Validating MCNP for LEU Fuel Design via Power Distribution Comparisons

The mission of the Reduced Enrichment for Research and Test Reactors (RERTR) Program is to minimize and, to the extent possible, eliminate the use of highly enriched uranium (HEU) in civilian nuclear applications by working to convert research and test reactors, as well as radioisotope production processes, to low enriched uranium (LEU) fuel and targets. Oak Ridge National Lab (ORNL) is reviewing the design bases and key operating criteria including fuel operating parameters, enrichment-related safety analyses, fuel performance, and fuel fabrication in regard to converting the fuel of the High Flux Isotope Reactor (HFIR) from HEU to LEU. The purpose of this study is to validate Monte Carlo methods currently in use for conversion analyses. The methods have been validated for the prediction of flux values in the reactor target, reflector, and beam tubes, but this study focuses on the prediction of the power density profile in the core. A current 3-D Monte Carlo N-Particle (MCNP) model was modified to replicate the HFIR Critical Experiment 3 (HFIRCE-3) core of 1965. In this experiment, the power profile was determined by counting the gamma activity at selected locations in the core. Foils (chunks of fuel meat and clad) were punched out of the fuel elements in HFIRCE-3 following irradiation and experimental relative power densities were obtained by measuring the activity of these foils and comparing each foil s activity to the activity of a normalizing foil. The current work consisted of calculating corresponding activities by inserting volume tallies into the modified MCNP model to represent the punchings. The average fission density was calculated for each foil location and then normalized to the normalizing foil. Power distributions were obtained for the clean core (no poison in moderator and symmetrical rod position at 17.5 inches) and fully poisoned-moderator (1.35 g B/liter in moderator and rods fully withdrawn) conditions. The observed deviations between the experimental and calculated values for both conditions were within the reported experimental uncertainties except for some of the foils located on the top and bottom edges of the fuel plates.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Active Control of Fan Noise-Feasibility Study. Volume 2: Canceling Noise Source-Design of an Acoustic Plate Radiator Using Piezoceramic Actuators

The feasibility of using acoustic plate radiators powered by piezoceramic thin sheets as canceling sources for active control of aircraft engine fan noise is demonstrated. Analytical and numerical models of actuated beams and plates are developed and validated. An optimization study is performed to identify the optimum combination of design parameters that maximizes the plate volume velocity for a given resonance frequency. Fifteen plates with various plate and actuator sizes, thicknesses, and bonding layers were fabricated and tested using results from the optimization study. A maximum equivalent piston displacement of 0.39 mm was achieved with the optimized plate samples tested with only one actuator powered, corresponding to a plate deflection at the center of over 1 millimeter. This is very close to the deflection required for a full size engine application and represents a 160-fold improvement over previous work. Experimental results further show that performance is limited by the critical stress of the piezoceramic actuator and bonding layer rather than by the maximum moment available from the actuator. Design enhancements are described in detail that will lead to a flight-worthy acoustic plate radiator by minimizing actuator tensile stresses and reducing nonlinear effects. Finally, several adaptive tuning methods designed to increase the bandwidth of acoustic plate radiators are analyzed including passive, active, and semi-active approaches. The back chamber pressurization and volume variation methods are investigated experimentally and shown to be simple and effective ways to obtain substantial control over the resonance frequency of a plate radiator. This study shows that piezoceramic-based plate radiators can be a viable acoustic source for active control of aircraft engine fan noise.

Pla, F. G.↗

Revisiting the validity of eddy viscosity models for predicting airflow over water waves

