Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

New developments for the determination of the response function for a BC501A compact neutron spectrometer for fusion diagnostics

The compact neutron spectrometer project was initiated to develop a device able to study fast neutrons produced by fusion reactions in a tokamak. The goal is to provide a fully characterized BC501A detector using a digital acquisition system developed by ENEA. The pulse height resolution and the response matrix of the detector are determined using experimental data acquired at the PTB facility. To achieve this goal, methods of data analysis involving entropy maximization and new software were developed. The methods are described and the current results for the pulse height resolution are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The {tau}-contamination in the golden channel at the Neutrino Factory

Experimental results could lead to wrong measurements of the neutrino oscillation parameters if the so-called {tau}-contamination is not properly taken into account in the data analysis. It was shown in [1] that, if a migration matrix giving the energy distribution of muon neutrinos coming from tau-decays in the detector is included, the analysis can be done in the reconstructed neutrino energy and the problem is solved for the golden channel. We will also present some preliminary results for the disappearance channel, where the {tau}-contamination is more severe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Update on NiCE Support for BISON

The Nuclear Energy Advanced Modeling and Simulation program (NEAMS) from the Department of Energy s Office of Nuclear Energy has funded the development of a modeling and simulation workflow environment to support the various codes in its nuclear energy scientific computing toolkit. This NEAMS Integrated Computational Environment (NiCE) provides extensible tools and services that enable efficient code execution, input generation, pre-processing visualizations, and post-simulation data analysis and visualization for a large portion of the NEAMS Toolkit. A strong focus for the NiCE development team throughout FY 2015 has been support for the Multiphysics Object Oriented Simulation Environment (MOOSE) and the NEAMS nuclear fuel performance modeling application built on that environment, BISON. There is a strong desire in the program to enable and facilitate the use of BISON throughout nuclear energy research and industry. A primary result of this desire is the need for strong support for BISON in NiCE. This report will detail improvements to NiCE support for BISON. We will present a new and improved interface for interacting with BISON simulations in a variety of ways: (1) improved input model generation, (2) embedded mesh and solution data visualizations, and (3) local and remote BISON simulation launch. We will also show how NiCE has been extended to provide support for BISON code development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Compton-Thick AGN in Our Cosmic Backyard: Unveiling the Buried Nucleus in NGC 1448 with NuSTAR

NGC 1448 is one of the nearest luminous galaxies [L(sub 8) - 1000 micrometers is greater than 10(exp. 9) Solar Luminosity] to ours (z = 0.00390), and yet the active galactic nucleus (AGN) it hosts was only recently discovered, in 2009. In this paper, we present an analysis of the nuclear source across three wavebands: mid-infrared (MIR) continuum, optical, and X-rays. We observed the source with the Nuclear Spectroscopic Telescope Array (NuSTAR), and combined these data with archival Chandra data to perform broadband X-ray spectral fitting ( approx. equals 0.5 - 40 keV) of the AGN for the first time. Our X-ray spectral analysis reveals that the AGN is buried under a Compton-thick (CT) column of obscuring gas along our line of sight, with a column density of N(sub H)(los) approx. greater than 2.5 x 10(exp. 24) cm(exp. -2). The best-fitting torus models measured an intrinsic 2-10 keV luminosity of L(sub 2)-10,int = (3.5 - 7.6) x 10(exp. 40) erg s(exp. -1), making NGC 1448 one of the lowest luminosity CTAGNs known. In addition to the NuSTAR observation, we also performed optical spectroscopy for the nucleus in this edge-on galaxy using the European Southern Observatory New Technology Telescope. We reclassify the optical nuclear spectrum as a Seyfert on the basis of the Baldwin- Philips-Terlevich diagnostic diagrams, thus identifying the AGN at optical wavelengths for the first time. We also present high spatial resolution MIR observations of NGC 1448 with Gemini/T-ReCS, in which a compact nucleus is clearly detected. The absorption-corrected 2-10 keV luminosity measured from our X-ray spectral analysis agrees with that predicted from the optical [O III] Lamda 5007 A emission line and the MIR 12 micrometer continuum, further supporting the CT nature ofthe AGN.

