Evaluation of B and W UO{sub 2}/ThO{sub 2} VIII Experimental Core: Criticality and Thermal Disadvantage Factor Analysis

In the framework of the OECD/NEA International Reactor Physics Experiment (IRPHE) Project, an evaluation of core VIII of the Babcock and Wilcox (B and W) Spectral Shift Control Reactor (SSCR), critical experiment program was performed. The SSCR concept, moderated and cooled by a variable mixture of heavy and light water, envisaged changing of the thermal neutron spectrum during the operation to encourage breeding and to sustain the core criticality. Core VIII contained 2188 fuel rods with 93% enriched UO{sub 2}-ThO{sub 2} fuel in a moderator mixture of heavy and light water. The criticality experiment and measurements of the thermal disadvantage factor were evaluated. Benchmark criticality results using different cross-section libraries are reported. ENDF/B-VI.6 calculation was run using the S(α, β) model based on ENDF/B-VI.3 data while ENDF/B-VII.0 and ENDF/BVII.1 used an S(α, β) model based on ENDF/B-VII.0 data. JEFF calculations were run using the S(α, β) model based on JEFF 3.1.1 data except for the aluminum isotope, for which the S(α, β) model was missing. The maximum absolute deviation from the benchmark model was obtained using the JEFF-3.1.1 cross sections while closer results were obtained using ENDF/ B-VII.0 and ENDF/B-VII.1. Only ENDF/B-VII.1 and ENDF/B-VII.0 results are inside the 3σ uncertainty band (+2.8σ and 2.4σ, respectively), having deviations on the order of 300 pcm. The maximum deviation is -827 pcm (-6.1σ), using JEFF.3.1.1. Sample calculations of the TDF benchmark were also performed, studying the effects of the main nuclear data libraries. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of the Neutron Data Standards

With the need for improving existing nuclear data evaluations, (e.g., ENDF/B-VIII.0 and JEFF-3.3 releases) the first step was to evaluate the standards for use in such a library. This new standards evaluation made use of improved experimental data and some developments in the methodology of analysis and evaluation. In addition to the work on the traditional standards, this work produced the extension of some energy ranges and includes new reactions that are called reference cross sections. Since the effort extends beyond the traditional standards, it is called the neutron data standards evaluation. This international effort has produced new evaluations of the following cross section standards: the H(n,n), 6 Li(n,t), 10 B(n,α), 10 B(n,α 1 γ), nat C(n,n), Au(n,γ), 235 U(n,f) and 238 U(n,f). Also in the evaluation process the 238 U(n,γ) and 239 Pu(n,f) cross sections that are not standards were evaluated. Evaluations were also obtained for data that are not traditional standards: the Maxwellian spectrum averaged cross section for the Au(n,γ) cross section at 30 keV; reference cross sections for prompt γ-ray production in fast neutron-induced reactions; reference cross sections for very high energy fission cross sections; the 252 Cf spontaneous fission neutron spectrum and the 235 U prompt fission neutron spectrum induced by thermal incident neutrons; and the thermal neutron constants. The data and covariance matrices of the uncertainties were obtained directly from the evaluation procedure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NDMAS Overview

Overview of the Nuclear Data Management and Analysis System detailed as: Overview of NDMAS System, NDMAS NQA-1 process, Data in NDMAS, and Future work and new additions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NJOY2012 - Current Status and Future Plans

An overview of the NJOY Nuclear Data Processing Code System, including recent history, current status and near-term upgrade plans is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross sections of the {sup 67}Zn(n,{alpha}){sup 64}Ni reaction at 4.0, 5.0, and 6.0 MeV

