Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

BioSentinel: Monitoring DNA Damage Repair Beyond Low Earth Orbit on a 6U Nanosatellite

We are designing and developing a 6U nanosatellite as a secondary payload to fly aboard NASAs Space Launch System (SLS) Exploration Mission (EM) 1, scheduled for launch in late 2017. For the first time in over forty years, direct experimental data from biological studies beyond low Earth orbit (LEO) will be obtained during BioSentinels 12- to 18-month mission. BioSentinel will measure the damage and repair of DNA in a biological organism and allow us to compare that to information from onboard physical radiation sensors. This data will be available for validation of existing models and for extrapolation to humans.The BioSentinel experiment will use the organism Saccharomyces cerevisiae (yeast) to report DNA double-strand-break (DSB) events that result from space radiation. DSB repair exhibits striking conservation of repair proteins from yeast to humans. The flight strain will include engineered genetic defects that prevent growth and division until a radiation-induced DSB activates the yeasts DNA repair mechanisms. The triggered culture growth and metabolic activity directly indicate a DSB and its repair. The yeast will be carried in the dry state in independent microwells with support electronics. The measurement subsystem will sequentially activate and monitor wells, optically tracking cell growth and metabolism. BioSentinel will also include TimePix radiation sensors implemented by JSCs RadWorks group. Dose and Linear Energy Transfer (LET) data will be compared directly to the rate of DSB-and-repair events measured by the S. cerevisiae biosentinels. BioSentinel will mature nanosatellite technologies to include: deep space communications and navigation, autonomous attitude control and momentum management, and micropropulsion systems to provide an adaptable nanosatellite platform for deep space uses.

cosmic rays↗

Development of an Extreme Environment Materials Research Facility at Princeton

The need for a fundamental understanding of material response to a neutron and/or high heat flux environment can yield development of improved materials and operations with existing materials. Such understanding has numerous applications in fields such as nuclear power (for the current fleet and future fission and fusion reactors), aerospace, and other research fields (e.g., high-intensity proton accelerator facilities for high energy physics research). A proposal has been advanced to develop a facility for testing various materials under extreme heat and neutron exposure conditions at Princeton. The Extreme Environment Materials Research Facility comprises an environmentally controlled chamber (48 m^3) capable of high vacuum conditions, with extreme flux beams and probe beams accessing a central, large volume target. The facility will have the capability to expose large surface areas (1 m^2) to 14 MeV neutrons at a fluence in excess of 10^13 n/s. Depending on the operating mode. Additionally beam line power on the order of 15-75 MW/m2 for durations of 1-15 seconds are planned... The multi-second duration of exposure can be repeated every 2-10 minutes for periods of 10-12 hours. The facility will be housed in the test cell that held the Tokamak Fusion Test Reactor (TFTR), which has the desired radiation and safety controls as well as the necessary loading and assembly infrastructure. The facility will allow testing of various materials to their physical limit of thermal endurance and allow for exploring the interplay between radiation-induced embrittlement, swelling and deformation of materials, and the fatigue and fracturing that occur in response to thermal shocks. The combination of high neutron energies and intense fluences will enable accelerated time scale studies. The results will make contributions for refining predictive failure modes (modeling) in extreme environments, as well as providing a technical platform for the development of new alloys, new materials, and the investigation of repair mechanisms. Effects on materials will be analyzed with in situ beam probes and instrumentation as the target is exposed to radiation, thermal fluxes and other stresses. Photon and monochromatic neutron fluxes, produced using a variable-energy (4-45 MeV) electron linac and the highly asymmetric electron-positron collisions technique used in high-energy physics research, can provide non-destructive, deep-penetrating structural analysis of materials while they are undergoing testing. The same beam lines will also be able to generate neutrons from photonuclear interactions using existing Bremsstrahlung and positrons on target quasi-monochromatic gamma rays. Other diagnostics will include infrared cameras, residual gas analyzer (RGA), and thermocouples; additional diagnostic capability will be added.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bunch Compression of Flat Beams

Flat beams can be produced via a linear manipulation of canonical-angular-momentum (CAM) dominated beams using a set of skew-quadrupole magnets. Recently, such beams were produced at Fermilab Accelerator Science and Technology (FAST) facility 1. In this paper we report the results of flat beam compression study in a magnetic chicane at an energy E ~ 32 MeV. Additionally, we investigate the effect of energy chirp in the round-to-flat beam transform. The experimental results are compared with numerical simulations.

