Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPERATION AND MAINTENANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Empirical Indicators of Transmission Value in the Southeast United States

Concurrent differences in energy price between different parts of the electric grid are a key indicator of the value of additional transmission. In areas without a wholesale electricity market, such as the Southeast, an alternative indicator to price is the Federal Energy Regulatory Commission’s (FERC) system lambda data. This economic metric represents the minimized marginal production costs of thermal generators, including fuel and other variable operation and maintenance expenses. Balancing Authorities report a single system lambda for their entire balancing area. Most Southeastern lambdas exhibit sufficient price variation to support a transmission valuation analysis, although incomplete accounting of congestion costs or scarcity rents during peak load hours may underestimate the true value of transmission capacity. With transmission value defined as the annual average hourly absolute price difference between two regions and FERC’s system lambda data used as a price proxy, we find the following results in the Southeast region during 2012-2023 (reported in $\$2024$/MWh): Intra‐regional findings: Annual averages historically span $\$2$–$\$28$/MWh and average $\$12$/MWh in SERTP and span $\$4$–$\$19$/MWh and average $\$9$/MWh in FRCC, disregarding transmission value driven by anomalous data. The ranges of transmission value reported here are large, spanning an order of magnitude in some cases. Much of this variation is driven by year-to-year changes, with 2022 having a particularly high intra-regional transmission value due to elevated natural gas prices. Inter‐regional corridors: Annual average transmission values across three broader regions range from $\$6$ to $\$28$/MWh with a long-term average of $\$11$/MWh. Much of the transmission value is concentrated in a small portion of hours. Across all regions, severe weather—particularly polar vortex events in January 2018, February 2021, and December 2022—drives the largest price spreads. Seasonal patterns also emerge, with summer afternoons and fall mornings contributing consistently to transmission value, as for example between MISO and SOCO in 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Tabletop Exercise for Small Modular Reactor Facilities

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping costs reasonable to make nuclear energy competitive. This evolving threat landscape includes adversaries having offensive cyber capabilities to attack information technology (IT) systems and operation technology (OT) systems. These adversaries may have the ability to attack the physical protection system (PPS) networks with potential consequential impacts that could degrade the effectiveness of the PPS. These cyber attacks may also be used to attack the safety and operational systems used to operate and ensure the safety of the reactor. Additionally, adversaries may gain access to unmanned aerial systems (UAS) that may be used to provide reconnaissance and surveillance of the facility, provide information to the adversaries, and be equipped with kinetic capabilities such as explosives or weapons that can be used to directly attack the facility. The Department of Energy’s Office of Nuclear Energy’s Advanced Reactor Safeguards and Security (ARSS) program funded Sandia National Laboratories (SNL) and Idaho National Laboratory (INL) to develop a cyber-physical tabletop exercise (TTX). This exercise was conducted on a hypothetical small modular reactor (SMR) facility, and only considered a potential adversary cyber attack on the PPS to a physical attack on the hypothetical facility to achieve a radiological release. This cyber-physical TTX is meant to provide lessons learned to integrate the cyber security system design and the physical protection system (PPS) design to decrease design, operation, and maintenance costs as well as increase effectiveness for defending against design basis threat attacks at the facility. This TTX will also provide a framework and method for SMR and microreactor vendors to conduct their own cyber-physical TTX and gain impactful insights to improving the cyber and physical protection system design for their SMR or microreactor facility design.

42 ENGINEERING↗

Building Performance Standards and Energy Code Alignment - Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets. However, some new buildings may struggle with meeting the BPS for the following reasons: 1. Energy codes focus on the design of the building and its projected ability to perform efficiently, while BPS compliance is dependent on the actual ongoing performance of the building, considering variables like occupancy, operation, and maintenance. 2. There are significant differences in the methodologies used to determine BPS compliance versus code compliance, including how each handles compliance metrics, handling of building amenities, and renewable energy generation. 3. The prescriptive compliance path in the energy code is based on performance of individual building components, as opposed to the performance compliance path which accounts for holistic building design strategies and interdependent building systems. This can result in a significant variability in post-occupancy performance for buildings built using the prescriptive path. Designs on the lower end of the permitted efficiency range may struggle with meeting the BPS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life-Cycle Cost Analysis Framework for Water Efficiency Measures