galaxies: active – galaxies: nuclei – techniqu↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coupling SCALE with DAKOTA for Axial Burnup Profiles Assessment in Burnup Credit

This paper presents a computational study that demonstrates the application of the SCALE code system in conjunction with the Design Analysis Kit for Optimization and Terascale Applications (DAKOTA) for the analysis of key factors influencing the evaluation of burnup credit (BUC) in pressurized water reactors (PWRs). The primary objective of this analysis is to characterize the model by utilizing parameterization, uncertainty quantification, and optimization studies. Using this approach, we can comprehensively assess the system and conduct informed predictive studies. This study highlights the effectiveness of the SCALE code system integrated within the DAKOTA framework in terms of efficiency and capability. With the coupling of the burnup code ORIGAMI with the CSAS or TSUNAMI-3D sequence embedded in a DAKOTA analysis, we can characterize the factors that influence the k eff of PWR 17x17 spent nuclear fuel (SNF) in the GBC-32 computational benchmark cask for the assessment of BUC in criticality safety analysis. The coupling methodology used in this study is not exclusive to BUC analysis. However, the choice to apply this methodology to the BUC problem is particularly significant because of the diverse range of aspects it encompasses in nuclear criticality safety analyses. This problem presents a unique opportunity to explore and address multiple facets of such analyses related to BUC and illustrates the capability of the SCALE code system with DAKOTA. This analysis makes use of historical reference data for the axial burnup profile, where the entire space within the bounds is considered. Both SCALE and DAKOTA are currently integrated in the Nuclear Energy Advanced Modeling Simulation (NEAMS) Workbench code system, which has a user-friendly graphical interface that simplifies the setup of simulations and configuration of input parameters as well as the visualization of simulation results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on INL Activities for Uncertainty Reduction Analysis of FY12

The work scope of this project related to the Work Packages of “Uncertainty Reduction Analyses” with the goal of reducing nuclear data uncertainties is to produce a set of improved nuclear data to be used both for a wide range of validated advanced fast reactor design calculations, and for providing guidelines for further improvements of the ENDF/B files (i.e. ENDF/B-VII, and future releases). Recent extensive sensitivity/uncertainty studies, performed within an international OECD-NEA initiative, have quantified for the first time the impact of current nuclear data uncertainties on design parameters of the major FCR&D and GEN-IV systems, and in particular on Na-cooled fast reactors with different fuels (oxide or metal), fuel composition (e.g. different Pu/TRU ratios) and different conversion ratios.

99 GENERAL AND MISCELLANEOUS↗

Mass dispersion in transfer reactions with a stochastic mean-field theory

Nucleon transfer in symmetric heavy-ion reactions at energies below the Coulomb barrier is investigated in the framework of a microscopic stochastic mean-field theory. Although mean field alone is known to significantly underpredict the dispersion of the fragment mass distribution, a considerable enhancement of the dispersion is obtained in the stochastic mean-field theory. The variance of the fragment mass distribution deduced from the stochastic theory scales with the number of exchanged nucleons. Therefore, the new approach provides the first fully microscopic theory consistent with the phenomenological analysis of the experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Report on Project “Ton-scale Germanium: Beyond Zeptobarn WIMP Cross-section”

The DOE CAREER proposal primarily focused on establishing a modern semiconductor detector fabrication facility that would provide significant improvement in the cost profile and performance of the cryogenic semiconductor detectors used by the CDMS experiment so as to enable a next generation ton-scale experiment. The proposal also included significant work on performing data analysis on the Soudan experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty about the Uncertainty [Slides]

