Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Fiber optic spectroscopic digital imaging sensor and method for flame properties monitoring

A system for real-time monitoring of flame properties in combustors and gasifiers which includes an imaging fiber optic bundle having a light receiving end and a light output end and a spectroscopic imaging system operably connected with the light output end of the imaging fiber optic bundle. Focusing of the light received by the light receiving end of the imaging fiber optic bundle by a wall disposed between the light receiving end of the fiber optic bundle and a light source, which wall forms a pinhole opening aligned with the light receiving end.

47 OTHER INSTRUMENTATION↗

Structural and Morphological Evolution of Lead Dendrites during Electrochemical Migration

The electrochemical deposition and dissolution of lead on gold electrodes immersed in an aqueous solution of lead nitrate were studied in situ using a biasing liquid cell by transmission electron microscopy (TEM). We investigate in real time the growth mechanisms of lead dendrites as deposited on the electrodes under an applied potential. TEM images reveal that lead dendrites are developed by the fast protrusion of lead branches in the electrolyte and tip splitting. And, the fast growing tip of the dendritic branch is composed of polycrystalline nanograins and it develops into a single crystalline branch eventually. This study demonstrated unique electrochemical growth of single crystal dendrites through nucleation, aggregation, alignment and attachment of randomly oriented small grains. Additionally, we found the lead concentration in the electrolyte drastically influences the morphology of dendritic formation.

25 ENERGY STORAGE↗

Aurora on Ganymede

Jupiter's largest satellite Ganymede is unique because it possesses an internal magnetic field strong enough to create a small magnetosphere around the satellite. The interaction between Ganymede's magentosphere and the Jovian magnetic field and magnetospheric plasma generates classic polar auroral emissions from Ganymede which have been captured in a series of stunning ultraviolet images using the Hubble Space Telescope on six different dates from 1998 to 2012. Analysis of these images (McGrath et al. 2013) has provided a nearly global mapping of the location of Ganymede's auroral ovals, which appear to be remarkably stable in the 14 years spanning the observations. The location of the auroral ovals is compared with several model predictions of the boundary between open and closed magnetic field lines (Koop and Ip 2002; Khurana et al. 2007; Jia et al. 2009), a region where strong field aligned potentials are a likely candidate to accelerate electrons that produce the auroral emissions. The location of the auroral emission is also compared with the polar cap boundary on Ganymede, thought to be produced by charged particle bombardment of the polar region, as delineated by color ratio images acquired by the Galileo mission (Khurana et al. 2007).

McGrath, Melissa A.↗

AAPM Task Group 128: Quality assurance tests for prostate brachytherapy ultrasound systems

While ultrasound guided prostate brachytherapy has gained wide acceptance as a primary treatment tool for prostate cancer, quality assurance of the ultrasound guidance system has received very little attention. Task Group 128 of the American Association of Physicists in Medicine was created to address quality assurance requirements specific to transrectal ultrasound used for guidance of prostate brachytherapy. Accurate imaging guidance and dosimetry calculation depend upon the quality and accuracy of the ultrasound image. Therefore, a robust quality assurance program for the ultrasound system is essential. A brief review of prostate brachytherapy and ultrasound physics is provided, followed by a recommendation for elements to be included in a comprehensive test phantom. Specific test recommendations are presented, covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, needle template/electronic grid alignment, and geometric consistency with the treatment planning computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavefront Compensation Segmented Mirror Sensing and Control

