Search NASA⌕ Search

SEARCH · Search NASA

Results for “Approach”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Approach for Selection of Rayleigh Damping Parameters Used for Time History Analysis

Nonlinearities, whether geometric or material, need to be addressed in seismic analysis. One good analysis method that can address these nonlinearities is direct time integration with Rayleigh damping. Modal damping is the damping typically specified in seismic analysis Codes and Standards. Modal damping is constant for all frequencies where Rayleigh damping varies with frequency. An approach is proposed here for selection of Rayleigh damping coefficients to be used in seismic analyses that is consistent with given Modal damping. The approach uses the difference between the modal damping response and the Rayleigh damping response along with effective mass properties of the model being evaluated to match overall system response levels. This paper provides a simple example problem to demonstrate the approach. It also provides results for a finite element model representing an existing piping system. Displacement, acceleration, and stress results are compared from model runs using modal damping and model runs using Rayleigh damping with coefficients selected using the proposed method.

42 ENGINEERING↗

A Cyclic-Plasticity-Based Mechanistic Approach for Fatigue Evaluation of 316 Stainless Steel Under Arbitrary Loading

In this paper, a cyclic-plasticity based fully mechanistic fatigue modeling approach is presented. This is based on time-dependent stress-strain evolution of the material over the entire fatigue life rather than just based on the end of live information typically used for empirical S~N curve based fatigue evaluation approaches. Previously we presented constant amplitude fatigue test based related material models for 316 SS base, 508 LAS base and 316 SS- 316 SS weld which are used in nuclear reactor components such as pressure vessels, nozzles, and surge line pipes. However, we found that constant amplitude fatigue data based models have limitation in capturing the stress-strain evolution under arbitrary fatigue loading. To address the above mentioned limitation, in this paper, we present a more advanced approach that can be used for modeling the cyclic stress-strain evolution and fatigue life not only under constant amplitude but also under any arbitrary (random/variable) fatigue loading. The related material model and analytical model results are presented for 316 SS base metal. Two methodologies (either based on time/cycle or based on accumulated plastic strain energy) to track the material parameters at a given time/cycle are discussed and associated analytical model results are presented. From the material model and analytical cyclic plasticity model results, it is found that the proposed cyclic plasticity model can predict all the important stages of material behavior during the entire fatigue life of the specimens with more than 90% accuracy

316 Stainless Steel↗

A Novel Active Optimization Approach for Rapid and Efficient Design Space Exploration Using Ensemble Machine Learning

In this work, a novel design optimization technique based on active learning, which involves dynamic exploration and exploitation of the design space of interest using an ensemble of machine learning algorithms, is presented. In this approach, a hybrid methodology incorporating an explorative weak learner (regularized basis function model) that fits high-level information about the response surface and an exploitative strong learner (based on committee machine) that fits finer details around promising regions identified by the weak learner is employed. For each design iteration, an aristocratic approach is used to select a set of nominees, where points that meet a threshold merit value as predicted by the weak learner are selected for evaluation. In addition to these points, the global optimum as predicted by the strong learner is also evaluated to enable rapid convergence to the actual global optimum once the most promising region has been identified by the optimizer. Additionally, this methodology is first tested by applying it to the optimization of a two-dimensional multi-modal surface and, subsequently, to a complex internal combustion (IC) engine combustion optimization case with nine control parameters related to fuel injection, initial thermodynamic conditions, and in-cylinder flow. It is found that the new approach significantly lowers the number of function evaluations that are needed to reach the optimum design configuration (by up to 80%) when compared to conventional optimization techniques, such as particle swarm and genetic algorithm-based optimization techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Approach to Bayesian Optimization for Design Feasibility Check on Discontinuous Black-Box Functions

