices, which allow for easy access to the data, both spatially and temporally. A data cube is a specific case of the general optimal strategy of reorganizing data to match the desired means of access. The gain from such reorganization is greater the larger the data set. As a use case of our project, we are leveraging existing software to explore the application of the data cubes concept to machine learning, for the purpose of detecting water cycle extreme events, a specific case of anomaly detection, requiring time series data. We investigate the use of support vector machines (SVM) for anomaly classification. We show an example of detection of water cycle extreme events, using data from the Tropical Rainfall Measuring Mission (TRMM).

water cycle extreme events↗

Investigation of fatigue crack initiation from a non-metallic inclusion via high energy x-ray diffraction microscopy

Crack initiation at inclusions is a dominant, unavoidable and life-limiting failure mechanism of important structural materials. Fatigue progresses in a complex manner to find the ‘weakest link’ in the microstructure, leading to crack nucleation. In this study, fully 3-D characterization methods using high-energy synchrotron x-rays are combined with in-situ mechanical testing to study the crack initiation mechanism in a Ni-based superalloy specimen. The specimen was produced via powder metallurgy and seeded with a non-metallic inclusion. Two x-ray techniques were employed: absorption contrast computed micro-tomography (μ-CT) to determine the morphology of the inclusion and its location in the gauge section of the specimen; and far-field high-energy diffraction microscopy (FF-HEDM) to resolve the centroids, average orientations, and lattice strains of the individual grains comprising the microstructure surrounding the inclusion. Sequential μ-CT and FF-HEDM scans were carried out at both peak and zero applied stress following schedules of cyclic deformation. The µ-CT data showed the onset and location of crack initiation, and the FF-HEDM data provided temporal and spatial evolution of the intergranular strains. Strain partitioning and the associated stress heterogeneities that develop are shown to stabilize within a few loading cycles. Elasto-viscoplastic fast Fourier transform simulations were utilized to supplement interpretation of the experimental stress distributions and compared with the experimental stress distributions. In conclusion, appropriate conditions for crack nucleation in the form of stress gradients were demonstrated and created by virtue of the inclusion, specifically the residual stress state and local bonding state at the inclusion-matrix interface.

36 MATERIALS SCIENCE↗

Engineering of Nanoscale Heterogeneous Transition Metal Dichalcogenide–Au Interfaces

Engineering the transition metal dichalcogenide (TMD)–metal interface is critical for the development of two-dimensional semiconductor devices. By directly probing the electronic structures of WS 2 –Au and WSe 2 –Au interfaces with high spatial resolution, we delineate nanoscale heterogeneities in the composite systems that give rise to local Schottky barrier height modulations. Photoelectron spectroscopy reveals large variations (>100 meV) in TMD work function and binding energies for the occupied electronic states. Characterization of the composite systems with electron backscatter diffraction and scanning tunneling microscopy leads us to attribute these heterogeneities to differing crystallite orientations in the Au contact, suggesting an inherent role of the metal microstructure in contact formation. Here we then leverage our understanding to develop straightforward Au processing techniques to form TMD–Au interfaces with reduced heterogeneity. Our findings illustrate the sensitivity of TMDs’ electronic properties to metal contact microstructure and the viability of tuning the interface through contact engineering.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Three-dimensional patterning of solid microstructures through laser reduction of colloidal graphene oxide in liquid-crystalline dispersions

Graphene materials and structures have become an essential part of modern electronics and photovoltaics. However, despite many production methods, applications of graphene-based structures are hindered by high costs, lack of scalability and limitations in spatial patterning. Here we fabricate three-dimensional functional solid microstructures of reduced graphene oxide in a lyotropic nematic liquid crystal of graphene oxide flakes using a pulsed near-infrared laser. This reliable, scalable approach is mask-free, does not require special chemical reduction agents, and can be implemented at ambient conditions starting from aqueous graphene oxide flakes. Orientational ordering of graphene oxide flakes in self-assembled liquid-crystalline phases enables laser patterning of complex, three-dimensional reduced graphene oxide structures and colloidal particles, such as trefoil knots, with ‘frozen’ orientational order of flakes. These structures and particles are mechanically rigid and range from hundreds of nanometres to millimetres in size, as needed for applications in colloids, electronics, photonics and display technology.

