Evolution of large-scale plasma structures in comets: Kinematics and physics

Cometary and solar wind data from December 1985 through April 1986 are presented for the purpose of determining the solar wind conditions associated with comet plasma tail disconnection events (DE's). The cometary data are from The International Halley Watch Atlas of Large-Scale Phenomena (Brandt, Niedner, and Rahe, 1992). In addition, we present the kinematic analysis of 4 DE's, those of Dec. 13.5 and 31.2, 1985, and Feb. 21.7 and 28.7, 1986. The circumstances of these DE's clearly illustrate the need to analyze DE's in groups. In situ solar wind measurements from IMP-8, ICE, and PVO were used to construct the variation of solar wind speed, density, and dynamic pressure during this interval. Data from these same spacecraft plus Vega-1 were used to determine the time of 48 current sheet crossings. These data were fitted to heliospheric current sheet curves extrapolated from the corona into the heliosphere in order to determine the best-fit source surface radius for each Carrington rotation. Comparison of the solar wind conditions and 16 DE's in Halley's comet (the four DE's discussed in this paper and 12 DE's in the literature) leaves little doubt that DE's are associated primarily with crossings of the heliospheric current sheet and apparently not with any other property of the solar wind. If we assume that there is a single or primary physical mechanism and that Halley's DE's are representative, efforts at simulation should concentrate on conditions at current sheet crossings. The mechanisms consistent with this result are sunward magnetic reconnection and tailward magnetic reconnection, if tailward reconnection can be triggered by the sector boundary crossing.

Brandt, John C.↗

Investigation of the Surface Stress in SiC and Diamond Nanocrystals by In-situ High Pressure Powder Diffraction Technique

The real atomic structure of nanocrystals determines key properties of the materials. For such materials the serious experimental problem lies in obtaining sufficiently accurate measurements of the structural parameters of the crystals, since very small crystals constitute rather a two-phase than a uniform crystallographic phase system. As a result, elastic properties of nanograins may be expected to reflect a dual nature of their structure, with a corresponding set of different elastic property parameters. We studied those properties by in-situ high-pressure powder diffraction technique. For nanocrystalline, even one-phase materials such measurements are particularly difficult to make since determination of the lattice parameters of very small crystals presents a challenge due to inherent limitations of standard elaboration of powder diffractograms. In this investigation we used our methodology of the structural analysis, the 'apparent lattice parameter' (alp) concept. The methodology allowed us to avoid the traps (if applied to nanocrystals) of standard powder diffraction evaluation techniques. The experiments were performed for nanocrystalline Sic and GaN powders using synchrotron sources. We applied both hydrostatic and isostatic pressures in the range of up to 40 GPa. Elastic properties of the samples were examined based on the measurements of a change of the lattice parameters with pressure. The results show a dual nature of the mechanical properties (compressibilities) of the materials, indicating a complex, core-shell structure of the grains.

Palosz, B.↗

Small Angle Neutron Scattering

Small Angle Neutron Scattering (SANS) probes structural details at the nanometer scale in a non-destructive way. This article gives an introduction to scientists who have no prior small-angle scattering knowledge, but who seek a technique that allows elucidating structural information in challenging situations that thwart approaches by other methods. SANS is applicable to a wide variety of materials including metals and alloys, ceramics, concrete, glasses, polymers, composites and biological materials. Isotope and magnetic interactions provide unique methods for labeling and contrast variation to highlight specific structural features of interest. In situ studies of a material s responses to temperature, pressure, shear, magnetic and electric fields, etc., are feasible as a result of the high penetrating power of neutrons. SANS provides statistical information on significant structural features averaged over the probed sample volume, and one can use SANS to quantify with high precision the structural details that are observed, for example, in electron microscopy. Neutron scattering is non-destructive; there is no need to cut specimens into thin sections, and neutrons penetrate deeply, providing information on the bulk material, free from surface effects. The basic principles of a SANS experiment are fairly simple, but the measurement, analysis and interpretation of small angle scattering data involves theoretical concepts that are unique to the technique and that are not widely known. This article includes a concise description of the basics, as well as practical know-how that is essential for a successful SANS experiment.