The paper presents a novel approach to applying Bayesian Optimization (BO) in predicting an unknown constraint boundary, also representing the discontinuity of an unknown function, for a feasibility check on the design space, thereby representing a classification tool to discern between a feasible and infeasible region. Bayesian optimization is a low-cost black-box global optimization tool in the Sequential Design Methods where one learns and updates knowledge from prior evaluated designs, and proceeds to the selection of new designs for future evaluation. However, BO is best suited to problems with the assumption of a continuous objective function and does not guarantee true convergence when having a discontinuous design space. This is because of the insufficient knowledge of the BO about the nature of the discontinuity of the unknown true function. In this paper, we have proposed to predict the location of the discontinuity using a BO algorithm on an artificially projected continuous design space from the original discontinuous design space. The proposed approach has been implemented in a thin tube design with the risk of creep-fatigue failure under constant loading of temperature and pressure. The stated risk depends on the location of the designs in terms of safe and unsafe regions, where the discontinuities lie at the transition between those regions; therefore, the discontinuity has also been treated as an unknown creep-fatigue failure constraint. The proposed BO algorithm has been trained to maximize sampling toward the unknown transition region, to act as a high accuracy classifier between safe and unsafe designs with minimal training cost. The converged solution has been validated for different design parameters with classification error rate and function evaluations at an average of <1% and ~150, respectively. Finally, the performance of our proposed approach in terms of training cost and classification accuracy of thin tube design is shown to be better than the existing machine learning (ML) algorithms such as Support Vector Machine (SVM), Random Forest (RF), and Boosting.

Engineering↗

Uncertainty-Aware, Structure-Preserving Machine Learning Approach for Domain Shift Detection From Nonlinear Dynamic Responses of Structural Systems

Complex structural systems deployed for aerospace, civil, or mechanical applications must operate reliably under varying operational conditions. Structural health monitoring (SHM) systems help ensure the reliability of these systems by providing continuous monitoring of the state of the structure. SHM relies on synthesizing measured data with a predictive model to make informed decisions about structural states. However, these models—which may be thought of as a form of a digital twin—need to be updated continuously as structural changes (e.g., due to damage) arise. We propose an uncertainty-aware machine learning model that enforces distance preservation of the original input state space and then encodes a distance-aware mechanism via a Gaussian process (GP) kernel. The proposed approach leverages the spectral-normalized neural GP algorithm to combine the flexibility of neural networks with the advantages of GP, subjected to structure-preserving constraints, to produce an uncertainty-aware model. This model is used to detect domain shift due to structural changes that cannot be observed directly because they may be spatially isolated (e.g., inside a joint or localized damage). This work leverages detection theory to detect domain shift systematically given statistical features of the prediction variance produced by the model. The proposed approach is demonstrated on a nonlinear structure being subjected to damage conditions. In conclusion, it is shown that the proposed approach is able to rely on distances of the transformed input state space to predict increased variance in shifted domains while being robust to normative changes.

Algorithms↗

Chemical Reactor Network Modeling of Ammonia Rich-Quench-Lean Combustion Using a Partially Stirred Reactor Approach

Ammonia is a promising alternative to hydrogen with high energy density and favorable storage and transport characteristics. However, low flammability and a propensity for high nitrogen oxide (NO x ) emissions make direct utilization challenging. Recently, two-stage rich-quench-lean (RQL) combustion strategies have shown promise in achieving low NO x emissions with ammonia. In this approach, the rich stage serves to oxidize a portion of the fuel while thermally decomposing as much of the remaining ammonia as possible, generating hydrogen. In the second (lean) stage, air is rapidly introduced, burning out the hydrogen and residual ammonia. Two-stage RQL combustion of ammonia has been investigated in the open literature both experimentally and numerically. In general, idealized chemical reactor network (CRN) models predict NO x concentrations below those of 2D/3D computational fluid dynamics models and experiments. The primary drivers of these discrepancies may be largely attributed to finite rate mixing nonadiabatic operation. The typical CRN model is comprised of a perfectly-stirred-reactor (PSR), followed by a plug-flow-reactor (PFR), meant to represent the flame, and postflame zones, respectively. In the two-stage RQL approach two PSR-PFR networks are arranged sequentially, corresponding to the rich and lean stages, with secondary air injection in between. In the authors' past work, this arrangement has demonstrated the significant sensitivity of exit NO x to the rich stage equivalence ratio, while the amount of secondary air injection was shown to be less critical. In this paper, the CRN model is extended to (1) include the impacts of heat loss and (2) utilize a partially-stirred-reactor (PaSR) approach to study the impacts of mixing on emissions performance. Varying amounts of heat loss are applied to the rich relaxation zone to understand emissions performance and changes to optimization of equivalence ratio and residence time. Premixed and nonpremixed configurations are considered in the rich stage PaSR, with varying degrees of mixing intensity to study the interaction between mixing, transport, and kinetic timescales. Critically, the impact of mixing between hot products and secondary air injection is studied to understand practical injector needs. Results show unburnt ammonia leaving the rich stage as a primary contributor to NO x emissions – driven both by increased heat loss and reduced mixing rates. Furthermore, heat losses have been shown to create conditions that are conducive to increased N 2 O formation in the lean stage. In conclusion, the results of this study will be considered in the context of developing optimized two-stage RQL combustors for ammonia.

