Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Characterizing automotive fuel cell materials by soft x-ray scanning transmission x-ray microscopy

Proton-Exchange Membrane Fuel Cell (PEM-FC) based engines are being developed rapidly for near-term implementation in hydrogen fueled, mass production, personal automobiles. Research is focused on understanding and controlling various degradation processes (carbon corrosion, Pt migration, cold start), and reducing cost by reducing or eliminating Pt catalyst. We are using soft X-ray scanning transmission X-ray microscopy (STXM) at the S 2p, C 1s, O 1s and F 1s edges to study a variety of issues related to optimization of PEM-FC materials for automotive applications. A method to efficiently and accurately measure perfluorosulfonic acid distributions was developed and is being used to better understand how different loadings and preparation methods affect the ionomer distribution in the cathode. Progress towards an environmental cell capable of controlling the temperature and humidity of a PEM-FC sample in the STXM is described. Methods for studying the 3D chemical structure of PEM-FC are outlined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent progress of hard x-ray imaging microscopy and microtomography at BL37XU of SPring-8

A hard x-ray imaging microscopy and microtomography system is now being developed at the beamline 37XU of SPring-8. In the latest improvement, a spatial resolution of about 50 nm is achieved in two-dimensional imaging at 6 keV x-ray energy using a Fresnel zone plate objective with an outermost zone width of 35 nm. In the tomographic measurement, a spatial resolution of about 100 nm is achieved at 8 keV using an x-ray guide tube condenser optic and a Fresnel zone plate objective with an outermost zone width of 50 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential phase contrast in scanning x-ray microscopy with half-wavelength phase shifter

A method for differential-phase-contrast imaging in scanning x-ray microscopy is proposed. The microfocus beam is produced with an x-ray focusing optics, and a half of the optical aperture is masked with a λ/2 phase shifter. This generates a pair of focused beam at the focal plane, with π phase difference. Combining with a diaphragm in front of the transmission beam detector, differential phase contrast (contrast proportional to the phase-difference between two foci) can be obtained. Preliminary results with a Fresnel zone plate focusing optics at 12.4 keV x-ray energy are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory source based full-field x-ray microscopy at 9 keV

In the past decade, hard x-ray transmission microscopy experienced tremendous developments. With the avail-ability of efficient Fresnel zone plates, even set-ups utilizing laboratory sources were developed [1]. In order to improve the performance of these x-ray microscopes, novel approaches to fabricate optical elements [2] and brighter x-ray tubes [3] are promising candidates. We are currently building a laboratory transmission x-ray microscope for 9.25 keV, using an electron impact liquid-metal-jet anode source. Up to now, the further elements of our setup are: a polycapillary condenser, a tungsten zone plate, and a scintillator which is optically coupled to a CMOS camera. However, further variations in terms of optical elements are intended. Here we present the current status of our work, as well as first experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic x-ray microscopy at low temperatures – Visualization of flux distributions in superconductors

X-ray Magnetic Circular Dichroism (XMCD) microscopy at liquid nitrogen temperature has been performed on bilayers of high-T{sub c} superconducting YBCO (YBa{sub 2}Cu{sub 3}O{sub 7-δ}) and soft-magnetic Co{sub 40}Fe{sub 40}B{sub 20}. This should allow us to map the magnetic flux density distribution in the current-carrying state of the superconductor with high spatial resolution. For that purpose the UHV scanning X-ray microscope MAXYMUS has been upgraded by a MMR Micro Miniature Joule-Thompson cryostat capable of temperatures between 75 K and 580 K. Resulting XMCD images of the magnetic flux density in the superconductor with a field of view ranging from millimeters to micrometers are presented. The microscope’s unique combination of total electron yield (TEY) measurements together with low temperatures offers novel possibilities concerning the current transport in superconductors on small length scales.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Repeatability and reproducibility of intracellular molar concentration assessed by synchrotron-based x-ray fluorescence microscopy