Experimental cross section data of the {sup 67}Zn(n,{alpha}){sup 64}Ni reaction are very scanty because the residual nucleus {sup 64}Ni is stable and the commonly used activation method is not feasible. As a result, very large deviations (about 10 times) exist among different nuclear data libraries. In the present work, cross sections of the partial {sup 67}Zn(n,{alpha}{sub 0}){sup 64}Ni and total {sup 67}Zn(n,{alpha}){sup 64}Ni reactions are measured at neutron energies of 4.0 and 5.0 MeV for the first time, and those of 6.0 MeV are remeasured for consistency checking. A twin-gridded ionization chamber was used as the charged-particle detector and two enriched back-to-back-set {sup 67}Zn samples were adopted. Experiments were performed at the 4.5 MV Van de Graaff Accelerator of Peking University. Neutrons were produced through the {sup 2}H(d,n){sup 3}He reaction using a deuterium gas target. Absolute neutron flux was determined by counting the fission fragments from a {sup 238}U sample placed inside the gridded ionization chamber while a BF{sub 3} long counter was employed as neutron flux monitor. Present data are compared with results of previous measurements, evaluations, and talys code calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Investigation of the Performance of the Unified Monte Carlo Method of Neutron Cross Section Data Evaluation

The Unified Monte Carlo method (UMC) has been suggested to avoid certain limitations and approximations inherent to the well-known Generalized Least Squares (GLS) method of nuclear data evaluation. This contribution reports on an investigation of the performance of the UMC method in comparison with the GLS method. This is accomplished by applying both methods to simple examples with few input values that were selected to explore various features of the evaluation process that impact upon the quality of an evaluation. Among the issues explored are: i) convergence of UMC results with the number of Monte Carlo histories and the ranges of sampled values; ii) a comparison of Monte Carlo sampling using the Metropolis scheme and a brute force approach; iii) the effects of large data discrepancies; iv) the effects of large data uncertainties; v) the effects of strong or weak model or experimental data correlations; and vi) the impact of ratio data and integral data. Comparisons are also made of the evaluated results for these examples when the input values are first transformed to comparable logarithmic values prior to performing the evaluation. Some general conclusions that are applicable to more realistic evaluation exercises are offered.

99 GENERAL AND MISCELLANEOUS↗

Including Chi-Nu 235 U PFNS Experimental Data into an ENDF/B-VIII.1 Release Candidate Evaluation

This report documents an evaluation of 235 U prompt fission neutron spectra (PFNS) that is a release candidate for the upcoming U.S. nuclear data library, ENDF/B-VIII.1. This evaluation differs from its predecessor, ENDF/B-VIII.0, mainly by the inclusion of 235 U PFNS measured by the Chi-Nu team of LANL and LLNL. This data set is the first one that covers the 235 U PFNS for continuous incident-neutron energies of 1⁻20 MeV and outgoing-neutron energies from 10 keV⁻10 MeV with high precision. Previous data sets were either measured in a limited energy range or with less precision. Hence, these new Chi-Nu data provide decisive information for the evaluation. The resulting evaluated data correspond well to the new experimental PFNS. The evaluated PFNS also produce average mean energies and 239 Pu/ 235 U PFNS in agreement with associated Chi-Nu data. If one uses the new evaluated data to predict the neutron multiplication factor, k eff , of selected ICSBEP critical assemblies, the differences of simulated values compared to those using ENDF/B-VIII.0 is modest (less than 55 pcm). This difference in k eff can be easily accommodated by changes in the 235 U average prompt fission neutron multiplicity that is currently being re-evaluated. In addition to that, the new PFNS predict on average 235 U LLNL pulsed-sphere neutron-leakage spectra better than ENDF/B-VIIII.0 PFNS.

