Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Evaluation of HAN-TEAN Stabilizers using Microcalorimetry

HAN-TEAN (hydroxylammonium nitrate - triethanolammonium nitrate - in water) is being considered for various propellant applications. This propellant has advantages in terms of insensitivity to impact and fire, low vapor pressure and environmentally benign reaction products. One office concerns with HAN-TEAN is its stability and shelf-life, especially when contaminated with trace metals. Stabilizer systems, consisting of anti-oxidants and/or chealating agents were investigated for their ability to control the decomposition of HAN-TEAN. Isothermal microcalorimetry, an ultrasensitive heat measurement technique, was used to monitor the decomposition of HANTEAN at near ambient temperatures. Isothermal microcalorimetry measures the heat flow from a reaction vessel into a surrounding heat sink. Microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry (ARC) or differential scanning calorimetry (DSC) for measuring heat flow. Samples of HAN-TEAN containing the stabilizers were spiked with 50 ppm iron and the heat evolution monitored for a period of at least 30 days. Ten stabilizer combinations were tested and the rates of HAN-TEAN decomposition were lowered by 74 to 95 percent in the presence of iron.

Hornung, Steven D.↗

Transonic Experimental Observations of Abrupt Wing Stall on an F/A-18E Model (Invited)

A transonic wind tunnel test of an 8% F/A-18E model was conducted in the NASA Langley Research Center (LaRC) 16 ft Transonic Tunnel (16-ft TT) to investigate on-surface flow physics during stall. The technical approach employed focused on correlating static (or time-averaged) and unsteady wind-tunnel test data to the unsteady wing-stall events using force, moment, pressure, and pressure-sensitive-paint measurements. This paper focuses on data obtained on the pre-production configuration of the F/A-18E aircraft at Mach number of 0.90. The flow unsteadiness occurring on the wing as the wing went through the stall process was captured using the time history of balance and pressure measurements and by calculating the root mean square (RMS) for a number of instrument signals. The second step was to gather global perspectives on the pressures influencing the wing stall process. The abrupt wing stall experienced by the 8% F/A-18E Model was observed to be an unsteady event triggered by the rapid advancement of separation, which had migrated forward from the trailing edge, to the leading-edge flap hingeline over a very small increment in angle of attack. The angle of attack at which this stall occurred varied, from run to run, over an 1 deg increment. The abrupt wing stall was observed, using pressure-sensitive-paint, to occur simultaneously on both wing panels or asymmetrically. The pressure-sensitive paint data and wingroot bending moment data were essential in providing insight to the flow structures occurring over the wing and the possible asymmetry of those flow structures. A repeatability analysis conducted on eight runs of static data provided a quick and inexpensive examination of the unsteady aerodynamic characteristics of abrupt wing stall. The results of the repeatability analysis agreed extremely well with data obtained using unsteady measurement techniques. This approach could be used to identify test conditions for more complex unsteady data measurements using special instrumentation.

McMillin, S. Naomi↗

Transonic Experimental Observations of Abrupt Wing Stall on an F/A-l8E Model

A transonic wind tunnel test of an 8% F/A-18E model was conducted in the NASA Langley Research Center (LaRC) 16 ft Transonic Tunnel (16-ft TT) to investigate on-surface flow physics during stall. The technical approach employed focused on correlating static (or time-averaged) and unsteady wind-tunnel test data to the unsteady wing-stall events using force, moment, pressure, and pressure-sensitive-paint measurements. This paper focuses on data obtained on the pre-production configuration of the F/A-18E aircraft at Mach number of 0.90. The flow unsteadiness occurring on the wing as the wing went through the stall process was captured using the time history of balance and pressure measurements and by calculating the root mean square (RMS) for a number of instrument signals. The second step was to gather global perspectives on the pressures influencing the wing stall process. The abrupt wing stall experienced by the 8% F/A-18E Model was observed to be an unsteady event triggered by the rapid advancement of separation, which had migrated forward from the trailing edge, to the leading-edge flap hingeline over a very small increment in angle of attack. The angle of attack at which this stall occurred varied, from run to run, over an 1 degree increment. The abrupt wing stall was observed, using pressure-sensitive-paint, to occur simultaneously on both wing panels or asymmetrically. The pressure-sensitive paint data and wing-root bending moment data were essential in providing insight to the flow structures occurring over the wing and the possible asymmetry of those flow structures. A repeatability analysis conducted on eight runs of static data provided a quick and inexpensive examination of the unsteady aerodynamic characteristics of abrupt wing stall. The results of the repeatability analysis agreed extremely well with data obtained using unsteady measurement techniques. This approach could be used to identify test conditions for more complex unsteady data measurements using special instrumentation.

