Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Characterizations of strip-line microwave micro atmospheric plasma and its application to neutralization

In this work, we estimate the plasma parameters of strip-line microwave micro atmospheric plasma (SMMAP) such as rotational temperature (T{sub r}) both from OH and N{sub 2} rotational transitions (610-770 and 770-980 K in Ar, respectively), electron density (N{sub e}) from Stark broadening (about 10{sup 13}/cm{sup 3} in mixture of Ar and H{sub 2}), and the distribution of electric field before ignition of SMMAP (5x10{sup 4} V/m at maximum, and applied voltage less than 5 V). Since the lower applied voltage of SMMAP might enable us to conduct efficient processing without electrostatic damage (ESD), we applied jet-type SMMAP to neutralization. The result of neutralization showed that it can reduce surface charge from +-1000 to +-100 V for 0.2 s at 10 W with Ar gas flow within 4 V offset voltage, which provides efficient plasma processing without ESD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

INNOVATIVE EDDY CURRENT PROBE FOR MICRO DEFECTS

This paper reports the development of an innovative eddy current (EC) probe, and its application to micro-defects on the root of the Friction Stir Welding (FSW). The new EC probe presents innovative concept issues, allowing 3D induced current in the material, and a lift-off independence. Validation experiments were performed on aluminium alloys processed by FSW. The results clearly show that the new EC probe is able to detect and sizing surface defects about 60 microns depth.

36 MATERIALS SCIENCE↗

Dimensional Control of Micro Components with Synchrotron Computed Tomography

An advantage of Computed Tomography (CT) is the coordinate measurement capability of small inner structures, which are not accessible with classical measurement techniques. Using the advantages of synchrotron radiation CT measurements of parts with sizes of a few millimeters are performed at BAMline of BESSY II and are expected to be used as references for further dimensional measurements with micro CT. Previous investigations were focused on external gears, which are accessible with standard Coordinate Measurement Machines (CMMs). To obtain information about the accuracy of dimensional measurements of internal gears with CT, reference data have been measured by a tactile-optical CMM. This information is used to evaluate the performance of the CT. In addition to the first results for the evaluation of internal gear flanks, new measurements of different gear materials (steel and zirconium dioxide) will be presented. For functional evaluation, gear flanks are a matter of particular interest. Form deviations are analyzed with respect to the different gear materials to establish CT measurements as technology in the field of quality assurance and to compare the different manufacturing processes.

07 ISOTOPE AND RADIATION SOURCES↗

MICRO-SCALE CFD MODELING OF OSCILLATING FLOW IN A REGENERATOR

Regenerator models used by designers are macro-scale models that do not explicitly consider interactions between the fluid and the solid matrix. Rather, the heat transfer coefficient and pressure drop are calculated using correlations for Nusselt number and friction factor. These correlations are typically based on steady flow data. The error associated with using steady flow correlations to characterize the oscillatory flow that is actually present in the regenerator is not well understood. Oscillating flow correlations based on experimental data do exist in the literature; however, these results are often conflicting. This paper uses a micro-scale computational fluid dynamic (CFD) model of a unit-cell of a regenerator matrix to determine the conditions for which oscillating flow affects friction factor. These conditions are compared to those found in typical pulse tube regenerators to determine whether oscillatory flow is of practical importance. CFD results clearly show a transition Valensi number beyond which oscillating flow significantly increases the friction factor. This transition Valensi number increases with Reynolds number. Most practical pulse tube regenerators will operate below this Valensi transition number and therefore this study suggests that the effect of flow oscillation on pressure drop can be neglected in macro-scale regenerator models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and Numerical Investigation of Propellant of Different Thickness for Laser Micro Propulsion

The thickness of propellant is an important experimental parameter under T-mode, which has a direct impact on the performance of the laser Micro propulsion. In this paper, the prolusion performance of four propellants with different thickness is measured respectively, the experimental results show that the momentum coupling coefficient C{sub m} rises with the increase of thickness, while the specific impulse I{sub sp} falls on the contrary. The same trend for I{sub sp} also has been obtained from the simulated result by the Discrete Element Program (DEM).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Commissioning and Performance of the Soft X-ray Micro-characterization Beamline at the Canadian Light Source

The Soft X-ray Micro-characterization Beamline (SXRMB) is a medium energy, bending magnet based beamline, designed to cover an energy range of 1.7-10 keV using two sets of crystals--InSb(111) and Si(111). The design goal is to deliver a flux of 2x10{sup 11} photons sec{sup -1}/100 mA with a resolution up to 10,000 for X-ray Absorption Spectroscopy. A KB mirror stage is designed to provide microprobe capability, with a spot size of 10x10 {mu}m{sup 2} and a flux of >10{sup 9} at the microprobe station. The beamline has been in the commissioning phase since 2008, and access to the X-ray absorption endstation is now open to general users. The optical commissioning and performance of the beamline is presented with some early experimental results.

