Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Developmental long trace profiler using optimally aligned mirror based pentaprism

A low-budget surface slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought into operation at the Advanced Light Source Optical Metrology Laboratory. The instrument is based on a precisely calibrated autocollimator and a movable pentaprism. The capability of the DLTP to achieve sub-microradian surface slope metrology has been verified via cross-comparison measurements with other high-performance slope measuring instruments when measuring the same high-quality test optics. In the present work, a further improvement of the DLTP is achieved by replacing the existing bulk pentaprism with a specially designed mirror based pentaprism. A mirror based pentaprism offers the possibility to eliminate systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of a bulk pentaprism. We provide the details of the mirror based pentaprism design and describe an original experimental procedure for precision mutual alignment of the mirrors. The algorithm of the alignment procedure and its efficiency are verified with rigorous ray tracing simulations. Results of measurements of a spherically curved test mirror and a flat test mirror using the original bulk pentaprism are compared with measurements using the new mirror based pentaprism, demonstrating the improved performance.

42 ENGINEERING↗

Superconducting pairing of topological surface states in bismuth selenide films on niobium

A topological insulator film coupled to a simple isotropic s-wave superconductor substrate can foster helical pairing of the Dirac fermions associated with the topological surface states. Experimental realization of such a system is exceedingly difficult, however using a novel “flip-chip” technique, we have prepared single-crystalline Bi 2 Se 3 films with predetermined thicknesses in terms of quintuple layers (QLs) on top of Nb substrates fresh from in situ cleavage. Our angle-resolved photoemission spectroscopy (ARPES) measurements of the film surface disclose superconducting gaps and coherence peaks of similar magnitude for both the topological surface states and bulk states. The ARPES spectral map as a function of temperature and film thickness up to 10 QLs reveals key characteristics relevant to the mechanism of coupling between the topological surface states and the superconducting Nb substrate; the effective coupling length is found to be much larger than the decay length of the topological surface states.

36 MATERIALS SCIENCE↗

Towards the clinical application of laser-induced breakdown spectroscopy for rapid pathogen diagnosis: the effect of mixed cultures and sample dilution on bacterial identification

Laser-induced breakdown spectroscopy has been utilized to classify and identify bacterial specimens on the basis of their atomic composition. We have characterized the effect that the presence of a second bacterial species in the ablated specimen had on the identification of the majority species. Specimens with a reduced number of bacterial cells (approximately 2500) were identified with 100% accuracy when compared to undiluted specimens. In addition, a linear dependence of the total spectral power as a function of cell number was determined. Lastly, a high selectivity was obtained for a LIBS-based analysis of nine separate bacterial strains from four genera.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Biophotonic in situ sensor for plant leaves

Knowledge of the water concentration of plants can be helpful in several environmental and agricultural domains. There are many methods for the determination of water content in plant leaves; however, most of them give a relative moisture level or an analytical measure after a previous calibration procedure. Even for other biochemical compounds such as dry matter or chlorophyll, the measurement techniques could be destructive. For this reason, a nondestructive method has been developed to measure the biochemical compounds of a plant leaf, using an infrared spectroscopy technique. One important advantage is the simplicity of the device (RAdiometre portatif de Mesure In Situ, RAMIS) and its capability to perform measurements in situ. The prototype is a leaf-clip configuration and is made of LEDs at five wavelengths (656, 721, 843, 937, and 1550 nm), and a silicon/germanium photosensor. To compute the water content of vegetative leaves, the radiative transfer model PROSPECT was implemented. This model can accurately predict spectral transmittances in the 400 nm to 2500 nm spectral region as a function of the principal leaf biochemical contents: water, dry matter, and chlorophyll. Using the transmittance measured by RAMIS into an inversion procedure of PROSPECT: A Model of Leaf Optical Properties Spectra, we are able to compute the values of water contents that show an agreement with the water contents measured directly using dry weight procedures. This method is presented as a possibility to estimate other leaf biochemical compounds using appropriate wavelengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Flare Statistics for Young Stars from a Convolutional Neural Network Analysis of TESS Data

All-sky photometric time-series missions have allowed for the monitoring of thousands of young (t age < 800 Myr) stars in order to understand the evolution of stellar activity. In this work, we developed a convolutional neural network (CNN), stella, specifically trained to find flares in Transiting Exoplanet Survey Satellite (TESS) short-cadence data. We applied the network to 3200 young stars in order to evaluate flare rates as a function of age and spectral type. The CNN takes a few seconds to identify flares on a single light curve. We also measured rotation periods for 1500 of our targets and find that flares of all amplitudes are present across all spot phases, suggesting high spot coverage across the entire surface. Additionally, flare rates and amplitudes decrease for stars t age > 50 Myr across all temperatures T eff ≥ 4000 K, while stars from 2300 ≤ T eff < 4000 K show no evolution across 800 Myr. Stars of T eff ≤ 4000 K also show higher flare rates and amplitudes across all ages. We investigate the effects of high flare rates on photoevaporative atmospheric mass loss for young planets. In the presence of flares, planets lose 4%–7% more atmosphere over the first 1 Gyr. stella is an open-source Python toolkit hosted on GitHub and PyPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NGC 4869 in the Coma Cluster: Twist, Wrap, Overlap, and Bend