Combustion↗

An integrated approach to geological disposal of UK wastes containing carbon-14

Carbon-14 is a key radionuclide in the assessment of the safety of a geological disposal facility for radioactive waste because of the calculated assessment of the radiological consequences of gaseous carbon-14 bearing species [i]. It may be that such calculations are based on overly conservative assumptions and that better understanding could lead to considerably reduced assessment of the radiological consequences from these wastes. Alternatively, it may be possible to mitigate the impact of these wastes through alternative treatment, packaging or design options. The Radioactive Waste Management Directorate of the UK's Nuclear Decommissioning Authority (NDA RWMD) has established an integrated project team in which the partners are working together to develop a holistic approach to carbon-14 management in the disposal system [ii]. For a waste stream containing carbon-14 to be an issue: There must be a significant inventory of carbon-14 in the waste stream; and That waste stream has to generate carbon-14 bearing gas; and a bulk gas phase has to entrain the carbon-14 bearing gas: and these gases must migrate through the engineered barriers in significant quantities; and these gases must migrate through the overlying geological environment (either as a distinct gas phase or as dissolved gas); and these gases must interact with materials in the biosphere (i.e. plants) in a manner that leads to significant doses and risks to exposed groups or potentially exposed groups. The project team has developed and used this 'and' approach to structure and prioritise the technical work and break the problem down in a manageable way. We have also used it to develop our approach to considering alternative treatment, packaging and design options. For example, it may be possible to pre-treat some wastes to remove some of the inventory or to segregate other wastes so that they are removed from any bulk gas phase which might facilitate migration through the geosphere. Initially, the project team has undertaken a six month programme of work to examine the current understanding of these aspects and has captured this in the Phase 1 report [ii], in a modelling basis spreadsheet and in scoping assessments, which help us better understand the potential significance of carbon-14. Using the current modelling basis, but ignoring any potential benefits from the geosphere in retarding or preventing gas from reaching the surface, the calculated release of carbon- 14 is dominated by: corrosion of irradiated reactive metals (in the operational and early post-closure time frame); corrosion of irradiated stainless steel and leaching of irradiated graphite (in the longer term). The Phase 1 work has shown that there is considerable scope for reducing the calculated radiological consequence for these wastes and a roadmap has been developed for a second Phase of work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling the Ductile Brittle Fracture Transition in Reactor Pressure Vessel Steels using a Cohesive Zone Model based approach

Fracture properties of Reactor Pressure Vessel (RPV) steels show large variations with changes in temperature and irradiation levels. Brittle behavior is observed at lower temperatures and/or higher irradiation levels whereas ductile mode of failure is predominant at higher temperatures and/or lower irradiation levels. In addition to such temperature and radiation dependent fracture behavior, significant scatter in fracture toughness has also been observed. As a consequence of such variability in fracture behavior, accurate estimates of fracture properties of RPV steels are of utmost importance for safe and reliable operation of reactor pressure vessels. A cohesive zone based approach is being pursued in the present study where an attempt is made to obtain a unified law capturing both stable crack growth (ductile fracture) and unstable failure (cleavage fracture). The parameters of the constitutive model are dependent on both temperature and failure probability. The effect of irradiation has not been considered in the present study. The use of such a cohesive zone based approach would allow the modeling of explicit crack growth at both stable and unstable regimes of fracture. Also it would provide the possibility to incorporate more physical lower length scale models to predict DBT. Such a multi-scale approach would significantly improve the predictive capabilities of the model, which is still largely empirical.