Elemental analysis of biological sample can give information about content and distribution of elements essential for human life or trace elements whose absence is the cause of abnormal biological function or development. However, biological systems contain an ensemble of cells with heterogeneous chemistry and elemental content; therefore, accurate characterization of samples with high cellular heterogeneity may only be achieved by analyzing single cells. Powerful methods in molecular biology are abundant, among them X-Ray microscopy based on synchrotron light source has gaining increasing attention thanks to its extremely sensitivity. However, reproducibility and repeatability of these measurements is one of the major obstacles in achieving a statistical significance in single cells population analysis. In this study, we compared the elemental content of human colon adenocarcinoma cells obtained by three distinct accesses to synchrotron radiation light.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Transmission x-ray microscopy at Diamond-Manchester I13 Imaging Branchline

Full-field Transmission X-ray Microscopy (TXM) has been shown to be a powerful method for obtaining quantitative internal structural and chemical information from materials at the nanoscale. The installation of a Full-field TXM station will extend the current microtomographic capabilities of the Diamond-Manchester I13 Imaging Branchline at Diamond Light Source (UK) into the sub-100 nm spatial resolution range using photon energies from 8 to 14 keV. The dedicated Full-field TXM station will be built in-house with contributions of Diamond Light Source support divisions and via collaboration with the X-ray Optics Group of Paul Scherrer Institut (Switzerland) which will develop state-of-the-art diffractive X-ray optical elements. Preliminary results of the I13 Full-field TXM station are shown. The Full-field TXM will become an important Diamond Light Source direct imaging asset for material science, energy science and biology at the nanoscale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of contrast enhancement prior to iteration procedure on image correction for soft x-ray projection microscopy

Soft X-ray microscopy is well recognized as a powerful tool of high-resolution imaging for hydrated biological specimens. Projection type of it has characteristics of easy zooming function, simple optical layout and so on. However the image is blurred by the diffraction of X-rays, leading the spatial resolution to be worse. In this study, the blurred images have been corrected by an iteration procedure, i.e., Fresnel and inverse Fresnel transformations repeated. This method was confirmed by earlier studies to be effective. Nevertheless it was not enough to some images showing too low contrast, especially at high magnification. In the present study, we tried a contrast enhancement method to make the diffraction fringes clearer prior to the iteration procedure. The method was effective to improve the images which were not successful by iteration procedure only.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Examination of humidity effects on measured thickness and interfacial phenomena of exfoliated graphene on silicon dioxide via amplitude modulation atomic force microscopy

The properties of Few-Layer Graphene (FLG) change with the number of layers and Amplitude Modulation (AM) Atomic Force Microscopy (AFM) is commonly used to determine the thickness of FLG. However, AFM measurements have been shown to be sensitive to environmental conditions such as relative humidity (RH). In the present study, AM-AFM is used to measure the thickness and loss tangent of exfoliated graphene on silicon dioxide (SiO{sub 2}) as RH is increased from 10% to 80%. We show that the measured thickness of graphene is dependent on RH. The loss tangent values of the graphene and oxide regions are both affected by humidity, with generally higher loss tangent for graphene than SiO{sub 2}. As RH increases, we observe the loss tangent of both materials approaches the same value. We hypothesize that there is a layer of water trapped between the graphene and SiO{sub 2} substrate to explain this observation. Using this interpretation, the loss tangent images also indicate movement and change in this trapped water layer as RH increases, which impacts the measured thickness of graphene using AM-AFM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct electrocaloric measurement of 0.9Pb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}-0.1PbTiO{sub 3} films using scanning thermal microscopy

We show that scanning thermal microscopy can measure reversible electrocaloric (EC) effects in <40 μm-thick ceramic films of the relaxor ferroelectric 0.9Pb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}-0.1PbTiO{sub 3}, with the substrate present. We recorded roughly the same non-adiabatic temperature change (±0.23 K) for a thinner film that was driven harder than a thicker film (±31 V μm{sup −1} across 13 μm versus ±11 V μm{sup −1} across 38 μm), because the thicker film lay relatively closer to the substantially larger adiabatic values that we predicted by thermodynamic analysis of electrical data. Film preparation was compatible with the fabrication of EC multilayer capacitors, and therefore our measurement method may be exploited for rapid characterisation of candidate films for cooling applications.