biomaterials↗

In situ deposits of copper and copper oxide containing condensation polyimide films

Novel copper-polyimide composites have been synthesized via simultaneous thermal decomposition of solid solutions of bis (trifluoroacetylacetonato) copper (II) and thermal cyclodehydration of polyimide acid. In contrast to conventional filled polymer composites which are prepared by dispersion of particles or fibers in a polymer matrix this study has yielded in general uniform Cu or CuO dispersions of very small particle size that reside near the film surface that was exposed to the atmosphere during curing. The nature of the copper deposit, the thickness of the copper deposit, and the polyimide overlayer which bonds the copper to the polymer substrate depend on the curing atmosphere used. A variety of analytical surface methods along with thermogravimetric analysis and variable temperature (surface and volume) electrical resistivity measurements have been used to characterize these thin, flexible copper doped polyimide films.

Porta, G. M.↗

Experimental analysis of convective drying of paper and board

Conventional multi-cylinder drying of paper and board involves a mixture of conductive drying from steam-heated dryer cylinders and convective drying by the flow of heated air over the surface of the paper web in the pockets. Pocket ventilation is a critical component in assisting heat and mass transfer during the drying process but is the primary contributor towards removing evaporated water from the web. Air temperature, velocity, and humidity are critical parameters involved in the convective drying process. This paper covers an experimental study involving the design and development of a small lab-scale setup for convective drying of various grades of paper and board, monitoring multiple parameters like paper temperature, moisture content, air humidity, temperature, and velocity measured in situ as the drying proceeds with continuous and accurate sampling capabilities for all parameters in the sample and the system. Instantaneous drying rates, heat, and mass transfer coefficients were also deduced for every time step till the paper completely dried. Furthermore, the coefficients obtained were also reported in the form of dimensionless correlations, and the results were compared against traditional correlations used in the modelling of paper drying. Furthermore, this data will be useful in process development, modelling, design, and the paper drying process simulation.

42 ENGINEERING↗

Monitoring plasma treatment of thin films by surface plasmon resonance

We report the surface plasmon resonance (SPR) measurements during plasma treatment of thin films by an indigenously designed setup. From the measurements on Al (6.3 nm)/Ag (38 nm) bi-layer at a pressure of 0.02 mbar, the SPR position was found to be shifted by ∼20° after a plasma treatment of ∼7 h. The formation of oxide layers during plasma oxidation was confirmed by glancing angle x-ray diffraction (GXRD) measurements. Combined analysis of GXRD and SPR data confirmed that while top Al layer enables controlling plasma oxidation of Ag, the setup enables monitoring the same. The setup designed is a first of its kind for in situ SPR studies where creation of low pressure is a prerequisite.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ investigations of laser and thermally modified As{sub 2}S{sub 3} nanolayers: Synchrotron radiation photoelectron spectroscopy and density functional theory calculations

As-deposited, annealed, and in situ As{sub 2}S{sub 3} nanolayers, illuminated by blue (405 nm) and red (650 nm) laser light, were studied using synchrotron radiation photoelectron spectroscopy and DFT electronic structure calculations. Changes in composition and local atomic coordination occurring in the irradiated region of As{sub 2}S{sub 3} films were monitored by analysis of As 3d and S 2p core levels. These studies show that both the thermal treatment and the red laser illumination of As{sub 2}S{sub 3} nanolayers decrease the concentration of homopolar (As-As and S-S) bonds. From the other hand, an increasing concentration of As-rich structural units (s.u.) with a homopolar As-As bond was observed under in situ blue laser illumination of As{sub 2}S{sub 3} nanolayers. Molecular orbital energies were calculated for different As- and S-centered s.u. and used for the interpretation of the core levels and valence band spectra. The surface local structure of the As{sub 2}S{sub 3} nanolayers and its photoinduced transformation are discussed in detail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Float Zone Experiments in Space