In this study, we revisit the validity of eddy viscosity models for predicting wave-induced airflow disturbances over ocean surface waves. We first derive a turbulence curvilinear model for the phase-averaged Navier–Stokes equations, extending the work of Cao, Deng & Shen (2020 J. Fluid Mech. 901, A27), by incorporating turbulence stress terms previously neglected in the linearised viscous curvilinear model. To verify our formulation, we perform a priori tests by numerically solving the model using mean wind and turbulence stress profiles from large-eddy simulations (LES) of airflow over waves across various wave ages. Results show that including turbulence stress terms improves wave-induced airflow predictions compared with the previous viscous curvilinear model. We further show that using a standard mixing-length eddy viscosity yields inaccurate predictions at certain wave ages, as it fails to capture wave-induced turbulence, which fundamentally differs from mean shear-driven turbulence. The LES data show that accurate representations of wave-induced stresses require a complex-valued eddy viscosity. The maximum magnitude of this eddy viscosity scales as ∼𝑢 𝜏 ⁢𝜁 𝑖𝑛𝑛𝑒𝑟 , where 𝑢 𝜏 is the friction velocity and 𝜁 𝑖𝑛𝑛𝑒𝑟 is the inner-layer thickness, the height at which the eddy-turnover time matches the wave advection time scale. This scaling aligns with the prediction by Belcher & Hunt (1993 J. Fluid Mech. 251, 109–148). Overall, the findings demonstrate that traditional eddy viscosity models are inadequate for capturing wave-induced turbulence. More sophisticated turbulence models are essential for the accurate prediction of airflow disturbances and form drag in wind–wave interaction models.

16 TIDAL AND WAVE POWER↗

WE-AB-303-11: Verification of a Deformable 4DCT Motion Model for Lung Tumor Tracking Using Different Driving Surrogates

Purpose: Tumor tracking is an advanced technique to treat intra-fractionally moving tumors. The aim of this study is to validate a surrogate-driven model based on four-dimensional computed tomography (4DCT) that is able to predict CT volumes corresponding to arbitrary respiratory states. Further, the comparison of three different driving surrogates is evaluated. Methods: This study is based on multiple 4DCTs of two patients treated for bronchial carcinoma and metastasis. Analyses for 18 additional patients are currently ongoing. The motion model was estimated from the planning 4DCT through deformable image registration. To predict a certain phase of a follow-up 4DCT, the model considers for inter-fractional variations (baseline correction) and intra-fractional respiratory parameters (amplitude and phase) derived from surrogates. In this evaluation, three different approaches were used to extract the motion surrogate: for each 4DCT phase, the 3D thoraco-abdominal surface motion, the body volume and the anterior-posterior motion of a virtual single external marker defined on the sternum were investigated. The estimated volumes resulting from the model were compared to the ground-truth clinical 4DCTs using absolute HU differences in the lung volume and landmarks localized using the Scale Invariant Feature Transform (SIFT). Results: The results show absolute HU differences between estimated and ground-truth images with median values limited to 55 HU and inter-quartile ranges (IQR) lower than 100 HU. Median 3D distances between about 1500 matching landmarks are below 2 mm for 3D surface motion and body volume methods. The single marker surrogates Result in increased median distances up to 0.6 mm. Analyses for the extended database incl. 20 patients are currently in progress. Conclusion: The results depend mainly on the image quality of the initial 4DCTs and the deformable image registration. All investigated surrogates can be used to estimate follow-up 4DCT phases, however uncertainties decrease for three-dimensional approaches. This work was funded in parts by the German Research Council (DFG) - KFO 214/2.

60 APPLIED LIFE SCIENCES↗

On SCALE Validation for PBR Analysis

Studies were performed to assess the capabilities of the SCALE code system to provide accurate cross sections for analyses of pebble bed reactor configurations. The analyzed configurations are representative of fuel in the HTR-10 reactor in the first critical core and at full power operation conditions. Relevant parameters-multiplication constant, spectral indices, few-group cross sections-are calculated with SCALE for the considered configurations. The results are compared to results obtained with corresponding consistent MCNP models. The code-to-code comparison shows good agreement at both room and operating temperatures, indicating a good performance of SCALE for analysis of doubly heterogeneous fuel configurations. The development of advanced methods and computational tools for the analysis of pebble bed reactor (PBR) configurations has been a research area of renewed interest for the international community during recent decades. The PBR, which is a High Temperature Gas Cooled Reactor (HTGR) system, represents one of the potential candidates for future deployment throughout the world of reactor systems that would meet the increased requirements of efficiency, safety, and proliferation resistance and would support other applications such as hydrogen production or nuclear waste recycling. In the U.S, the pebble bed design is one of the two designs under consideration by the Next Generation Nuclear Plant (NGNP) Program.

