Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Electrotransport purification of thorium under low pressure conditions

It was demonstrated that the ultrapurification of refractory metals by electrotransport refining could best be accomplished in the noncontaminating environment of an orbiting low density materials laboratory such as the Molecular Shield Device. Refining experiments were performed at 2 x 10 to the -12th Torr which resulted in the preparation of small quantities of the World's purest thorium metal. The microgravity occurring in orbit was simulated electromagnetically and shown to be advantageous in eliminating grain-sliding caused by the plastic deformation of the sample at high temperature. The electrotransport sample assembly was tested in several environments including simulated solar irradiation, coldness and darkness and under various pressure conditions. Ultrapure single crystals of alpha thorium were also prepared and characterized. Laboratory electronics for the experiment were developed and a totally automatic control system was used to heat the specimens.

Schmidt, F. A.↗

Testing and characterization of an IR CBIRD FPA

High performance IR cameras are in great demand for a variety of applications, including defense (e.g. night vision, missile detection) and space (e.g. imaging at IR wavelengths). IR focal plane arrays (FPAs) are an essential component of IR cameras. An FPA is a collection of detectors at the focal plane of an imaging device, where each detector can be thought of a pixel in the image it is detecting. The FPA in this study is based on Complimentary Barrier Infrared Detectors (CBIRDs). The CBIRD FPA was tested by imaging flat black body targets at three different temperatures, 20ºC, 25ºC, and 30ºC, with images captured using SEIR software. The important figures of merit for an IR FPA, Noise Equivalent Difference Temperature (NEDT), Noise Equivalent Irradiance (NEI), detectivity (D*), responsivity, and quantum Efficiency (QE), were extracted from the image data for each individual detector using a MATLAB program, as was the array Modulation Transfer Function MTF. The test results show a mean NEDT of 16.98mK and an MTF of about 0.34 at the Nyquist frequency. Overall, the array performs well in the MWIR range and takes quality IR images.

Das, Tanya↗

Temporal stability of Y Ba Cu O nano Josephson junctions from ion irradiation

We investigate the temporal stability of YBa2Cu3O7 Josephson junctions created by ion irradiation through a nano-scale implant mask fabricated using electron beam lithography and reactive ion etching. A comparison of current-voltage characteristics measured for junctions after fabrication and eight years of storage at room temperature show a slight decrease in critical current and increase in normal state resistance consistent with broadening of the weaklink from diffusion of defects. Shapiro step measurements performed 8 years after fabrication reveal that device uniformity is maintained and is strong evidence that these devices have excellent temporal stability for applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

R&D for new silicon pixel sensors for the High Luminosity phase of the CMS experiment at LHC

The High Luminosity upgrade of the CERN LHC collider (HL-LHC) demands a new high-radiation–tolerant solid-state pixel sensor capable of surviving fluencies up to a few 10$^{16} n_{eq}/\mathrm{cm}^2$ at ~ 3 cm from the interaction point. To this extent the INFN ATLAS-CMS joint research activity, in collaboration with Fondazione Bruno Kessler (FBK), is aiming at the development of thin n -in- p –type pixel sensors for the HL-LHC. The R&D covers both planar and single-sided 3D columnar pixel devices made with the Si-Si Direct Wafer Bonding technique, which allows for the production of sensors with 100 μm and 130 μm active thickness for planar sensors, and 130 μm for 3D sensors, the thinnest ones ever produced so far. The first prototypes of hybrid modules, bump-bonded to the present CMS readout chip, have been tested on beam. The first results on their performance before and after irradiation are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Characterization of Commercial GaN Devices

Radiative feedback from primordial protostars and final mass of the first star Commercially available devices fabricated from GaN are beginning to appear from a number of different suppliers. Based on previous materials and prototype device studies, it is expected that these commercial devices will be quite tolerant to the types of radiation encountered in space. This expectation needs to be verified and the study described herein was undertaken for that purpose. All of the parts discussed in this report are readily available commercially. The parts chosen for study are all targeted for RF applications. Three different studies were performed: 1) a preliminary DDD/TID test of a variety of part types was performed by irradiating with 50 MeV protons, 2) a detailed DDD/TID study of one particular part type was performed by irradiating with 50 MeV protons, and 3) a SEB/SEGR test was performed on a variety of part types by irradiating with heavy ions. No significant degradation was observed in the tests performed in this study.