43 PARTICLE ACCELERATORS↗

Formation of Micro and Nano Structures Using VUV 157 nm Laser Radiation

We report on laser ablation experiments on micro and nano size composite structures. The surface of CR-39 and polycarbonate has been intentionally seeded with silicon carbide and silver nanowires and subsequently laser irradiated at a wavelength of 157 nm. We show scanning electron micrograph images of prismatic and conical structures produced by laser ablation and discuss a shape transformation from a prismatic to a conical structure.

36 MATERIALS SCIENCE↗

On the polarity of GaN micro- and nanowires epitaxially grown on sapphire (0001) and Si(111) substrates by metal organic vapor phase epitaxy and ammonia-molecular beam epitaxy

The polarity of GaN micro- and nanowires grown epitaxially by metal organic vapor phase epitaxy on sapphire substrates and by molecular-beam epitaxy, using ammonia as a nitrogen source, on sapphire and silicon substrates has been investigated. On Al{sub 2}O{sub 3}(0001), whatever the growth technique employed, the GaN wires show a mixture of Ga and N polarities. On Si(111), the wires grown by ammonia-molecular beam epitaxy are almost entirely Ga-polar (around 90%) and do not show inversion domains. These results can be understood in terms of the growth conditions employed during the nucleation stage.

36 MATERIALS SCIENCE↗

Impact of collisionality on fluctuation characteristics of micro-turbulence

The influence of changing collisionality on density fluctuation characteristics is studied during dedicated {nu}* scaling experiments, using Doppler backscattering system. First, the repartition of fluctuation energy over different spatial scales, as represented by the wavenumber spectrum, is investigated and a modification of the shape of the perpendicular wavenumber spectrum in the low wavenumber part of the spectrum is observed when changing collisionality. In addition, a new procedure to evaluate the dispersion relation of micro-turbulence is presented. From the behavior of the perpendicular mean velocity of density fluctuations with the perpendicular wavenumber, different dispersion relations are obtained between low and high collisionality cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Aspects of Ductile Mode Micro Laser Assisted Machining

This paper presents the simulation work performed to study an innovative process called micro-Laser Assisted Machining ({mu}-LAM). {mu}-LAM is being used for machining hard and brittle semiconductor and ceramic materials such as Silicon Carbide. Numerical simulations were carried out using the commercial software AdvantEdge Version 5.4. The cutting tool is modeled as a single point diamond tip. The workpiece material (4H-SiC) is heated locally during the actual machining process by a laser beam, which passes through the diamond tool tip. The workpiece is heated beyond the thermal softening point in order to study the effect of increased temperature on the machining process. The initial work started with an approximate thermal softening curve to ensure that thermal effects can be incorporated in the simulation model. A new thermal softening curve was developed based upon experimental data and implemented in the material model. A thermal boundary was provided on the workpiece top surface to simulate the effect of laser heating. In all three cases the chip formation was observed and the changes in cutting and thrust forces were evaluated. The simulation results indicate a significant decrease in machining forces if Silicon Carbide is heated and thermally softened thus demonstrating the benefits of the {mu}-LAM process.

36 MATERIALS SCIENCE↗

Micro-nano scale ripples on metallic glass induced by laser pulse

A Zr{sub 47.7}Cu{sub 31}Ni{sub 9}Al{sub 12.3} bulk metallic glass was irradiated directly by KrF excimer laser pulses with wavelength 248 nm and duration 10 ns. Scanning electronic microscope photographs indicated that many ripples in micro-nano scale would be generated on the edge of the irradiated area under the action of the higher intensity laser pulse. Detailed observation demonstrated that the ripples exhibited fluidity and became closer and closer out from interior. Theoretical analysis revealed the formation mechanism of the ripples, including melting, subsequent propagation of capillary waves and final solidification.

36 MATERIALS SCIENCE↗

Turn-key module for neutron scattering with sub-micro-eV resolution.

We report the development of a compact turn-key module that boosts the resolution in quasielastic neutron scattering by several orders of magnitude down to the low sub-micro-eV range. It is based on a pair of neutron resonance spin flippers that generate a well defined temporal intensity modulation, also known as Modulation of IntEnsity by Zero Effort (MIEZE). The module may be used under versatile conditions, in particular, in applied magnetic fields and for depolarizing and incoherently scattering samples. We demonstrate the power of MIEZE in studies of the helimagnetic order in MnSi under applied magnetic fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultraviolet photosensitivity of sulfur-doped micro- and nano-crystalline diamond

