Search NASA⌕ Search

SEARCH · Search NASA

Results for “MODs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Effect of Compressibility on the Pressure and Forces Acting on a Modified NACA 65,3-019 Airfoil Having A 0.20-Chord Flap

An investigation has been conducted in the Langley rectangular high-speed tunnel to determine the effect of compressibility on the pressure distribution for a modified NACA 65,3-019 airfoil having a 0.20-chord flap. The investigation was made for an angle-of-attack range extending from -2 to 12 deg at .20 flap deflections from 0 to -12 deg. Test data were obtained for Mach numbers from 0.28 to approximately 0.74. The results show that the effectiveness of the trailing-edge-type control surface rapidly decreased and approached zero as the Mach number increased above the critical value.

AIRFOILS-NACA 65,3-019 (MOD )-MOMENTS & ORDINATES ↗

NASA’s Radioisotope Power Systems Program: Status Update

Radioisotope power systems (RPS) have safely been in use in the United States for over 60 years. RPS-enabled NASA missions have utilized space nuclear power to explore planets, moons, and interstellar space. This exploration resulted in changes to our understanding of our Solar System and our place within it. In 2010, NASA HQ established a NASA program to invest in RPS technologies and systems that could enable future missions. The RPS Program ensures the availability of RPS for the exploration of the solar system in environments where conventional solar or chemical power generation is impractical or impossible. The RPS Program, in partnership with the Department of Energy (DOE) Office of Nuclear Energy continues to operate as an interagency partnership to provide robust power system solutions to spacecrafts that conduct missions for exploration and science that otherwise would not be feasible. This paper provides a synopsis of current activities after well over a decade of formal interagency partnering.

Radioisotope↗

Volatile aldehyde emissions from “sub-ohm” vaping devices

"Sub-ohm" atomizers with reduced resistance can deliver more power than conventional electronic cigarettes. Typical battery outputs are 100 watts or more. These devices are particularly popular among young users, and can be a significant source of volatile carbonyls in the indoor environment. Emissions from next-generation sub-ohm vaping products were characterized by determining e-liquid consumption and volatile aldehydes emissions for several combinations of popular high-power configurations. Tests explored the effect of dilution air flow (air vent opening), puffing volume, and coil assembly configuration. The mass of liquid consumed per puff increased as the puff volume increased from 50 to 100 mL, then remained relatively constant for larger puff volumes up to 500 mL. This is likely due to mass transfer limitations at the wick and coil assembly, which reduced the vaporization rate at higher puff volumes. Carbonyl emission rates were systematically evaluated using a 0.15 Ω dual coil atomizer as a function of the puffing volume and dilution air flow, adjusted by setting the air vents to either 100% (fully open), 50%, 25%, or 0% (closed). The highest formaldehyde emissions were observed for the lowest puff volume (50 mL) when the vents 31 were closed (48 ng mg-1), opened at 25% (39 ng mg -1 ) and at 50% (32 ng mg -1 ).. By contrast, 50-mL puffs with 100% open vents, and puff volumes >100 mL for any vent aperture, generated formaldehyde yields of 20 ng mg -1 or lower, suggesting that a significant cooling effect resulted in limited carbonyl formation. Considering the effect of the coil resistance when operated at a voltage of 3.8 V, the amount of liquid evaporated per puff decreased as the resistance increased, in the order of 0.15 Ω > 0.25 Ω > 0.6 Ω consistent with decreasing aerosol temperatures measured at the mouthpiece. Three different configurations of 0.15 Ω coils (dual, quadruple and octuple) were evaluated, observing significant variability. No clear trend was found between carbonyl emission rates and coil resistance or configuration, with highest emissions corresponding to a 0.25 Ω dual coil atomizer. Carbonyl emission rates were compared with those determined using the same methodology for conventional e-cigarettes (lower power tank systems), observing overall lower yields for the sub-ohm devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poloidally and radially resolved parallel D{sup +} velocity measurements in the DIII-D boundary and comparison to neoclassical computations

First measurements of the D{sup +} parallel velocity, V{sub ||}{sup D+}, in L-mode discharges in the DIII-D [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] tokamak boundary region at two poloidal locations, {theta}{approx}0 deg. and {theta}{approx}255 deg., made using Mach probes, feature a peak with velocities of up to 80 km/s at the midplane last closed flux surface (LCFS), as high as ten times the charge exchange recombination C{sup 6+} toroidal velocity, V{sub {phi}}{sup C6+}, in the same location. The V{sub ||}{sup D+} profiles are very asymmetric poloidally, by a factor of 8-10, and feature a local peak at the midplane. This peak, 1-2 cm wide, is located at or just inside the LCFS, and it suggests a large source of momentum in that location. This momentum source is quantified at {approx}0.31 N m by using a simple momentum transport model. This is the most accurate measurement of the effects of so called 'intrinsic' edge momentum source to date. The V{sub ||}{sup D+} measurements are quantitatively consistent with a purely neoclassical computational modeling of V{sub ||}{sup D+} by the code NEO[E. A. Belli and J. Candy, Plasma Phys. Controlled Fusion 50, 095010 (2008)], using V{sub {phi}}{sup C6+} as input, for {rho}{approx}0.7-0.95 at the two poloidal locations, where V{sub ||}{sup D+} measurements exist. The midplane NEO-calculated V{sub ||}{sup D+} grows larger than V{sub ||}{sup C6+} in the steeper edge gradient region and trends to agreement with the probe-measured V{sub ||}{sup D+} data near {rho}{approx}1, where the local V{sub ||}{sup D+} velocity peak exists. The measurements and computations were made in OH and L-mode discharges on an upper single null, with ion {nabla}B{sub T} drift away from the divertor. The rotating layer finding is similar in auxiliary heated discharges with and without external momentum input, except that at higher density the edge velocity weakens.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Successive Gain Of Insulator Proteins In Arthropod Evolution

Alteration of regulatory DNA elements or their binding proteins may have drastic consequences for morphological evolution. Chromatin insulators are one example of such proteins and play a fundamental role in organizing gene expression. While a single insulator protein, CTCF (CCCTC-binding factor), is known in vertebrates, Drosophila melanogaster utilizes six additional factors. We studied the evolution of these proteins and show here that—in contrast to the bilaterian-wide distribution of CTCF—all other D. melanogaster insulators are restricted to arthropods. The full set is present exclusively in the genus Drosophila whereas only two insulators, Su(Hw) and CTCF, existed at the base of the arthropod clade and all additional factors have been acquired successively at later stages. Secondary loss of factors in some lineages further led to the presence of different insulator subsets in arthropods. Thus, the evolution of insulator proteins within arthropods is an ongoing and dynamic process that reshapes and supplements the ancient CTCF-based system common to bilaterians. Expansion of insulator systems may therefore be a general strategy to increase an organism’s gene regulatory repertoire and its potential for morphological plasticity.

59 BASIC BIOLOGICAL SCIENCES↗

Wind-Tunnel Investigation of the Effect of Tab Balance on Tab and Control-Surface Characteristics

An investigation was conducted to furnish data on the effect of tab balance on tab and control-surface characteristics. The airfoil tested had a modified NACA 65(1)-012 contour with a plain flap having a chord equal to 25 percent of the wing chord and with a tab having a chord equal to 25 percent of the flap chord and having several nose shapes and overhang lengths. The results of the investigation indicated that, in general, tab balance affected tab hinge-moment characteristics in much the same manner that flap balance affects flap hinge-moment characteristics. A moderate amount of tab balance did not seem to have any adverse effect on flap hinge-moment characteristics.

TABS, AILERON↗