36 MATERIALS SCIENCE↗

A data-driven approach to sampling matrix selection for compressive sensing

Sampling is a fundamental aspect of any implementation of compressive sensing. Typically, the choice of sampling method is guided by the reconstruction basis. However, this approach can be problematic with respect to certain hardware constraints and is not responsive to domain-specific context. We propose a method for defining an order for a sampling basis that is optimal with respect to capturing variance in data, thus allowing for meaningful sensing at any desired level of compression. We focus on the Walsh-Hadamard sampling basis for its relevance to hardware constraints, but our approach applies to any sampling basis of interest. We illustrate the effectiveness of our method on the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset, the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset, and a Colorado State University Swiss Ranger depth image dataset. The spectral datasets consist of simulant experiments, including releases of chemicals such as GAA and SF6. We combine our sampling and reconstruction with the adaptive coherence estimator (ACE) and bulk coherence for chemical detection and we incorporate an algorithmic threshold for ACE values to determine the presence or absence of a chemical. We compare results across sampling methods in this context. We have successful chemical detection at a compression rate of 90%. For all three datasets, we compare our sampling approach to standard orderings of sampling basis such as random, sequency, and an analog of sequency that we term `frequency.' In one instance, the peak signal to noise ratio was improved by over 30% across a test set of depth images.

compressive sensing, hyperspectral imaging, Walsh-↗

Coronary centerline extraction from CT coronary angiography images using a minimum cost path approach

Purpose: The application and large-scale evaluation of minimum cost path approaches for coronary centerline extraction from computed tomography coronary angiography (CTCA) data and the development and evaluation of a novel method to reduce the user-interaction time. Methods: A semiautomatic method based on a minimum cost path approach is evaluated for two different cost functions. The first cost function is based on a frequently used vesselness measure and intensity information, and the second is a recently proposed cost function based on region statistics. User interaction is minimized to one or two mouse clicks distally in the coronary artery. The starting point for the minimum cost path search is automatically determined using a newly developed method that finds a point in the center of the aorta in one of the axial slices. This step ensures that all computationally expensive parts of the algorithm can be precomputed. Results: The performance of the aorta localization procedure was demonstrated by a success rate of 100% in 75 images. The success rate and accuracy of centerline extraction was quantitatively evaluated on 48 coronary arteries in 12 images by comparing extracted centerlines with a manually annotated reference standard. The method was able to extract 88% and 47% of the vessel centerlines correctly using the vesselness/intensity and region statistics cost function, respectively. For only the proximal part of the vessels these values were 97% and 86%, respectively. Accuracy of centerline extraction, defined as the average distance from correctly automatically extracted parts of the centerline to the reference standard, was 0.64 mm for the vesselness/intensity and 0.51 mm for the region statistics cost function. The interobserver variability was 99% for the success rate measure and 0.42 mm for the accuracy measure. Qualitative evaluation using the best performing cost function resulted in successful centerline extraction for 233 out of the 252 coronaries (92%) in 63 additional CTCA images. Conclusions: The presented results, in combination with minimal user interaction and low computation time, show that minimum cost path approaches can effectively be applied as a preprocessing step for subsequent analysis in clinical practice and biomedical research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PARETO: A novel evolutionary optimization approach to multiobjective IMRT planning

Purpose: In radiation therapy treatment planning, the clinical objectives of uniform high dose to the planning target volume (PTV) and low dose to the organs-at-risk (OARs) are invariably in conflict, often requiring compromises to be made between them when selecting the best treatment plan for a particular patient. In this work, the authors introduce Pareto-Aware Radiotherapy Evolutionary Treatment Optimization (pareto), a multiobjective optimization tool to solve for beam angles and fluence patterns in intensity-modulated radiation therapy (IMRT) treatment planning. Methods: pareto is built around a powerful multiobjective genetic algorithm (GA), which allows us to treat the problem of IMRT treatment plan optimization as a combined monolithic problem, where all beam fluence and angle parameters are treated equally during the optimization. We have employed a simple parameterized beam fluence representation with a realistic dose calculation approach, incorporating patient scatter effects, to demonstrate feasibility of the proposed approach on two phantoms. The first phantom is a simple cylindrical phantom containing a target surrounded by three OARs, while the second phantom is more complex and represents a paraspinal patient. Results: pareto results in a large database of Pareto nondominated solutions that represent the necessary trade-offs between objectives. The solution quality was examined for several PTV and OAR fitness functions. The combination of a conformity-based PTV fitness function and a dose-volume histogram (DVH) or equivalent uniform dose (EUD) -based fitness function for the OAR produced relatively uniform and conformal PTV doses, with well-spaced beams. A penalty function added to the fitness functions eliminates hotspots. Comparison of resulting DVHs to those from treatment plans developed with a single-objective fluence optimizer (from a commercial treatment planning system) showed good correlation. Results also indicated that pareto shows promise in optimizing the number of beams. Conclusions: This initial evaluation of the evolutionary optimization software tool pareto for IMRT treatment planning demonstrates feasibility and provides motivation for continued development. Advantages of this approach over current commercial methods for treatment planning are many, including: (1) fully automated optimization that avoids human controlled iterative optimization and potentially improves overall process efficiency, (2) formulation of the problem as a true multiobjective one, which provides an optimized set of Pareto nondominated solutions refined over hundreds of generations and compiled from thousands of parameter sets explored during the run, and (3) rapid exploration of the final nondominated set accomplished by a graphical interface used to select the best treatment option for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Auto-segmentation of normal and target structures in head and neck CT images: A feature-driven model-based approach