Life-Cycle Cost Analysis Framework for Water Efficiency Measures: Guidance Designed for Federal Agencies (hereafter referred to as “this report”) provides a technical framework for federal agencies to conduct a life-cycle cost analysis (LCCA) for water efficiency projects in accordance with 42 U.S.C. § 8253. This report leverages insights from the 2023 report, PNNL-34006, Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition (Unger et al. 2023). The primary objective of this report is to provide a framework to assist federal agencies with evaluating the full economic impact of water efficiency projects by assessing both initial investments and long-term operational benefits. An LCCA can provide a comprehensive view of all costs associated with a water efficiency project, including initial investment, ongoing operations and maintenance (O&M), and eventual disposal or replacement, ensuring the most cost-effective solution is selected. The LCCA methodology outlined in this report enables users to compare base case scenarios with potential alternatives using a standardized present value approach. It incorporates key cost components such as energy, water and wastewater, installation, O&M, and equipment replacement. Additionally, the framework introduces relevant evaluation metrics, such as the net savings and the savings-to-investment ratio, to ensure that water efficiency measures are economically justified over the lifespan of the project. To support practical application, this report also describes various water efficiency strategies that may be analyzed using an LCCA, including plumbing retrofits, irrigation upgrades, alternative water use, and cooling system improvements. By applying this framework, federal agencies can ensure compliance with regulatory mandates while maximizing the return on investment and contributing to resilient water management practices. The information provided in this report is aligned with the Federal Energy Management Program (FEMP) life-cycle cost (LCC) methodology, as conveyed in National Institute of Standards and Technology (NIST) Handbook 135 (Kneifel and Webb 2022). This report is intended to provide relatively high-level guidance, acting as a complement to, rather than a substitute for, that resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Brewer Recreational Facility Energy Modernization Project (Final Technical Report)

The project replaced a thirty-four-year-old metal halide lighting system on the City's primary athletic field with new energy efficient LED lighting, significantly reducing operating and maintenance cost while providing a safer environment, additional recreational opportunities, improved energy efficiency, and reduced light spillover.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Upgrading Linear Fluorescent Fixtures to LED in Schools

Lighting is a key component to creating a functional and high-quality learning environment for students and staff. Light-emitting diode or LED lighting fixtures have gained traction in common commercial building applications and quality replacement options for common fixture types are widely available. Compared to most fluorescent lighting systems, using LEDs can reduce energy consumption and therefore decrease carbon dioxide emissions, reduce maintenance and operation cost, and improve the visual appearance and lighting quality of the classroom and school environments. When additional controls are considered, more energy can be saved and some controls, like dimming, can offer amenities to occupants. As LEDs become an even more prominent lighting technology, fluorescent equipment may become challenging or expensive to replace. Additionally, school buildings are typically in use for many decades; maintaining a long-term view can be important when deciding which upgrade path to take. This fact sheet provides guidance on the various factors to consider when deciding on an LED upgrade for fluorescent lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vanderbilt CMS Heavy-Ion Tier-2 Facility (Final Report)

The CMS experiment at the LHC at CERN in Geneva, Switzerland spends a portion of its running time colliding heavy ions. These heavy ion collisions are a key probe of a state of matter known as a Quark Gluon Plasma, which is a state of matter found in the very early universe 10s of microseconds after the big bang. These collision data are recorded by the CMS experiment and then undergo several stages of refinement to extract physics properties of the collisions from the raw data recorded by the various detector subsystems in CMS. In addition, copies of these datasets are stored on tape archival storage for data preservation. This award funds the deployment, maintenance, and operation of a computing facility at Vanderbilt University which processes, stores, and analyzes these collision data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Guide for Creating a Building-Level Action Plan to Manage Refrigerants in Buildings

The Guide for Creating a Building-Level Action Plan to Manage Refrigerants in Buildings has been developed in response to stakeholder feedback and interest received during the Better Buildings Managing Refrigerants Working Group. This guide includes best practices and a step-by-step guide to create a plan to manage their organization's refrigerants. Stakeholders were interested in guidance for refrigerant management to help reduce costs and protect efficiency of equipment, to mitigate risk related to increased maintenance and operational budgets, and to manage costs of using legacy refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗