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable result in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates, in comparison to the measurement uncertainty. Range of true values depends on the physics of the experiment, while measurement uncertainty depends on the measurement method (properties of the detector not of the experiment). When data from one–of–a kind experiment are analyzed, only the measurement uncertainty is reported. It gives no information about the range, in which the true values of experiment would spread if the experiment was repeated. A frequently used approximation, that if a physical quantity is measured as a function of time, only measurement of this quantity, produces uncertainty is also in some real experiments fare to strong. Example: In reaction history time measurement uncertainty propagated to alpha dominated under certain conditions over the flux measurement uncertainty propagated to alpha. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization Sensitivity of the DAGATA Polarimeter

In comparison to common Compton Polarimeters the DAGATA (Darmstadt GAmma-ray Tracking Assembly) polarimeter will significantly enhance the sensitivity for gamma-rays above 4 MeV making use of its large volume 36-fold segmented HPGe AGATA crystal and the resulting superior position resolution. Results from Monte Carlo Simulations will be presented as well as approaches for data analysis to further improve the sensitivity. Application limits and realistic simulated spectra will be compared to results from existing polarimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a digital data acquisition system and optimization of n-{gamma} discrimination for a compact neutron spectrometer

A compact NE213 liquid scintillation neutron spectrometer with a new digital data acquisition (DAQ) system is now in operation at the Physikalisch-Technische Bundesanstalt (PTB). With the DAQ system, developed by ENEA Frascati, neutron spectrometry with high count rates in the order of 5x10{sup 5} s{sup -1} is possible, roughly an order of magnitude higher than with an analog acquisition system. To validate the DAQ system, a new data analysis code was developed and tests were done using measurements with 14-MeV neutrons made at the PTB accelerator. Additional analysis was carried out to optimize the two-gate method used for neutron and gamma (n-{gamma}) discrimination. The best results were obtained with gates of 35 ns and 80 ns. This indicates that the fast and medium decay time components of the NE213 light emission are the ones that are relevant for n-{gamma} discrimination with the digital acquisition system. This differs from what is normally implemented in the analog pulse shape discrimination modules, namely, the fast and long decay emissions of the scintillating light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Classification and imaging of spent nuclear fuel dry casks using cosmic ray muons - 132

The present work explores alternative approaches for in situ monitoring with near real-time data analysis and imaging of dry casks using muons. Monitoring can provide useful signals about the cask contents in a yes/no decision format faster and with fewer muons than traditional imaging. Imaging can be performed as a second step in this process if specific information about the location of the fuel assemblies is needed. To explore and analyze these two modalities, simulations of muon scattering and displacement were performed for various scenarios, including vertical and horizontal fully loaded dry casks, half-loaded dry casks, dry casks with one row of fuel assemblies missing, dry casks with one fuel assembly missing, and empty dry casks. This work demonstrates monitoring can provide fast and reliable indication about the contents of the cask. For 100,000 muons, a few minutes of measurement time with a 3.6 m{sup 2} detector at a 45 deg. zenith angle, 90% detection probability for missing fuel assemblies can be achieved with a false alarm rate lower than 1%. If a positive signal is detected, then longer measurements can be performed and coupled with muon imaging algorithms to determine the location of missing nuclear material. In these cases, transmission muon radiography can produce images of acceptable resolution for all scenarios. In the horizontal dry cask case, all scenarios can be identified and separated adequately. In the vertical dry cask case, similar conclusions can be drawn, but because of shadowing from other fuel assemblies, the location of a missing fuel assembly cannot be identified in the 2-D transmission map. However, views from different directions may resolve this. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unitarity bound for gluon shadowing

Although at small Bjorken x gluons originated from different nucleons in a nucleus overlap in the longitudinal direction, most of them are still well separated in the transverse plane and therefore cannot fuse. For this reason the gluon density in nuclei cannot drop at small x below a certain bottom bound, which we evaluated in a model independent manner assuming the maximal strength of gluon fusion. We also calculated gluon shadowing in the saturated regime using the Balitsky-Kovchegov equation and found the nuclear ratio to be well above the unitarity bound. The recently updated analysis of parton distributions in nuclei, including BNL Relativistic Heavy Ion Collider (RHIC) data on high-p{sub T} hadron production at forward rapidities, led to strong gluon shadowing. Such strong shadowing and therefore the interpretation of the nuclear modification of the p{sub T} spectra in dA collisions at RHIC seem to be inconsistent with this unitarity bound.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Review of the Nuclear Energy Agency (NEA) Ancillary Thermodynamic Database (TDB) Volume (DRAFT REV. 0)

