Simulation of the J-2 engine gimbal bearing
Phenol resin bonded, woven glass and Teflon fiber lubricant for J-2 rocket engine gimbal system
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Phenol resin bonded, woven glass and Teflon fiber lubricant for J-2 rocket engine gimbal system
Flow characteristics of curved porous wall gas core reactors for nuclear rocket engines, visualizing simulated fuel flow with air-smoke combination
Determination of low speed jet noise from fan engine for simulated nacelle configuration
Predicting performance of Chamber solar simulator using D chamber xenon source module
A description of the performance test to compare noise output from a quiet engine with acoustic nacelle to the noise output of the JT3D turbofan engine is presented. Tabulations depict comparative thrusts, bypass ratios, core jet velocities, and fan jet velocities for both engines during simulated takeoff and approach performances.
An investigation of the static longitudinal aerodynamic characteristics of a semispan STOL jet transport wing-body with an upper-surface blown jet flap for lift augmentation was conducted in a low-speed wind tunnel having a 12-ft octagonal test section. The semispan swept wing had an aspect ratio of 3.92 (7.84 for the full span) and had two simulated turbofan engines mounted ahead of and above the wing in a siamese pod equipped with an exhaust deflector. The purpose of the deflector was to spread the engine exhaust into a jet sheet attached to the upper surface of the wing so that it would turn downward over the flap and provide lift augmentation. The wing also had optional boundary-layer control provided by air blowing through a thin slot over a full-span plain trailing-edge flap.
An investigation of the static longitudinal aerodynamic characteristics of a large-scale semispan model with an unswept wing and an upper-surface blown jet flap for lift augmentation was conducted in the Langley full-scale tunnel. The wing had an aspect ratio of 7.8 (3.9 for the semispan) and a simulated turbofan engine mounted ahead of and above the wing in a nacelle with a rectangular-exit nozzle. The flap system had three spanwise flap segments: (1) an inboard plain flap located behind the engine and having a large radius of curvature to provide a smooth upper surface to enhance the turning of the jet sheet, (2) a double-slotted midspan flap, and (3) a drooped aileron equipped with blowing boundary-layer control. The wing was also equipped with a full-span leading-edge Krueger flap with blowing boundary-layer control. In addition to the aerodynamic measurements, noise measurements were also included in the investigation for positions above and below the wing.
Explore the source record for details and available documents.
The primary test objective was to define the base pressure environment of the first and second stage mated vehicle in a supersonic flow field from Mach 2.60 through 3.50 with simulated rocket engine exhaust plumes. The secondary objective was to obtain the pressure environment of the Orbiter at various vent port locations at these same freestream conditions. Data were obtained at angles of attack from -4 deg through +4 deg at zero yaw, and at yaw angles from -4 deg through +4 deg at zero angle of attack, with rocket plume sizes varying from smaller than nominal to much greater than nominal. Failed Orbiter engine data were also obtained. Elevon hinge moments and wing panel load data were obtained during all runs. Photographs of test equipment and tested configurations are shown.
An extended mission was conducted to perform experiments demonstrating increased operational capabilities. The Centaur propellant behavior, the effects of reduced tank pressurization levels, and a propellant duct prechill technique were successfully evaluated. The major flight data results show that: (1) the propellants can be controlled with short collection times, even with a simulated H202 engine failure; (2) extensive tank ventings can be safely performed; (3) the Centaur boost pumps can perform adequately with no LH2 tank pressurization, and with low LO2 tank pressurization levels; (4) the duct prechill technique is an effective way to reduce boost pump cavitation and improve engine chilldown; and (5) the Centaur boost pumps should be completely stopped prior to an engine start sequence.
The Approach and Landing Test Program consisted of a series of steps leading to the demonstration of the capability of the Space Shuttle orbiter to safely approach and land under conditions similar to those planned for the final phases of an orbital flight. The tests were conducted with the orbiter mounted on top of a specially modified carrier aircraft. The first step provided airworthiness and performance verification of the carrier aircraft after modification. The second step consisted of three taxi tests and five flight tests with an inert unmanned orbiter. The third step consisted of three mated tests with an active manned orbiter. The fourth step consisted of five flights in which the orbiter was separated from the carrier aircraft. For the final two flights, the orbiter tail cone was replaced by dummy engines to simulate the actual orbital configuration. Landing gear braking and steering tests were accomplished during rollouts following the free flight landings. Ferry testing was integrated into the Approach and Landing Test Program to the extent possible. In addition, four ferry test flights were conducted with the orbiter mated to the carrier aircraft in the ferry configuration after the free-flight tests were completed.