CyberMESA: Evaluation Procedures and Metrics for Charging Infrastructure Cybersecurity

A report detailing the cybersecurity evaluation and assessment procedures for EV charging infrastructure. This report is authored by three national lab contributors. INL, PNNL, NRL. The grid integration of Electric Vehicle Charging Infrastructure (EVCI) is a large and complex system of systems (SoS) made up of components from many manufacturers and integrated by various companies responsible for their operation and maintenance. This complexity makes it challenging to implement security standards like IEC 62443 across the entire infrastructure. This document aims to aid in the vulnerability assessments of individual devices, such as Electric Vehicle Supply Equipment (EVSE), to support vendors in adopting and implementing security standards such as UL 2900, NIST SP 800-53 and Common Criteria (CC) (ISO/IEC 15408). This document serves as a guide to help evaluate the cybersecurity posture of EVCI assets. It aims to provide a consistent method for evaluating EVCI, enabling cybersecurity research teams to systematically test a wide range of electric vehicle (EV) assets. The target audiences include cybersecurity research teams, vendor development teams, automotive OEMs, and third-party evaluators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Techno-Economic Assessment of Gas Switching Reforming (GSR) of Natural Gas for Pure Hydrogen Production and Power Generation with Integrated CO2 Capture

The increasing demand for hydrogen and the CO2 intensity of natural gas (NG) reforming motivate the development of low-carbon-emission hydrogen production technologies. Gas Switching Reforming (GSR) is an advanced auto-thermal reforming technology that produces hydrogen or syngas from natural gas. It integrates inherent CO2 capture by utilizing a specialized oxygen carrier in a single fluidized bed reactor, eliminating the need for complex, energy-intensive post-combustion separation. GSR technology builds upon Chemical Looping Reforming (CLR), an experimentally proven technology with strong potential for scaling up. In this study, select oxygen carriers (OC) (NiO/Al2O3, Fe2O3-CeO2/Al2O3, and magnetite) were tested in methane steam reforming in a fixed bed reactor to determine their relative reactivities under relevant conditions for GSR (800 °C, 7 bar total pressure). Process models were then developed to perform techno-economic analysis (TEA) of GSR for hydrogen production (GSR-H₂) and a combined cycle (GSR-CC) in which high-purity H₂ is fired in a gas turbine to produce electricity. Operating at 10 bar and 1100 °C and with the additional recovery steps implemented increased H₂ production by ~30% and improved efficiency relative to prior studies. For GSR-H₂, the levelized cost of hydrogen (LCOH) is 1.61–1.64 $/kg-H₂, competitive with a reference SMR case, though operating and maintenance costs are higher due to increased electricity demand. GSR-CC has a significantly higher levelized cost of electricity (LCOE) than its reference NGCC (natural gas combined cycle) plant, suggesting it is less competitive; however, increasing production scale could make it more attractive. Life-cycle results for GSR-H2 indicate NG consumption drives ~75% of total global warming impacts (~2.3 kg CO2 eq/kg H2). An environmental, health, and safety screening suggests iron-based carriers are comparatively safer, whereas NiO may pose greater risks. Overall, GSR-H2 is a scalable, competitive option for hydrogen production using nickel and non-nickel OC.

03 NATURAL GAS↗

Preliminary techno-economic assessment of gas switching reforming (GSR) of natural gas for pure hydrogen production and power generation with integrated CO2 capture

The increasing demand for hydrogen and the CO2 intensity of natural gas (NG) reforming motivate the development of low-carbon-emission hydrogen production technologies. Gas Switching Reforming (GSR) with integrated CO2 capture, a technology based on Chemical Looping Reforming (CLR), has been experimentally proven and shows potential for scale-up. In this study, select oxygen carriers (OC) (NiO/Al2O3, Fe2O3-CeO2/Al2O3, and magnetite) were tested in methane steam reforming in a fixed bed reactor to determine their relative reactivities under relevant conditions for GSR (800 °C, 7 bar total pressure). Process models were then developed to perform techno-economic analysis (TEA) of GSR for hydrogen production (GSR-H2) and a combined cycle (GSR-CC) in which high-purity H2 is fired in a gas turbine to produce electricity. Operating at 10 bar and 1100 °C and with the additional recovery steps implemented increased H2 production by ∼ 30% and improved efficiency relative to prior studies. For GSR-H2, the levelized cost of hydrogen (LCOH) is 1.61–1.64 $/kg-H2, competitive with a reference SMR case, though operating and maintenance costs are higher due to increased electricity demand. GSR-CC has a significantly higher levelized cost of electricity (LCOE) than its reference NGCC (natural gas combined cycle) plant, suggesting it is less competitive; however, increasing production scale could make it more attractive. Life-cycle results for GSR-H2 indicate NG consumption drives ∼ 75% of total global warming impacts (∼2.3 kg CO2 eq/kg H2). An environmental, health, and safety screening suggests iron-based carriers are comparatively safer, whereas NiO may pose greater risks. Overall, GSR-H2 is a scalable, competitive option for hydrogen production using nickel and non-nickel OC.

