Towards understanding HPC users and systems: A NERSC case study

High performance computing (HPC) scheduling landscape currently faces new challenges due to thechanges in the workload. Previously, HPC centers were dominated by tightly coupled MPI jobs. HPCworkloads increasingly include high-throughput, data-intensive, and stream-processing applications. Asa consequence, workloads are becoming more diverse at both application and job levels, posing newchallenges to classical HPC schedulers. There is a need to understand the current HPC workloads andtheir evolution to facilitate informed future scheduling research and enable efficient scheduling in futureHPC systems.In this paper, we present a methodology to characterize workloads and assess their heterogeneity,at a particular time period and its evolution over time. We apply this methodology to the workloads ofthree systems (Hopper, Edison, and Carver) at the National Energy Research Scientific Computing Center(NERSC). We present the resulting characterization of jobs, queues, heterogeneity, and performance thatincludes detailed information of a year of workload (2014) and evolution through the systems’ lifetime(2010–2014).

Rodrigo, Gonzalo P.↗

Thermal and Thermoelectric Properties of Molecular Junctions

Abstract Molecular junctions (MJs) represent an ideal platform for studying charge and energy transport at the atomic and molecular scale and are of fundamental interest for the development of molecular‐scale electronics. While tremendous efforts have been devoted to probing charge transport in MJs during the past two decades, only recently advances in experimental techniques and computational tools have made it possible to precisely characterize how heat is transported, dissipated, and converted in MJs. This progress is central to the design of thermally robust molecular circuits and high‐efficiency energy conversion devices. In addition, thermal and thermoelectric studies on MJs offer unique opportunities to test the validity of classical physical laws at the nanoscale. A brief survey of recent progress and emerging experimental approaches in probing thermal and thermoelectric transport in MJs is provided, including thermal conduction, heat dissipation, and thermoelectric effects, from both a theoretical and experimental perspective. Future directions and outstanding challenges in the field are also discussed.

Wang, Kun↗

LHC EFT WG note: SMEFT predictions, event reweighting, and simulation

This note provides a comprehensive overview of tools for predicting observables in the Standard Model effective field theory (SMEFT) at both tree level and one loop using event generators. We evaluate three primary methodologies–event reweighting, separate simulation of squared matrix elements, and full SMEFT process simulation–focusing on their statistical performance, computational efficiency, and potential biases. Each approach is assessed in terms of its accuracy, highlighting trade-offs between precision and resource demands. Practical insights into their applicability for high-energy physics analyses are offered, with particular attention to processes where SMEFT effects are significant. Additionally, we discuss the role of helicity in reweighting strategies and its impact on the quality of predictions. By comparing the methods across various LHC processes, this note provides guidance for selecting the most effective strategy for various SMEFT studies, ensuring robust predictions while optimizing computational resources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ANSI/ASHRAE/IES Standard 90.1-2010 Final Determination Quantitative Analysis

The U.S. Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society (IES) Standard 90.1-2010 (ASHRAE Standard 90.1-2010, Standard 90.1-2010, or 2010 edition) would result in energy savings compared with buildings constructed to ANSI/ASHRAE/Illuminating Engineering Society of North America (IESNA) Standard 90.1- 2007(ASHRAE Standard 90.1-2007, Standard 90.1-2007, or 2007 edition). The final analysis considered each of the 109 addenda to ASHRAE Standard 90.1-2007 that were included in ASHRAE Standard 90.1- 2010. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were reviewed by DOE, and their combined impact on a suite of 16 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s final determination. However, out of the 109 addenda, 34 were preliminarily determined to have a measureable and quantifiable impact. A suite of 240 computer energy simulations for building prototypes complying with ASHRAE 90.1- 2007 was developed. These prototypes were then modified in accordance with these 34 addenda to create a second suite of corresponding building simulations reflecting the same buildings compliant with Standard 90.1-2010. The building simulations were conducted using the DOE EnergyPlus building simulation software. The resulting energy use from the complete suite of 480 simulation runs was then converted to energy use intensity (EUI, or energy use per unit floor area) metrics (Site EUI, Primary EUI, and energy cost intensity [ECI]) results for each simulation. For each edition of the standard, these EUIs were then aggregated to a national basis for each prototype using weighting factors based on construction floor area developed for each of the 15 U.S. climate zones using commercial construction data. When compared, the resulting weighted EUIs indicated that each of the 16 building prototypes used less energy under Standard 90.1-2010 than under Standard 90.1-2007 on a national basis when considering site energy, primary energy, or energy cost. The EUIs were also aggregated across building types to a national commercial building basis using the same weighting data. On a national basis, the final quantitative analysis estimated a floor-space-weighted national average reduction in new building energy consumption of 18.2 percent for source energy and 18.5 percent when considering site energy. An 18.2 percent savings in energy cost, based on national average commercial energy costs for electricity and natural gas, was also estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Searching for Physics Beyond the Standard Model: Strongly-Coupled Field Theories at the Intensity and Energy Frontiers