The primary mirror of very large submillimeter-wave telescopes will necessarily be segmented into many separate mirror panels. These panels must be continuously co-phased to keep the telescope wavefront error less than a small fraction of a wavelength, to ten microns RMS (root mean square) or less. This performance must be maintained continuously across the full aperture of the telescope, in all pointing conditions, and in a variable thermal environment. A wavefront compensation segmented mirror sensing and control system, consisting of optical edge sensors, Wavefront Compensation Estimator/Controller Soft ware, and segment position actuators is proposed. Optical edge sensors are placed two per each segment-to-segment edge to continuously measure changes in segment state. Segment position actuators (three per segment) are used to move the panels. A computer control system uses the edge sensor measurements to estimate the state of all of the segments and to predict the wavefront error; segment actuator commands are computed that minimize the wavefront error. Translational or rotational motions of one segment relative to the other cause lateral displacement of the light beam, which is measured by the imaging sensor. For high accuracy, the collimator uses a shaped mask, such as one or more slits, so that the light beam forms a pattern on the sensor that permits sensing accuracy of better than 0.1 micron in two axes: in the z or local surface normal direction, and in the y direction parallel to the mirror surface and perpendicular to the beam direction. Using a co-aligned pair of sensors, with the location of the detector and collimated light source interchanged, four degrees of freedom can be sensed: transverse x and y displacements, as well as two bending angles (pitch and yaw). In this approach, each optical edge sensor head has a collimator and an imager, placing one sensor head on each side of a segment gap, with two parallel light beams crossing the gap. Two sets of optical edge sensors are used per segment-to-segment edge, separated by a finite distance along the segment edge, for four optical heads, each with an imager and a collimator. By orienting the beam direction of one edge sensor pair to be +45 away from the segment edge direction, and the other sensor pair to be oriented -45 away from the segment edge direction, all six degrees of freedom of relative motion between the segments can be measured with some redundancy. The software resides in a computer that receives each of the optical edge sensor signals, as well as telescope pointing commands. It feeds back the edge sensor signals to keep the primary mirror figure within specification. It uses a feed-forward control to compensate for global effects such as decollimation of the primary and secondary mirrors due to gravity sag as the telescope pointing changes to track science objects. Three segment position actuators will be provided per segment to enable controlled motions in the piston, tip, and tilt degrees of freedom. These actuators are driven by the software, providing the optical changes needed to keep the telescope phased.

Redding, David C.↗

DCE-MRI defined subvolumes of a brain metastatic lesion by principle component analysis and fuzzy-c-means clustering for response assessment of radiation therapy

Purpose: To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. Methods: Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation therapy (WBRT) and at the end of the 2-week therapy. The volumetric DCE images covering the whole brain were acquired on a 3T scanner with approximately 5 s temporal resolution and a total scan time of about 3 min. DCE curves from all voxels of the 45 brain metastases were normalized and then temporally aligned. A DCE matrix that is constructed from the aligned DCE curves of all voxels of the 45 lesions obtained prior to WBRT is processed by principal component analysis to generate the principal components (PCs). Then, the projection coefficient maps prior to and at the end of WBRT are created for each lesion. Next, a pattern recognition technique, based upon fuzzy-c-means clustering, is used to delineate the tumor subvolumes relating to the value of the significant projection coefficients. The relationship between changes in different tumor subvolumes and treatment response was evaluated to differentiate responsive from stable and progressive tumors. Performance of the PC-defined tumor subvolume was also evaluated by receiver operating characteristic (ROC) analysis in prediction of nonresponsive lesions and compared with physiological-defined tumor subvolumes. Results: The projection coefficient maps of the first three PCs contain almost all response-related information in DCE curves of brain metastases. The first projection coefficient, related to the area under DCE curves, is the major component to determine response while the third one has a complimentary role. In ROC analysis, the area under curve of 0.88 ± 0.05 and 0.86 ± 0.06 were achieved for the PC-defined and physiological-defined tumor subvolume in response assessment. Conclusions: The PC-defined subvolume of a brain metastasis could predict tumor response to therapy similar to the physiological-defined one, while the former is determined more rapidly for clinical decision-making support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scheduling Observations of Celestial Objects for Earth Observing Sensor Calibration

Radiometric calibration of Earth-observing satellite sensors is critical for tracking on-orbit gain changes through- out the satellite's mission. The Moon, being a stable, well-characterized radiometric target, has been used effectively for tracking the relative gain changes of the reflective solar bands for the Moderate Resolution Imaging Spectroradiometer (MODIS) on board EOS AM-1 (Terra) and PM-1 (Aqua). The Moon is viewed through the MODIS space-view port, and the relative phase of the Moon is restricted to within 0.5 degrees of a chosen target phase to increase the accuracy of the calibration. These geometric restrictions require spacecraft maneuvers in order to bring space-view port into proper alignment with the position of the Moon when the phase requirement is met. In this paper, we describe a versatile tool for scheduling such maneuvers based on the required geometry and lunar phase restrictions for a general spacecraft bound instrument. The results of the scheduling tool have been verified using lunar images from Aqua and Terra MODIS after a scheduled roll maneuver was performed. This tool has also been tested for the Visible Infrared Imaging Radiometer Suite (VIIRS) and the Advanced Technology Microwave Sounder on-board the Suomi-NPP spacecraft. As an extension of this work, we have also developed a tool for scheduling views of bright stars. These stars provide another well-characterized radiometric source that can be used for sensor calibration. This tool has been implemented to determine the times in which a chosen star can be viewed by the high gain stages of the day/night band for the VIIRS instrument.