03 NATURAL GAS↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

FORGE: Summer Internship Experience

The presentation summarizes my summer internship experience with the Fluids Group at Fermilab. During the internship, I learned about the maintenance and operation of water pumps and other equipment that support important facility systems. I worked alongside fluids technicians and gained hands-on experience with maintaining machinery, installing pipes, refilling water, cleaning RF cavities, and observing new water-pump construction for PIP-II. My projects included repairing an air dryer, learning how heat exchangers cool low-conductivity water, and cleaning the copper cooling rings used in RF cavities. Overall, this experience helped me better understand the work processes of technicians and the importance of practical technical knowledge for engineers.

Uribe, Anthony [Unlisted, US, IL]↗

Laboratories for the 21st Century: An Introduction to Low-Energy Design (Revised)

This booklet is an introduction to several new strategies for designing, developing, and retrofitting energy-efficient laboratories. It is the result of a collaboration among staff at the U.S. Environmental Protection Agency (EPA), the U.S. Department of Energy's (DOE's) Federal Energy Management Program (FEMP), several national laboratories, and their contractors. They are collaborating to meet the goals of a joint EPA-DOE initiative, 'Laboratories for the 21st Century,' which was established to help government and private-sector laboratory designers, engineers, owners, and operators work together to increase operating efficiency and reduce costs. This booklet describes many energy-efficient strategies that can be done during laboratory planning and programming; design; engineering; and commissioning, operation, and maintenance. There is also a discussion of on-site power generation and clean sources of electricity from renewable energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test Plan to Assess Fire Effects on the Function of an Engineered Surface Barrier

Wildfire is a frequent perturbation in shrub steppe ecosystems, altering the flora, fauna, atmosphere, and soil of these systems. Research on the fire effects has focused mostly on natural ecosystems with essentially no attention on engineered systems like surface barriers. The scope of the project is to use a simulated wildfire to induce changes in an engineered surface barrier and document the effects on barrier performance. The main objective is to quantify the effects of burning and the resulting post-fire conditions on alterations in soil physical properties; hydrologic response, particularly the water balance; geochemical properties; and biological properties. A secondary objective is to use the lessons learned to maximize fire protection in the design of long-term monitoring systems based on electronic sensors. A simulated wildfire will be initiated, controlled and monitored at the 200-BP-1 barrier in collaboration with the Hanford Fire Department during the fall of 2008. The north half of the barrier will be divided into nine 12 x 12 m plots, each of which will be randomly assigned a fuel load of 2 kg m-2 or 4 kg m-2. Each plot will be ignited around the perimeter and flames allowed to carry to the centre. Any remaining unburned vegetation will be manually burned off using a drip torch. Progress of the fire and its effects will be monitored using point measurements of thermal, hydrologic, and biotic variables. Three measures of fire intensity will be used to characterize fire behavior: (1) flame height, (2) the maximum temperature at three vertical profile levels, and (3) total duration of elevated temperature at these levels. Pre-burn plant information, including species diversity, plant height, and canopy diameter will be measured on shrubs from the plots to be burned and from control plots at the McGee ranch. General assessments of shrub survival, recovery, and recruitment will be made after the fire. Near-surface soil samples will be collected pre- and post-burn to determine changes in the gravel content of the surface layer so as to quantify inflationary or deflationary responses to fire and to reveal the ability of the surface to resist post-fire erosive stresses. Measures of bulk density, water repellency, water retention, and hydraulic conductivity will be used to characterize changes in infiltration rates and water storage capacity following the fire. Samples will also be analyzed to quantify geochemical changes including changes in soil pH, cation exchange capacity, specific surface area, and the concentration of macro nutrients (e.g. N, P, K) and other elements such as Na, Mg, Ca, that are critical to the post-fire recovery revegetation. Soil CO2 emissions will be measured monthly for one year following the burn to document post-fire stimulation of carbon turnover and soil biogenic emissions. Surface and subsurface temperature measurements at and near monitoring installations will be used to document fire effects on electronic equipment. The results of this study will be used to bridge the gaps in knowledge on the effects of fire on engineered ecosystems (e.g. surface barriers), particularly the hydrologic and biotic characteristics that govern the water and energy balance. These results will also support the development of practical fire management techniques for barriers that are compatible with wildfire suppression strategies. Furthermore, lessons learned will be use to develop installation strategies needed to protect electronic monitoring equipment from the intense heat of fire and the potential damaging effects of smoke and fire extinguishing agents. Such information is needed to better understand long-term barrier performance under extreme conditions, especially if site maintenance and operational funding is lost for activities such as barrier revegetation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lac Courte Oreilles Energy Analysis Project