A review is conducted of the additional test facilities required in connection with the National Aeronautical Facilities Program and of other new propulsion test facilities. Attention is given to the National Transonic Facility, the AMES wind tunnel, the Turbine Engine Load Simulator, facilities for the conduction of compressor research, a fuels and lubricants laboratory, and test facilities in the UK, France, and Germany. It is pointed out that there is a need for government and industry to support the facility investment necessary to make progress in aerospace technology. Aspects of international cooperation are also discussed.
The JT9D-70/59 high pressure turbine active clearance control system was modified to provide reduction of blade tip clearance when the system is activated during cruise operation. The modification increased the flow capacity and air impingement effectiveness of the cooling air manifold to augment turbine case shrinkage capability, and increased responsiveness of the airseal clearance to case shrinkage. The simulated altitude engine testing indicated a significant improvement in specific fuel consumption with the modified system. A 1000 cycle engine endurance test showed no unusual wear or performance deterioration effects on the engine or the clearance control system. Rig tests indicated that the air impingement and seal support configurations used in the engine tests are near optimum.
Progress in the development of a performance optimized engine system design for an advanced LOX/hydrogen expander cycle engine is reported. Analysis of the components and engine and the resulting drawings is discussed. The status of the orbit transfer vehicle liquid engine transient simulation computer model is given.
Five levels of autopilot complexity were flown in a single engine IFR simulation for several different IFR terminal operations. A comparison was made of the five levels of complexity ranging from no-autopilot to a fully coupled lateral and vertical guidance mode to determine the relative benefits vs. complexity/cost of state-of-the-art autopilot capability in the IFR terminal area. For the levels of progression tested, the heading select mode made the largest difference in decreasing workload and simplifying the approach task. It was also found that the largest number of blunders was detected with the most fully automated mode. The data also showed that, regardless of the autopilot mode, performance during an IFR approach was highly dependent on the type of approach being flown. These results indicate that some level of automation is desirable when making IFR approaches in a high workload environment, but also that some disturbing trends are associated with the higher levels of automation.
Wind tunnel tests were conducted to evaluate the aerodynamic performance of a coannular exhaust nozzle for a proposed variable stream control supersonic propulsion system. Tests were conducted with two simulated configurations differing primarily in the fan duct flowpaths: a short flap mechanism for fan stream control with an isentropic contoured flow splitter, and an iris fan nozzle with a conical flow splitter. Both designs feature a translating primary plug and an auxiliary inlet ejector. Tests were conducted at takeoff and simulated cruise conditions. Data were acquired at Mach numbers of 0, 0.36, 0.9, and 2.0 for a wide range of nozzle operating conditions. At simulated supersonic cruise, both configurations demonstrated good performance, comparable to levels assumed in earlier advanced supersonic propulsion studies. However, at subsonic cruise, both configurations exhibited performance that was 6 to 7.5 percent less than the study assumptions. At take off conditions, the iris configuration performance approached the assumed levels, while the short flap design was 4 to 6 percent less.
The design layouts and detailed design drawings of coannular exhaust nozzle models for a supersonic propulsion system are presented. The layout drawings show the assembly of the component parts for each configuration. A listing of the component parts is also given.
Tabulated data from wind tunnel tests conducted to evaluate the aerodynamic performance of an advanced coannular exhaust nozzle for a future supersonic propulsion system are presented. Tests were conducted with two test configurations: (1) a short flap mechanism for fan stream control with an isentropic contoured flow splitter, and (2) an iris fan nozzle with a conical flow splitter. Both designs feature a translating primary plug and an auxiliary inlet ejector. Tests were conducted at takeoff and simulated cruise conditions. Data were acquired at Mach numbers of 0, 0.36, 0.9, and 2.0 for a wide range of nozzle operating conditions. At simulated supersonic cruise, both configurations demonstrated good performance, comparable to levels assumed in earlier advanced supersonic propulsion studies. However, at subsonic cruise, both configurations exhibited performance that was 6 to 7.5 percent less than the study assumptions. At takeoff conditions, the iris configuration performance approached the assumed levels, while the short flap design was 4 to 6 percent less. Data are provided through test run 25.