Wilson, Truman↗

Wave-Front Error Measurements and Alignment of CLASP2 Telescope with a Dual-Band Pass Cold Mirror Coated Primary Mirror

"Chromospheric LAyer Spectro-Polarimeter (CLASP2)" is the next sounding rocket experiment of the "Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)" that succeeded in observing for the first time the linear polarization spectra in the hydrogen Lyman- line (121.6 nm) and is scheduled to be launched in 2019. In CLASP2, we will carry out full Stokes-vector spectropolarimetric observations in the Mg II h & k lines near 280 nm with the spectro-polarimeter (SP), while imaging observations in the Lyman- line will be conducted with the slitjaw optics (SJ). For the wavelength selection of CLASP2, the primary mirror of the telescope uses a new dual-band pass cold mirror coating targeting both at 121.6 nm and 280 nm. Therefore, we have to perform again the alignment of the telescope after the installation of the recoated primary mirror. Before unmounting the primary mirror from the telescope structure, we measured the wave-front error (WFE) of the telescope. The measured WFE map was consistent with what we had before the CLASP flight, clearly indicating that the telescope alignment has been maintained even after the flight. After the re-coated primary mirror was installed the WFE was measured, and coma aberration was found to be larger. Finally, the secondary mirror shim adjustments were carried out based on the WFE measurements. In CLASP2 telescope, we improved a fitting method of WFE map (applying 8th terms circular Zernike polynomial tting instead of 37th terms circular Zernike fitting) and the improved method enables to achieve better performance than CLASP telescope. Indeed, WFE map obtained after the final shim adjustment indicated that the required specification (< 5:5 m RMS spot radius) that is more stringent than CLASP telescope was met.

chromosphere; polarimetry; sounding rocket↗

Global Auroral Energy Deposition Derived from Polar UVI Images

Quantitative measurement of the transfer of energy and momentum to the ionosphere from the solar wind is one of the main objectives of the ISTP program. Global measurement of auroral energy deposition derived from observations of the longer wavelength LBH band emissions made by the Ultraviolet Imager on the Polar spacecraft is one of the key elements in this satellite and ground-based instrument campaign. These "measurements" are inferred by combining information from consecutive images using different filters and have a time resolution on the average of three minutes and are made continuously over a 5 to 8 hour period during each 18 hour orbit of the Polar spacecraft. The energy deposition in the ionosphere from auroral electron precipitation augments are due to Joule heating associated with field aligned currents. Assuming conjugacy of energy deposition between the two hemispheres the total energy input to the ionosphere through electron precipitation can be determined at high time resolution. Previously, precipitating particle measurements along the tracks of low altitude satellites provided only local measurements and the global energy precipitation could be inferred through models but not directly measured. We use the UVI images for the entire month of January 1997 to estimate the global energy deposition at high time resolution. We also sort the energy deposition into sectors to find possible trends, for example, on the dayside and nightside, or the dawn and dusk sides.

Fillingim, M. O.↗

Spatially resolved band alignments at Au-hexadecanethiol monolayer-GaAs(001) interfaces by ballistic electron emission microscopy

We study structural and electronic inhomogeneities in Metal—Organic Molecular monoLayer (OML)—semiconductor interfaces at the sub-nanometer scale by means of in situ Ballistic Electron Emission Microscopy (BEEM). BEEM imaging of Au/1-hexadecanethiols/GaAs(001) heterostructures reveals the evolution of pinholes density as a function of the thickness of the metallic top-contact. Using BEEM in spectroscopic mode in non-short-circuited areas, local electronic fingerprints (barrier height values and corresponding spectral weights) reveal a low-energy tunneling regime through the insulating organic monolayer. At higher energies, BEEM evidences new conduction channels, associated with hot-electron injection in the empty molecular orbitals of the OML. Corresponding band diagrams at buried interfaces can be thus locally described. The energy position of GaAs conduction band minimum in the heterostructure is observed to evolve as a function of the thickness of the deposited metal, and coherently with size-dependent electrostatic effects under the molecular patches. Such BEEM analysis provides a quantitative diagnosis on metallic top-contact formation on organic molecular monolayer and appears as a relevant characterization for its optimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ZnO-Au x Cu 1-x Alloy and ZnO-Au x Al 1-x Alloy Vertically Aligned Nanocomposites for Low-Loss Plasmonic Metamaterials