The Lac Courte Oreilles Tribe applied for first step funding in 2007 and was awarded in October of that year. We wanted to perform an audit to begin fulfilling two commitments we made to our membership and resolutions that we adopted. One was the Kyoto Protocol and reduce our carbon emissions by 25% and to produce 25% of our energy by sustainable means. To complete these goals we needed to begin with first assessing what our carbon emissions are and begin taking the steps to conserve on the energy we currently use. The First Step Grant gave us the opportunity to do this. Upon funding the Energy Project was formed under the umbrella of the LCO Public Works Department and Denise Johnson was hired as the coordinator. She quickly began fulfilling the objectives of the project. Denise began by contact the LCO College and hiring interns who were able to go to each Tribal entity and perform line logging to read and document the energy used for each electrical appliance. Data was also gathered for one full year from each entity for all their utility bills (gasoline, electric, natural gas, fuel oil, etc.). Relationships were formed with the Green Team and other Green Committees in the area that could assist us in this undertaking. The Energy Task Force was of great assistance as well recommending other committees and guidance to completing our project. The data was gathered, compiled and placed into spreadsheets that would be understandable for anyone who didn't have a background in Renewable Resources. While gathering the data Denise was also looking for ways to conserve energy usage, policies changes to implement and any possible viable renewable energy resources. Changes in the social behaviors of our members and employees will require further education by workshops, energy fairs, etc.. This will be looked into and done in coordination with our schools. The renewable resources seem most feasible are wind resources as well as Bio Mass both of which need further assessment and funding to do so will be sought. While we already are in ownership of a Hydro Dam it is currently not functioning to its full capacity we are seeking operation and maintenance firm proposals and funding sources. One of our biggest accomplishment this project gave us was our total Carbon Emissions 9989.45 tons, this will be the number that we will use to base our reductions from. It will help us achieve our goals we have set for ourselves in achieving the Kyoto Protocol and saving our Earth for our future generations. Another major accomplishment and lesson learned is we need to educate ourselves and our people on how to conserve energy to both impact the environment and our own budgets. The Lac Courte Oreilles (LCO) Energy Analysis Project will perform an energy audit to gather information on the Tribe's energy usage and determine the carbon emissions. By performing the audit we will be able to identify areas where conservation efforts are most viable and recommend policies that can be implemented. These steps will enable LCO to begin achieving the goals that have been set by the Tribal Governing Board and adopted through resolutions. The goals are to reduce emissions by 25% and to produce 25% of its energy using sustainable sources. The project objectives were very definitive to assist the Tribe in achieving its goals; reducing carbon emissions and obtaining a sustainable source of energy. The following were the outlined objectives: (1) Coordinate LCO's current and future conservation and renewable energy projects; (2) Establish working relationships with outside entities to share information and collaborate on future projects; (3) Complete energy audit and analyze LCO's energy load and carbon emissions; (4) Identify policy changes, education programs and conservation efforts which are appropriate for the LCO Reservation; and (5) Create a plan to identify the most cost effective renewable energy options for LCO.

02 PETROLEUM↗