McMillin, S. Naomi↗

An Experimental and Numerical Study of a Supersonic Burner for CFD Model Development

A laboratory scale supersonic burner has been developed for validation of computational fluid dynamics models. Detailed numerical simulations were performed for the flow inside the combustor, and coupled with finite element thermal analysis to obtain more accurate outflow conditions. A database of nozzle exit profiles for a wide range of conditions of interest was generated to be used as boundary conditions for simulation of the external jet, or for validation of non-intrusive measurement techniques. A set of experiments was performed to validate the numerical results. In particular, temperature measurements obtained by using an infrared camera show that the computed heat transfer was larger than the measured value. Relaminarization in the convergent part of the nozzle was found to be responsible for this discrepancy, and further numerical simulations sustained this conclusion.

Magnotti, G.↗

High-precision Non-Contact Measurement of Creep of Ultra-High Temperature Materials for Aerospace

For high-temperature applications (greater than 2,000 C) such as solid rocket motors, hypersonic aircraft, nuclear electric/thermal propulsion for spacecraft, and more efficient jet engines, creep becomes one of the most important design factors to be considered. Conventional creep-testing methods, where the specimen and test apparatus are in contact with each other, are limited to temperatures approximately 1,700 C. Development of alloys for higher-temperature applications is limited by the availability of testing methods at temperatures above 2000 C. Development of alloys for applications requiring a long service life at temperatures as low as 1500 C, such as the next generation of jet turbine superalloys, is limited by the difficulty of accelerated testing at temperatures above 1700 C. For these reasons, a new, non-contact creep-measurement technique is needed for higher temperature applications. A new non-contact method for creep measurements of ultra-high-temperature metals and ceramics has been developed and validated. Using the electrostatic levitation (ESL) facility at NASA Marshall Space Flight Center, a spherical sample is rotated quickly enough to cause creep deformation due to centrifugal acceleration. Very accurate measurement of the deformed shape through digital image analysis allows the stress exponent n to be determined very precisely from a single test, rather than from numerous conventional tests. Validation tests on single-crystal niobium spheres showed excellent agreement with conventional tests at 1985 C; however the non-contact method provides much greater precision while using only about 40 milligrams of material. This method is being applied to materials including metals and ceramics for non-eroding throats in solid rockets and next-generation superalloys for turbine engines. Recent advances in the method and the current state of these new measurements will be presented.

Rogers, Jan R.↗

Analysis of International Space Station Materials on MISSE-3 and MISSE-4

For high-temperature applications (> 2,000 C) such as solid rocket motors, hypersonic aircraft, nuclear electric/thermal propulsion for spacecraft, and more efficient jet engines, creep becomes one of the most important design factors to be considered. Conventional creep-testing methods, where the specimen and test apparatus are in contact with each other, are limited to temperatures ~1,700 deg. C. Development of alloys for higher-temperature applications is limited by the availability of testing methods at temperatures above 2000 C. Development of alloys for applications requiring a long service life at temperatures as low as 1500 C, such as the next generation of jet turbine superalloys, is limited by the difficulty of accelerated testing at temperatures above 1700 0c. For these reasons, a new, non-contact creep-measurement technique is needed for higher temperature applications. A new non-contact method for creep measurements of ultra-high-temperature metals and ceramics has been developed and validated. Using the electrostatic levitation (ESL) facility at NASA Marshall Space Flight Center, a spherical sample is rotated quickly enough to cause creep deformation due to centrifugal acceleration. Very accurate measurement of the deformed shape through digital image analysis allows the stress exponent n to be determined very precisely from a single test, rather than from numerous conventional tests. Validation tests on single-crystal niobium spheres showed excellent agreement with conventional tests at 1985 C; however the non-contact method provides much greater precision while using only about 40 milligrams of material. This method is being applied to materials including metals and ceramics for noneroding throats in solid rockets and next-generation superalloys for turbine engines. Recent advances in the method and the current state of these new measurements will be presented.