36 MATERIALS SCIENCE↗

In situ transmission electron microscopy observation of ZnO polar and non-polar surfaces structure evolution under electron beam irradiation

In this paper, using in situ transmission electron microscopy, we investigated the dynamic reconstruction and evolution of ZnO polar and non-polar surfaces under high-energy electron beam irradiation. Electron beam radiolysis creates oxygen vacancies and a Zn rich (0001) surface. Positive polar charges at the (0001) surface expel loosely bonded Zn ions to diffuse away from the (0001) polar surface. As a result, mass loss was observed around the (0001) surface. Dehydration by the electron beam breaks the charge balance on the ( 000 1 ¯ ) polar surface. The negative charges on the ( 000 1 ¯ ) surface suppress the radiolysis effect and further absorb Zn ions to the surface to neutral the polar charges. The ideal stacking sequences of Zn ions in hexagonal ZnO structure can be considered as ABAB… along its c axis, while the absorbed individual Zn ion on the ( 000 1 ¯ ) surface occupies the C site to form three bonds with surface O ions beneath, instead of one bond in the ideal structure. With more Zn ion absorption and surface oxidization, new nanocrystals grow up from the ( 000 1 ¯ ) polar surface. Finally, new nanocrystals nucleated at the ( 01 1 ¯ 0 ) non-polar surface are driven by the electric field of the polar charges as well, for the Zn ions were always observed to absorb on the negatively charged [ 000 1 ¯ ] end of the newly formed ( 01 1 ¯ 0 ) surface layer.

74 ATOMIC AND MOLECULAR PHYSICS↗

Resolution enhancement in transmission electron microscopy with 60-kV monochromated electron source

Transmission electron microscopy (TEM) at low accelerating voltages is useful to obtain images with low irradiation damage. For a low accelerating voltage, linear information transfer, which determines the resolution for observation of single-layered materials, is largely limited by defocus spread, which improves when a narrow energy spread is used in the electron source. In this study, we have evaluated the resolution of images obtained at 60 kV by TEM performed with a monochromated electron source. The defocus spread has been evaluated by comparing diffractogram tableaux from TEM images obtained under nonmonochromated and monochromated illumination. The information limits for different energy spreads were precisely measured by using diffractograms with a large beam tilt. The result shows that the information limit reaches 0.1 nm with an energy width of 0.10 eV. With this monochromated source and a higher-order aberration corrector, we have obtained images of single carbon atoms in a graphene sheet by TEM at 60 kV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of absorption spectrum of deuterium oxide (D{sub 2}O) and its application to signal enhancement in multiphoton microscopy at the 1700-nm window

1700-nm window has been demonstrated to be a promising excitation window for deep-tissue multiphoton microscopy (MPM). Long working-distance water immersion objective lenses are typically used for deep-tissue imaging. However, absorption due to immersion water at 1700 nm is still high and leads to dramatic decrease in signals. In this paper, we demonstrate measurement of absorption spectrum of deuterium oxide (D{sub 2}O) from 1200 nm to 2600 nm, covering the three low water-absorption windows potentially applicable for deep-tissue imaging (1300 nm, 1700 nm, and 2200 nm). We apply this measured result to signal enhancement in MPM at the 1700-nm window. Compared with water immersion, D{sub 2}O immersion enhances signal levels in second-harmonic generation imaging, 3-photon fluorescence imaging, and third-harmonic generation imaging by 8.1, 24.8, and 24.7 times with 1662-nm excitation, in good agreement with theoretical calculation based on our absorption measurement. This suggests D{sub 2}O a promising immersion medium for deep-tissue imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-situ transmission electron microscopy growth of nanoparticles under extreme conditions

