Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Tank 12H Acidic Chemical Cleaning Sample Analysis And Material Balance

A process of Bulk Oxalic Acid (BOA) chemical cleaning was performed for Tank 12H during June and July of 2013 to remove all or a portion of the approximately 4400 gallon sludge heel. Three strikes of oxalic acid (nominally 4 wt% or 2 wt%) were used at 55°C and tank volumes of 96- to 140-thousand gallons. This report details the sample analysis of a scrape sample taken prior to BOA cleaning and dip samples taken during BOA cleaning. It also documents a rudimentary material balance for the Tank 12H cleaning results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantification of UV-Visible and Laser Spectroscopic Techniques for Materials Accountability and Process Control

Ultraviolet–visible spectroscopy (UV–Visible) and time-resolved laser fluorescence spectroscopy (TRLFS) optical techniques can permit on-line analysis of actinide elements in a solvent extraction process in real time. These techniques have been used for measuring actinide speciation and concentration under laboratory conditions and are easily adaptable to multiple sampling geometries, such as dip probes, fiber-optic sample cells, and flow-through cell geometries. To fully exploit these techniques, researchers must determine the fundamental speciation of target actinides and the resulting influence on spectroscopic properties. Detection limits, process conditions, and speciation of key actinide components can be established and utilized in a range of areas, particularly those related to materials accountability and process control. Through this project, researchers will develop tools and spectroscopic techniques to evaluate solution extraction conditions and concentrations of U, Pu, and Cm in extraction processes, addressing areas of process control and materials accountability. The team will evaluate UV– Visible and TRLFS for use in solvent extraction-based separations. Ongoing research is examining efficacy of UV-Visible spectroscopy to evaluate uranium and plutonium speciation under conditions found in the UREX process and using TRLFS to evaluate Cm speciation and concentration in the TALSPEAK process. A uranyl and plutonium nitrate UV–Visible spectroscopy study met with success, which supports the utility and continued exploration of spectroscopic methods for evaluation of actinide concentrations and solution conditions for other aspects of the UREX+ solvent extraction scheme. This project will examine U and Pu absorbance in TRUEX and TALSPEAK, perform detailed examination of Cm in TRUEX and TALSPEAK, study U laser fluorescence, and apply project data to contactors. The team will also determine peak ratios as a function of solution concentrations for the UV-Visible spectroscopy studies. The use of TRLFS to examine Cm and U will provide data to evaluate lifetime, peak location, and peak ratios (mainly for U). The bases for the spectroscopic techniques have been investigated, providing fundamental evidence for the application’s utility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fundamental Studies of Fluid Mechanics: Stability in Porous Media

We summarize our research results in three main areas: coating flows; electrohydrodynamics of drops; and wetting and spreading of drops. Experimental, computational and analytical methods are used to address a variety of issues. Coating flow studies include the effect of roughness, surfactants, and adsorbed particles on the dynamics of dip-coating. Electrohydrodynamic studies include drop deformation in uniform electric fields, shape distortion due to charge convection in sedimenting drops, and driving chaotic advection by either an electric field inclined to the direction of drop motion or time-periodic changes in the direction of the electric field. Heat and mass transport from chaotically mixed droplets exhibit unexpected and remarkable increases in the rates of transport. Finally, we develop an analytical solution to the problem of a static droplet, and use numerical techniques to predict its migration due to surface tension gradients.

02 PETROLEUM↗

Surface deformation from a pressurized subsurface fracture: Problem description

This document speci es a set of problems that entail the calculation of ground surface deformation caused by a pressurized subsurface fracture. The solid medium is assumed to be isotropic-homogeneous where linear elasticity applies. The e ects of the uid in the fracture is represented by a uniform pressure applied onto the two fracture walls. The fracture is assumed to be rectangular in shape and various dipping angles are considered. In addition to the full 3D solution, we reduce the 3D problem to a plane-strain geometry, so that 2D codes can participate in the comparison and results can be compared with those available in the literature.

