Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimal Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Silane injection in a high-density low-pressure plasma system and its influence on the deposition kinetics and material properties of SiO{sub 2}

High-rate, low temperature deposition is an essential requirement for industrial fabrication technology to be suitable for the deposition of optical and protective coatings. High-density, low-pressure plasmas have received significant attention for such applications due to their ability to create large and controllable ion fluxes onto the substrate. In this study, the high-rate deposition of silica films from a silane and oxygen gas mixture in a high-density plasma system based on a matrix distributed electron cyclotron resonance (MDECR) plasma source is investigated using directional jet injection of undiluted silane. The influence of process parameters such as the microwave power, radio frequency biasing of the substrate holder, and gas flows on the OH content of the oxide films is studied using phase-modulated spectroscopic ellipsometry (SE), Fourier transform infrared (FTIR) spectroscopy, and transmission measurements. The results of the measurements, taken at various points across the wafer, show a decrease in the thickness-normalized OH concentration in the areas of higher deposition rates. The corresponding gas phase composition is investigated using optical emission spectroscopy and compared to the FTIR, transmission and SE measurement results in order to validate our findings and ultimately optimize the deposition process. It is found that the primary silane flux onto the surface, which depends on the positioning of the jet injection point and gas flow rate, plays an important role not only on the deposition rate but also on the OH content of the films. The authors conclude that high-density plasma deposition systems such as the MDECR plasma enhanced chemical vapor deposition system cannot be considered as well mixed for gases with dissociation products that have high sticking coefficients, contrary to the accepted paradigm.

36 MATERIALS SCIENCE↗

Scattering effects at near-wall flow measurements using Doppler global velocimetry

Doppler global velocimetry (DGV) is considered to be a useful optical measurement tool for acquiring flow velocity fields. Often near-wall measurements are required, which is still challenging due to errors resulting from background scattering and multiple-particle scattering. Since the magnitudes of both errors are unknown so far, they are investigated by scattering simulations and experiments. Multiple-particle scattering mainly causes a stochastic error, which can be reduced by averaging. Contrary to this, background scattering results in a relative systematic error, which is directly proportional to the ratio of the background scattered light power to the total scattered light power. After applying a correction method and optimizing the measurement arrangement, a subsonic flat plate boundary layer was successfully measured achieving a minimum wall distance of 100 {mu}m with a maximum relative error of 6%. The investigations reveal the current capabilities and perspectives of DGV for near-wall measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comparison of GaAs and Si hybrid solar power systems

Five different hybrid solar power systems using silicon solar cells to produce thermal and electric power are modeled and compared with a hybrid system using a GaAs cell. Among the indices determined are capital cost per unit electric power plus mechanical power, annual cost per unit electric energy, and annual cost per unit electric plus mechanical work. Current costs are taken to be $35,000/sq m for GaAs cells with an efficiency of 15% and $1000/sq m for Si cells with an efficiency of 10%. It is shown that hybrid systems can be competitive with existing methods of practical energy conversion. Limiting values for annual costs of Si and GaAs cells are calculated to be 10.3 cents/kWh and 6.8 cents/kWh, respectively. Results for both systems indicate that for a given flow rate there is an optimal operating condition for minimum cost photovoltaic output. For Si cell costs of $50/sq m optimal performance can be achieved at concentrations of about 10; for GaAs cells costing 1000/sq m, optimal performance can be obtained at concentrations of around 100. High concentration hybrid systems offer a distinct cost advantage over flat systems.

Heinbockel, J. H.↗

Thermal energy management process experiment

The thermal energy management processes experiment (TEMP) will demonstrate that through the use of two-phase flow technology, thermal systems can be significantly enhanced by increasing heat transport capabilities at reduced power consumption while operating within narrow temperature limits. It has been noted that such phenomena as excess fluid puddling, priming, stratification, and surface tension effects all tend to mask the performance of two-phase flow systems in a 1-g field. The flight experiment approach would be to attack the experiment to an appropriate mounting surface with a 15 to 20 meter effective length and provide a heat input and output station in the form of heaters and a radiator. Using environmental data, the size, location, and orientation of the experiment can be optimized. The approach would be to provide a self-contained panel and mount it to the STEP through a frame. A small electronics package would be developed to interface with the STEP avionics for command and data handling. During the flight, heaters on the evaporator will be exercised to determine performance. Flight data will be evaluated against the ground tests to determine any anomalous behavior.

