At least 1,297 records · Page 72

Effect of 730 °C Supercritical Fluid Exposure on the Fatigue Threshold of Ni-Based Superalloy Haynes 282

Driven by the need to reduce CO{sub 2} emissions from fossil power generation, new turbine working fluids are being investigated. One such fluid, supercritical carbon dioxide (sCO{sub 2}), offers potential for improved energy conversion efficiency. In situ corrosion studies on precipitate-hardened nickel superalloys in sCO{sub 2} have shown potentially dangerous subsurface depletion of gamma prime phase. In the present work, the ex situ effect of supercritical fluid exposure on fatigue crack growth thresholds was measured for the Ni-based superalloy Haynes 282. After exposure of 500 h at 730 °C, there was a small measurable and repeatable reduction in fatigue thresholds at room temperature from 13 to 11 MPa√m after exposure. This reduction in fatigue crack growth threshold occurred irrespective of the exposure environment and was attributed to a decrease in roughness-induced crack closure.

42 ENGINEERING↗

Viscosity Measurements at High Pressures: A Critical Appraisal of Corrections to Stokes' Law

Abstract Fluids and melts in planetary interiors significantly influence geodynamic processes from volcanism to global‐scale differentiation. The roles of these geofluids depend on their viscosities ( η ). Constraining geofluid η at relevant pressures and temperatures relies on laboratory‐based measurements and is most widely done using Stokes' Law viscometry with falling spheres. Yet small sample chambers required by high‐pressure experiments introduce significant drag on the spheres. Several correction schemes are available for Stokes' Law but there is no consensus on the best scheme(s) for high‐pressure experiments. We completed high‐pressure experiments to test the effects of (a) the relative size of the sphere diameter to the chamber diameter and (b) the top and bottom of the chamber, that is, the ends, on the sphere velocities. We examined the influence of current correction schemes on the estimated viscosity using Monte Carlo simulations. We also compared previous viscometry work on various geofluids in different experimental setups/geometries. We find the common schemes for Stokes' Law produce statistically distinct values of η . When inertia of the sphere is negligible, the most appropriate scheme may be the Faxén correction for the chamber walls. Correction for drag due to the chamber ends depends on the precision in the sinking distance and may be ineffective with decreasing sphere size. Combining the wall and end corrections may overcorrect η . We also suggest the uncertainty in η is best captured by the correction rather than propagated errors from experimental parameters. We develop an overlying view of Stokes' Law viscometry at high pressures.

Geochemistry & Geophysics↗

Scanning Laser Doppler Vibrometer Measurements Inside Helicopter Cabins in Running Conditions: Problems and Mock-up Testing

The present work deals with the analysis of problems and potentials of laser vibrometer measurements inside helicopter cabins in running conditions. The paper describes the results of a systematic measurement campaign performed on an Agusta A109MKII mock-up. The aim is to evaluate the applicability of Scanning Laser Doppler Vibrometer (SLDV) for tests in simulated flying conditions and to understand how performances of the technique are affected when the laser head is placed inside the cabin, thus being subjected to interfering inputs. Firstly a brief description of the performed test cases and the used measuring set-ups are given. Comparative tests between SLDV and accelerometers are presented, analyzing the achievable performances for the specific application. Results obtained measuring with SLDV placed inside the helicopter cabin during operative excitation conditions are compared with those performed with the laser lying outside the mock-up, these last being considered as 'reference measurements'. Finally, in order to give an estimate of the uncertainty level on measured signals, a study linking the admitted percentage of noise content on vibrometer signals due to laser head vibration levels will be introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the non-liquid-level-sensing temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode . a known function of the current and temperature . is measured as an indication of its temperature. For the purpose of this measurement, "small electric current" signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired locations along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode a known function of the current and temperature is measured as an indication of its temperature. For the purpose of this measurement, small electric current signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when the diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired location along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Anomalous normal fluid response in a chiral superconductor UTe2