Finckenor, Miria M.↗

Structures and Materials Research at NASA Langley Research Center

NASA explores the unknown in air and space, innovates for the benefit of humanity, and inspires the world through discovery. The Structures and Materials discipline at NASA Langley Research Center supports this mission through advanced materials and manufacturing approaches applied to innovative structural concepts. We start with synthesizing novel material systems and applying tools and methods to predict and validate their static, dynamic, durability and damage tolerance behavior. We mature materials from test tube to test flight by developing manufacturing techniques that enable the advancement of aerospace structures from concept to reality. We develop advanced measurement techniques for health management and nondestructive evaluation. We draw on our structures and materials core capabilities to enable safe, reliable lightweight aerospace structures for application in all environments. You will find the results of our work in the assembly of large structures in space and on other planets, vehicles that carry crew into space, vehicles that operate at high speeds and in extreme environments, and technology for passenger and crew safety in commercial aviation. This presentation will provide an overview of Langley Research Center’s role within the agency, then focus on how current Structures and Materials research areas support a variety of NASA missions in space operations, exploration, and aeronautics.

Structures↗

Access to Special Nuclear Material at the Idaho National Laboratory

Access to special nuclear material (SNM) such as enriched uranium or plutonium is critical to the experimental validation of measurement techniques for nuclear nonproliferation applications. It is especially important that realistic quantities be available for measurements in the field. Security and safety requirements have made such access nearly impossible at many U.S. facilities. The Idaho National Laboratory (INL) has been able to provide kilogram quantities of SNM for in situ measurements ranging from testing of equipment in laboratory facilities, to outdoor measurements simulating real conditions, to transfer of the SNM to the customer’s facility and back for measurements in the field. The INL will be working to make SNM more widely accessible for measurements by nuclear nonproliferation projects, including those with international researchers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Optical measurement systems

Some of the areas of research conducted at Lewis on optical measurement techniques are described. Two laser anemometer systems developed at Lewis are used to illustrate the special instrumentation needs encountered in aeropropulsion research. Velocity measurements to be made through small viewing ports, close to surfaces within the propulsion system components, and in turbulent or highly-accelerating flows are some of the significant challenges. The application to research facilities of two advanced optical systems, the rainbow schlieren and the combustor viewing system, is presented. The calibration and verification of commercial optical measuring systems, such as droplet sizing systems, are also discussed. Calibration techniques capable of simulating moving droplets for flight-type sizing systems are being developed at Lewis. The presentation concludes with a brief look at the forces driving future research on optical instrumentation.

Lesco, Daniel J.↗

On-the-Fly Mapping for Calibrating Directional Antennas

An improved method of calibrating a large directional radio antenna of the type used in deep-space communication and radio astronomy has been developed. This method involves a raster-scanning-and-measurement technique denoted on-the-fly (OTF) mapping, applied in consideration of the results of a systematic analysis of the entire measurement procedure. Phenomena to which particular attention was paid in the analysis include (1) the noise characteristics of a total-power radiometer (TPR) that is used in the measurements and (2) tropospherically induced radiometer fluctuations. The method also involves the use of recently developed techniques for acquisition and reduction of data. In comparison with prior methods used to calibrate such antennas, this method yields an order-of-magnitude improvement in the precision of determinations of antenna aperture efficiency, and improvement by a factor of five or more in the precision of determination of pointing error and beam width. Prerequisite to a meaningful description of the present method is some background information concerning three aspects of the problem of calibrating an antenna of the type in question: In OTF mapping measurements in which a TPR is used, the desired data are the peak temperature corresponding to a radio source, the pointing offset when the antenna is commanded to point toward the source, and the shape of the main lobe of the antenna beam, all as functions of the antenna beam elevation and azimuth angles. These data enable one to calculate the (1) antenna aperture efficiency by comparing the measured peak temperature with that expected for a 100-percent-efficient antenna, (2) the mechanical pointing error resulting from small misalignments of various parts of the antenna structure, and (3) misalignments of the antenna subreflector and other mirrors. For practical reasons having to do with obtaining adequate angular resolution and all-sky coverage, it is necessary to perform azimuth and elevation scans fairly rapidly. Many natural radio sources used in calibrating antennas are only approximately pointlike: some sources subtend angles greater than the beam width of a given antenna. In such a case, the antenna partially resolves the source structure and does not collect all of the radiation emitted by the source. This makes it necessary to estimate how much of the total known radiation from the source would actually be collected by the antenna if it were 100-percent efficient. The resulting estimate, leading to a source-size correction factor, introduces another degree of uncertainty to the measurements. OTF mapping can remove this uncertainty