08 HYDROGEN↗

Validation of the aerosol optical property products derived by the GRASP/Component approach from multi-angular polarimetric observations

The multi-angle polarimetric satellite observations are helpful for improving the retrievals of aerosol parameters. However, practical applications of polarization technology are still limited because of complexity of measurement and interpretation of polarimetric observations. In this study, we analyze the performance of a new component approach developed in the frame of the Generalized Retrieval of Atmosphere and Surface Properties (GRASP) algorithm. In addition to aerosol optical properties including particle size distribution, non-sphericity and index of refraction that are commonly derived from multi-angle radiance and polarization measurements, the GRASP/Component approach also provides some information about aerosol composition. Specifically, in this approach aerosol is modeled as an internal mixture of several components with distinctly different chemical compositions and known refractive indices. The approach is intended not only to provide additional insight on aerosol composition but also to improve retrieval of basic aerosol optical properties. This study presents comprehensive validation and evaluation of Aerosol Optical Depth (AOD), Ångstrom exponent (AE), fine mode AOD (AODF), coarse mode AOD (AODC), and single scattering albedo (SSA) as retrieved by the GRASP/Component approach. The GRASP/Component products include aerosol retrievals using two different aerosol component mixing rules, i.e., Maxwell-Garnett (MG) effective medium approximation and a simple Volume- Weighted averaging (VW). The differences between the results obtained using these two assumptions are also discussed. The obtained results show that the aerosol optical property products of GRASP/Component approach have good agreement with the ground-based AERONET measurements, which is comparable to other PARASOL/ GRASP approaches. Specifically, the AOD retrieved by GRASP/Component approach show high correlation and nearly no bias both over land and ocean, as compared with AERONET. The more detailed aerosol properties such as AE, AODF, AODC and SSA also show one of the best comparisons with AERONET. These improvements can probably be attributed to the use of the additional physical constraints on spectral dependence of the complex refractive index and the reduction of total number of aerosol parameters directly retrieved in the GRASP/Component approach. In addition, the choice of mixing rules had no significant effect on optical retrievals. With the exception of SSA, the results obtained based on the MG mixing rule were found to be slightly better over those obtained using VW mixing rule, especially for bias.

Brent N Holben↗

Brownian Dynamics Simulation of Protein Solutions: Structural and Dynamical Properties

The study of solutions of biomacromolecules provides an important basis for understanding the behavior of many fundamental cellular processes, such as protein folding, self-assembly, biochemical reactions, and signal transduction. Here, we describe a Brownian dynamics simulation procedure and its validation for the study of the dynamic and structural properties of protein solutions. In the model used, the proteins are treated as atomically detailed rigid bodies moving in a continuum solvent. The protein-protein interaction forces are described by the sum of electrostatic interaction, electrostatic desolvation, nonpolar desolvation, and soft-core repulsion terms. The linearized Poisson-Boltzmann equation is solved to compute electrostatic terms. Simulations of homogeneous solutions of three different proteins with varying concentrations, pH, and ionic strength were performed. The results were compared to experimental data and theoretical values in terms of long-time self-diffusion coefficients, second virial coefficients, and structure factors. The results agree with the experimental trends and, in many cases, experimental values are reproduced quantitatively. There are no parameters specific to certain protein types in the interaction model, and hence the model should be applicable to the simulation of the behavior of mixtures of macromolecules in cell-like crowded environments.

59 BASIC BIOLOGICAL SCIENCES↗

Uncertainty analysis of PIV measurements in bubbly flows considering sampling and bubble effects with ray optics modeling

In this report, a modeling-based approach is developed to investigate the external sources of uncertainty in particle image velocimetry (PIV) measurements for two-phase bubbly flows. Primarily relied on ray optics modeling, this study focuses on the uncertainty in PIV measurements due to bubble-induced light distortion. In addition, the uncertainty due to sampling is also considered through synthetic PIV images generated from Monte Carlo sampling. Based on a PIV-planar laser induced florescence (PLIF) measurement system, three case studies are performed and discussed, considering respectively the sampling effect, bubble effect, and the combination of these two effects. These case studies confirm the validity of the ray optics modeling in obtaining accurate particle images through a benchmark test. Furthermore, it is also found that the bubble effect could significantly influence the particle images. On the other hand, the result of the case study with synthetic PIV images indicates that the bubble effect on particle images can be minimized by removing “outliers” in the obtained velocity vector field through a multi-pass post-processing procedure. However, the uncertainty of the velocity measurements will still increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Representative Phenomena of Cyclic Turbulent Combustion in High-Pressure Fuel Sprays