The formation and time resolved behavior of individual Pb nanoparticles embedded in silica have been studied by in-situ transmission electron microscopy observations at high temperatures (400–1100 °C) and under 200 keV electron irradiation. It is shown that under such extreme conditions, nanoparticles can migrate at long distances presenting a Brownian-like behavior and eventually coalesce. The particle migration phenomenon is discussed considering the influence of the thermal energy and the electron irradiation effects on the atomic diffusion process which is shown to control particle migration. These results and comparison with ex-situ experiments tackle the stability and the microstructure evolution of nanoparticles systems under extreme conditions. It elucidates on the effects of energetic particle irradiation-annealing treatments either as a tool or as a detrimental issue that could hamper their long-term applications in radiation-harsh environments such as in space or nuclear sectors.

36 MATERIALS SCIENCE↗

Passive microrheology of soft materials with atomic force microscopy: A wavelet-based spectral analysis

Compared to active microrheology where a known force or modulation is periodically imposed to a soft material, passive microrheology relies on the spectral analysis of the spontaneous motion of tracers inherent or external to the material. Passive microrheology studies of soft or living materials with atomic force microscopy (AFM) cantilever tips are rather rare because, in the spectral densities, the rheological response of the materials is hardly distinguishable from other sources of random or periodic perturbations. To circumvent this difficulty, we propose here a wavelet-based decomposition of AFM cantilever tip fluctuations and we show that when applying this multi-scale method to soft polymer layers and to living myoblasts, the structural damping exponents of these soft materials can be retrieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-microscopy study of the influence of stacking faults and three-dimensional In distribution on the optical properties of m-plane InGaN quantum wells grown on microwire sidewalls

The optical properties of m-plane InGaN/GaN quantum wells grown on microwire sidewalls were investigated carrying out a correlative scanning transmission electron microscopy (STEM), atom probe tomography (APT), and micro-photoluminescence study applied on single nanoscale field-emission tips obtained by a focused ion beam annular milling. Instead of assuming simple rectangular composition profiles, yielding misleading predictions for the optical transition energies, we can thus take into account actual compositional distributions and the presence of stacking faults (SFs). SFs were shown to be responsible for a lowering of the recombination energies of the order of 0.1 eV with respect to those expected for defect-free quantum wells (QWs). Such energy reduction allows establishing a good correspondence between the transition energies observed by optical spectroscopy and those calculated on the basis of the QWs In measured composition and distribution assessed by STEM structural analysis and APT chemical mapping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Work function of few layer graphene covered nickel thin films measured with Kelvin probe force microscopy

Few layer graphene and graphite are simultaneously grown on a ∼100 nm thick polycrystalline nickel film. The work function of few layer graphene/Ni is found to be 4.15 eV with a variation of 50 meV by local measurements with Kelvin probe force microscopy. This value is lower than the work function of free standing graphene due to peculiar electronic structure resulting from metal 3d-carbon 2p(π) hybridization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clean localization super-resolution microscopy for 3D biological imaging

We propose clean localization microscopy (a variant of fPALM) using a molecule filtering technique. Localization imaging involves acquiring a large number of images containing single molecule signatures followed by one-to-one mapping to render a super-resolution image. In principle, this process can be repeated for other z-planes to construct a 3D image. But, single molecules observed from off-focal planes result in false representation of their presence in the focal plane, resulting in incorrect quantification and analysis. We overcome this with a single molecule filtering technique that imposes constraints on the diffraction limited spot size of single molecules in the image plane. Calibration with sub-diffraction size beads puts a natural cutoff on the actual diffraction-limited size of single molecules in the focal plane. This helps in distinguishing beads present in the focal plane from those in the off-focal planes thereby providing an estimate of the single molecules in the focal plane. We study the distribution of actin (labeled with a photoactivatable CAGE 552 dye) in NIH 3T3 mouse fibroblast cells.

60 APPLIED LIFE SCIENCES↗