Abstract Chiral superconductors have been proposed as one pathway to realize Majorana normal fluid at its boundary. However, the long-sought 2D and 3D chiral superconductors with edge and surface Majorana normal fluid are yet to be conclusively found. Here, we report evidence for a chiral spin-triplet pairing state of UTe 2 with surface normal fluid response. The microwave surface impedance of the UTe 2 crystal was measured and converted to complex conductivity, which is sensitive to both normal and superfluid responses. The anomalous residual normal fluid conductivity supports the presence of a significant normal fluid response. The superfluid conductivity follows the temperature behavior predicted for an axial spin-triplet state, which is further narrowed down to a chiral spin-triplet state with evidence of broken time-reversal symmetry. Further analysis excludes trivial origins for the observed normal fluid response. Our findings suggest that UTe 2 can be a new platform to study exotic topological excitations in higher dimension.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The development of new, low-cost perfluoroalkylether fluids with excellent low and high-temperature properties

A series of perfluoroalkylether (PFAE) fluids were synthesized by direct fluorination. Viscosity-temperature properties, oxidation stabilities, oxidation-corrosion properties, and lubricity were determined. The fluids were tested in the presence of common elastomers to check for compatibility. The bulk modulus of each was measured to determine if any could be used as nonflammable aircraft hydraulic fluid. It was determined that as the carbon to oxygen ratio decreases, the viscometric properties improve, the fluids may become poor lubricants, the bulk modulus increases, the surface tension increases, and the fluid density increases. The presence of difluoromethylene oxide units in the polymer does not seriously lower the oxidation and oxidation-corrosion stabilities as long as the difluoromethylene oxide units are separated by other units.

Bierschenk, Thomas R.↗

Particle image velocimetry

Particle imaging velocimetry, which is rapidly becoming an essential tool for the synoptic measurement of two dimensional velocity fields, is addressed. This rapid development is carried out by a growing number of fluid mechanics experimentalists who recognize the unique capabilities of the technique to measure velocity fields in both space and time, and is supported by the concomitant development and availability of microcomputer hardware and software. Various applications of the technique to map different flow regimes are described and illustrated. Hardware implementations of the technique which utilize both conventional photography for image acquisition as well as digital 'online' methods for integrated image acquisition and processing are discussed. Recommendations to further enhance the technique and make it possible to map the three velocity components in three dimensional flow regions are given.

Lourenco, L. M.↗

The fluid dynamic and shear environment in the NASA/JSC rotating-wall perfused-vessel bioreactor

The rotating-wall perfused-vessel (RWPV) bioreactor, used for both microgravity and Earth-based cell science experiments, is characterized in terms of the fluid dynamic and fluid shear stress environment. A numerical model of the flow field is developed and verified with laser Doppler velocimeter measurements. The effects of changes in operating conditions, including rotation rates and fluid perfusion rates, are investigated with the numerical model. The operating conditions typically used for ground-based experiments (equal rotation of the inner and outer cylinders) leads to flow patterns with relatively poor mass distribution characteristics. Approximately 50% of the inlet-perfused fluid bypasses the bulk of the fluid volume and flows to the perfusion exit. For operating conditions typical in microgravity, small differential rotation rates between the inner and outer cylinders lead to greatly improved flow distribution patterns and very low fluid shear stress levels over a large percentage of the fluid volume. Differences in flow patterns for the different operating conditions are explored. Large differences in the hydrodynamic environments for operating conditions typical of true microgravity and ground-based "microgravity simulations" are demonstrated.

Bioreactors↗

Dynamic Measurement of Temperature, Velocity, and Density in Hot Jets Using Rayleigh Scattering

A molecular Rayleigh scattering technique is utilized to measure gas temperature, velocity, and density in unseeded gas flows at sampling rates up to 10 kHz, providing fluctuation information up to 5 kHz based on the Nyquist theorem. A high-power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to a Fabry-Perot interferometer for spectral analysis. Photomultiplier tubes operated in the photon counting mode allow high-frequency sampling of the total signal level and the circular interference pattern to provide dynamic density, temperature, and velocity measurements. Mean and root mean square velocity, temperature, and density, as well as power spectral density calculations, are presented for measurements in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at NASA John H. Glenn Research Center at Lewis Field. The Rayleigh measurements are compared with particle image velocimetry data and computational fluid dynamics predictions. This technique is aimed at aeronautics research related to identifying noise sources in free jets, as well as applications in supersonic and hypersonic flows where measurement of flow properties, including mass flux, is required in the presence of shocks and ionization occurrence.