HEMT↗

Latent Effects of Radiation on Li-ion Batteries in Robots

The rapid development of Li-ion batteries (LIBs) is due to their high energy-density storage capability, which makes them suitable for application in both vehicles (e.g., electrified car) and electronic devices (e.g., cell phone, laptop, etc.), which are currently ubiquitous. Another less common but important application of LIBs is the powering of equipment in extreme environments such as robots operating in a nuclear rescue mission, unmanned vehicles surveying environments exposed to radiation, or vehicles and probes for outer space exploration. In our previous study, coin cells with lithium metal serving as the reference and counter electrode were assembled with either an irradiated cathode or irradiated electrolyte. We have observed an increase in premature battery failure and degradation of capacity of the battery made from irradiated cathodes and battery made from the irradiated electrolyte. For the group with cathodes irradiated to a 9.8 Mrad cumulative dose, the resistance was 2-3 times higher than the control group. On the other hand, cells with irradiated electrolyte showed increased resistance even at very low dose levels. Most importantly, a significant color change to the irradiated electrolyte after a long-term storage in a glove box has been observed. However, the electrolyte did not show any noticeable change immediately after irradiation. We name this phenomenon latent effects, which is more significant than the damage received by batteries due to initial dose. Also, electrolyte irradiated to a medium dose (1.6 Mrad) showed a poorer performance (higher failure rate, higher resistance) than those cells which received high dose (5 Mrad). We attribute this to the latent effect because this group battery was unintentionally assembled 3 days after initial electrolyte irradiation. The existence of latent effects implies that in space missions or post-accident events, instruments equipped with LIBs may fail unpredictably at post-irradiation stages, even if they survive the initial dose or the performance tests conducted after the initial dose. These instruments may fail several days or even weeks after irradiation, depending on the initial cumulative dose and dosage rate. For comprehending the influence of latent effects on the entire battery instead of on the individual components, we performed an in-situ cycling of coin cells made in-house, where the batteries were cycled under irradiation and then cycled again to evaluate their overall capacity fade, cyclability, and cell resistance. Additionally we investigated the effects of battery fading due to radiation on the performance of a drone.

25 ENERGY STORAGE↗

Ionizing mechanisms in a cesium plasma irradiated with a ruby laser

A cesium filled diode--laser plasmadynamic converter was built to investigate the feasibility of converting laser energy to electrical energy at large power levels. Experiments were performed with a pulsed ruby laser to determine the quantity of electrons and cesium ions generated per pulse of laser beam and to determine the output voltage. A current density as high as 200 amp/sq cm from a spot of approximately 1 sq mm area and an open circuit voltage as high as 1.5 volts were recorded. A qualitative theory was developed to explain these results. In the operation of the device, the laser beam evaporates some of the cesium and ionizes the cesium gas. A dense cesium plasma is formed to absorb further the laser energy. Results suggest that the simultaneous absorption of two ruby laser photons by the cesium atoms plays an important role in the initial ionization of cesium. Inverse bremsstrahlung absorption appears to be the dominant mechanism in subsequent processes. Recombinations of electrons and cesium ions appear to compete favorably with the simultaneous absorption of two photons.

Shimada, K.↗

Ferromagnetic resonance study of Co/Pd/Co/Ni multilayers with perpendicular anisotropy irradiated with helium ions

We present a ferromagnetic resonance (FMR) study of the effect of helium ion irradiation on the magnetic anisotropy, the linewidth and the Gilbert damping of a Co/Ni multilayer coupled to Co/Pd bilayers. The perpendicular magnetic anisotropy decreases linearly with He ion fluence, leading to a transition to in-plane magnetization at a critical fluence of 5x10{sup 14} ions/cm{sup 2}. We find that the damping is nearly independent of fluence but the FMR linewidth at fixed frequency has a maximum near the critical fluence, indicating that the inhomogeneous broadening of the FMR line is a nonmonotonic function of the He ion fluence. Based on an analysis of the angular dependence of the FMR linewidth, the inhomogeneous broadening is associated with spatial variations in the magnitude of the perpendicular magnetic anisotropy. These results demonstrate that ion irradiation may be used to systematically modify the magnetic anisotropy and distribution of magnetic anisotropy parameters of Co/Pd/Co/Ni multilayers for applications and basic physics studies.