The room-temperature photosensitivity of sulfur-doped micro- (MCD), submicro- (SMCD) and nano- (NCD) crystalline diamond films synthesized by hot-filament chemical vapor deposition was studied. The structure and composition of these diamond materials were characterized by Raman spectroscopy, scanning electron microscopy and X-ray diffraction. The UV sensitivity and response time were studied for the three types of diamond materials using a steady state broad UV excitation source and two pulsed UV laser radiations. It was found that they have high sensitivity in the UV region, as high as 10 9 sec -1 mV -1 range, linear response in a broad spectral range below 320 nm, photocurrents around ~10 -5 A, and short response time better than 100 ns, which is independent of fluency intensity. A phenomenological model was applied to help understand the role of defects and dopant concentration on the materials’ photosensitivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Morphology of Nano and Micro Fiber Structures in Ultrafine Particles Filtration

Selected procedures permitting to prepare homogeneous nanofibre structures of the desired morphology by employing a suitable combination of variables during the electrospinning process are presented. A comparison (at the same pressure drop) was made of filtration capabilities of planar polyurethane nanostructures formed exclusively by nanofibres, space polycarbonate nanostructures having bead spacers, structures formed by a combination of polymethyl methacrylate micro- and nanofibres and polypropylene meltblown microstructures, through which ultrafine particles of ammonium sulphate 20-400 nm in size were filtered. The structures studied were described using a new digital image analysis technique based on black and white images obtained by scanning electron microscopy. More voluminous structures modified with distance microspheres and having a greater thickness and mass per square area of the material, i.e. structures possessing better mechanical properties, demanded so much in nanostructures, enable preparation of filters having approximately the same free volume fraction as flat nanofibre filters but an increased effective fibre surface area, changed pore size morphology and, consequently, a higher filter quality.

36 MATERIALS SCIENCE↗

A contribution to spectroscopic diagnostics and cathode sheath modeling of micro-hollow gas discharge in argon

In this paper, the hydrogen Balmer beta line shape from a micro-hollow gas discharge (MHGD) in argon with traces of hydrogen is used for simultaneous diagnostics of plasma and cathode sheath (CS) parameters. For this purpose, a simple model of relevant processes responsible for the line broadening is introduced and applied to the Balmer beta profile recorded from a MHGD generated in the microhole (diameter 100 {mu}m at narrow side and 130 {mu}m at wider side) of a gold-alumina-gold sandwich in the pressure range (100-900 mbar). The electron number density N{sub e} in the range (0.4-4.5) x 10{sup 20} m{sup -3} is determined from the width of the central part of the Balmer beta line profile, while, from the extended wings of the Balmer beta profile, induced by dc Stark effect, the next three parameters are determined: the average value E{sub a} of electric field strength in the CS in the range (16-95 kV/cm), the electric field strength E{sub 0} at the cathode surface in the range (32-190 kV/cm), and the CS thickness z{sub g} in the range (18-70 {mu}m). All four MHGD parameters, N{sub e}, E{sub a}, E{sub 0}, and z{sub g}, compare reasonably well with results of the modeling experiment by M. J. Kushner [J. Phys. D: Appl. Phys. 38, 1633 (2005)]. The results for N{sub e} are compared with other emission experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Resolution X-ray Microprobe Using a Spatial Filter and Its Application to Micro-XAFS Measurements

An x-ray microprobe system with total-reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring-8. To achieve sub-microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x-ray energy range of 6-14 keV. A focused beam size of 0.83 {mu}m(V)x1.35 {mu}m(H) has been obtained at an x-ray energy of 10 keV, and using a spatial filter in the horizontal direction, the beam size is down to 0.84 {mu}m. Micro-x-ray absorption fine structure (XAFS) spectroscopy of submicrometer particles has been done by utilizing the total-reflection mirror optics. It was clearly observed from the nickel K-edge XAFS spectra that the oxidation state of nickel was a mixture of metal and oxide even in the single submicrometer particle.

07 ISOTOPE AND RADIATION SOURCES↗

Development of an X-ray Micro-Laminography System at SPring-8

An x-ray micro-laminography system has been developed at SPring-8 and applied to measurements of planar objects that cannot be observed by x-ray computed tomography. To reconstruct a sectional image parallel to the planar surface, a filtered back-projection technique considering the inclination angle of a rotational axis was developed. Experimental conditions suitable for laminography measurements in this system were investigated. Spatial resolution in the reconstructed plane was almost determined by the detector resolution, while the spatial resolution perpendicular to the planar surface tended to be worse by the artifacts inherent of the laminographic scanning and reconstruction method. A laminated test sample was clearly observed in three dimensions.

07 ISOTOPE AND RADIATION SOURCES↗

Micro-Photoluminescence Characterization of Low Density Droplet GaAs Quantum Dots for Single Photon Sources

The GaAs quantum dots in AlGaAs barriers were grown by droplet epitaxy, emitting around 700 nm in wavelength which is compatible with low cost Si based detectors. The excitation power dependent and time resolved micro-photoluminescence measurements identified optical characteristics of exciton and biexciton states which are attributed to good quantum confinements in GaAs QDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