The objective of this work has been to evaluate whether or not Marangoni flow could be suppressed in molten metals by the presence of very thin oxide films. Experimental work has been carried out on molten Sn under UHV conditions. A disk floating zone arrangement was developed to allow in situ Auger examination of molten surfaces. An electron energy loss technique was developed which allows detection of continuous tin oxide films of 6 A or greater. Experiments were planned to detect the effects of oxide formation upon Marangoni flow by measuring: (1) temperature profiles, (2) solid liquid interface shapes, (3) macrosegregation, and (4) the onset of oscillatory Marangoni flow by detecting oscillating temperature variations. Work on (4) showed that oscillatory temperature variations of frequency or = 10 Hz were not present in the disk float zone geometry under conditions of Ma = 4300 with an oxide free molten surface. The disk float zone geometry was modeled with a finite element analysis and temperature and velocity profiles were determined.

Verhoeven, J. D.↗

Tracer-based Determination of Vortex Descent in the 1999/2000 Arctic Winter

A detailed analysis of available in situ and remotely sensed N2O and CH4 data measured in the 1999/2000 winter Arctic vortex has been performed in order to quantify the temporal evolution of vortex descent. Differences in potential temperature (theta) among balloon and aircraft vertical profiles (an average of 19-23 K on a given N2O or CH4 isopleth) indicated significant vortex inhomogeneity in late fall as compared with late winter profiles. A composite fall vortex profile was constructed for 26 November 1999, whose error bars encompassed the observed variability. High-latitude extravortex profiles measured in different years and seasons revealed substantial variability in N2O and CH4 on theta surfaces, but all were clearly distinguishable from the first vortex profiles measured in late fall 1999. From these extravortex-vortex differences we inferred descent prior to 26 November: as much as 397 plus or minus 15 K (lsigma) at 30 ppbv N2O and 640 ppbv CH4, and falling to 28 plus or minus 13 K above 200 ppbv N2O and 1280 ppbv CH4. Changes in theta were determined on five N2O and CH4 isopleths from 26 November through 12 March, and descent rates were calculated on each N2O isopleth for several time intervals. The maximum descent rates were seen between 26 November and 27 January: 0.82 plus or minus 0.20 K/day averaged over 50- 250 ppbv N2O. By late winter (26 February to 12 March), the average rate had decreased to 0.10 plus or minus 0.25 K/day. Descent rates also decreased with increasing N2O; the winter average (26 November to 5 March) descent rate varied from 0.75 plus or minus 0.10 K/day at 50 ppbv to 0.40 plus or minus 0.11 K/day at 250 ppbv. Comparison of these results with observations and models of descent in prior years showed very good overall agreement. Two models of the 1999/2000 vortex descent, SLIMCAT and REPROBUS, despite theta offsets with respect to observed profiles of up to 20 K on most tracer isopleths, produced descent rates that agreed very favorably with the inferred rates from observation.

Greenblatt, Jeffrey B.↗

Predicting melt pool depth and grain length using multiple signatures from in-situ single camera two-wavelength imaging pyrometry for laser powder bed fusion

In laser powder bed fusion (LPBF), the in-situ process signatures are known to have a direct correlation with the microstructural properties of the solidified melt pool (MP). It is known that the MP cooling and heating rates, and laser processing parameters can critically determine the grain structure and thereby affect the part properties. The objective of this work is to study the feasibility of using in-process, high-speed imaging pyrometry for evaluating the solidified MP properties “below” the surface, such as depth and microstructural properties. To accomplish this, we employ an in-house single camera-based two-wavelength imaging pyrometry (STWIP) system for monitoring the printing of single-scan tracks with Inconel 718 on a commercial LPBF printer (EOS M290). Further, the lab designed STWIP system is a coaxial high-speed (>10,000 fps) imaging system capable of monitoring MP temperature, morphology, and intensity profiles. The temperature measurements from STWIP are emissivity independent. The STWIP measured MP signatures of the printed tracks are correlated with the ex-situ microscopy characterized MP depth and the average grain lengths. From the data analysis, using support vector machine (SVM)-based regression models, we found that the MP temperature signatures are crucial for an accurate prediction of MP depth and the grain length, thus validating the novelty and necessity of the developed in-situ monitoring methods and analysis.