36 MATERIALS SCIENCE↗

Anomalous transport of Sb in laser irradiated Ge

Excimer laser annealing is shown to be very promising to promote Sb incorporation in Ge up to concentrations as high as 1 Multiplication-Sign 10{sup 21} at./cm{sup 3}. However, we demonstrate that when Ge is melted by laser irradiation, a high excess of vacancies is generated in the molten region. These vacancies induce Sb electrical deactivation at the melt depth through the formation of Sb{sub m}-V{sub n} complexes that act as a sink for further Sb atoms, even leading Sb to back-diffuse towards the surface, against the concentration gradient. These results are fundamental for the realization of new generation Ge-based micro and optoelectronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly conducting SrMoO{sub 3} thin films for microwave applications

We have measured the microwave resistance of highly conducting perovskite oxide SrMoO{sub 3} thin film coplanar waveguides. The epitaxial SrMoO{sub 3} thin films were grown by pulsed laser deposition and showed low mosaicity and smooth surfaces with a root mean square roughness below 0.3 nm. Layer-by-layer growth could be achieved for film thicknesses up to 400 nm as monitored by reflection high-energy electron diffraction and confirmed by X-ray diffraction. We obtained a constant microwave resistivity of 29 μΩ·cm between 0.1 and 20 GHz by refining the frequency dependence of the transmission coefficients. Our result shows that SrMoO{sub 3} is a viable candidate as a highly conducting electrode material for all-oxide microwave electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simplifying EPID dosimetry for IMRT treatment verification

Purpose: Electronic portal imaging devices (EPIDs) are increasingly used for IMRT dose verification, both pretreatment and in vivo. In this study, an earlier developed backprojection model has been modified to avoid the need for patient-specific transmission measurements and, consequently, leads to a faster procedure. Methods: Currently, the transmission, an essential ingredient of the backprojection model, is estimated from the ratio of EPID measurements with and without a phantom/patient in the beam. Thus, an additional irradiation to obtain ''open images'' under the same conditions as the actual phantom/patient irradiation is required. However, by calculating the transmission of the phantom/patient in the direction of the beam instead of using open images, this extra measurement can be avoided. This was achieved by using a model that includes the effect of beam hardening and off-axis dependence of the EPID response on photon beam spectral changes. The parameters in the model were empirically obtained by performing EPID measurements using polystyrene slab phantoms of different thickness in 6, 10, and 18 MV photon beams. A theoretical analysis to verify the sensitivity of the model with patient thickness changes was performed. The new model was finally applied for the analysis of EPID dose verification measurements of step-and-shoot IMRT treatments of head and neck, lung, breast, cervix, prostate, and rectum patients. All measurements were carried out using Elekta SL20i linear accelerators equipped with a hydrogenated amorphous silicon EPID, and the IMRT plans were made using PINNACLE software (Philips Medical Systems). Results: The results showed generally good agreement with the dose determined using the old model applying the measured transmission. The average differences between EPID-based in vivo dose at the isocenter determined using either the new model for transmission and its measured value were 2.6{+-}3.1%, 0.2{+-}3.1%, and 2.2{+-}3.9% for 47 patients treated with 6, 10, and 18 MV IMRT beams, respectively. For the same group of patients, the differences in mean {gamma} analysis (3% maximum dose, 3 mm) were 0.16{+-}0.26%, 0.21{+-}0.24%, and 0.02{+-}0.12%, respectively. For a subgroup of 11 patients, pretreatment verification was also performed, showing similar dose differences at the isocenter: -1.9{+-}0.9%, -1.4{+-}1.2%, and -0.4{+-}2.4%, with somewhat lower mean {gamma} difference values: 0.01{+-}0.09%, 0.01{+-}0.07%, and -0.09{+-}0.10%, respectively. Clinical implementation of the new model would save 450 h/yr spent in measurement of open images. Conclusions: It can be concluded that calculating instead of measuring the transmission leads to differences in the isocenter dose generally smaller than 2% (2.6% for 6 MV photon beams for in vivo dose) and yielded only slightly higher {gamma}-evaluation parameter values in planes through the isocenter. Hence, the new model is suitable for clinical implementation and measurement of open images can be omitted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Epidemiologic Study of One Million U.S. Radiation Workers and Veterans