This proposal is to develop the software and algorithmic infrastructure needed for the numerical study of quantum chromodynamics (QCD), and of theories that have been proposed to describe physics beyond the Standard Model (BSM) of high energy physics, on current and future computers. This infrastructure will enable users (1) to improve the accuracy of QCD calculations to the point where they no longer limit what can be learned from high-precision experiments that seek to test the Standard Model, and (2) to determine the predictions of BSM theories in order to understand which of them are consistent with the data that will soon be available from the LHC. Work will include the extension and optimizations of community codes for the next generation of leadership class computers, the IBM Blue Gene/Q and the Cray XE/XK, and for the dedicated hardware funded for our field by the Department of Energy. Members of our collaboration at Brookhaven National Laboratory and Columbia University worked on the design of the Blue Gene/Q, and have begun to develop software for it. Under this grant we will build upon their experience to produce high-efficiency production codes for this machine. Cray XE/XK computers with many thousands of GPU accelerators will soon be available, and the dedicated commodity clusters we obtain with DOE funding include growing numbers of GPUs. We will work with our partners in NVIDIA's Emerging Technology group to scale our existing software to thousands of GPUs, and to produce highly efficient production codes for these machines. Work under this grant will also include the development of new algorithms for the effective use of heterogeneous computers, and their integration into our codes. It will include improvements of Krylov solvers and the development of new multigrid methods in collaboration with members of the FASTMath SciDAC Institute, using their HYPRE framework, as well as work on improved symplectic integrators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heterogeneous processes at the intersection of chemistry and biology: A computational approach

Heterogeneous processes hold the key to understanding many problems in biology and atmospheric science. In particular, recent experiments have shown that heterogeneous chemistry at the surface of sea-salt aerosols plays a large role in important atmospheric processes with far reaching implications towards understanding of the fate and transport of aerosolized chemical weapons (i.e. organophosphates such as sarin and VX). Unfortunately, the precise mechanistic details of the simplest surface enhanced chemical reactions remain unknown. Understanding heterogeneous processes also has implications in the biological sciences. Traditionally, it is accepted that enzymes catalyze reactions by stabilizing the transition state, thereby lowering the free energy barrier. However, recent findings have shown that a multitude of phenomena likely contribute to the efficiency of enzymes, such as coupled protein motion, quantum mechanical tunneling, or strong electrostatic binding. The objective of this project was to develop and validate a single computational framework based on first principles simulations using tera-scale computational resources to answer fundamental scientific questions about heterogeneous chemical processes relevant to atmospheric chemistry and biological sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient Signal Processing in BOTDA: Utilizing PCA and PCA-Based Neural Networks for Temperature Monitoring

This work presents a comparative analysis of the various signal processing techniques used in the Brillouin gain spectrum (BGS) peak estimation. Traditional fitting methods such as Lorentzian curve fitting (LCF) are slow and less effective in noisy data. PCA-based methods were tested on the experimental data: A Euclidian distance-based approach, and a probabilistic deep neural network (PDNN) based approach, both using 5 principal components to represent a single BGS. Both methods significantly reduce computational time with respect to LCF, whereas PDNN offers uncertainty insights along with the parameter value. Measuring a range of temperatures, analyzing accuracy, and speed, it can be concluded that PCA trained PDNN outperforms other methods, and appears to be helpful in scenario where large datasets are generated.