14 SOLAR ENERGY↗

PolLux: A new facility for soft x-ray spectromicroscopy at the Swiss Light Source

We report on the successful installation and operation of a scanning transmission x-ray microspectroscope (STXM) at the PolLux facility at the Swiss Light Source. This integration of an advanced STXM with improved sample handling capabilities and a novel beamline provides unique capabilities. PolLux uses linearly or circularly polarized x-rays from a bending magnet with an extended photon energy range (200-1400 eV). It is therefore well suited to determine a sample's quantitative chemical composition, molecular orientation, or thickness of organic as well as condensed matter materials. The local magnetic state of magnetic thin films is accessible through fast helicity switching by steering the electron beam off axis through the bending magnet. Ex vacuo girder movers allow fast and highly reproducible (<1 {mu}m) alignment of the instrument with respect to the photon beam. The present spatial resolution is {approx}20 nm, limited by the zone plates utilized. The instrument has the stability and positional resolution to operate with much higher resolution optics as it becomes available. In addition to characterization experiments, we present several typical examples from materials research and environmental science to exemplify the capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pyramid image codes

All vision systems, both human and machine, transform the spatial image into a coded representation. Particular codes may be optimized for efficiency or to extract useful image features. Researchers explored image codes based on primary visual cortex in man and other primates. Understanding these codes will advance the art in image coding, autonomous vision, and computational human factors. In cortex, imagery is coded by features that vary in size, orientation, and position. Researchers have devised a mathematical model of this transformation, called the Hexagonal oriented Orthogonal quadrature Pyramid (HOP). In a pyramid code, features are segregated by size into layers, with fewer features in the layers devoted to large features. Pyramid schemes provide scale invariance, and are useful for coarse-to-fine searching and for progressive transmission of images. The HOP Pyramid is novel in three respects: (1) it uses a hexagonal pixel lattice, (2) it uses oriented features, and (3) it accurately models most of the prominent aspects of primary visual cortex. The transform uses seven basic features (kernels), which may be regarded as three oriented edges, three oriented bars, and one non-oriented blob. Application of these kernels to non-overlapping seven-pixel neighborhoods yields six oriented, high-pass pyramid layers, and one low-pass (blob) layer.

Watson, Andrew B.↗

Confidence range estimate of extended source imagery acquisition algorithms via computer simulations

Spatial acquisition using the sun-lit Earth as a beacon source provides several advantages over active beacon-based systems for deep-space optical communication systems. However, since the angular extend of the Earth image is large compared to the laser beam divergence, the acquisition subsystem must be capable of resolving the image to derive the proper pointing orientation. The algorithms used must be capable of deducing the receiver location given the blurring introduced by the imaging optics and the large Earth albedo fluctuation. Furthermore, because of the complexity of modelling the Earth and the tracking algorithms, an accurate estimate of the algorithm accuracy can only be made via simulation using realistic Earth images. An image simulator was constructed for this purpose, and the results of the simulation runs are reported.

Chen, CHIEN-C.↗

The Spatiotemporal Structure of 20th Century Climate Variations in Observations and Reanalyses: Pacific Pan-Decadal Variability - Part 2

The dominant interannual El Nino-Southern Oscillation phenomenon (ENSO) and the short length of climate observation records make it difficult to study long-term climate variations in the spatiotemporal domain. Based on the fact that the ENS0 signal spreads to remote regions and induces delayed climate variation through atmospheric teleconnections, we develop an ENSO-removal method through which the ENS0 signal can be approximately removed at the grid box level from the spatiotemporal field of a climate parameter. After this signal is removed, long-term climate variations, namely, the global warming trend (GW) and the Pacific pan-decadal variability (PDV), are isolated at middle and low latitudes in the climate parameter fields from observed and reanalyses datasets. In this study, we show that one of several PDV interdecadal regime shifts occurred during the 1990s. This significant change in the Pacific basin is comparable but opposite in phase to the 1976 climate regime shift, which results persisting warming in the central-eastern Pacific, and cooling in the North and South Pacific. The 1990s PDV regime shift is consistent with observed changes in ocean biosphere and ocean circulation. A comprehensive picture of PDV as manifested in the troposphere and at the surface is described. In general, the PDV spatial patterns in different parameter fields share some similarities with the patterns associated with ENSO, but important differences exist. First, the PDV atmospheric circulation pattern is shifted westward by about 20deg and its zonal extent is limited to approx.60deg compared to approx.110deg for ENS0 pattern. The westward shift of the PDV wave train produces a different, more west-east oriented, North American teleconnection pattern. The lack of a strong PDV surface temperature (ST) signal in the western equatorial Pacific and the relatively strong ST signal in the subtropical regions are consistent with an atmospheric overturning circulation response that differs from the one associated with ENSO.