The single most important question in radiation epidemiology is determining the level of health risks associated with radiation exposures that occur gradually over time. The study of one million early U.S. radiation workers and veterans has been designed to provide information on risk following chronic exposures by focusing on occupational groups with differing radiation exposure patterns, including intakes of radionuclides. The cost-efficient study builds on the investments made and foundations laid by investigators and government agencies over the past 30-40 years, which have established early worker cohorts that can now provide answers to questions on the lifetime human health risks associated with low-level radiation exposures. Within the overall goal of the epidemiologic study of one million U.S. radiation workers and veterans, this project had a total of nine specific aims which included studies of six populations for multiple endpoints including cancer overall mortality, leukemia and non-cancer mortality. The six populations included: Mound, Ohio, workers exposed to polonium, tritium and plutonium; nuclear power plant workers within the Landauer dosimetry and Nuclear Regulatory Commission data files; industrial radiographers; Mallinckrodt uranium workers; uranium workers who linked with the US Renal Data System; and nuclear weapons test participants. Over 400,000 workers and atomic veterans are included in these populations, with vital status being determined and analyses of all causes of death undertaken. A critical, integral component of the studies has been comprehensive evaluations of dosimetry involving, in many cases, complex dose reconstructions, and assessments of uncertainties. The work has also involved development of state-of-the art statistical approaches and modeling. All nine aims were accomplished successfully, resulting in publication of two NCRP documents, 13 literature papers, numerous Boice Reports in Health Physics News and many presentations of the work at scientific meetings. Furthermore, recommendations have been developed for an approach to integrate epidemiologic observations with radiation biology for risk assessment and biological models of radiation effect. The results of this project, as well as ongoing epidemiology studies of US radiation workers and veterans, are providing much-needed insights into complex issues regarding cancer and non-cancer health risks from low dose irradiation, how to apply a "dose and dose rate effectiveness factor" to scale the risks from the A-bomb survivor data to current occupational and environmental circumstances, and how to evaluate risk following intakes of radioactive substances. In addition to application to radiation workers, the results of the studies can provide guidance as society debates the role of nuclear energy and deals with nuclear waste, threats of terrorist attacks with nuclear/radiological devices, the remarkable increase in medical exposures to CT scans and nuclear imaging, and to NASA as radiation protection for astronauts on long-duration mission beyond low-Earth orbit is planned.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Tolerance Studies of Long Wavelength Infrared InAs/GaSb Detectors

In this work we investigated the effect of proton irradiation on the performance of long wavelength infrared (LWIR) InAs/GaSb photodiodes (λ(sub c) = 10.2µm) based on the complementary barrier infrared detector (CBIRD) design. We found that irradiation with 68MeV protons up to the total ionizing dose TID = 200 kRad results in only small (about 15%) decrease of the Quantum Efficiency and does not increase the operational bias of the photodiodes. However, the irradiation causes a significant increase of the dark current from j(sub d) = 5x10(exp -5) A/sq cm at V(sub b) = 0.1V and T = 80K to j(sub d) = 6x10(exp -3) A/sq cm at TID = 200 kRad. This change in the dark current mechanism can be attributed to the onset of surface leakage current, generated by the trap assisted tunneling processes in the proton displacement damage areas near the device sidewalls.

InAs/GaSb photodiodes↗

Terahertz generation and power limits in In{sub 0.53}Ga{sub 0.47}As photomixer coupled to transverse-electromagnetic-horn antenna driven at 1.55 {mu}m wavelengths

We report continuous wave generation at frequencies up to 2 THz using ion-irradiated In{sub 0.53}Ga{sub 0.47}As photomixers coupled to transverse-electromagnetic-horn antennae driven at {approx}1.55 {mu}m wavelength. Output powers up to 0.1 {mu}W at 700 GHz have been achieved. The dependence of the output power on incident optical power and the bias voltage is analyzed in the both regimes of Ohmic transport and recombination-limited transport. The fundamental limitations of the performance of the photomixer devices based on photoconductive phenomenon in recombination-limited transport are analyzed.

36 MATERIALS SCIENCE↗

New oxyfluoride glass with high fluorine content and laser patterning of nonlinear optical BaAlBO{sub 3}F{sub 2} single crystal line

A new oxyfluoride glass of 50BaF{sub 2}-25Al{sub 2}O{sub 3}-25B{sub 2}O{sub 3} (mol. %) with a large fraction of fluorine, i.e., F/(F + O) = 0.4, was prepared using a conventional melt-quenching method in order to synthesize new glass-ceramics containing nonlinear optical oxyfluoride crystals. The refractive index at 632.8 nm and ultra-violet cutoff wavelength of the glass were 1.564 and {approx}200 nm, respectively. Eu{sup 3+} ions in the glass showed a high quantum yield of 88% in the photoluminescence spectrum in the visible region. BaAlBO{sub 3}F{sub 2} crystals (size: 50-100 nm) showing second harmonic generations were formed through the crystallization of the glass. Lines consisting of BaAlBO{sub 3}F{sub 2} crystals were patterned successfully on the glass surface by laser irradiations (Yb:YVO{sub 4} laser with a wavelength of 1080 nm, laser power of 1.1 W, scanning speed of 8 {mu}m/s). High resolution transmission electron microscope observations combined with a focused ion beam technique indicate that BaAlBO{sub 3}F{sub 2} crystals are highly oriented just like a single crystal. The present study proposes that the new oxyfluoride glass and glass-ceramics prepared have a high potential for optical device applications.