Mielke, Amy F.↗

Fluid shifts in weightlessness

Studies of leg volumes in space by multiple girth measurements showed reductions of 1.9 l (12.8 percent of leg volume), with 1.1 l from the nondominant leg, on Skylab 4. On landing, 65 percent of postflight leg volume increase was complete at 1.5 h. Measurement of the dominant leg during the equivalent period on Shuttle showed a mean loss of 0.9 l which was 90-percent complete at 150 min. Postflight increases were 87-percent complete at 1.5 h postlanding. Mass measurements during and after Skylab 4 showed a loss of 2.5 kg over the first 4 d on orbit, with a gain of 2.7 kg over the first 4 d of recovery. These changes are assumed to be tissue fluids secondary to changes in hydrostatic pressures and are much greater than those seen in bed rest. Rate and magnitude of inflight and postflight changes have significant operational impact.

Thornton, William E.↗

Impact of plasma response on plasma displacements in DIII-D during application of external 3D perturbations

The effects of applied non-axisymmetric resonant magnetic perturbations (RMPs) are predicted without and with self-consistent plasma response by modeling of the magnetic field structure and two-fluid MHD simulations, respectively. A synthetic diagnostic is used to simulate soft X-ray (SXR) emission within the steep gradient region of the pedestal, 0.98 > ψ > 0.94. The entire pedestal and edge region is characterized by large changes in plasma rotation and current density. Those parameters are expected to strongly affect the plasma response to RMPs. The M3D-C1 code takes into account this response self-consistently. The plasma response is investigated in detail and used in the forward modeling of the simulated local SXR emission, within the framework of the synthetic diagnostic. The resulting synthetic emission is compared to measured SXR data. The latter clearly shows helical m = 11 ± 1 displacements around the 11/3 rational surface of sizes up to 5 cm, which change with the poloidal angle. The synthetic emission with plasma response is used to explain the nature of the measured displacements. Different approaches are tested. One approach is based on the magnetic field structure to simulate local emission, which shows additional structures at the separatrix, that are caused by the lobes. Especially without plasma response, almost only separatrix structures are generated while no significant displacements are found further inside. Another approach to model local emission uses the fluid quantities electron density and temperature, as calculated by M3D-C1. Compared to the previous approach, based on the magnetic field structure, the emission simulated by the fluid approach with plasma response shows better agreement with the measured SXR data. To be specific, it has comparable displacements in the steep gradient region and no lobe structures at all. The helical displacements around the 11/3 surface are identified to be directly related to the kink response, caused by non-resonant amplification of various poloidal RMP modes due to plasma response. Regarding the latter, the role of different plasma parameters is investigated, but it appears that the electron rotation plays a key role in the formation of screening and resonant amplification, while the kinking appears to be sensitive to the edge current density. As a result, it is also hypothesised that the strength of the kink response is also correlated to edge-localized-mode (ELM) stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Damping Physics and CFD Tool Validation for Simulation of Baffled Tanks at Variable Slosh Amplitude

Determination of slosh damping is a very challenging task as there is no analytical solution. The damping physics involves the vorticity dissipation which requires the full solution of the nonlinear Navier-Stokes equations. As a result, previous investigations were mainly carried out by extensive experiments. A systematical study is needed to understand the damping physics of baffled tanks, to identify the difference between the empirical Miles equation and experimental measurements, and to develop new semi-empirical relations to better represent the real damping physics. The approach of this study is to use Computational Fluid Dynamics (CFD) technology to shed light on the damping mechanisms of a baffled tank. First, a 1-D Navier-Stokes equation representing different length scales and time scales in the baffle damping physics is developed and analyzed. Loci-STREAM-VOF, a well validated CFD solver developed at NASA MSFC, is applied to study the vorticity field around a baffle and around the fluid-gas interface to highlight the dissipation mechanisms at different slosh amplitudes. Previous measurement data is then used to validate the CFD damping results. The study found several critical parameters controlling fluid damping from a baffle: local slosh amplitude to baffle thickness (A/t), surface liquid depth to tank radius (d/R), local slosh amplitude to baffle width (A/W); and non-dimensional slosh frequency. The simulation highlights three significant damping regimes where different mechanisms dominate. The study proves that the previously found discrepancies between Miles equation and experimental measurement are not due to the measurement scatter, but rather due to different damping mechanisms at various slosh amplitudes. The limitations on the use of Miles equation are discussed based on the flow regime.