36 MATERIALS SCIENCE↗

Charges on a suspended silicon nitride membrane under a high-energy electron beam

Thin silicon nitride (SiN x ) membranes are widely used in gas and liquid phase transmission electron microscopy (TEM) and as phase plates to enhance imaging contrast. SiN x contains trap sites for both positive and negative charges, which can be manipulated by high-energy electron irradiation, external potential biasing, or light exposure. Charge accumulation on the membrane can significantly affect in situ TEM processes, including chemical and electrochemical reactions, nanoparticle dynamics, and catalytic activity, or introduce unwanted phase shifts when used as a phase plate. Here, in this study, charge accumulation on suspended SiN x membranes was investigated using off-axis electron holography combined with model-free charge analysis, supported by custom finite element analysis (FEA) simulations. An average residual positive charge density of approximately 2.8 × 10 −4 C m −2 was measured. Localized and stable regions of both positive and negative charges were identified on the membrane. The global positive and localized positive/negative charges give rise to strong electric fields and electroosmotic slip velocities at the membrane surface, which are sufficient to induce non-Brownian particle behavior and directional fluid flow, offering a physical explanation for previously observed anomalies in particle dynamics, nucleation, and growth during gas and liquid phase TEM experiments. These results provide a benchmark for understanding charge behavior at SiNx interfaces in gas and liquid phase TEM. Furthermore, the FEA simulations establish a framework for future investigations into charge distribution, electrostatic potentials, and electrical double layers at solid–liquid interfaces, particularly in complex geometries and chemically dynamic environments.

Suspended silicon↗

Surface evolution of perfluoropolyether film at high speed quasi-contact conditions

Nanoscale analysis characterized by microscopy with atomic resolution demand that the targeted surface remains nearly static. Therefore, the interaction between two fast moving surfaces requires a unique methodology to capture its dynamics when contacts are of nominal area on the order of 100 μm{sup 2} but only a few angstroms in depth. We present a contact study of the head-disk interface in hard disk drives, which consists of a disk surface coated with a molecularly thin perfluoropolyether lubricant and a slider surface moving slightly separated from it with a relative velocity of 20 m/s and with 10 nm spacing. By investigating the slider dynamics and lubricant topography in-situ, we disclose that high-speed contact initiates when the slider shears the top surface of the lubricant. Such contact can pile up molecules a few angstroms high as “moguls” or annihilate existing ones through a 5–10 Å interference. The transitional spacing regime of mogul evolution is defined as “quasi-contact,” and it is the initial contact in the fast sliding interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracer-Based Determination of Vortex Descent in the 1999-2000 Arctic Winter

A detailed analysis of available in situ and remotely sensed N2O and CH4 data measured in the 1999-2000 winter Arctic vortex has been performed in order to quantify the temporal evolution of vortex descent. Differences in potential temperature (theta) among balloon and aircraft vertical profiles (an average of 19-23 K on a given N2O or CH4 isopleth) indicated significant vortex inhomogeneity in late fall as compared with late winter profiles. A composite fall vortex profile was constructed for November 26, 1999, whose error bars encompassed the observed variability. High-latitude, extravortex profiles measured in different years and seasons revealed substantial variability in N2O and CH4 on theta surfaces, but all were clearly distinguishable from the first vortex profiles measured in late fall 1999. From these extravortex-vortex differences, we inferred descent prior to November 26: 397+/-15 K (1sigma) at 30 ppbv N2O and 640 ppbv CH4, and 28+/-13 K above 200 ppbv N2O and 1280 ppbv CH4. Changes in theta were determined on five N2O and CH4 isopleths from November 26 through March 12, and descent rates were calculated on each N2O isopleth for several time intervals. The maximum descent rates were seen between November 26 and January 27: 0.82+/-0.20 K/day averaged over 50-250 ppbv N2O. By late winter (February 26-March 12), the average rate had decreased to 0.10+/-0.25 K/day. Descent rates also decreased with increasing N2O; the winter average (November 26-March 5) descent rate varied from 0.75+/-0.10 K/day at 50 ppbv to 0.40+/-0.11 K/day at 250 ppbv. Comparison of these results with observations and models of descent in prior years showed very good overall agreement. Two models of the 1999-2000 vortex descent, SLIMCAT and REPROBUS, despite theta offsets with respect to observed profiles of up to 20 K on most tracer isopleths, produced descent rates that agreed very favorably with the inferred rates from observation.