Chen, Junye↗

Effect of Multi-Axial Loading on Residual Strain Tensor for 12L14 Steel Alloy

Evaluating the state of residual strain or stress is critically important for structural materials and for reliable design of complex shape components that need to function in extreme environment subjected to large thermo-mechanical loading. When residual stress state is superposed to external loads, it can lead to reduction or increase in failure strength. Past diffraction studies for evaluating the residual strain state involved measuring lattice spacings in three orthogonal directions and do not often correspond to principal directions. To completely resolve the state of strain at a given location, a full strain tensor must be determined. This is especially important when characterizing materials or metallic components exposed to biaxial or complex loading. Neutron diffraction at the second Generation Neutron Residual Stress Facility (NRSF2) at Oak Ridge National Laboratory is used in this study to measure strain tensors associated with different modes of stress path. Hollow cylinder steel samples with 2 mm wall thickness are subjected to either pure axial extension or pure torsion to simulate multi-axial loading conditions. A virgin sample that is not subjected to any deformation, but subjected to identical manufacturing conditions and machining steps involved to obtain hollow cylinder geometry is used for obtaining reference d-spacing for given hkl planes at target spatial location(s). The two samples which are subjected to either pure tension or torsion are loaded to a deformation state that corresponded to equal amount of octahedral shear strain which is an invariant. This procedure is used so that a basis for comparison between the two samples can be made to isolate the stress path effects. A 2-circle Huber orienter is used to obtain strain measurements on identical gauge volume at a series of chi and psi values. The residual state of stress tensor corresponding to ex situ (upon unloading) conditions is presented for three lattice planes (211, 110, 200) for a bcc ferritic system exposed to tension and pure torsion.

HB-2B↗

Single-Crystal-Like, c-axis Oriented BaTiO 3 Thin Films with High-Performance on Flexible Metal Templates for Ferroelectric Applications

Epitaxial, c-axis oriented BaTiO{sub 3} thin films were deposited using pulsed laser ablation on flexible, polycrystalline Ni alloy tape with biaxially textured oxide buffer multilayers. The high quality of epitaxial BaTiO{sub 3} thin films with P4mm group symmetry was confirmed by x-ray diffraction. The microscopic ferroelectric domain structure and the piezoelectric domain switching in these films were confirmed via spatially resolved piezoresponse mapping and local hysteresis loops. Macroscopic measurements demonstrate that the films have well-saturated hysteresis loops with a high remanent polarization of {approx} 11.5 {micro}C/cm{sup 2}. Such high-quality, single-crystal-like BaTiO{sub 3} films on low-cost, polycrystalline, flexible Ni alloy substrates are attractive for applications in flexible lead-free ferroelectric devices.

36 MATERIALS SCIENCE↗

Statistical properties of the population of the Galactic centre filaments – II. The spacing between filaments

ABSTRACT We carry out a population study of magnetized radio filaments in the Galactic centre using MeerKAT data by focusing on the spacing between the filaments that are grouped. The morphology of a sample of 43 groupings containing 174 magnetized radio filaments are presented. Many grouped filaments show harp-like, fragmented cometary tail-like, or loop-like structures in contrast to many straight filaments running mainly perpendicular to the Galactic plane. There are many striking examples of a single filament splitting into two prongs at a junction, suggestive of a flow of plasma along the filaments. Spatial variations in spectral index, brightness, bending, and sharpening along the filaments indicate that they are evolving on a 105−6-yr time-scale. The mean spacings between parallel filaments in a given grouping peaks at ∼16 arcsec. We argue by modeling that the filaments in a grouping all lie on the same plane and that the groupings are isotropically oriented in 3D space. One candidate for the origin of filamentation is interaction with an obstacle, which could be a compact radio source, before a filament splits and bends into multiple filaments. In this picture, the obstacle or sets the length scale of the separation between the filaments. Another possibility is synchrotron cooling instability occurring in cometary tails formed as a result of the interaction of cosmic ray driven Galactic centre outflow with obstacles such as stellar winds. In this picture, the mean spacing and the mean width of the filaments are expected to be a fraction of a parsec, consistent with observed spacing.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy

Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.

60 APPLIED LIFE SCIENCES↗