Search NASA⌕ Search

SEARCH · Search NASA

Results for “time synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

General Solution for Theoretical Packet Data Loss Rate

Communications systems which transfer blocks ("frames") of data must use a marker ("frame synchronization pattern") for identifying where a block begins. A technique ("frame synchronization strategy") is used to locate the start of each frame and maintain synchronization as additional blocks are processed. A device which strips out the frame synchronization pattern [FSP] and provides an "end of frame" pulse is called a frame synchronizer. As clock and data errors are introduced into the system, the start-of-block marker becomes displaced and/or corrupted. The capability of the frame synchronizer to stay locked to the pattern under these conditions is a figure of merit for the frame synchronization strategy. It is important to select a strategy which will stay locked nearly all the time at bit error rates where the data is usable. ("Bit error rate" [BER] is the fraction of binary bits which are inverted by passage through a communication system.) The fraction of frames that are discarded because the frame synchronizer is not locked is called "Percent Data Loss" or "Packet Data Loss rate" [PDL]. A general approach for accurately predicting PDL given BER was developed in Theoretical Percent Data Loss Calculation and Measurement Accuracy, T. P. Kelly, LESC-30554, December 1992. Kelly gave a solution in terms of matrix equations, and only addressed "level" channel encoding. This paper goes on to give a closed-form polynomial solution for the most common class of frame synchronizer strategies, and will also address "mark" and "space" (differential) channel encoding, and burst error environments. The paper is divided into four sections and follows a logically ordered presentation, with results developed before they are evaluated. However, most readers will derive the greatest benefit from this paper by treating the results as reference material. The result developed for differential encoding can be extended to other applications (like block codes) where the probability is needed that a block contains only a certain number of errors.

Lansdowne, Chatwin↗

Communications satellites in non-geostationary orbits

The design of a satellite communications system in an orbit lower than GEO is described. Two sun-synchronous orbits which lie in the equatorial plane have been selected: (1) the apogee at constant time-of-day equatorial orbit, a highly eccentric orbit with five revolutions per day, which allows 77-135 percent more satellite mass to be placed in orbit than for GEO; and (2) the sun-synchronous 12-hour equatorial orbit, a circular orbit with two revolutions per day, which allows 23-29 percent more mass. The results of a life cycle economic analysis illustrate that nongeostationary satellite systems could be competitive with geostationary satellite systems.

Price, Kent M.↗

Efficiency/reliability design requirements at low output voltage levels.

Higher efficiency and reliability are needed in the rectification used to produce low output voltages. To this end, the application of driven synchronous rectifier circuits is investigated. One reliability problem of such circuits, the ?double-on' resulting from storage time, is illustrated for low output voltages obtained from rectification of the square-wave outputs of low input voltage converters. A comparison of the rectification efficiency and reliability of driven transistor synchronous rectifiers with that of barrier diodes indicates that the choice of rectifiers in low output voltage applications is dependent on both the source and output voltage levels of the application.

Pasciutti, E. R.↗

A study of magnetosphere dynamics during auroral electrojet events by observations of energetic electron intensity changes at synchronous orbit

The central theme of the considered investigation is the surprising detailed correlation between dynamical changes in electron directional intensity measurements at synchronous orbit and the auroral electrojet currents in the polar ionosphere. The statistical study reported has been carried out following the discovery by Erickson and Winckler (1973) of a close relationship between the time profiles of auroral electrojet intensifications and electron intensity decreases observed in the pre-midnight sector at synchronous orbit. The electron data used in the study were obtained during 1967 and 1968 by the University of Minnesota magnetic spectrometer carried onboard ATSl.

Erickson, K. N.↗

Curling probe measurement of electron density in pulse-modulated plasma

The electron density n{sub e} of stationary plasma can be easily obtained on the basis of the resonance frequency f of a curling probe (CP) measured by a network analyzer (NWA). However, in pulsed plasma with discharge period T, the n{sub e} and f values periodically change with time. This study extends the conventional CP technique to a time-resolved measurement of the pulse-modulated electron density. The condition necessary for the measurement is revealed to be synchronization of NWA with the pulse modulation, which is expressed as (n − 1)T/T{sub SWP} = integer (1, 2, …) for a number n of data point and sweep time T{sub SWP}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress in Interferometric Rayleigh Scattering to Measure Fluctuations Spectra of Velocity and Temperature in High Speed Flows

A new, spectrally-resolved, Rayleigh scattering setup at NASA Ames is further developed to measure fluctuations in velocity and temperature. Using a combination of a continuous-wave laser, a stabilized Fabry-Perot interferometer (FPI), an EMCCD camera, and a photo-multiplier tube, the setup was demonstrated to provide fairly accurate measurements of time-averaged velocity, temperature, density and spectrum of density fluctuations in a high-speed free jet (Panda & White, 2018). This paper describes further progress in fast measurement of the Rayleigh-Brillouin spectrum via a 16-anode linear-array of photo-multiplier tube and a multi-channel, photo-electron counter. Rayleigh scattered light from a 0.4mm long probe volume was directly imaged through the FPI and was imaged on the linear array. Synchronous photo-electron counting over a series of short, contiguous gates provided time-evolution of the fringes at a 10 kHz sampling rate. Sample spectra collected from a Mach 0.98 jet show spectral content floating on high noise-floor. Efforts to collect longer time series of data and different schemes of extracting velocity and temperature information are now in progress.