Abstract Cyclic variations in conventional diesel combustion engines can lead to large differences in engine out emissions even at steady operation. This study uses an optically accessible constant-pressure flow chamber to acquire fuel injections in quick succession to analyze mixing, auto-ignition, and combustion of diesel-surrogate n-heptane using multiple high-speed optical diagnostics. Prior studies have utilized fewer injections and/or they rely on analysis of ensemble average behavior. These approaches do not yield information on injection-to-injection variation or provide confidence in utilizing individual injection measurements for high-fidelity computational fluid dynamics(CFD) model validation. In this study, a large set of 500 injections is used to obtain global parameters including liquid length, vapor penetration length, ignition delay time, and lift-off length. Results for multiple injections are presented to illustrate large injection to injection variations. Potential sources for these variations are analyzed to conclude localized, small scale turbulence and rate of injection variations as the likely sources. Then, a statistical method based on z-scores is proposed and implemented to identify instantaneous injections that best represent the bulk data-set of jet boundaries measured independently by three different diagnostics. This synthesis of statistics-guided screening of data set and ensemble-average analysis offers higher confidence for CFD model validation relying upon both a representative single and average injection results.

42 ENGINEERING↗

Thermal Analysis of Large Area Additive Manufacturing Resistance Heating Composites for Out of Oven/Autoclave Applications

Additive Manufacturing (AM) of carbon fiber (CF) reinforced composite has received growing attention because of the design flexibility, superior mechanical properties, improved thermal properties, and weight reduction. Autoclave tooling was proven to be a successful application for large scale AM technology. The capital cost, and cost associated with heating, and cycle time in a conventional autoclave process is relatively high. Thus, an innovative design of AM mold with an efficient heating scheme is essential. This study represents an innovative method of the resistive heating of composite molds which does not require a room size oven for heating during the curing processing. Therefore, it has the potential to reduce the operating cost drastically. For the design validation and feasibility study, we performed a numerical analysis of the wire embedded and AM mold parts. The goal of this study is to determine and optimize the thermal behavior of the printed mold with embedded wire technology. It is anticipated that the larger distance between the embedded wires along the printing direction (z-direction) increase the cold spot, on the other hand, a close distance of the wire can create the unwanted localize heating, thus melting. Constant thermal properties of the 20 wt.% short CF reinforced acrylonitrile butadiene styrene (ABS) was used for the simulation purpose. Thermal characterization was set to 100°C to avoid the thermal deformation or bulging on the part surface.

billah, Kazi↗

Thermal Analysis of Large Area Additive Manufacturing Resistance Heating Composites for Out of Oven/Autoclave Applications

Additive Manufacturing (AM) of carbon fiber (CF) reinforced composite has received growing attention because of the design flexibility, superior mechanical properties, improved thermal properties, and weight reduction. Autoclave tooling was proven to be a successful application for large scale AM technology. The capital cost, and cost associated with heating, and cycle time in a conventional autoclave process is relatively high. Thus, an innovative design of AM mold with an efficient heating scheme is essential. This study represents an innovative method of the resistive heating of composite molds which does not require a room size oven for heating during the curing processing. Therefore, it has the potential to reduce the operating cost drastically. For the design validation and feasibility study, we performed a numerical analysis of the wire embedded and AM mold parts. The goal of this study is to determine and optimize the thermal behavior of the printed mold with embedded wire technology. It is anticipated that the larger distance between the embedded wires along the printing direction (z-direction) increase the cold spot, on the other hand, a close distance of the wire can create the unwanted localize heating, thus melting. Constant thermal properties of the 20 wt.% short CF reinforced acrylonitrile butadiene styrene (ABS) was used for the simulation purpose. Thermal characterization was set to 100°C to avoid the thermal deformation or bulging on the part surface.