Purpose: Intensity modulated radiation therapy (IMRT) allows greater control over dose distribution, which leads to a decrease in radiation related toxicity. IMRT, however, requires precise and accurate delineation of the organs at risk and target volumes. Manual delineation is tedious and suffers from both interobserver and intraobserver variability. State of the art auto-segmentation methods are either atlas-based, model-based or hybrid however, robust fully automated segmentation is often difficult due to the insufficient discriminative information provided by standard medical imaging modalities for certain tissue types. In this paper, the authors present a fully automated hybrid approach which combines deformable registration with the model-based approach to accurately segment normal and target tissues from head and neck CT images. Methods: The segmentation process starts by using an average atlas to reliably identify salient landmarks in the patient image. The relationship between these landmarks and the reference dataset serves to guide a deformable registration algorithm, which allows for a close initialization of a set of organ-specific deformable models in the patient image, ensuring their robust adaptation to the boundaries of the structures. Finally, the models are automatically fine adjusted by our boundary refinement approach which attempts to model the uncertainty in model adaptation using a probabilistic mask. This uncertainty is subsequently resolved by voxel classification based on local low-level organ-specific features. Results: To quantitatively evaluate the method, they auto-segment several organs at risk and target tissues from 10 head and neck CT images. They compare the segmentations to the manual delineations outlined by the expert. The evaluation is carried out by estimating two common quantitative measures on 10 datasets: volume overlap fraction or the Dice similarity coefficient (DSC), and a geometrical metric, the median symmetric Hausdorff distance (HD), which is evaluated slice-wise. They achieve an average overlap of 93% for the mandible, 91% for the brainstem, 83% for the parotids, 83% for the submandibular glands, and 74% for the lymph node levels. Conclusions: Our automated segmentation framework is able to segment anatomy in the head and neck region with high accuracy within a clinically-acceptable segmentation time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration

Purpose: In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. However, uncertainties in the mapping of the images can translate into errors of the accumulated total dose, depending on the dose gradient. In this work, an approach to estimate the uncertainty of mapping between medical images is proposed that identifies areas bearing a significant risk of inaccurate dose accumulation. Methods: This method accounts for the geometric uncertainty of image registration and the heterogeneity of the dose distribution, which is to be mapped. Its performance is demonstrated in context of dose mapping based on b-spline registration. It is based on evaluation of the sensitivity of dose mapping to variations of the b-spline coefficients combined with evaluation of the sensitivity of the registration metric with respect to the variations of the coefficients. It was evaluated based on patient data that was deformed based on a breathing model, where the ground truth of the deformation, and hence the actual true dose mapping error, is known. Results: The proposed approach has the potential to distinguish areas of the image where dose mapping is likely to be accurate from other areas of the same image, where a larger uncertainty must be expected. Conclusions: An approach to identify areas where dose mapping is likely to be inaccurate was developed and implemented. This method was tested for dose mapping, but it may be applied in context of other mapping tasks as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simplified approach to characterizing a kilovoltage source spectrum for accurate dose computation