Greenblatt, Jeffery B.↗

Laser Ablation Electrodynamic Ion Funnel for In Situ Mass Spectrometry on Mars

A front-end instrument, the laser ablation ion funnel, was developed, which would ionize rock and soil samples in the ambient Martian atmosphere, and efficiently transport the product ions into a mass spectrometer for in situ analysis. Laser ablation creates elemental ions from a solid with a high-power pulse within ambient Mars atmospheric conditions. Ions are captured and focused with an ion funnel into a mass spectrometer for analysis. The electrodynamic ion funnel consists of a series of axially concentric ring-shaped electrodes whose inside diameters (IDs) decrease over the length of the funnel. DC potentials are applied to each electrode, producing a smooth potential slope along the axial direction. Two radio-frequency (RF) AC potentials, equal in amplitude and 180 out of phase, are applied alternately to the ring electrodes. This creates an effective potential barrier along the inner surface of the electrode stack. Ions entering the funnel drift axially under the influence of the DC potential while being restricted radially by the effective potential barrier created by the applied RF. The net result is to effectively focus the ions as they traverse the length of the funnel.

Johnson, Paul V.↗

Lunar Science Investigations and Exploration in Celestial Mapping System

Introduction: As NASA expands the mission portfolio on the lunar surface, there is a need for applications with a broad range of analytical and functional capabilities that can be simultaneously deployed onto multiple mobile and desktop platforms to perform in-situ operations and hence enabling extensive Lunar exploration. Celestial Mapping System (CMS) [1,2] is developed to address the need for tools for science investigations, mission planning, operations and support for planetary sciences. Built on top of NASA WorldWind libraries, CMS can be simultaneously deployed onto multiple platforms, has the flexibility to update to the latest imagery and terrain datasets as they are being acquired (in real time) before and/or during the exploration mission and has the potential to enable traverse path planning suited for rovers, EVA and surface mobility units. It can provide critical functionalities such as equipment planning and optimized placement on Lunar surface, line of sight analysis to inform the coverage area for various equipment, powerful measurement tools based on 3D terrain, 3D COLLADA models to represent rovers, humans and equipment, visualization of derived mapping products (e.g. resource maps), and a data engine for hosting new observations that are not available in other contemporary lunar data tools [1]. Visualization of PSRs: The current presentation focuses on the work performed by the authors, to consume a unique dataset of super-enhanced images of the permanently shadowed regions (PSRs) at the lunar poles which were produced by the Hyper-effective nOise Removal U-net Software (HORUS) tool [3]. This tool was developed in direct support of NASA's VIPER and Artemis programs to enhance the extremely low-light images of the interior of PSRs and provide the first-time ability to see within these regions at and discern surface features (i.e. boulders and craters) down to 3 meters in size. We focused on the region near Nobili crater near Lunar south pole, selected site for VIPER mission and stitched several images to create a high-resolution map within one of the PSR of Nobile crater. Line of Sight Analysis and Traverse Planning in PSRs: We have developed an in-built line of sight analysis (LOS) tool in CMS that analyzes the terrain profile and obstructions and provides the visibility of a given terrain for a remote observer. This tool was utilized to perform viewshed analysis to investigate the area inside the PSR, a remote observer such as a rover could see without actually crossing the region. Figure 1 shows the viewshed analysis on the PSR in Nobile region. The yellow pin shows the observer location outside the PSR. The yellow area shows the visible part of PSR. The obstructed area with no visibility for the observer is shown in red. Figure 1: (left) PSR image on top of a high-resolution mosaic of sunlit images of a crater, in Nobile region (right) Viewshed Analysis of the same PSR with observer location shown by yellow pin. This analysis was extended further to set different heights for various observers and then perform the viewshed analysis. Combining the different visibility profiles can help designing improved traverses within the crater. Future plans: Eventually, HORUS datasets will be integrated into CMS as a layer in selected lunar polar regions. Hazard Maps will then be created based on terrain analysis in those regions. This integration will enable multiple scientific and exploration applications, such as designing traverses within PSRs, analyzing potential landing and science mission targets, investigating the meter-scale geomorphology of PSRs, including craters, boulder, surface roughness, mass wasting features and other indications of the presence of water-ice and other volatiles. Acknowledgments: CMS developers team including Kaitlyn J. Dickinson, Tyler A. Lucarz, Tyler W. Choi from USRA, NASA WorldWind Advisory team including Mark Peterson and Guillermo Miguel Del Castillo, HORUS team member V.T. Bickel, Robinson, M., LRO MOON LROC 2 EDR V1.0, LRO-L-LROC-2-EDR-V1.0, NASA Planetary Data System (PDS), 2009. https://doi.org/10.17189/1520643 References: [1] https://celestial.arc.nasa.gov [2] Agrawal et. al. “Celestial Mapping System for Lunar Surface Mapping and Analytics”, Lunar Surface Innovation Consortium, 2021 [3] Bickel V. et al. (2021) Nat Commun 12, 5607