billah, Kazi↗

Thermal Analysis of Large Area Additive Manufacturing Resistance Heating Composites for Out of Oven/Autoclave Applications

Additive Manufacturing (AM) of carbon fiber (CF) reinforced composite has received growing attention because of the design flexibility, superior mechanical properties, improved thermal properties, and weight reduction. Autoclave tooling was proven to be a successful application for large scale AM technology. The capital cost, and cost associated with heating, and cycle time in a conventional autoclave process is relatively high. Thus, an innovative design of AM mold with an efficient heating scheme is essential. This study represents an innovative method of the resistive heating of composite molds which does not require a room size oven for heating during the curing processing. Therefore, it has the potential to reduce the operating cost drastically. For the design validation and feasibility study, we performed a numerical analysis of the wire embedded and AM mold parts. The goal of this study is to determine and optimize the thermal behavior of the printed mold with embedded wire technology. It is anticipated that the larger distance between the embedded wires along the printing direction (z-direction) increase the cold spot, on the other hand, a close distance of the wire can create the unwanted localize heating, thus melting. Constant thermal properties of the 20 wt.% short CF reinforced acrylonitrile butadiene styrene (ABS) was used for the simulation purpose. Thermal characterization was set to 100°C to avoid the thermal deformation or bulging on the part surface.

billah, Kazi↗

Ultrasound guided fluorescence molecular tomography with improved quantification by an attenuation compensated born-normalization and in vivo preclinical study of cancer

Ultrasound imaging, having the advantages of low-cost and non-invasiveness over MRI and X-ray CT, was reported by several studies as an adequate complement to fluorescence molecular tomography with the perspective of improving localization and quantification of fluorescent molecular targets in vivo. Based on the previous work, an improved dual-modality Fluorescence-Ultrasound imaging system was developed and then validated in imaging study with preclinical tumor model. Ultrasound imaging and a profilometer were used to obtain the anatomical prior information and 3D surface, separately, to precisely extract the tissue boundary on both sides of sample in order to achieve improved fluorescence reconstruction. Furthermore, a pattern-based fluorescence reconstruction on the detection side was incorporated to enable dimensional reduction of the dataset while keeping the useful information for reconstruction. Due to its putative role in the current imaging geometry and the chosen reconstruction technique, we developed an attenuation compensated Born-normalization method to reduce the attenuation effects and cancel off experimental factors when collecting quantitative fluorescence datasets over large area. Results of both simulation and phantom study demonstrated that fluorescent targets could be recovered accurately and quantitatively using this reconstruction mechanism. Finally, in vivo experiment confirms that the imaging system associated with the proposed image reconstruction approach was able to extract both functional and anatomical information, thereby improving quantification and localization of molecular targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postmortem validation of breast density using dual-energy mammography

Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.

60 APPLIED LIFE SCIENCES↗

Creep crack-growth: A new path-independent integral (T sub c), and computational studies

The development of valid creep fracture criteria is considered. Two path-independent integral parameters which show some degree of promise are the C* and (Delta T)sub c integrals. The mathematical aspects of these parameters are reviewed by deriving generalized vector forms of the parameters using conservation laws which are valid for arbitrary, three dimensional, cracked bodies with crack surface tractions (or applied displacements), body forces, inertial effects, and large deformations. Two principal conclusions are that (Delta T)sub c has an energy rate interpretation whereas C* does not. The development and application of fracture criteria often involves the solution of boundary/initial value problems associated with deformation and stresses. The finite element method is used for this purpose. An efficient, small displacement, infinitesimal strain, displacement based finite element model is specialized to two dimensional plane stress and plane strain and to power law creep constitutive relations. A mesh shifting/remeshing procedure is used for simulating crack growth. The model is implemented with the quartz-point node technique and also with specially developed, conforming, crack-tip singularity elements which provide for the r to the n-(1+n) power strain singularity associated with the HRR crack-tip field. Comparisons are made with a variety of analytical solutions and alternate numerical solutions for a number of problems.

Stonesifer, R. B.↗