Brillouin optical time domain analysis↗

Heterogeneous Computing

To leverage the increasing heterogeneity in modern computing resources, Geant4 incorporates advanced software tools and a task-based framework (G4Tasking) that enables efficient parallelism at event, sub-event, and track levels. Ongoing R&D efforts focus on integrating GPUs into high-energy physics (HEP) simulations, including optical photon simulation with Opticks/NVIDIA OptiX, offloading electromagnetic particle transport using G4HepEM/AdePT and Celeritas, and employing advanced surface-based geometry models such as VecGeom2.0 and ORANGE. As Geant4 continues evolving toward high-performance computing (HPC) and heterogeneous architectures, it remains a key tool for large-scale simulations in HEP and beyond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A rare terminal dinitrogen complex of chromium

Cis and trans-Cr–N₂ complexes supported by the diphosphine ligand P{sup Ph}₂N{sup Bn}₂ have been prepared. Positioned pendant amines in the second coordination sphere influence the thermodynamically preferred geometric isomer. Electronic structure calculations indicate negligible Cr–N₂ back-bonding; rather, electronic polarization of N₂ ligand is thought to stabilize Cr–N₂ binding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FFT, FMM, and multigrid on the road to exascale: Performance challenges and opportunities

FFT, FMM, and multigrid methods are widely used fast and highly scalable solvers for elliptic PDEs. However, emerging large-scale computing systems are introducing challenges in comparison to current petascale computers. Recent efforts (Dongarra et al. 2011) have identified several constraints in the design of exascale software that include massive concurrency, resilience management, exploiting the high performance of heterogeneous systems, energy efficiency, and utilizing the deeper and more complex memory hierarchy expected at exascale. In this paper, we perform a model-based comparison of the FFT, FMM, and multigrid methods in the context of these projected constraints. Finally, we use performance models to offer predictions about the expected performance on upcoming exascale system configurations based on current technology trends.

97 MATHEMATICS AND COMPUTING↗

Resilience Evaluation and Enhancement for Island City Integrated Energy Systems

Extreme natural hazards, such as hurricanes or earthquakes, have a high probability of threatening energy supply security and causing high-order contingencies to island city-integrated energy systems (IC-IESs). To better evaluate and enhance resilience, a novel approach is proposed in this work for IC-IESs. The resilience of an IC-IES is analyzed from both the system level and the component level. At the system level, the impacts of extreme natural disasters are quantified. At the component level, the importance of individual components is analyzed through pre-failure and post-failure indices. The pre-failure index identifies the system’s weak links before an energy interruption, and the post-failure index determines the optimal repair strategy to restore the service. The proposed indices are solved by the impact increment method (IIM), which significantly improves computational efficiency without much affecting result accuracy. Numerical simulation studies are conducted on the modified Barry Island IES and IES E123-G48-H32 test systems. Furthermore, the results validate the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance evaluation of radiant cooling system integrated with air system under different operational strategies

The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building using a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Center Energy Efficiency Measurement Assessment Kit Guide and Specification

A portable and temporary wireless mesh assessment kit can be used to speed up and reduce the costs of a data center energy use assessment and overcome the issues with respect to shutdowns. The assessment kit is comprised of temperature, relative humidity, and pressure sensors. Also included are power meters that can be installed on computer room air conditioners (CRACs) without intrusive interruption of data center operations. The assessment kit produces data required for a detailed energy assessment of the data center.

Data, Center, Energy, Efficiency, Measurement, Ass↗

Quantifying Uncertainty in PV Energy Estimates Final Report

Uncertainty in PV energy estimates is "one of the most critical areas of lack of understanding" according to independent engineers, financiers, PV model developers, and other industry stakeholders. The primary problem is a lack of rigorous, transparent, widely accepted methods for quantifying uncertainty in energy production estimates. Uncertainty in energy production estimates arises from variability of the solar resource, inexact PV performance models and their parameters, and system reliability considerations. Uncertainty in annual energy production is frequently calculated for larger projects in order to quantify financial risk. Key statistics for energy, such as the P-values "P50" and "P90" (the annual energy values that are exceeded in future years with 50\% and 90\% probability, respectively) are used by financing institutions to calculate the repayment risk for the project. The current methods to estimate these statistics are typically proprietary, specialized, and involve significant post-processing of commercial performance model results. This black-box approach leads to inconsistent P-value estimates from different parties, which reduces investors' confidence in the results. Since the financial community bases its risk assessment on these estimates, reduced confidence increases perceived project risk, and consequently financing costs. The goal of this project was to establish a set of best practices for quantifying uncertainty in energy production estimates, including identifying what sources of uncertainty must be considered with clear definitions and metrics, determining which sources are the biggest drivers of uncertainty, and providing a computationally efficient framework for combining different sources of uncertainty that is flexible enough to accommodate substitutions of data or methods when better information is available. We engaged a wide set of stakeholders to ensure industry endorsement and adoption, and leveraged complementary projects investigating individual sources of uncertainty in great detail, as well as others' work that started down this path.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