Panda, J.↗

High-speed X-ray phase tomography with Talbot interferometer and fringe scanning method

High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform method to improve spatial resolution without a considerable increase of scan time. To apply fringe-scanning method to high speed tomography, we tested a scan that is a synchronous combination of one-way continuous movements of the sample rotation and the grating displacement. When this scanning method was combined with X-ray phase tomography, we were able to obtain a scan time of 5 s. A comparison of the image quality derived with the conventional approach and with the proposed approach using the fringe-scanning method showed that the latter had better spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stereoscopic Planar Laser-Induced Fluorescence Imaging at 500 kHz

A new measurement technique for obtaining time- and spatially-resolved image sequences in hypersonic flows is developed. Nitric-oxide planar laser-induced fluorescence (NO PLIF) has previously been used to investigate transition from laminar to turbulent flow in hypersonic boundary layers using both planar and volumetric imaging capabilities. Low flow rates of NO were typically seeded into the flow, minimally perturbing the flow. The volumetric imaging was performed at a measurement rate of 10 Hz using a thick planar laser sheet that excited NO fluorescence. The fluorescence was captured by a pair of cameras having slightly different views of the flow. Subsequent stereoscopic reconstruction of these images allowed the three-dimensional flow structures to be viewed. In the current paper, this approach has been extended to 50,000 times higher repetition rates. A laser operating at 500 kHz excites the seeded NO molecules, and a camera, synchronized with the laser and fitted with a beam-splitting assembly, acquires two separate images of the flow. The resulting stereoscopic images provide three-dimensional flow visualizations at 500 kHz for the first time. The 200 ns exposure time in each frame is fast enough to freeze the flow while the 500 kHz repetition rate is fast enough to time-resolve changes in the flow being studied. This method is applied to visualize the evolving hypersonic flow structures that propagate downstream of a discrete protuberance attached to a flat plate. The technique was demonstrated in the NASA Langley Research Center s 31-Inch Mach 10 Air Tunnel facility. Different tunnel Reynolds number conditions, NO flow rates and two different cylindrical protuberance heights were investigated. The location of the onset of flow unsteadiness, an indicator of transition, was observed to move downstream during the tunnel runs, coinciding with an increase in the model temperature.

Medford, Taylor L.↗

Synchronizing the consistency relation

We study the N-point function of the density contrast to quadratic order in the squeezed limit during the matter-dominated (MD) and radiation-dominated (RD) eras in synchronous gauge. Since synchronous gauge follows the free-fall frame of observers, the equivalence principle dictates that in the gradient approximation for the long-wavelength mode there is only a single, manifestly time-independent consistency relation for the N-point function. This simple form is dictated by the initial mapping between synchronous and local coordinates, unlike Newtonian gauge and its correspondingly separate dilation and Newtonian consistency relations. Dynamical effects only appear at quadratic order in the squeezed limit and are again characterized by a change in the local background, also known as the separate universe approach. We show that for the 3-point function the compatibility between these squeezed-limit relations and second-order perturbation theory requires both the initial and dynamical contributions to match, as they do in single-field inflation. This clarifies the role of evolution or late-time projection effects in establishing the consistency relation for observable bispectra, which is especially important for radiation acoustic oscillations and for establishing consistency below the matter-radiation equality scale in the MD era. Defining an appropriate angle and time average of these oscillations is also important for making separate universe predictions of spatially varying local observables during the RD era, which can be useful for a wider range of cosmological predictions beyond N-point functions.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-EF-BRA-06: A Novel Retrospective 3D K-Space Sorting 4D-MRI Technique Using a Radial K-Space Acquisition MRI Sequence