Hyperbolic metamaterials are a class of materials exhibiting anisotropic dielectric function owing to the morphology of the nanostructures. In these structures, one direction behaves as a metal, and the orthogonal direction behaves as a dielectric material. Applications include subdiffraction imaging and hyperlenses. However, key limiting factors include energy losses of noble metals and challenging fabrication methods. In this work, self-assembled plasmonic metamaterials consisting of anisotropic nanoalloy pillars embedded into the ZnO matrix are developed using a seed-layer approach. Alloys of Au x Al 1-x or Au x Cu 1-x are explored due to their lower losses and higher stability. Optical and microstructural properties were explored. The ZnO-Au x Cu 1-x system demonstrated excellent epitaxial quality and optical properties compared with the ZnO-Au x Al 1-x system. Both nanocomposite systems demonstrate plasmonic resonance, hyperbolic dispersion, low losses, and epsilon-near-zero permittivity, making them promising candidates towards direct photonic integration.

36 MATERIALS SCIENCE↗

The Future: Nasa’s Surface Biology and Geology Mission and the Dark (Aquatic) Side

With the release of NASA’s Earth System Observatory (ESO) measurement targets that includes studying the Earth’s Surface Biology and Geology (SBG), a global visible to shortwave infrared imaging spectrometer and a multispectral thermal infrared imager have been planned to launch in the late 2020s. This mission will enable unprecedented interdisciplinary science and applications relevant to studying the biology and geology of the Earth's surface. Measurement targets are directly aligned for studying coastal and inland waters ecosystems and water quality, including coralreef ecosystems, snow and ice, mineralogy, volcanology, biology, ecology, biodiversity, and components of radiative forcing from the surface such as greenhouse gas emissions. The observations not only have scientific value in studying feedbacks and interactions of surface processes (e.g., harmful algal blooms, domoic acid, oil spills, and other hazardous events), but also societal benefit – with the capacity to support real-world decision-making such as response to theseevents and inland water conservation, protection of drinking water quality for public and environmental health, and habitat conservation. The work presented here outlines the conducted mission and architecture study and the initiation of science performance trades (signal sensitivity; spectral, spatial, and temporal resolution; and atmospheric effects) informing the design of the SBG segment of the ESO providing the most value to myriad science and applications as possible. Science and applications synergies and algorithms with the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) and the Geostationary Littoral Imaging and Monitoring Radiometer (GLIMR) is opportunistic for advancing aquatics research and applications.

THE FUTURE↗

AN STIS ATLAS OF Ca II TRIPLET ABSORPTION LINE KINEMATICS IN GALACTIC NUCLEI

The relations observed between supermassive black holes and their host galaxies suggest a fundamental link in the processes that cause these two objects to evolve. A more comprehensive understanding of these relations could be gained by increasing the number of supermassive black hole mass (M{sub .}) measurements. This can be achieved, in part, by continuing to model the stellar dynamics at the centers of galactic bulges using data of the highest possible spatial resolution. Consequently, we present here an atlas of galaxies in the Space Telescope Imaging Spectrograph (STIS) data archive that may have spectra suitable for new M{sub .} estimates. Archived STIS G750M data for all non-barred galactic bulges are co-aligned and combined, where appropriate, and the radial signal-to-noise ratios calculated. The line-of-sight velocity distributions from the Ca II triplet are then determined using a maximum penalized likelihood method. We find 19 out of 42 galaxies may provide useful new M{sub .} estimates since they are found to have data that is comparable in quality with data that has been used in the past to estimate M{sub .}. However, we find no relation between the signal-to-noise ratio in the previously analyzed spectra and the uncertainties of the black hole masses derived from the spectra. We also find that there is a very limited number of appropriately observed stellar templates in the archive from which to estimate the effects of template mismatching.

79 ASTRONOMY AND ASTROPHYSICS↗

Evolution of structure growth during dark energy domination: Insights from the cross-correlation of DESI galaxies with CMB lensing and galaxy magnification

We use a hybrid effective field theory (HEFT) model to constrain the evolution of low-redshift (z≲0.4) matter fluctuations by cross-correlating DESI Bright Galaxy Survey (BGS) legacy imaging with the latest cosmic microwave background (CMB) lensing maps from Planck and Atacama cosmology telescope. Our tomographic BGS analysis finds that the evolution and amplitude of matter fluctuations align with CMB-conditioned Λ cold dark matter predictions. When including DESI baryon acoustic oscillation (BAO) measurements we obtain σ8=0.876-0.067+0.051 from BGS alone. Jointly analyzing BGS and luminous red galaxy (LRG) cross-correlations with the same CMB lensing maps yields σ8=0.791±0.021. As a complementary approach we isolate the galaxy magnification signal from the cross-correlation of nonoverlapping BGS and LRG photometric redshift bins, ruling out the null-magnification hypothesis at 11σ. For the first time, we constrain quasilinear structure growth from the (finite-difference calibrated) galaxy magnification signal and find σ8=0.720±0.047(stat)±0.050(sys) assuming a linear bias model and including BAO data.