235U↗

Improvements in Electron-Photon-Relaxation Data for MCNP6

The Los Alamos Monte Carlo transport code MCNP6 has recently benefitted from significant work to improve the photon-electron transport and atomic-relaxation capabilities of the code. The improvements include extension of existing photon data to lower energies than previously supported; addition of new data such as subshell-specific photoelectric cross sections; completion of the incoherent and coherent form factor data to cover all scattering angles at all supported energies; new data for electron interactions including Bremsstrahlung, elastic scattering, subshell-specific electroionization, and atomic excitation; a much more detailed representation for atomic relaxation; and an entirely new (to MCNP) approach to electron transport: the single-event method. These improvements were made available with the initial production release of MCNP6 along with an extended electron, photon, and relaxation data file eprdata12 to support the new capabilities. More recently new data have become available and have now been incorporated into MCNP6, correcting a few issues with the previous work, and adding new sets of cross sections that were not included in eprdata12. The purpose of this paper is to introduce these newer changes and enhancements, which will be included with the next public release of the MCNP6 code system. The database that supports these developments relies on an evolving set of libraries originally released by D. E. Cullen and collaborators as separate data for photo-atomic interactions (EPDL), atomic relaxation (EADL), and electro-atomic interactions (EEDL). An updated version of this release was officially adopted in the ENDF/B VI.8 release of the Evaluated Nuclear Data File and it was this source that was used to produce the ACE (A Compact ENDF) format library eprdata12 for use in the initial production release of MCNP6.1 (and the subsequent interim release MCNP6.1.1). The latest improved version of this database was released by Cullen in 2014. This is the EPICS2014 collection, which includes both an ENDF-formatted file and separate EPDL, EADL, and EEDL files. In the area of photon-electron transport and atomic-relaxation, the newest enhancements to the current version of MCNP6 (scheduled for release as MCNP6.2) are primarily based on improvements and additions drawn from the EPICS2014 data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross-section measurement and analysis for the {sup 149}Sm(n,alpha){sup 146}Nd reaction at 6.0 MeV

We have measured the {sup 149}Sm(n,alpha){sup 146}Nd cross section at 6.0 MeV to be 0.12+-0.018 mb. This is the first reported result for this cross section in the MeV region and so should be helpful for constraining nuclear data evaluations (which differ by a factor of 40 for this reaction at this energy) and for testing and improving nuclear models. The experiment was performed at the at the 4.5-MV Van de Graaff accelerator of Peking University. Neutrons were produced via the {sup 2}H(d,n){sup 3}He reaction using a deuterium gas target, and absolute neutron flux was determined with a small {sup 238}U fission chamber. Alpha particles were detected using a two-section gridded ionization chamber in which two large-area {sup 149}Sm{sub 2}O{sub 3} samples were placed back-to-back so that the cross section and forward/backward ratio were measured for nearly the entire 4pi solid angle. The data were compared to statistical-model predictions using the code talys. Good agreement between the measured and theoretical cross sections could be obtained with a small modification of the alpha-optical potential parameters from their default values in talys. However, we were not able to reproduce the measured forward/backward ratio. In addition, using the previously reported {sup 147}Sm(n,alpha){sup 144}Nd cross section at 6.0 MeV together with our new result, good agreement was found between the measured and predicted cross-section ratio for these two isotopes. Finally, none of the existing evaluated data libraries are in agreement with our new data to within the experimental uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Processing Neutron Cross Section Covariances using NJOY-99 and PUFF-IV

With the growing demand for multigroup covariances, the National Nuclear Data Center (NNDC) has been experiencing an upsurge in its covariance data processing activities using the two US codes NJOY-99 (LANL) and PUFF-IV (ORNL). The code NJOY-99 was upgraded by incorporating the new module ERRORJ-2.3, while the NNDC served as the active user and provided feedback. The NNDC has been primarily processing neutron cross section covariances on its 64-bit Linux cluster in support of two DOE programs, the Global Nuclear Energy Partnership (GNEP) and the Nuclear Criticality Safety Program (NCSP). For GNEP, the NNDC used NJOY-99.259 to generate multigroup covariance matrices of {sup 56}Fe, {sup 23}Na, {sup 239}Pu, {sup 235}U and {sup 238}U from the JENDL-3.3 library using the 15-, 33-, and 230-energy group structures. These covariance matrices will be used to test a new collapsing algorithm which will subsequently be employed to calculate uncertainties on integral parameters in different fast neutron-based systems. For NCSP, we used PUFF-IV 1.0.4 to verify the processability of new evaluated covariance data of {sup 55}Mn, {sup 239}Pu, {sup 233}U, {sup 235}U and {sup 238}U generated by a collaboration of ORNL and LANL. For the data end-users at large, the NNDC has made available a Web site which provides a static visualization interface for all materials with covariance data in the four major data libraries: ENDF/B-VI.8 (47 materials), ENDF/B-VII.0 (26 materials), JEFF-3.1 (37 materials) and JENDL-3.3 (20 materials)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated User's Guide for Sammy: Multilevel R-Matrix Fits to Neutron Data Using Bayes' Equations