36 MATERIALS SCIENCE↗

2D lag and signal nonlinearity correction in an amorphous silicon EPID and their impact on pretreatment dosimetric verification

Purpose: This investigation provides measurements of signal lag and nonlinearity separately for the Varian aS500 electronic portal imaging device (EPID), and an algorithm to correct for these effects in 2D; their potential impact on intensity modulated radiation therapy (IMRT) verification is also investigated. The authors quantify lag, as a function of both delivered monitor units (MU) and time, by using a range of MUs delivered at a clinically used rate of 400 MU/min. Explicit cumulative lag curves are thus determined for a range of MUs and times between the end of irradiation and the end of image acquisition. Signal nonlinearity is also investigated as a function of total MUs delivered. The family of cumulative lag curves and signal nonlinearity are then used to determine their effects on dynamic multileaf collimator (MLC) (IMRT) deliveries, and to correct for theses effects in 2D. Methods: Images acquired with an aS500 EPID and Varis Portal-Vision software were used to quantify detector lag and signal-nonlinearity. For the signal lag investigation, Portal-Vision's service monitor was used to acquire EPID images at a rate of 8 frames/s. The images were acquired during irradiation and 66 s thereafter, by inhibiting the M-holdoff-In signal of the Linac for a range of 4.5-198.5 MUs. Relative cumulative lag was calculated by integrating the EPID signal for a time after beam-off, and normalizing this to the integrated EPID signal accumulated during radiation. Signal nonlinearity was studied by acquiring 10 Multiplication-Sign 10 cm{sup 2} open-field EPID images in 'integrated image' mode for a range of 2-500 MUs, and normalized to the 100 MU case. All data were incorporated into in-house written software to create a 2D correction map for these effects, using the field's MLC file and a field-specific calculated 2D 'time-map,' which keeps track of the time elapsed from the last fluence delivered at each given point in the image to the end of the beam delivery. Results: Relative cumulative lag curves reveal that the lag alone can deviate the EPID's perceived dose by as large as 6% (1 MU delivery, 60 s postirradiation). For signal nonlinearity relative to 100 MU, EPID signals per MU of 0.84 and 1.01 were observed for 2 and 500 MUs, respectively. Correction maps were applied to a 1 cm sweeping-window 14 Multiplication-Sign 14 cm{sup 2} field and clinical head-and-neck IMRT field. A mean correction of 1.028 was implemented in the head-and-neck field, which significantly reduced lag-related asymmetries in the EPID images, and restored linearity to the EPID imager's dose response. Corrections made to the sweeping-field showed good agreement with the treatment planning system-predicted field, yielding an average percent difference of 0.05%{+-} 0.91%, compared to the -1.32%{+-} 1.02% before corrections, or 1.75%{+-} 1.04% when only a signal nonlinearity correction is made. Conclusions: Lag and signal-nonlinearity have been quantified for an aS500 EPID imager, and an effective 2D correction method has been developed which effectively removes nonlinearity and lag effects. Both of these effects were shown to negatively impact IMRT verifications. Especially fields that involve prolonged irradiation and small overall MUs should be corrected for in 2D.

60 APPLIED LIFE SCIENCES↗

Enhanced Photoluminescence and Prolonged Carrier Lifetime through Laser Radiation Hardening and Self-Healing in Aged MAPbBr3 Perovskites Encapsulated in NiO Nanotubes

Organic-inorganic perovskites hold great promise as optoelectronic semiconductors for pure color light emitting and photovoltaic devices. However, challenges persist regarding their photostability and chemical stability, which limit their extensive applications. This paper investigates the laser radiation hardening and self-healing-induced properties of aged MAPbBr3 perovskites encapsulated in NiO nanotubes (MAPbBr3@NiO) using photoluminescence (PL) and fluorescence lifetime imaging (FLIM). After deliberately subjecting the MAPbBr3@ NiO to atmospheric conditions for two years, the sample remains remarkably stable. It exhibits no changes in PL wavelength during UV laser irradiation and self-healing. Furthermore, exposure to UV light at 375 nm enhances the PL of the self-healed MAPbBr3@NiO. FLIM analysis sheds light on the mechanism behind photodegradation, self-healing, and PL enhancement. The results indicate the involvement of many carrier-trapping states with low lifetime events and an increase in peak lifetime after self-healing. The formation of trapping states at the perovskite/nanotube interface is discussed and tested. This study provides new insights into the dynamics of photo-carriers during photodegradation and self-healing in organic-inorganic perovskites.

36 MATERIALS SCIENCE↗