43 PARTICLE ACCELERATORS↗

SU-F-T-72: Experimental Determination of the Positionuncertainties for ROOS Ionization Chambers in Clinical Electron Beams

Purpose: National and international dosimetry protocols assume a position accuracy for ionization chambers of less than 0.2mm. To follow this precept the manufacturer PTW-Freiburg introduced a positioning assistance system (TRUFIX) for their particular ion chambers. Aim of this study is an experimental investigation of the positioning uncertainties for ROOS-type ionization chambers. Methods: For all measurements a linear accelerator Elekta Synergie was used. The experiments were performed in a water-phantom. To collimate the electron beam a 10×10cm{sup 2} applicator was installed. All measured depth dose curves were normalized to their maximum. In all cases the TRUFIX system was applied for chamber positioning. For the first measurement series, to determine the positioning reproducibility of a ROOS chamber, one person placed the chamber three times in a 6 MeV electron beam. The mean value of this three measurements was the reference for further six random persons who repeated this procedure. The results were compared for different depths (R{sub 50}, z{sub ref} and R{sub p}). To investigate the impact of different individual chambers of the same type 10 different ROOS chambers were placed by the same person in a 6, 12 and 18MeV electron beam and the measured reference depths z{sub ref} were compared. Results: The absolute positioning reproducibility is less than 0.1mm for the same person. The positioning uncertainties are increasing up to +/−0.3mm if different persons perform the chamber’s positioning within the water phantom. The comparison of the 10 different ROOS chambers resulted in reference depths z{sub ref} with deviations in the range of +/−0.45mm for all energies. Conclusion: The position accuracy of 0.2mm can be fulfilled with the TRUFIX system. The comparison of the 10 different ROOS ionization chambers showed noticeable deviations in the determined reference depth. The impact of a positioning uncertainty of about 0.3–0.4mm on the total perturbation correction will be considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of a linear surface wave plasma source for tin removal in an extreme ultraviolet source

Tin deposition mitigation employs hydrogen radicals and ions, formed in a hydrogen plasma, to interact with tin to form tin hydride (SnH 4 ) in the gaseous state, which is then pumped away. Surface wave plasma (SWP) technology developed at Illinois generates hydrogen radicals and ions, resulting in tin etch rates that are high enough to keep extreme ultraviolet (EUV) lithographic tools clean. An advantage of an SWP antenna is the ability to generate a high density of hydrogen radicals and hydrogen ions directly at the desired etching location. In situ etching of tin enables high availability EUV tools by maintaining high reflectivity of the multilayer mirror of the collector. Additionally, the SWP is characterized with low ion energies and low electron temperature, such that the multilayer mirror does not suffer any damage from sputtering or implantation of hydrogen ions during operation. Here, experiments elucidating the fundamental processes of tin removal are conducted by varying pressure, power, surface temperature, and gas flow rate in order to observe the etch rate behavior. Our results have shown that the presence of hydrogen ions increases etch rates because ion bombardment weakens Sn–Sn bonds, which, in turn, allows for a higher rate of chemical etching by the radicals. The ion bombardment reduces the number of radicals needed to etch a single tin atom to the range of 10 2 –10 3 . The linear SWP antenna yields plasma densities on the order of 10 17 to 10 18 m -3 and radical densities on the order of 10 18 to 10 19 m -3 , allowing for greater utilization of ion etch enhancement. Etch rates of up to 200 nm/min have been achieved. The surface temperature of the samples is an important factor in the etching process such that the decrease in the surface temperature increases the etch rates and decreases the hydrogen desorption rates. In addition, a kinetic etch model is developed to explain the behavior of etch rates as a function of surface temperature. Furthermore, results from experiments performed in an Illinois NXE:3100 chamber will be discussed.