In 1980 the multilevel multichannel R-matrix code SAMMY was released for use in analysis of neutron-induced cross section data at the Oak Ridge Electron Linear Accelerator. Since that time, SAMMY has evolved to the point where it is now in use around the world for analysis of many different types of data. SAMMY is not limited to incident neutrons but can also be used for incident protons, alpha particles, or other charged particles; likewise, Coulomb exit hannels can be included. Corrections for a wide variety of experimental conditions are available in the code: Doppler and resolution broadening, multiple-scattering corrections for capture or reaction yields, normalizations and backgrounds, to name but a few. The fitting procedure is Bayes' method, and data and parameter covariance matrices are properly treated within the code. Pre- and post-processing capabilities are also available, including (but not limited to) connections with the Evaluated Nuclear Data Files. Though originally designed for use in the resolved resonance region, SAMMY also includes a treatment for data analysis in the unresolved resonance region.

43 PARTICLE ACCELERATORS↗

Design and producing of fine-group cross section library HENDL3.0/FG for subcritical system

To improve the accuracy of the neutron analyses for subcritical system with thermal fission blanket, a coupled neutron and photon (315 n + 42{gamma}) fine-group cross section library HENDL3.0/FG based on ENDF/B-VII, JEFF3.1 and JENDL3.3 was produced by FDS team. In order to test the availability and reliability of the HENDL3.0/FG data library, shielding and critical safety benchmarks were performed with VisualBUS code. The testing results indicated that the discrepancy between calculation and experimental values of nuclear parameters fell in a reasonable range. It showed that the nuclear data library had accuracy and availability. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Report - Improving Data for Short Lived Actinides

This document constitutes the final report for the “Improving Nuclear Data for Short Lived Actinides” research project. During this project 29 papers were published (or are about to be) in peer reviewed journals and conference proceedings which document the research and results extensively. The publications are listed below. Numerous invited and contributed talks were given at national and international nuclear physics meetings. The data collected during this project has in large part made it into the relevant databases for use by the customers. Numerous undergraduate, graduate and post-doctoral researchers were trained in the area of nuclear physics from over 12 different institutions and multiple countries during this research effort. That is reflected in the names and affiliations of the co-authors in the journal articles listed below.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Criticality control of a high-performance soluble-boron-free small modular reactor core

The pursuit for a soluble-boron-free (SBF) PWR core has been on-going for more than three decades. It is known that feasibility of such a design is generally higher as the core power (hence core size) is reduced. It is upon this observation that a new approach for an SBF small modular reactor (SMR) core was recently proposed. This paper aims to present criticality control management of the said investigation. All calculations in this study were completed using the 2-step Serpent /Coredax reactor analysis with ENDF/B-7.1 nuclear data library. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analog neutron transport for nuclear instrumentation applications with the Monte-Carlo code TRIPOLI-4 - Paper 3

Monte-Carlo codes simulating particle transport usually make use of well-known variance reduction techniques, leading to more efficient simulations. Even in configurations which do not deal with deep-penetration, some of these techniques, such as the implicit capture, are actually often used by default. The statistical weight of the simulated particles is then modified in order to take into account the modification of the sampling without introducing any bias in the estimation process. For instance, the implicit capture decreases the statistical weight of the particles at each collision, whereas the sampling of a single outgoing particle increases this statistical weight in case of scattering reactions producing multiple neutrons. In addition, Russian roulette and splitting operations, which are usually also played at each collision, lead to other modifications of the statistical weights. As a result, Monte-Carlo codes provide particle histories that are valid on average, but collect statistical weights which differ from 1, when tallying the estimation of the quantities of interest. Yet, some nuclear instrumentation calculations inherently need to work with statistical weights equal to 1, since either individual events have to be collected (such as the arrival of a particle at a detector, the measurement of a time of flight, etc), or the coincidence of events or also correlations between individual events have to be taken into account. To address these specific applications with Monte-Carlo simulation codes, users need a full analog simulation mode. The continuous-energy Monte-Carlo code TRIPOLI4{sup R} is mainly dedicated to shielding, reactor physics and criticality safety calculations. Its capabilities have recently been extended to widen its use to nuclear instrumentation with the possibility of γ-spectrometry calculations and the simulation of photonuclear reactions for instance. Other features needed by nuclear instrumentation applications have been available in TRIPOLI-4 for a long time, such as the sampling of the time variable and the possibility of tallying in a time grid for most of the available tallies (fluxes, reaction rates, dose equivalent rates, energy depositions, etc). In TRIPOLI-4, the transport between two consecutive collisions is analog if no variance reduction technique is requested by the user to handle deep-penetration configurations. However, up to the version 9 of the code, the collision itself is sampled in a non-analog way. This paper presents a first implementation of a full analog neutron transport mode in TRIPOLI-4, preliminary verification results and an application of this functionality to the simulation of the Nucifer detector located in Saclay, France. It should be noted that only neutron transport is dealt with in this work and that all nuclear data come from JEFF-3.1.1 or ENDF/B-VII.0 evaluations, including fission data when needed. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