58 GEOSCIENCES↗

Moving to Sustainable Metals: Multifunctional Ligands in Catalytic, Outer Sphere C-H, N-H and O-H Activation

Much of our work during this grant period has emphasized green chemistry and sustainability. For example, we were able to convert glycerine, a waste byproduct of biodiesel production, into lactic acid, a compound with numerous applications, notably in the food and cosmetics industry, as well as being a source material for a biodegradable plastic. This work required a catalyst, that ceases to work after a certain lapse of time. We were able to identify the way in which this deactivation occurs by identifying some of the metal catalyst deactivation products. These proved to be multimetallic clusters containing up to six metals and up to 14 hydrogen atoms. Both the catalytic reaction itself and the deactivation structures are novel and unexpected. We have previously proposed that nitrogen heterocycles could be good energy carriers in a low CO 2 future world. In another part of our study, we found catalysts for introduction of hydrogen, an energy carrier that is hard to store, into nitrogen heterocycles. The mechanism of this process proved to be unusual in that the catalyst transfers the H 2 to the heterocycle in the form of H + and H - , first transferring the H + and only then the H - . In a third area of study, some of our compounds, originally prepared for DOE catalysis purposes, also proved useful in hydrocarbon oxidation and in water oxidation. The latter is important in solar-to-fuel work, because, by analogy with natural photosynthesis, the goal of the Yale Solar Group of four PIs is to convert sunlight to hydrogen and oxygen, which requires water splitting catalysts. The catalysts that proved useful mediate the latter reaction: water oxidation to oxygen. In a more technical study, we developed methods for distinguishing the case where catalysis is mediated by a soluble catalyst from cases where catalysis arises from a deposit of finely divided solid. One particular application involved electrocatalysis, where catalysis is driven by application of a voltage to electrodes dipped in the reactant mixture. We measured the mass increase of an electrode as material is deposited, and were able to see how this process is affected by the voltage supplied to the electrode. Our work continues to be well cited and we often receive requests for information or samples from fellow researchers.

08 HYDROGEN↗

Results of Hg Speciation Testing on 2Q15 Tank 50 and Tank 21 TCLP Extraction Fluid Samples and Tank 49 Material

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The sixth shipment of samples was designated to include SRNL Toxicity Characteristic Leaching Procedure (TCLP) extraction fluids from the 2Q15 Tank 50 and Tank 21 saltstone waste forms as well as Tank 49 material (HTF-49-15-45) collected on May 7, 2015. The TCLP extraction fluid samples were collected from duplicate extractions of two crushed saltstone fractions, one designated as “large” and one designated as “normal”. Both fractions of 2Q15 Tank 50 and Tank 21 saltstones (eight samples) were collected with the minimum possible free headspace and refrigerated prior to final dilution. The Tank 49 sample was left in its stainless steel dip bottle until it was opened and an aliquot diluted 1:100 with Eurofins deionized water on May 21, 2015. Following initial dilution in the Shielded Cells, the diluted Tank 49 sample was immediately moved to refrigeration and kept in the dark until prepared for shipment to Eurofins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Hg Speciation Testing on Tank 38 and 2H Evaporator Overhead Tank (OHT-1) Materials

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The seventh shipment of samples was designated to include two Tank 38 (2H Evaporator System Drop Tank) samples: a surface sample (HTF-38-15-48) and a variable depth sample taken at 265” (HTF-38-15-50). The third sample submitted was from the 2H Evaporator Overhead Tank (OHT) #1. All samples were received by SRNL on May 11, 2015. The OHT-1 was not placed in the SRNL Shielded Cells but was instead placed in a refrigerator in 773-A, B-wing upon receipt and kept at 4°C. The Tank 38 samples were left in their stainless steel dip bottles until they were opened and an aliquot of each diluted 1:10 with Eurofins deionized water on June 1, 2015. Following initial dilution in the Shielded Cells, the diluted Tank 38 samples were immediately moved to refrigeration and kept in the dark until prepared for shipment to Eurofins.