A Component-Sizing Methodology for a Hybrid Electric Vehicle Using an Optimization Algorithm

Many leading companies in the automotive industry have been putting tremendous effort into developing new powertrains and technologies to make their products more energy efficient. Evaluating the fuel economy benefit of a new technology in specific powertrain systems is straightforward; and, in an early concept phase, obtaining a projection of energy efficiency benefits from new technologies is extremely useful. However, when carmakers consider new technology or powertrain configurations, they must deal with a trade-off problem involving factors such as energy efficiency and performance, because of the complexities of sizing a vehicle’s powertrain components, which directly affect its energy efficiency and dynamic performance. As powertrains of modern vehicles become more complicated, even more effort is required to design the size of each component. This study presents a component-sizing process based on the forward-looking vehicle simulator “Autonomie” and the optimization algorithm “POUNDERS”; the supervisory control strategy based on Pontryagin’s Minimum Principle (PMP) assures sufficient computational system efficiency. We tested the process by applying it to a single power-split hybrid electric vehicle to determine optimal values of gear ratios and each component size, where we defined the optimization problem as minimizing energy consumption when the vehicle’s dynamic performance is given as a performance constraint. The suggested sizing process will be helpful in determining optimal component sizes for vehicle powertrain to maximize fuel efficiency while dynamic performance is satisfied. Indeed, this process does not require the engineer’s intuition or rules based on heuristics required in the rule-based process.

33 ADVANCED PROPULSION SYSTEMS↗

Computer simulation of the energy gap in ZnO- and TiO{sub 2}-based semiconductor photocatalysts

Ab initio calculations of the electronic structures of binary ZnO- and TiO{sub 2}-based oxides are performed to search for optimum dopants for efficient absorption of the visible part of solar radiation. Light elements B, C, and N are chosen for anion substitution. Cation substitution is simulated by 3d elements (Cr, Mn, Fe, Co) and heavy metals (Sn, Sb, Pb, Bi). The electronic structures are calculated by the full-potential linearized augmented plane wave method using the modified Becke-Johnson exchange-correlation potential. Doping is simulated by calculating supercells Zn{sub 15}D{sub 1}O{sub 16}, Zn{sub 16}O{sub 15}D{sub 1}, Ti{sub 15}D{sub 1}O{sub 32}, and Ti{sub 8}O{sub 15}D{sub 1}, where one-sixteenth of the metal (Ti, Zn) or oxygen atoms is replaced by dopant atoms. Carbon and antimony are found to be most effective dopants for ZnO: they form an energy gap {Delta}E = 1.78 and 1.67 eV, respectively. For TiO{sub 2}, nitrogen is the most effective dopant ({Delta}E = 1.76 eV).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Seizure control with thermal energy? Modeling of heat diffusivity in brain tissue and computer-based design of a prototype mini-cooler.

Automated seizure blockage is a top priority in epileptology. Lowering nervous tissue temperature below a certain level suppresses abnormal neuronal activity, an approach with certain advantages over electrical stimulation, the preferred investigational therapy for pharmacoresistant seizures. A computer model was developed to identify an efficient probe design and parameters that would allow cooling of brain tissue by no less than 21 C in 30 s, maximum. The Pennes equation and the computer code ABAQUS were used to investigate the spatiotemporal behavior of heat diffusivity in brain tissue. Arrays of distributed probes deliver sufficient thermal energy to decrease, inhomogeneously, brain tissue temperature from 37 to 20 C in 30 s and from 37 to 15 C in 60 s. Tissue disruption/loss caused by insertion of this probe is considerably less than that caused by ablative surgery. This model may be applied for the design and development of cooling devices for seizure control.

60 APPLIED LIFE SCIENCES↗