Rochblatt, David↗

Alpha Coincidence Detection for the Assay of Actinides

Abstract – Interferences in both decay counting and mass counting techniques limit their application for some environmental monitoring applications. For example, 238U interferes with 238Pu in mass spectrometry measurements, while in conventional alpha spectroscopy measurements it is nearly impossible to separate 238Pu from 241Am and 239Pu from 240Pu. These interferences are typically resolved by using chemical separation and/or different measurement techniques for different isotopes. We are investigating radiation detector concepts to simultaneously assay these four isotopes with minimal sample preparation by exploiting radiation signatures measured in coincidence with the typical alpha decays of these isotopes. Particles in coincidence with the alpha decay include conversion electrons, gamma rays, x-rays, and Auger electrons. Each decay has a unique energy distribution enabling the separation of the isotopes. We are exploring two basic detector concepts to achieve these goals: a silicon-based design and a gas-detector design. The silicon system provides the potential for higher energy resolution at the cost of lower efficiency compared to a gas detector. In this paper, we will describe our evaluation of the different detector concepts, which will include detection efficiency, ability to resolve the isotopes, sample preparation and equipment requirements.

Warren, Glen A.↗

Multi-modal chemical characterization of highly viscous submicrometer organic particles

Distinguishing highly viscous organic particles within complex mixtures of atmospheric aerosol and accurate descriptions of their composition, size distributions, and mixing states are challenges at the forefront of aerosol measurement science and technology. Here, we present results obtained from complementary single-particle measurement techniques employed for the in-depth characterization of highly viscous particles. In this study, we demonstrate advantages and synergy of this multi-modal particle characterization approach based on the analysis of individual viscous particles formed in the air-discharged waste produced by a common sewer pipe rehabilitation technology. Using oil immersion flow microscopy, we investigate particle size distributions and morphology of colloidal components present in field-collected aqueous waste condensates. We compare these results with corresponding measurements of viscous particles formed in drying droplets of the aerosolized discharged waste. The colloidal components and viscous particles were found to be approximately 10 µm and 0.5 µm, respectively. The aerosolized viscous particles exhibited a spherical morphology, while the colloidal particles appeared noticeably fractal, resembling fragments of a cured composite material. Chemical imaging of the viscous particles collected on substrates was performed using scanning electron microscopy and soft X-ray spectro-microscopy techniques. Through these methods, comprehensive description of these particles emerged, confirming their high solid-like viscosity, wide-ranging sizes, diverse carbon speciation with high degrees of oxygenation, and high organic volume fractions. The aerosolized viscous particles were further characterized using high-throughput single particle mass spectrometry. This technique provides real-time measurements of composition, size, and morphological metrics for large numbers of individual particles, enabling the identification of their distinct mass spectrometric signatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compositional dependence of the nonlinear refractive index of new germanium-based chalcogenide glasses

In this paper, we report results of n{sub 2} measurements of new chalcogenide glasses in the Ge-Sb-S-Se system using a modified Z-Scan technique. Measurements were made with picosecond pulses emitted by a 10 Hz Q-switched mode-locked Nd-YAG laser at 1064 nm under conditions suitable to characterize ultrafast nonlinearities. The nonlinear index increases up to 500 times the n{sub 2} of fused silica with an increase in the Ge/Se ratio and a decrease with an increase of the Ge/Sb ratio. We confirmed, using Raman spectroscopy, that the nonlinear refractive index depends on the number of Ge-S(Se) and Sb-S(Se) bonds in the glass network. Sulfide glasses were shown to have a nonlinear FOM near or <1, at 1064 nm. - Graphical abstract: In this paper, we report results of n{sub 2} measurements of new chalcogenide glasses in the Ge-Sb-S-Se system using a modified Z-Scan technique. n{sub 2} is found to increase with an increase of normalized photon energy, regardless of chalcogen type, but does not depend on the concentration of lone pair electron.