54 ENVIRONMENTAL SCIENCES↗

Results of HG Speciation Testing on Tank 43 and 2H Evaporator Overhead Tank (OHT-2) Materials

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The eighth shipment of samples was designated to include two Tank 43 (2H Evaporator System Feed Tank) samples: a surface sample (HTF-43-15-52) and a variable depth sample taken at 161” (HTF-43-15-54). The third sample submitted was from the 2H Evaporator Overhead Tank (OHT) #2. All samples were received by SRNL on May 11, 2015. The OHT-2 was not placed in the SRNL Shielded Cells but was instead placed in a refrigerator in 773-A, B-wing upon receipt and kept at 4°C. The Tank 43 samples were left in their stainless steel dip bottles until they were opened and an aliquot of each diluted 1:10 with Eurofins deionized water on June 3, 2015. Following initial dilution in the Shielded Cells, the diluted Tank 43 samples were immediately moved to refrigeration and kept in the dark until prepared for shipment to Eurofins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Targeted Technology Transfer to US Independents

The Petroleum Technology Transfer Council (PTTC) is a unique not-for-profit network that focuses on transferring Exploration and Production (E&P) technology to the domestic oil and natural gas producing industry. PTTC connects producers, technology providers and innovators, academia, research and development (R&D) consortiums and governments. Local affordable workshops delivered by Regional Lead Organizations (RLOs), which are typically a university or geological survey, are a primary tool. PTTC also maintains a website network, issues a national newsletter, provides a column in a major trade publication, and exhibits at major industry events. It also encourages industry to ask technology-related questions, striving to find relevant answers that will save questioners significant time. Working since late 1993, the PTTC network has a proven track record of providing industry with technology insights they can apply. Volunteers at the regional and national level provide key guidance regarding where to focus technical effort and help connect PTTC with industry. At historical funding levels, PTTC had been able to hold well more than 100 workshops per year, drawing 6,000+ attendees. As funding decreased in the early 2000s, the level of activity decreased and PTTC sought a merger with the American Association of Petroleum Geologists (AAPG), becoming an AAPG-managed organization at the start of FY08. This relationship with AAPG was terminated by mutual consent in May 2011 and PTTC once again operates independently. Chris Hall, California continued to serve as Chairman of the Board of Directors until December 2013. At the time PTTC reorganized into a RLO led organization with Mary Carr and Jeremy Viscomi as co-Executive Directors. Jerry Anderson became the Chairman of the PTTC Board of Directors and Chris Hall continues to serve on the Board. Workshop activity stabilized at 55-65 workshops per year averaging 3,100 attendees. FY14 represented the fifth year in a multi-year contract with the Department of Energy (DOE) for providing technology transfer services. This report summarizes activity and results during for five years, FY10 through FY14. In FY12 changes occurred in responsibilities of consultants serving HQ, because funding was reduced below the threshold level of $500,000 audits were no longer required and consultant time was reduced on the primary contract. Contracts for Permian Carbon Capture Utilization and Storage (CCUS) training, and providing tech transfer services to the Research Partnership to Secure Energy for America (RPSEA) provided work that enabled HQ to retain services of regular consultants. Both CCUS and RPSEA were five year contracts with PTTC, and providing services for these DOE funded contracts provided synergy for PTTC and the oil and gas industry. With further decreases in DOE funding the regions conducted workshops with no PTTC funding starting in June FY11. Since 2011 the number of workshops has declined from 79 in FY10 and FY11 to 49 in FY12, and risen to 54 in FY13 and 63 in FY14. The attendee's numbers dipped slightly below 3,000 per year in FY 10, FY12, and FY13, but rose to over 3,800 in FY 11 and 3105 in FY14. Quantitative accomplishments: PTTC has maintained its unique structure of a national organization working through Regional Lead Organizations (RLOs) to deliver local, affordable workshops. During the contract period PTTC consolidated from 10 to five regions to increase efficiency, and because no active RLO's would be maintained in the Central and Eastern Gulf Coast regions. RLO's for the regions are located at: Eastern - West Virginia University, (Illinois Geol. Survey., W. Michigan Univ. FY10-12); Midwest created in FY13 - Illinois Geological Survey, W. Michigan University; Midcontinent - University of Kansas, expanded to Houston, TX (2013-14); Rocky Mountain - Colorado School of Mines; Texas/SE New Mexico (FY10-FY11) - Bureau of Economic Geology, Univ. of Texas at Austin; West Coast - Conservation Committee of California O&G Producers.