EXSAN: An Interactive Version of the Nuclear Cross Section Data Handbook - 25687

Neutron cross section measurements and data files have advanced significantly since 1989 when Los Alamos published 'A Nuclear Cross Section Data Handbook', a detailed compendium of point-wise cross section plots and pie charts of relative contributions of individual reactions to the total cross section for 129 isotopes. Other compendiums with similar data and analysis tools have also been published. The intent of this work is to develop a modern, open-source application for interactive exploration and analysis of Evaluated Nuclear Data File (ENDF) libraries that also allows users to create their own 'Nuclear Cross Section Data Handbooks'. EXSAN is an easy-to-use graphical user interface application for exploring ENDF photon and neutron cross sections developed in Python. In addition to interactive plotting, EXSAN includes methods for computing rank-order lists of cross section for any energy and calculating composite cross sections for isotopic and elemental compositions and additional batch automation features. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Spectral indices measurements using miniature fission chambers at the MINERVE zero-power reactor at CEA using calibration data obtained at the BR1 reactor at SCK.CEN

Spectral indices are parameters of major importance to characterize a multiplying medium and to evaluate performances of neutronics calculation tools as well as quality of associated nuclear data. Experiments performed in 2004 at the CEA MINERVE facility loaded with the R1-UO{sub 2} lattice [1], using homemade miniature fission chambers and calibration data acquired at the SCK.CEN BR1 facility in 2001 [2], resulted in ambivalent conclusions. On one hand, spectral indices involving only fissile isotopes gave relevant results and consistent discrepancies between calculation and experiment. On the other hand, spectral indices involving both fissile and fertile isotopes showed inconsistent results depending on the type of calibration data used. In particular, the {sup 238}U(n,f)/{sup 235}U(n,f) spectral indices resulted in values far from the calculations in all cases. In 2004, those differences between measurement and calculation were mainly attributed to an imprecise knowledge of the isotopic composition of the deposits loaded in the {sup 238}U chambers. At that time, priorities in the development of programs in MINERVE and other considerations about the manufacturing and calibration of new fission chambers did not allow to further investigate these discrepancies. In 2009, the preparation of a new program at the EOLE facility [1] and changes in the regulatory framework for management of fission chambers motivated the manufacturing of new detectors. At the same time, the re-installation of the R1-UO{sub 2} lattice in MINERVE gave the opportunity to carry out a new spectral indices measurement campaign. Nevertheless, although the isotopic composition of active deposits was better known than previously, the comparison between experimental results and calculations still resulted in inconsistent discrepancies. A sensitivity study indicated afterwards that, among all parameters to be considered for the analysis and the assessment of final uncertainty, calibration data have the greatest impact. In April 2010, a new calibration campaign conducted again at the BR1 facility allowed the CEA to reanalyze the spectral indices measurements performed in 2009. With this new set of calibration data, the experimental values of spectral indices finally matched the calculation results within the uncertainty margins. In addition, the confrontation of data from 2001 and 2010 calibration campaigns, both performed with the same experimental conditions, allowed to shed on the light dead time correction issues in the monitoring of calibration measurements. At the end, this also explained the inconsistencies observed during the 2004 campaign. This paper first, presents the two different analysis methods for getting the experimental value of a spectral index and, lists main parameters that influence the determination of the experimental value. It then details the calibration processes that are set-up at the MINERVE and BR1 facilities, describes the various experiments carried out and finally comments the results obtained. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