42 ENGINEERING↗

Designing order–disorder transformation in high-entropy ferritic steels

Order–disorder transformations hold an essential place in chemically complex high-entropy ferritic steels (HEFSs) due to their critical technological application. The chemical inhomogeneity arising from mixing of multi-principal elements of varying chemistry can drive property altering changes at the atomic scale, in particular short-range order. Using density-functional theory-based linear-response theory, we predict the effect of compositional tuning on the order–disorder transformation in ferritic steels—focusing on Cr–Ni–Al–Ti–Fe HEFSs. We show that Ti content in Cr–Ni–Al–Ti–Fe solid solutions can be tuned to modify short-range order that changes the order–disorder path from BCC-B2 (Ti atomic-fraction = 0) to BCC-B2-L2 1 (Ti atomic-fraction > 0) consistent with existing experiments. Our study suggests that tuning degree of SRO through compositional variation can be used as an effective means to optimize phase selection in technologically useful alloys.

36 MATERIALS SCIENCE↗

Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators

Purpose: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. Methods: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm{sup 3} and a diode of surface area 0.64 mm{sup 2}. The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10x10 cm{sup 2} field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. Results: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a {+-}0.7 mm variation in the 80%-20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping parameter between in-plane and cross-plane measurements. This is primarily due to the directional difference in penumbral width measured by the FC65 chamber, which can more than double in profiles obtained with the detector stem parallel compared to perpendicular to the scan direction. For the more symmetric CC13 chamber the variation was only 3% between in-plane and cross-plane measurements. Conclusions: The authors have shown that the detector response varies with detector type, depth, SSD, and detector scan direction. In-plane vs cross-plane scanning can require calculation of a direction dependent response function. The effect of a 10% overall variation in the response function, for an ionization chamber, translates to a small deviation in the penumbra from that of the Edge detector measured profile when deconvolved. Due to the uncertainties introduced by deconvolution the Edge detector would be preferable in obtaining an approximation of the true profile, particularly for field sizes where the energy dependence of the diode can be neglected. However, an averaged response function could be utilized to provide a good approximation of the true profile for large ionization chambers and for larger fields for which diode detectors are not recommended.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Messaging with Cost-Optimized Interstellar Beacons

On Earth, how would we build galactic-scale beacons to attract the attention of extraterrestrials, as some have suggested we should do? From the point of view of expense to a builder on Earth, experience shows an optimum trade-off. This emerges by minimizing the cost of producing a desired power density at long range, which determines the maximum range of detectability of a transmitted signal. We derive general relations for cost-optimal aperture and power. For linear dependence of capital cost on transmitter power and antenna area, minimum capital cost occurs when the cost is equally divided between antenna gain and radiated power. For nonlinear power-law dependence, a similar simple division occurs. This is validated in cost data for many systems; industry uses this cost optimum as a rule of thumb. Costs of pulsed cost-efficient transmitters are estimated from these relations by using current cost parameters ($/W, $/sq m) as a basis. We show the scaling and give examples of such beacons. Galactic-scale beacons can be built for a few billion dollars with our present technology. Such beacons have narrow "searchlight" beams and short "dwell times" when the beacon would be seen by an alien observer in their sky. More-powerful beacons are more efficient and have economies of scale: cost scales only linearly with range R, not as R(exp 2), so number of stars radiated to increases as the square of cost. On a cost basis, they will likely transmit at higher microwave frequencies, -10 GHz. The natural corridor to broadcast is along the galactic radius or along the local spiral galactic arm we are in. A companion paper asks "If someone like us were to produce a beacon, how should we look for it?"

Benford, James↗

Drag force to all orders in gradients

We study the energy loss of a heavy quark slowly moving through an evolving strongly coupled plasma. We use the linearized fluid/gravity correspondence to describe small perturbations of the medium flow with general spacetime dependence. This all order linearized hydrodynamics results in a drag force exerted on a heavy quark even when it is at rest with the fluid element. We show how the general contribution to the drag force can be derived order by order in the medium velocity gradients and provide explicit results valid up to the third order. We then obtain an approximate semi-analytic result for the drag force to all orders in the gradient expansion but linearized in the medium velocity. Thus, the effects of a class of hydrodynamic gradients on the drag force are re-summed, giving further insight into the dissipative properties of strongly coupled plasmas. The all order result allows us to study the drag force in the non-hydrodynamic regime of linear medium perturbations that vary rapidly in space and time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear longitudinal compression of short laser pulses in the atmosphere