02 PETROLEUM↗

Controls on methane expulsion during melting of natural gas hydrate systems. Topic area 2

1.1. Project Goal The project goal is to predict, given characteristic climate-induced temperature change scenarios, the conditions under which gas will be expelled from existing accumulations of gas hydrate into the shallow ocean or directly to the atmosphere. When those conditions are met, the fraction of the gas accumulation that escapes and the rate of escape shall be quantified. The predictions shall be applicable in Arctic regions and in gas hydrate systems at the up dip limit of the stability zone on continental margins. The behavior shall be explored in response to two warming scenarios: longer term change due to sea level rise (e.g. 20 thousand years) and shorter term due to atmospheric warming by anthropogenic forcing (decadal time scale). 1.2. Project Objectives During the first budget period, the objectives are to review and categorize the stability state of existing well-studied hydrate reservoirs, develop conceptual and numerical models of the melting process, and to design and conduct laboratory experiments that dissociate methane hydrate in a model sediment column by systematically controlling the temperature profile along the column. The final objective of the first budget period shall be to validate the models against the experiments. In the second budget period, the objectives are to develop a model of gas flow into sediment in which hydrate is thermodynamically stable, and conduct laboratory experiments of this process to validate the model. The developed models shall be used to quantify the rate and volume of gas that escapes from dissociating hydrate accumulations. In addition, specific scaled simulations characteristic of Arctic regions and regions near the stability limit at continental margins shall be performed. 1.3. Project Background and Rationale The central hypothesis proposed is that hydrate melting (dissociation) due to climate change generates free gas that can, under certain conditions, propagate through the gas hydrate stability zone and vent at the seafloor. Gas venting through the regional hydrate stability zone is accomplished by alteration of the regional equilibrium conditions (creation of three phase conditions) by increased salinity and heat due to hydrate formation, due to gas fracturing, or a combination of both. This research will explore the controls on whether methane reaches the seafloor (or atmosphere) as the original hydrate deposit dissociates and what the magnitude of these fluxes are. This hypothesis has significant implications for the forcings and feedbacks associated with climate change. It is described below the observations and models that have led to formulating this hypothesis.

03 NATURAL GAS↗

Assessment of Contaminated Brine Fate and Transport in MB139 at WIPP

Following the radionuclide release event of February 14, 2014 at the Waste Isolation Pilot Plant (WIPP), actinide contamination has been found on the walls and floor in Panel 7 as a result of a release in Room 7 of Panel 7. It has been proposed to decontaminate Panel 7 at the WIPP by washing contaminated surfaces in the underground with fresh water. A cost-effective cleanup of this contamination would allow for a timely return to waste disposal operations at WIPP. It is expected that the fresh water used to decontaminate Panel 7 will flow as contaminated brine down into the porosity of the materials under the floor – the run-of-mine (ROM) salt above Marker Bed 139 (MB139) and MB139 itself – where its fate will be controlled by the hydraulic and transport properties of MB139. Due to the structural dip of MB139, it is unlikely that this brine would migrate northward towards the Waste-Handling Shaft sump. A few strategically placed shallow small-diameter observation boreholes straddling MB139 would allow for monitoring the flow and fate of this brine after decontamination. Additionally, given that flow through the compacted ROM salt floor and in MB139 would occur under unsaturated (or two-phase) conditions, there is a need to measure the unsaturated flow properties of crushed WIPP salt and salt from the disturbed rock zone (DRZ).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a low cost method to estimate the seismic signature of a geothermal field form ambient noise analysis.

A new, cost effective and non-invasive exploration method using ambient seismic noise has been tested at Soda Lake, NV, with promising results. The material included in this report demonstrates that, with the advantage of initial S-velocity models estimated from ambient noise surface waves, the seismic reflection survey, although with lower resolution, reproduces the results of the active survey when the ambient seismic noise is not contaminated by strong cultural noise. Ambient noise resolution is less at depth (below 1000m) compared to the active survey. In general, the results are promising and useful information can be recovered from ambient seismic noise, including dipping features and fault locations.

15 GEOTHERMAL ENERGY↗

Investigating the Influence of Regional Stress on Fault and Fracture Permeability at Pahute Mesa, Nevada National Security Site

Regional stress may exert considerable control on the permeability and hydraulic function (i.e., barrier to and/or conduit for fluid flow) of faults and fractures at Pahute Mesa, Nevada National Security Site (NNSS). In-situ measurements of the stress field are sparse in this area, and short period earthquake focal mechanisms are used to delineate principal horizontal stress orientations. Stress field inversion solutions to earthquake focal mechanisms indicate that Pahute Mesa is located within a transtensional faulting regime, represented by oblique slip on steeply dipping normal fault structures, with maximum horizontal stress ranging from N29°E to N63°E and average of N42°E. Average horizontal stress directions are in general agreement with large diameter borehole breakouts from Pahute Mesa analyzed in this study and with stress measurements from other locations on the NNSS.