36 MATERIALS SCIENCE↗

Temperature and heat flux measurements: Challenges for high temperature aerospace application

The measurement of high temperatures and the influence of heat transfer data is not strictly a problem of either the high temperatures involved or the level of the heating rates to be measured at those high temperatures. It is a problem of duration during which measurements are made and the nature of the materials in which the measurements are made. Thermal measurement techniques for each application must respect and work with the unique features of that application. Six challenges in the development of measurement technology are discussed: (1) to capture the character and localized peak values within highly nonuniform heating regions; (2) to manage large volumes of thermal instrumentation in order to efficiently derive critical information; (3) to accommodate thermal sensors into practical flight structures; (4) to broaden the capabilities of thermal survey techniques to replace discrete gages in flight and on the ground; (5) to provide supporting instrumentation conduits which connect the measurement points to the thermally controlled data acquisition system; and (6) to develop a class of 'vehicle tending' thermal sensors to assure the integrity of flight vehicles in an efficient manner.

Neumann, Richard D.↗

Review of non destructive assay techniques utilised for decommissioning of plutonium facilities at AWE - 14418

Over the past fifteen years AWE has decommissioned and size reduced a large number of glove boxes that contained a wide spectrum of equipment that ranged from highly radiation attenuating structures, such as furnaces and lathes, to other less radiation attenuating apparatus, such as small discrete tools or simple work benches. In order to generate meaningful glove box residual fissile material inventory data, which can constructively inform the selection of measures needed to underwrite the criticality safety of size reduction and consignment to waste activities, several different types of Non Destructive Assay (NDA) measurement techniques are available at AWE. These are deployed for the estimate of the residual fissile material inventory prior to decommissioning activities and for the final NDA of waste containers, post decommissioning. The techniques range from the Decommissioning In-Situ Plutonium Inventory Monitor (DISPIM), through other Neutron Coincidence Counting (NCC) techniques (Neutron Panel monitoring) and gamma measurements to consideration of Thermo Luminescent Detector (TLD) data. This paper will present a comparison of the fissile material identified in the waste generated post decommissioning operations to the NDA estimate of the residual fissile material inventory for the glove boxes, as well as provide a direct comparison between the different NDA techniques available at AWE. The findings to date indicate that the glove box residual fissile material inventory used for criticality safety purposes bounds the decommissioning process, subject to the suitable deployment of the NDA technique and the inclusion of appropriate uncertainties. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Concepts for Alpha Coincidence Detection

The effectiveness of conventional measurement techniques for environmental monitoring is limited by background and other interferences. We are exploring a new measurement approach involving the detection of α particles in coincidence with conversion electrons as a means to simultaneously assay environmental samples for actinides without chemical separation. The initial target isotopes studied in this work are 238Pu, 239Pu, 240Pu and 241Am. We explore various aspects of the design, such as impact of the mounting of the source material, resolution requirements and impact of a background on isotopic uncertainties. We conclude that a dual gas proportional counter and a dual-sided, large-area silicon detector could provide similar performance for the measurement scenario examined.

Warren, Glen A.↗

Contact Versus Non-Contact Measurement of a Helicopter Main Rotor Composite Blade

The dynamic characterization of lightweight structures is particularly complex as the impact of the weight of sensors and instrumentation (cables, mounting of exciters...) can distort the results. Varying mass loading or constraint effects between partial measurements may determine several errors on the final conclusions. Frequency shifts can lead to erroneous interpretations of the dynamics parameters. Typically these errors remain limited to a few percent. Inconsistent data sets however can result in major processing errors, with all related consequences towards applications based on the consistency assumption, such as global modal parameter identification, model-based damage detection and FRF-based matrix inversion in substructuring, load identification and transfer path analysis [1]. This paper addresses the subject of accuracy in the context of the measurement of the dynamic properties of a particular lightweight structure. It presents a comprehensive comparative study between the use of accelerometer, laser vibrometer (scanning LDV) and PU-probe (acoustic particle velocity and pressure) measurements to measure the structural responses, with as final aim the comparison of modal model quality assessment. The object of the investigation is a composite material blade from the main rotor of a helicopter. The presented results are part of an extensive test campaign performed with application of SIMO, MIMO, random and harmonic excitation, and the use of the mentioned contact and non-contact measurement techniques. The advantages and disadvantages of the applied instrumentation are discussed. Presented are real-life measurement problems related to the different set up conditions. Finally an analysis of estimated models is made in view of assessing the applicability of the various measurement approaches for successful fault detection based on modal parameters observation as well as in uncertain non-deterministic numerical model updating.

36 MATERIALS SCIENCE↗