Lunar Mapping↗

The Effect of a Planetary Surface Penetrator on the Soil Column Surrounding the Impacting Body

A prototype penetrator instrument was impacted into a dry lake bed. Laboratory studies of the soil surrounding the penetrator revealed that the soil was contaminated by paint and metal from the penetrator's casing. Paint pigment rich in titanium and sulfur was found in the adjacent soil. The highly mobile paint pigment migrated onto viewing ports in the penetrator's exterior. Bulk analysis of the soil adjacent to the impactor showed a significant increase in both elements, as well as the presence of metal chips from the casing and nose cone. It is recommended that great care be taken in the use of coating materials and the metal alloys selected for the penetrator's exterior, or the accuracy of any experiment requiring an uncontaminated in situ sample may be adversely affected.

Blanchard, Maxwell B.↗

Titan In-situ Resource Utilization (ISRU) Sample Return (TISR)

Titan is unique in the outer solar system in that it is the only moon with a thick atmosphere, and the only body in the solar system outside the Earth with liquid seas on its surface. The Titanian oceans, however, are seas of liquid hydrocarbons, and the rocks on the surface are solid water ice. Like other icy Moons of the outer solar system, beneath the ice crust, Titan also has a subsurface ocean. Rodriguez et al. refer to it as the “world with two oceans”, an organic-rich body with interior-surface-atmosphere interactions that are comparable in complexity to the Earth. [1] Titan is scientifically fascinating in many ways [2], [3], [4]. The Compass Team will emphasize just one here: Titan is a high priority target for astrobiology [4] [5] [6] [7] [8] [9] [10] [11]. It is a world with a surface and atmosphere rich in the complex organic compounds known as tholins. A detailed understanding of the nature of these complex compounds will require an analysis using a full laboratory on Earth. Because of its value to understanding the organic compounds of the outer solar system which may be the primordial building-blocks of life, return of samples from Titan to laboratories on Earth will be the primary goal of this mission. While this would give unprecedented science return, returning even a small sample from Titan using conventional technology would be tremendously difficult. Saturn is almost a billion miles from the Earth, about thirteen times farther than Mars. A return mission to Saturn requires such a large total-mission ∆V that, with conventional technology, the mass ratios required are prohibitive. Such a sample return would truly be “mission incredible.” But to date, a sample return mission from so distant a target has been assumed to be, not merely incredible, but mission impossible. The Compass Team has proposed [2] [12] that by manufacturing the propellant for the return to Earth using the resources available on Titan, such a mission becomes possible. The task of this report is to show that it is reasonable with credible space technology.

Titan↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (~13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ~100 μm spot on a target at a working distance of ~48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ~370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ~ 800 – 4000 cm -1 (250 to 273 nm) and the fluorescence region (274 to ~370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