54 ENVIRONMENTAL SCIENCES↗

Layer-by-layer deposition of ultra-thin hybrid/microporous membrane for CO 2 separation

Based on two issued US patent, US7947579B2 and US8187678B2 that were invented by our team member at the University of New Mexico and Sandia National Labs, using atomic layer deposition technique (ALD) and molecular self-assembly or templating technique, An ultra-thin CO 2 membrane with CO 2 permeance up to 1580 GPU and CO 2 /N 2 up to 62 has been achieved in phase I project, promising for cost-effective CO 2 separations. As the first step of the project, a robust membrane fabrication protocol was established. To address the defects in the membrane structure, ALD treatment on AO support, multiple dip-coating processes and slow calcination steps were adopted. Consequently, defects were no longer evident in the nanoporous support, which ensures a reliable procedure for lab-scale membrane fabrications as well as the high-fidelity experimental findings. The same procedures may also be helpful for future scaling-up protocols. The layer-by-layer membrane fabrication was started by using a bridged disilane BTEE as the ALD precursor, wherein the organic groups at the bridging site were expected to be aligned layer-by-layer to form Angstrom-channels for CO 2 transport. Using 2-level factorial experimental design, we have found that ALD reaction time and ALD temperature were important factors impacting the CO 2 permeance and selectivity. Longer reaction time and higher ALD temperature were found to be advantageous for better CO 2 permeance and selectivity, which is in agreement with our model that better-aligned CO 2 -channels formed by the layer-by-layer stacking of the organic ligands can be achieved by a slower “stacking” process (longer reaction time) and stronger self-alignment tendency (higher ALD temperature). This observation will be an important guidance for our future membrane designs. The CO 2 -channel templated by –(CH 2 ) 2 - in BTEE was found to be too tight to facilitate fast CO 2 transport, but larger channel diameter is in contradiction with higher CO 2 selectivity. Therefore, the size-exclusion mechanism by itself is not sufficient for effective CO 2 separation. For this reason, the chemistry of the CO 2 -channel has to be carefully tuned. An amine bridged-disilane BTMA was therefore used as ALD precursor for larger CO 2 channel and high CO 2 -affinity chemistry. For BMTA membrane with amine chemistry measured at 100C, the CO 2 permeance was 1030 GPU for 100-cycle-ALD sample with CO 2 /N 2 selectivity of 17, and 302 GPU for 200-cycle-ALD sample with CO 2 /N 2 selectivity of 44. The increase of CO 2 permeance and the CO 2 /N 2 selectivity at elevated temperature is an evidence showing that there is a preferential chemical interaction between CO 2 and –NH functional groups in the membrane, which facilitates selective transport of CO 2 through the membrane. Therefore, using larger organic ligands as the CO 2 -channel template and the introduction of –NH chemistry to the membrane structure were proved to be an effective strategy in achieving better CO 2 permeance and selectivity. Guided by the same strategy, BTMA membrane was irradiated with UV to remove the bridging ligands for larger CO-channel, followed by Zn 2+ and Ni 2+ chemistry modification. Results showed that Zn 2+ or Ni 2+ chemistries will both enhance the selective CO 2 transport thereby the CO 2 /N 2 selectivity, and increasing separation temperature will further improve the CO2 permeance and selectivity. For BTMA membrane with Ni 2+ chemistry measured at 100C, CO 2 permeance of 1580 GPU and CO 2 /N 2 of 62 were achieved, promising for scaled-up industrial applications. Further, same membrane was tested at simulated flue gas condition (with SO 2 at 60C), the CO 2 permeance was 920 GPU and the CO 2 /N 2 selectivity was 52, suggesting the membrane still worked well under simulated flue gas conditions, primarily due to the stable ceramic framework of this membrane.