The upgraded Giant Metrewave Radio Telescope (GMRT) has been used to image the head–tail radio galaxy NGC 4869 in the Coma cluster with an angular resolution of 6.″26 at 250–500 MHz and 2.″18 at the 1050–1450 MHz bands. The archival legacy GMRT data have also been used to image the source with angular resolutions from 4.″9 to 21.″8 at 610 MHz, 325 MHz, 240 MHz, and 150 MHz. We find that the ∼200 kpc scale radio morphology consists of five distinct regions with the clear presence of a pinch at ≈1.′4 (=38.8 kpc) and a ridge at ≈3.′4 (=94.2 kpc) from the head. The sharp bend by ∼70° at ∼3.′5 (=97 kpc) from the head is possibly due to projection effects. The radio spectra show progressive spectral steepening as a function of distance from the head and there is possibly re-acceleration of the synchrotron electrons and perhaps also magnetic field regeneration in the 6″–208″ (=2.8–96.1 kpc) region of the jet. We report a steep spectrum sheath layer enveloping a flat spectrum spine, hinting at a transverse velocity structure with a fast-moving spine surrounded by a slow-moving sheath layer. We also derive the lifetimes of the radiating electrons and equipartition parameters. A plausible explanation for the characteristic feature, a ridge of emission perpendicular to the direction of tail is the flaring of a straight, collimated radio jet as it crosses a surface brightness edge due to Kelvin–Helmholtz instabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Airborne spectrometer senses several gases

Spectrometer's variable shutter permits observation of a wide range of plume widths. Adjustable grating, counter, and access window enable operator to reset grating's position during flight by resetting the counter to a predetermined number. Quartz correlation mask and spectral-aperture instrument-function filter are mounted in a replaceable precision frame.

Mc Dowall, J.↗

Characteristics of cesium iodide for use as a particle discriminator for high energy cosmic rays

The possible use of CsI to discriminate between high energy cosmic ray electrons and interacting protons has been investigated. The pulse-shape properties as a function of ionization density, temperature, and spectral response are presented for thallium-activated CsI and as a function of ionization density for sodium-activated CsI. The results are based on previously published data and on corroborative measurements from the present work. Experimental results on the response of CsI to electron-induced electromagnetic cascades and to interacting hadrons are described. Bibliographies of publications dealing with the properties of CsI and with pulse-shape discrimination techniques are presented.

Crannell, C. J.↗

Nonstationary envelope process and first excursion probability.

The definition of stationary random envelope proposed by Cramer and Leadbetter, is extended to the envelope of nonstationary random process possessing evolutionary power spectral densities. The density function, the joint density function, the moment function, and the crossing rate of a level of the nonstationary envelope process are derived. Based on the envelope statistics, approximate solutions to the first excursion probability of nonstationary random processes are obtained. In particular, applications of the first excursion probability to the earthquake engineering problems are demonstrated in detail.

Yang, J.-N.↗

Scintillation statistics measured in an earth-space-earth retroreflector link

Scintillation was measured in a vertical path from a ground-based laser transmitter to the Geos 3 satellite and back to a ground-based receiver telescope and, the experimental results were compared with analytical results presented in a companion paper (Bufton, 1977). The normalized variance, the probability density function and the power spectral density of scintillation were all measured. Moments of the satellite scintillation data in terms of normalized variance were lower than expected. The power spectrum analysis suggests that there were scintillation components at frequencies higher than the 250 Hz bandwidth available in the experiment.

Bufton, J. L.↗

On the propagation of cosmic rays in the Galaxy

Cosmic ray propagation in the Galaxy is examined within the framework of the leaky-box model, whereby phenomenological aspects of diffusion and propagation are related to the physical properties of the interstellar medium. The model is parameterized by data on composition, spectra, spectral change as a function of energy, and cosmic ray particle lifetime. It is assumed that electrons and nucleons have a common source within the Galaxy (probably associated with supernova remnants). Lifetime data and leakage length are compared with radio synchrotron and gamma-ray data to establish a place of origin for cosmic rays observed at earth, i.e., at a radius of 0.5-1.0 kpc from earth. It is noted that if the escape length becomes energy independent, all nuclear spectra will flatten, while the electron spectrum remains unchanged.

Ormes, J.↗

The International Ultraviolet Explorer spectral image processing system

The International Ultraviolet Explorer spectral image processing system is an on-line interactive system which provides data on the UV spectra of astronomical objects in the wavelength range 1000 to 3200 A. In operation for one year, the image processing system accepts two-dimensional images transmitted digitally from the satellite's SEC vidicon cameras. The system extracts spectral intensity as a function of wavelength and removes background, scattered light, halation and echelle effects.

Klinglesmith, D. A., III↗

A structural model of the adaptive human pilot

A compensatory tracking model of the human pilot is offered which attempts to provide a more realistic representation of the human's signal processing structure than that which is exhibited by pilot models currently in use. Two features of the model distinguish it from other representations of the human pilot. First, proprioceptive information from the control stick or manipulator constitutes one of the major feedback paths in the model, providing feedback of vehicle output rate due to control activity. Implicit in this feedback loop is a model of the vehicle dynamics which is valid in and beyond the region of crossover. Second, error-rate information is continuously derived and independently but intermittently controlled. An output injected remnant model is offered and qualitatively justified on the basis of providing a measure of the effect of inaccuracies such as time variations in the pilot's internal model of the controlled element dynamics. The data from experimental tracking tasks involving five different controlled element dynamics and one nonideal viewing condition were matched with model generated describing functions and remnant power spectral densities.

Hess, R. A.↗