Propagation of short and intense laser beams in the atmosphere is considered for the purpose of identifying the temporal compression. The conditions and validity of linear and nonlinear compression theories are discussed. The effects of chirping and pulse power in the preionization regime are deliberated. The fact that the linear theory cannot explain the pulse compression in the atmosphere is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-accuracy X-ray detector calibration based on cryogenic radiometry

Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact cosmic ray detector for unattended atmospheric ionization monitoring

Two vertical cosmic ray telescopes for atmospheric cosmic ray ionization event detection are compared. Counter A, designed for low power remote use, was deployed in the Welsh mountains; its event rate increased with altitude as expected from atmospheric cosmic ray absorption. Independently, Counter B's event rate was found to vary with incoming particle acceptance angle. Simultaneous co-located comparison of both telescopes exposed to atmospheric ionization showed a linear relationship between their event rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Turbulent regimes in the tokamak scrape-off layer

The non-linear turbulent regimes in the tokamak scrape-off layer (SOL) are identified according to the linear instability responsible for the perpendicular transport. Four regions of the SOL operational parameters are determined where turbulence is driven by the inertial or resistive branches of the ballooning mode or of drift waves. The analysis, based on the linear electrostatic drift-reduced Braginskii equations, evaluates the pressure scale length self-consistently from the balance between plasma losses at the vessel and perpendicular turbulent transport. The latter is estimated by assuming that turbulence saturation occurs due to a local flattening of the plasma gradients and associated removal of the linear instability drive; it is also shown that transport is led by the mode that maximizes the ratio of the linear growth to the poloidal wavenumber. The methodology used to identify the turbulent regimes is confirmed by the results of non-linear simulations of SOL turbulence. The identification of the turbulent regimes, the predicted pressure scale length, and the poloidal wavenumber of the leading mode are in reasonable agreement with non-linear simulation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic study of the impact of the electron to ion heating ratio on the turbulent diffusion of highly charged impurities

A gyrokinetic study based on numerical and analytical calculations is presented, which computes the dependence of the turbulent diffusion of highly charged impurities on the ratio of the electron to the ion heat flux of the plasma. Nonlinear simulations show that the size of the turbulent diffusion of heavy impurities can vary by one order of magnitude with fixed total heat flux and is an extremely sensitive function of the electron to ion heat flux ratio. Numerical linear calculations are found to reproduce the nonlinear results. Thereby, a quasi-linear analytical approach is used to explain the origin of this dependence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Do chaotic field lines cause fast reconnection in coronal loops?

Over the past decade, Boozer has argued that three-dimensional (3D) magnetic reconnection fundamentally differs from two-dimensional reconnection due to the fact that the separation between any pair of neighboring field lines almost always increases exponentially over distance in a 3D magnetic field. According to Boozer, this feature makes 3D field-line mapping chaotic and exponentially sensitive to small non-ideal effects; consequently, 3D reconnection can occur without intense current sheets. We test Boozer's theory via ideal and resistive reduced magnetohydrodynamic simulations of the Boozer–Elder coronal loop model driven by sub-Alfvénic footpoint motions [A. H. Boozer and T. Elder, Phys. Plasmas 28, 062303 (2021)]. In this work, our simulation results significantly differ from their predictions. The ideal simulation shows that Boozer and Elder under-predict the intensity of current density due to missing terms in their reduced model equations. Furthermore, resistive simulations of varying Lundquist numbers show that the maximal current density scales linearly rather than logarithmically with the Lundquist number.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oscillatory growth behavior of multistream instabilities

Multistream instabilities in the one-dimensional Vlasov−Poisson system are studied numerically by using plasmas with multi-humped electron distributions. The evolution of the total wave energy of the plasma oscillations excited by (numerical) noise consists of transient, growth, and nonlinear saturation stages. It is found that, in the growth stage, the total wave energy oscillates for odd number of streams, but it does not oscillate for even number of streams. It is also found that different spectral (Fourier) modes can dominate different stages of the “linear” growth and nonlinear saturation stages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detector Fundamentals for Reachback Analysts

This presentation is a part of the DHS LSS spectroscopy course and provides an overview of the following concepts: detector system components, intrinsic and absolute efficiency, resolution and linearity, and operational issues and limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