Yang, H. Q.↗

Validity of Miles Equation in Predicting Propellant Slosh Damping in Baffled Tanks at Variable Slosh Amplitude

Determination of slosh damping is a very challenging task as there is no analytical solution. The damping physics involves the vorticity dissipation which requires the full solution of the nonlinear Navier-Stokes equations. As a result, previous investigations were mainly carried out by extensive experiments. A systematical study is needed to understand the damping physics of baffled tanks, to identify the difference between the empirical Miles equation and experimental measurements, and to develop new semi-empirical relations to better represent the real damping physics. The approach of this study is to use Computational Fluid Dynamics (CFD) technology to shed light on the damping mechanisms of a baffled tank. First, a 1-D Navier-Stokes equation representing different length scales and time scales in the baffle damping physics is developed and analyzed. Loci-STREAM-VOF, a well validated CFD solver developed at NASA MSFC, is applied to study the vorticity field around a baffle and around the fluid-gas interface to highlight the dissipation mechanisms at different slosh amplitudes. Previous measurement data is then used to validate the CFD damping results. The study found several critical parameters controlling fluid damping from a baffle: local slosh amplitude to baffle thickness (A/t), surface liquid depth to tank radius (d/R), local slosh amplitude to baffle width (A/W); and non-dimensional slosh frequency. The simulation highlights three significant damping regimes where different mechanisms dominate. The study proves that the previously found discrepancies between Miles equation and experimental measurement are not due to the measurement scatter, but rather due to different damping mechanisms at various slosh amplitudes. The limitations on the use of Miles equation are discussed based on the flow regime.

Yang, H. Q.↗

Validity of Miles Equation in Predicting Propellant Slosh Damping in Baffled Tanks at Variable Slosh Amplitude

Determination of slosh damping is a very challenging task as there is no analytical solution. The damping physics involves the vorticity dissipation which requires the full solution of the nonlinear Navier-Stokes equations. As a result, previous investigations were mainly carried out by extensive experiments. A systematical study is needed to understand the damping physics of baffled tanks, to identify the difference between the empirical Miles equation and experimental measurements, and to develop new semi-empirical relations to better represent the real damping physics. The approach of this study is to use Computational Fluid Dynamics (CFD) technology to shed light on the damping mechanisms of a baffled tank. First, a 1-D Navier-Stokes equation representing different length scales and time scales in the baffle damping physics is developed and analyzed. Loci-STREAM-VOF, a well validated CFD solver developed at NASA MSFC, is applied to study the vorticity field around a baffle and around the fluid-gas interface to highlight the dissipation mechanisms at different slosh amplitudes. Previous measurement data is then used to validate the CFD damping results. The study found several critical parameters controlling fluid damping from a baffle: local slosh amplitude to baffle thickness (A/t), surface liquid depth to tank radius (d/R), local slosh amplitude to baffle width (A/W); and non-dimensional slosh frequency. The simulation highlights three significant damping regimes where different mechanisms dominate. The study proves that the previously found discrepancies between Miles equation and experimental measurement are not due to the measurement scatter, but rather due to different damping mechanisms at various slosh amplitudes. The limitations on the use of Miles equation are discussed based on the flow regime.

Yang, H. Q.↗

Positron scattering from neon and argon

High-resolution measurements of positron interactions with Ne and Ar are presented, as well as theoretical treatments. The data extend over a range of 0.3 to 60 eV and comprise measurements of the grand total, positonium formation, and grand total minus positronium formation cross sections. Theoretical treatments of scattering from Ne and Ar are performed under the relativistic optical potential approach, as well as calculations using the convergent close-coupling method. Comparisons of the present measurements and theories are made with previous theoretical and experimental work.

74 ATOMIC AND MOLECULAR PHYSICS↗

Flow Distribution Measurement Feasibility in Supercritical CO 2

Supercritical CO 2 (sCO 2 ) is a fluid of interest for advanced power cycles that can reach thermal to electric energy conversion efficiencies of 50% or higher. Of particular interest for fossil-fired natural gas is the Allam cycle that captures nearly all CO 2 emissions and exports it as a fluid stream where it may be of value. The combustion process conditions are unlike any before realized with 90-95% CO 2 concentration, temperatures around 1000°C, and pressures near 300 bar. This work outlines the experimental feasibility of flow measurements to acquire the first known data in pure sCO 2 at similar but reduced temperature and pressure conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