Sailer, Noah↗

Magnetic domain tuning and the emergence of bubble domains in the bilayer manganite La 2 - 2 x Sr 1 + 2 x Mn 2 O 7 ( x = 0.32 )

Here, we report a magnetic force microscopy study of the magnetic domain evolution in the layered manganite La 2–2x Sr 1+2x Mn 2 O 7 (with x = 0.32). This strongly correlated electron compound is known to exhibit a wide range of magnetic phases, including a recently uncovered biskyrmion phase. We observe a continuous transition from dendritic to stripelike domains, followed by the formation of magnetic bubbles due to a field- and temperature-dependent competition between in-plane and out-of-plane spin alignments. The magnetic bubble phase appears at comparable field and temperature ranges as the biskyrmion phase, suggesting a close relation between both phases. Based on our real-space images we construct a temperature-field phase diagram for this composition.

36 MATERIALS SCIENCE↗

Aspheric doublets and precision adjustable fold mirrors for 20 K operation in CLAES

A cooled, infrared spectrometer is required to operate in earth orbit. The spectrometer performance requirements are discussed to show how package volume constraints and the stressing environment of cryogenic operation affect the detailed design of spectrometer components such as relay imaging optics and fold mirrors. Design steps are described that were taken to insure that the spectrometer would perform well in orbit, with components that are easily manufactured, readily aligned and stable in operation. This design procedure has produced two components of special interest, fast doublets suitable for use at 20 K over the wavelength band from 3.5 to 12 microns, and fold mirrors that can be adjusted to arc second tolerances.

Zinky, William R.↗

Optical Fabrication and Measurement: AR&C and NGST

The need exists at MSFC for research and development within three major areas: (1) Automated Rendezvous and Capture (AR&C) including Video Guidance System (VGS); (2) Next Generation Space Telescope, (NGST); and (3) replicated optics. AR&C/VGS is a laser retroreflection guidance and tracking device which is used from the shuttle to provide video information regarding deployment and guidance of released satellites. NGST is the next large telescope for space to complement Hubble Space Telescope. This will be larger than HST and may be produced in segments to be assembled and aligned in space utilizing advanced mechanisms and materials. The replicated optics will involve a variety of advanced procedures and materials to produce x-ray collimating as well as imaging telescopes and optical components.

Martin, Greg↗

SU-E-J-222: Feasibility Study of MRI-Only Proton Therapy Planning

Purpose: To assess the dosimetric equivalence of MRI based proton planning vs. single energy x-ray CT. Methods: 8 glioblastoma patients were imaged with CT and MRI after surgical resection. T1-weighted 3DMPRAGE was used to delineate the GTV, which was subsequently rigidly registered to the CT volume. A pseudoCT was generated from the aligned MRI by combining segmentation and atlas-based approaches. The spatial resolution both for pseudo- and real CT was 0.6×0.6×2.5mm. Three orthogonal proton beams were simulated on the pseudoCT. Two co-planar beams were set on the axial plane. The third one was planned parallel to the cranio-caudal (CC) direction. Each beam was set to cover the GTV at 98% of the nominal dose (18Gy). The proton plan was copied and transferred to the real CT, including aperture/compensator geometry. Dose comparison between pseudoCT and CT plan was performed beam-by-beam by quantifying the range shift of dose profile on each slice of the GTV. The GTV’s V{sub 98} was computed for the CT. Results: For beams in axial plane the median absolute value of the range shift was 0.3mm, with 0.9mm and 1.4mm as 95th percentile and maximum, respectively. Worst scenarios were found for the CC beam, where we measured 1.1mm (median), 2.7mm (95thpercentile) and 5mm (maximum). Regardless the direction, beams passing through the surgical site, where metal (Titanium MRI-compatible) staples were present, were mostly affected by range shift. GTV’s V{sub 98} for CT was not lower than 99.3%. Conclusion: The study showed the clinical feasibility of an MRI-alone proton plan. Advantages include the possibility to rely on better soft tissue contrast for target and organs at risk delineation without the need of further CT scan and image registration. Additional investigation is required in presence of metal implants along the beam path and to account for partial volume effects due to slice thickness.

60 APPLIED LIFE SCIENCES↗