36 MATERIALS SCIENCE↗

Slippery Omniphobic Covalently Attached Liquids for Extreme Anti-Scaling

Fouling is amajor unresolved problem in a varietyof industries including power generation, water desalination,and hydrometallurgy. In a heat exchanger, the accumulated salt scale could lead to a decrease in heat transfer, corrosion, blockage of flow and increasedpressure drop, resulting in higher operation costsand shortened equipment lifetime. The added operational costs due to active scale removal techniques such as mechanical abrasion and chemical inhibitors are responsible for 0.25% of the GDP in industrialized nations.Herewe utilize slippery omniphobic covalently attached liquids (SOCAL) dip coating on aluminum substrates to minimize surface energyand surface roughness, hence maximizingthe energy barrier for scale formation. To enable SOCAL surfacebinding on aluminum, we started by depositinga nanoscale(500 nm thick)adhesion layer of SiO2using scalable and cost-effective electrophoretic deposition (EPD), followed by SOCAL grafting to the SiO2.The EPD SiO2coating chemistry was tailored to achieve a smoothsurface finish which, combined with the low surface energyof the SOCAL coating, translated to extreme anti-scaling performance. Thermal degradation testing in an ambient environment revealed the covalently bonded SOCAL coatingswithstand temperatures of 100°C. To characterize scaling, we utilized CaSO4and CaCO3scale tests, showing up to 20X less scaling than uncoated aluminum. Descaling tests revealed that our SOCAL coatings dramatically decrease scale adhesion, resulting in rapid removal of scale buildup in highly supersaturated conditions. To investigate manufacturability, two alternate methods of SiO2deposition were tested, including physical vapor deposition and spin-on glass, with great success in coating smooth metallic substrates, but limited success due to the inability to coat arbitrarily shaped surfaces. Our work not only demonstrates a facile method of tailoring interfacial energy and roughness to control fouling, it develops cost-effective, scalable,and high performing anti-fouling coating applicable to aluminum surfacesfor a variety of applications.

Zhao, Hanyang↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodologies for Evaluation of Corrosion Protection for Ductile Iron Pipe

Repairing the nation’s infrastructure and ensuring its future durability are key issues facing the United States. It is important that these critical issues are addressed with appropriate and economical solutions based on the best modern scientific information. For example, in 2013 the American Society of Civil Engineers (ASCE), in its Report Card for America’s Infrastructure, gave the state of the critical water/wastewater infrastructure an overall grade of “D.” According to the ASCE, 6 billion gallons of drinking water disappear every day, mostly due to leaks in old pipes. Corrosion of water pipes plays a role in their durability and, for external pipe corrosion, the corrosivity of soils varies by location and is based on several factors, including soil resistivity. There is universal agreement that water pipes require some type of corrosion mitigation strategy (i.e., bare pipe is not installed). However, in specifying which strategy to employ for ductile iron pipe (DIP) in different soil types, the recommendations of the US Bureau of Reclamation (USBR) Technical Memorandum 8140-CC-2004-1 were subject to considerable debate. So much so that in 2009, this report was the subject of a study by the National Academy, which did not resolve the debate about the most effective and affordable solutions. Zinc-coatings have been explored in other parts of the world. Despite being widely used in Europe for almost 60 years, zinc coating was barely mentioned in either the 2004 or 2009 studies, which appeared to focus on North American data.

36 MATERIALS SCIENCE↗

Comparative Analysis of Transport and Storage Options from a CO 2 Source Perspective

This analysis evaluated integrated CCS costs (i.e., capture, transport, and storage) from the perspective of a CO 2 source. Capture costs for sources with annual CO 2 capture rates from 0.65 to 3.90 Mt were based on two NETL reports. Transportation costs from source to storage reservoir were modeled for two pipelines systems (dedicated and trunkline) using the FE/NETL CO 2 Transport Cost Model. Storage costs were modeled in dome and regional dip structural settings for two reservoirs in the Rose Run Formation, three within the Mt. Simon, one in the Lower Tuscaloosa, and one in the Frio using the FE/NETL CO 2 Saline Storage Cost Model. A paper with the same name and information as well as additional details on this analysis was published in The International Journal of Greenhouse Gas Control along with a supplementary document that provides additional material (i.e., key parameters used in the models for obtaining transport and storage costs and CCS cost and pipeline results).

03 NATURAL GAS↗