Purpose: To investigate and validate the clinical feasibility of using half-value layer (HVL) and peak tube potential (kVp) for characterizing a kilovoltage (kV) source spectrum for the purpose of computing kV x-ray dose accrued from imaging procedures. To use this approach to characterize a Varian Registered-Sign On-Board Imager Registered-Sign (OBI) source and perform experimental validation of a novel in-house hybrid dose computation algorithm for kV x-rays. Methods: We characterized the spectrum of an imaging kV x-ray source using the HVL and the kVp as the sole beam quality identifiers using third-party freeware Spektr to generate the spectra. We studied the sensitivity of our dose computation algorithm to uncertainties in the beam's HVL and kVp by systematically varying these spectral parameters. To validate our approach experimentally, we characterized the spectrum of a Varian Registered-Sign OBI system by measuring the HVL using a Farmer-type Capintec ion chamber (0.06 cc) in air and compared dose calculations using our computationally validated in-house kV dose calculation code to measured percent depth-dose and transverse dose profiles for 80, 100, and 125 kVp open beams in a homogeneous phantom and a heterogeneous phantom comprising tissue, lung, and bone equivalent materials. Results: The sensitivity analysis of the beam quality parameters (i.e., HVL, kVp, and field size) on dose computation accuracy shows that typical measurement uncertainties in the HVL and kVp ({+-}0.2 mm Al and {+-}2 kVp, respectively) source characterization parameters lead to dose computation errors of less than 2%. Furthermore, for an open beam with no added filtration, HVL variations affect dose computation accuracy by less than 1% for a 125 kVp beam when field size is varied from 5 Multiplication-Sign 5 cm{sup 2} to 40 Multiplication-Sign 40 cm{sup 2}. The central axis depth dose calculations and experimental measurements for the 80, 100, and 125 kVp energies agreed within 2% for the homogeneous and heterogeneous block phantoms, and agreement for the transverse dose profiles was within 6%. Conclusions: The HVL and kVp are sufficient for characterizing a kV x-ray source spectrum for accurate dose computation. As these parameters can be easily and accurately measured, they provide for a clinically feasible approach to characterizing a kV energy spectrum to be used for patient specific x-ray dose computations. Furthermore, these results provide experimental validation of our novel hybrid dose computation algorithm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Objected constrained registration and manifold learning: A new patient setup approach in image guided radiation therapy of thoracic cancer

Purpose: The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. Methods: For 11 lung cancer patients a long training fluoroscopy was acquired before the first treatment, and multiple short testing fluoroscopies were acquired weekly at the pretreatment patient setup of image guided radiotherapy (IGRT). The data analysis consisted of three steps: first a 4D target motion model was constructed from 4DCT and projected to the training fluoroscopy through deformable registration. Then the manifold learning method was used to construct a 2D subspace based on the target motion (kinetic) and location (static) information in the training fluoroscopy. Thereafter the respiratory phase in the testing fluoroscopy was determined by finding its location in the subspace. Finally, the phase determined testing fluoroscopy was registered to the corresponding 4DCT to derive the pretreatment patient position adjustment for the IGRT. The method was tested on clinical image sets and numerical phantoms. Results: The registration successfully reconstructed the 4D motion model with over 98% volume similarity in 4DCT, and over 95% area similarity in the training fluoroscopy. The machine learning method derived the phase values in over 98% and 93% test images of the phantom and patient images, respectively, with less than 3% phase error. The setup approach achieved an average accumulated setup error less than 1.7 mm in the cranial-caudal direction and less than 1 mm in the transverse plane. All results were validated against the ground truth of manual delineations by an experienced radiation oncologist. The expected total time for the pretreatment setup analysis was less than 10 s. Conclusions: By combining the registration and machine learning, the proposed approach has the potential to improve the accuracy of pretreatment setup for patients with thoracic malignancy.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-01: A Probabilistic Bayesian Approach to Derive Electron Density From MRI for Radiation Therapy Treatment Planning

Purpose: MRI significantly improves the accuracy and reliability of target delineation for patient simulation and treatment planning in radiation therapy, due to its superior soft tissue contrast as compared to CT. An MRI based simulation will reduce cost and simplify clinical workflow with zero ionizing radiation. However, MRI lacks the key electron density information. The purpose of this work is to develop a reliable method to derive electron density from MRI. Methods: We adopt a probabilistic Bayesian approach for electron density mapping based on T1-weighted head MRI. For each voxel, we compute conditional probability of electron densities given its: (1) T1 intensity and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of test patient and atlas. Intensity and geometry information are combined into a unifying posterior probability density function whose mean gives the electron density. Mean absolute HU error between the estimated and true CT, as well as ROC's for bone detection (HU>200) were calculated for 8 patients. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). Results: The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 132, compared with 139 for deformable registration (p=10{sup −3}), 371 for the intensity approach (p=10{sup −5}) and 282 without density correction (p=2×10{sup −4}). For 90% sensitivity in bone detection, the proposed method had a specificity of 85% and that for deformable registration, intensity and without density correction are 80%, 24% and 10% respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection from MRI of the head with highly heterogeneous regions. This paves the way for accurate dose calculation and generating reference images for patient setup in MRI-based treatment planning.