The Nuclear Energy Agency (NEA) Ancillary data volume comprises thermodynamic data of mineral and aqueous species that, in addition to Auxiliary Data (as referred to in previous NEA thermodynamic data volumes), is necessary to calculations of chemical interactions relevant to radioactive waste management and nuclear energy. This SAND report is a review of the NEA Ancillary data critical reviews volume of thermodynamic data parameters. The review given in this report mainly involves data comparison with other thermodynamic data assessments, analysis of thermodynamic parameters, and examination of data sources. Only new and updated data parameters were considered in this review. Overall, no major inconsistencies or errors were found as allowed by the comparisons conducted in this review. Some remarks were noted, for example, on the consideration of relevant studies and/or comparisons on the analysis and retrieval of thermodynamic data parameters not cited in the respective sections.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of the 235U Covariance Data in Benchmark Calculations

The error estimation for calculated quantities relies on nuclear data uncertainty information available in the basic nuclear data libraries such as the U.S. Evaluated Nuclear Data File (ENDF/B). The uncertainty files (covariance matrices) in the ENDF/B library are generally obtained from analysis of experimental data. In the resonance region, the computer code SAMMY is used for analyses of experimental data and generation of resonance parameters. In addition to resonance parameters evaluation, SAMMY also generates resonance parameter covariance matrices (RPCM). SAMMY uses the generalized least-squares formalism (Bayes method) together with the resonance formalism (R-matrix theory) for analysis of experimental data. Two approaches are available for creation of resonance-parameter covariance data. (1) During the data-evaluation process, SAMMY generates both a set of resonance parameters that fit the experimental data and the associated resonance-parameter covariance matrix. (2) For existing resonance-parameter evaluations for which no resonance-parameter covariance data are available, SAMMY can retroactively create a resonance-parameter covariance matrix. The retroactive method was used to generate covariance data for 235U. The resulting 235U covariance matrix was then used as input to the PUFF-IV code, which processed the covariance data into multigroup form, and to the TSUNAMI code, which calculated the uncertainty in the multiplication factor due to uncertainty in the experimental cross sections. The objective of this work is to demonstrate the use of the 235U covariance data in calculations of critical benchmark systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the need for an update of a probabilistic seismic hazard analysis using a SSHAC Level 1 study and the Seismic Hazard Periodic Reevaluation Methodology

A key decision for nuclear facilities is evaluating the need for an update of an existing seismic hazard analysis in light of new data and information that has become available since the time that the analysis was completed. We introduce the newly developed risk-informed Seismic Hazard Periodic Review Methodology (referred to as the SHPRM) and present how a Senior Seismic Hazard Analysis Committee (SSHAC) Level 1 probabilistic seismic hazard analysis (PSHA) was performed in an implementation of this new methodology. The SHPRM offers a defensible and documented approach that considers both the changes in seismic hazard and engineering-based risk information of an existing nuclear facility to assess the need for an update of an existing PSHA. The SHPRM has seven evaluation criteria that are employed at specific analysis, decision, and comparison points which are applied to seismic design categories established for nuclear facilities in United States. The SHPRM is implemented using a SSHAC Level 1 study performed for the Idaho National Laboratory, USA. The implementation focuses on the first six of the seven evaluation criteria of the SHPRM which are all provided from the SSHAC Level 1 PSHA. Finally, to illustrate outcomes of the SHPRM that do not lead to the need for an update and those that do, the example implementations of the SHPRM are performed for nuclear facilities that have target performance goals expressed as the mean annual frequency of unacceptable performance at 1x10 -4 , 4x10 -5 and 1x10 -5 .

58 GEOSCIENCES↗