Purpose: Current retrospective 4D-MRI provides superior tumor-to-tissue contrast and accurate respiratory motion information for radiotherapy motion management. The developed 4D-MRI techniques based on 2D-MRI image sorting require a high frame-rate of the MR sequences. However, several MRI sequences provide excellent image quality but have low frame-rate. This study aims at developing a novel retrospective 3D k-space sorting 4D-MRI technique using radial k-space acquisition MRI sequences to improve 4D-MRI image quality and temporal-resolution for imaging irregular organ/tumor respiratory motion. Methods: The method is based on a RF-spoiled, steady-state, gradient-recalled sequence with minimal echo time. A 3D radial k-space data acquisition trajectory was used for sampling the datasets. Each radial spoke readout data line starts from the 3D center of Field-of-View. Respiratory signal can be extracted from the k-space center data point of each spoke. The spoke data was sorted based on its self-synchronized respiratory signal using phase sorting. Subsequently, 3D reconstruction was conducted to generate the time-resolved 4D-MRI images. As a feasibility study, this technique was implemented on a digital human phantom XCAT. The respiratory motion was controlled by an irregular motion profile. To validate using k-space center data as a respiratory surrogate, we compared it with the XCAT input controlling breathing profile. Tumor motion trajectories measured on reconstructed 4D-MRI were compared to the average input trajectory. The mean absolute amplitude difference (D) was calculated. Results: The signal extracted from k-space center data matches well with the input controlling respiratory profile of XCAT. The relative amplitude error was 8.6% and the relative phase error was 3.5%. XCAT 4D-MRI demonstrated a clear motion pattern with little serrated artifacts. D of tumor trajectories was 0.21mm, 0.23mm and 0.23mm in SI, AP and ML directions, respectively. Conclusion: A novel retrospective 3D k-space sorting 4D-MRI technique has been developed and evaluated on human digital phantom. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

Optical communication with semiconductor laser diodes

Slot timing recovery in a direct detection optical PPM communication system can be achieved by processing the photodetector waveform with a nonlinear device whose output forms the input to a phase lock group. The choice of a simple transition detector as the nonlinearity is shown to give satisfactory synchronization performance. The rms phase error of the recovered slot clock and the effect of slot timing jitter on the bit error probability were directly measured. The experimental system consisted of an AlGaAs laser diode (lambda = 834 nm) and a silicon avalanche photodiode (APD) photodetector and used Q=4 PPM signaling operated at a source data rate of 25 megabits/second. The mathematical model developed to characterize system performance is shown to be in good agreement with actual performance measurements. The use of the recovered slot clock in the receiver resulted in no degradation in receiver sensitivity compared to a system with perfect slot timing. The system achieved a bit error probability of 10 to the minus 6 power at received signal energies corresponding to an average of less than 60 detected photons per information bit.

Davidson, F.↗

Study of beam synchronization at JLEIC

The ion collider ring of Jefferson Labs Electron-Ion Collider (JLEIC) accommodates a wide range of ion energies, from 20 to 100 GeV for protons or from 8 to 40 GeV per nucleon for lead ions. In this medium energy range, ions are not fully relativistic, which means values of their relativistic beta are slightly below 1, leading to an energy dependence of revolution time of the collider ring. On the other hand, electrons with energy 3 GeV and above are already ultra-relativistic such that their speeds are effectively equal to the speed of light. The difference in speeds of colliding electrons and ions in JLEIC, when translated into a path-length difference necessary to maintain the same timing between electron and ion bunches, is quite large. In this paper, we explore schemes for synchronizing the electron and ion bunches at a collision point as the ion energy is varied.

Morozov, Vasiliy↗

A Method for Dynamic Kolsky Bar Compression at High Temperatures: Application to Ti-6Al-4V

Abstract An experimental apparatus for measuring the dynamic behavior of materials subjected to strain rates on the order of 10 $$^3$$ 3 s $$^{-1}$$ - 1 and temperatures up to 800°C with a unique triple actuation system is developed in this work. This system is based on the traditional Kolsky (or split-Hopkinson pressure) bar design, with the addition of an external furnace used to heat the specimen to the desired temperature. A synchronized triple pneumatic actuation system is used to control the motion and timing of the the sample, incident, and transmitted bars. The cold contact time (CCT), or the time during which the heated sample is in contact with the room temperature bars before compression, is measured experimentally and carefully controlled to minimize the development of a temperature gradient across the sample and avoid heating of the bars. Experiments are performed in conjunction with ultra high speed imaging and 2D digital image correlation (DIC), as well as high speed thermal imaging. To verify the viability of the proposed system, experiments were conducted on Ti-6Al-4V (wt.%) at temperatures from 25°C up to and 800°C at an average strain rate of approximately 1200 s $$^{-1}$$ - 1 .

36 MATERIALS SCIENCE↗

Landau damping in a turbulent setting

To address the problem of Landau damping in kinetic turbulence, we consider the forcing of the linearized Vlasov equation by a stationary random source. It is found that the time-asymptotic density response is dominated by resonant particle interactions that are synchronized with the source. The energy consumption of this response is calculated, implying an effective damping rate, which is the main result of this paper. Evaluating several cases, it is found that the effective damping rate can differ from the Landau damping rate in magnitude and also, remarkably, in sign. A limit is demonstrated in which the density and current become phase-locked, which causes the effective damping to be negligible; this result offers a fresh perspective from which to reconsider recent observations of kinetic turbulence satisfying critical balance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