60 APPLIED LIFE SCIENCES↗

Radiation dose calculations for CT scans with tube current modulation using the approach to equilibrium function

Purpose: The approach to equilibrium function has been used previously to calculate the radiation dose to a shift-invariant medium undergoing CT scans with constant tube current [Li, Zhang, and Liu, Med. Phys. 39, 5347–5352 (2012)]. The authors have adapted this method to CT scans with tube current modulation (TCM). Methods: For a scan with variable tube current, the scan range was divided into multiple subscan ranges, each with a nearly constant tube current. Then the dose calculation algorithm presented previously was applied. For a clinical CT scan series that presented tube current per slice, the authors adopted an efficient approach that computed the longitudinal dose distribution for one scan length equal to the slice thickness, which center was at z = 0. The cumulative dose at a specific point was a summation of the contributions from all slices and the overscan. Results: The dose calculations performed for a total of four constant and variable tube current distributions agreed with the published results of Dixon and Boone [Med. Phys. 40, 111920 (14pp.) (2013)]. For an abdomen/pelvis scan of an anthropomorphic phantom (model ATOM 701-B, CIRS, Inc., VA) on a GE Lightspeed Pro 16 scanner with 120 kV, N × T = 20 mm, pitch = 1.375, z axis current modulation (auto mA), and angular current modulation (smart mA), dose measurements were performed using two lines of optically stimulated luminescence dosimeters, one of which was placed near the phantom center and the other on the surface. Dose calculations were performed on the central and peripheral axes of a cylinder containing water, whose cross-sectional mass was about equal to that of the ATOM phantom in its abdominal region, and the results agreed with the measurements within 28.4%. Conclusions: The described method provides an effective approach that takes into account subject size, scan length, and constant or variable tube current to evaluate CT dose to a shift-invariant medium. For a clinical CT scan, dose calculations may be performed with a water-containing cylinder whose cross-sectional mass is equal to that of the subject. This method has the potential to substantially improve evaluations of patient dose from clinical CT scans, compared to CTDI{sub vol}, size-specific dose estimate (SSDE), or the dose evaluated for a TCM scan with a constant tube current equal to the average tube current of the TCM scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of new approaches in GRID therapy using nonconventional radiation sources

Purpose: Spatial fractionation of the dose has proven to be a promising approach to increase the tolerance of healthy tissue, which is the main limitation of radiotherapy. A good example of that is GRID therapy, which has been successfully used in the management of large tumors with low toxicity. The aim of this work is to explore new avenues using nonconventional sources: GRID therapy by using kilovoltage (synchrotron) x-rays, the use of very high-energy electrons, and proton GRID therapy. They share in common the use of the smallest possible grid sizes in order to exploit the dose–volume effects. Methods: Monte Carlo simulations (PENELOPE/PENEASY and GEANT4/GATE codes) were used as a method to study dose distributions resulting from irradiations in different configurations of the three proposed techniques. As figure of merit, percentage (peak and valley) depth dose curves, penumbras, and central peak-to-valley dose ratios (PVDR) were evaluated. As shown in previous biological experiments, high PVDR values are requested for healthy tissue sparing. A superior tumor control may benefit from a lower PVDR. Results: High PVDR values were obtained in the healthy tissue for the three cases studied. When low energy photons are used, the treatment of deep-seated tumors can still be performed with submillimetric grid sizes. Superior PVDR values were reached with the other two approaches in the first centimeters along the beam path. The use of protons has the advantage of delivering a uniform dose distribution in the tumor, while healthy tissue benefits from the spatial fractionation of the dose. In the three evaluated techniques, there is a net reduction in penumbra with respect to radiosurgery. Conclusions: The high PVDR values in the healthy tissue and the use of small grid sizes in the three presented approaches might constitute a promising alternative to treat tumors with such spatially fractionated radiotherapy techniques. The dosimetric results presented here support the interest of performing radiobiology experiments in order to evaluate these new avenues.

07 ISOTOPE AND RADIATION SOURCES↗