Ollendorf, S.↗

Blunt-nosed swept supercritical LFC wings without nose flaps

To simplify the design of swept supercritical (SC) Laminar Flow Control (LFC) wings and maintain satisfactory low speed characteristics, blunt-nosed swept SC LFC wings without nose flaps and lower wing loadings were studied. Their boundary layer crossflow in the leading edge area is optimally controlled (1) by compensating the boundary layer crossflow of the front acceleration zone by an opposite crossflow in a downstream pressure rise area, (2) by maintaining a neutrally stable boundary layer crossflow by suction within a narrow spanwise suction strip located close to the wing attachment line in the front acceleration zone. The required suction massflow and power are then very small, especially considering the strongly stabilizing effect of surface and streamline curvature on crossflow stability.

Pfenninger, W.↗

NASA Tech Briefs, April 2013

Topics covered include: Fully Integrated, Miniature, High-Frequency Flow Probe Utilizing MEMS Leadless SOI Technology; Nanoscale Surface Plasmonics Sensor With Nanofluidic Control; Advanced Dispersed Fringe Sensing Algorithm for Coarse Phasing Segmented Mirror Telescopes; Neural Network Back-Propagation Algorithm for Sensing Hypergols; Bulk Moisture and Salinity Sensor; Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing; Circularly Polarized Microwave Antenna Element with Very Low Off-Axis Cross-Polarization; Ultra-Low Heat-Leak, High-Temperature Superconducting Current Leads for Space Applications; Flash Cracking Reactor for Waste Plastic Processing; An Automated Safe-to-Mate (ASTM) Tester; Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch; Compute Element and Interface Box for the Hazard Detection System; DOT Transmit Module; Composite Aerogel Multifoil Protective Shielding; Li-Ion Electrolytes with Improved Safety and Tolerance to High-Voltage Systems; Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation; Controlled, Site-Specific Functionalization of Carbon Nanotubes with Diazonium Salts; Regenerable Sorbent for CO2 Removal; Sprayable Aerogel Bead Compositions With High Shear Flow Resistance and High Thermal Insulation Value; Lexan Linear Shaped Charge Holder with Magnets and Backing Plate; Robotic Ankle for Omnidirectional Rock Anchors; Wind, Wave, and Tidal Energy Without Power Conditioning; An Active Heater Control Concept to Meet IXO Type Mirror Module Thermal-Structural Distortion Requirement; Waterless Clothes-Cleaning Machine; Integrated Electrical Wire Insulation Repair System; LVGEMS Time-of-Flight Mass Spectrometry on Satellites; Surface Inspection Tool for Optical Detection of Surface Defects; Per-Pixel, Dual-Counter Scheme for Optical Communications; Certification-Based Process Analysis; Surface Navigation Using Optimized Waypoints and Particle Swarm Optimization; Smart-Divert Powered Descent Guidance to Avoid the Backshell Landing Dispersion Ellipse; Estimating Foreign-Object-Debris Density from Photogrammetry Data; Adaptive Sampling of Spatiotemporal Phenomena with Optimization Criteria; Building a 2.5D Digital Elevation Model From 2D Imagery; Eyes on the Earth 3D; Target Trailing With Safe Navigation for Maritime Autonomous Surface Vehicles; Adams-Based Rover Terramechanics and Mobility Simulator - ARTEMIS; ISTP CDF Skeleton Editor; Uplink Summary Generator (ULSGEN) Version 1.0; Robotics On-Board Trainer (ROBoT); Software Engineering Tools for Scientific Models; Automatic Data Filter Customization Using a Genetic Algorithm; Tracker Toolkit; Towards Efficient Scientific Data Management Using Cloud Storage; On a Formal Tool for Reasoning About Flight Software Cost Analysis; A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries; Spacecraft Crew Cabin Condensation Control; and Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex.

Source record↗

Update on Design of 10 MWe Iron-Based Coal Direct Chemical Looping Demonstration Plant

The Coal-Direct Chemical Looping (CDCL) process is emerging as a promising technology capable of high efficiency for producing electricity with low cost for carbon capture. In the CDCL process, coal is fully combusted to form carbon dioxide (CO2) and water via reaction with Fe2O3-based oxygen-carrier particles in a moving-bed reducer reactor. During reaction with coal, the Fe2O3 is reduced to form a mixture of Fe and FeO. The reduced particles are then transported to the combustor reactor where they are re-oxidized with air. The oxidation of the Fe and FeO mixture generates heat that can be used to produce steam for power generation. Once the particles are fully regenerated, they are pneumatically recycled to the reducer reactor where another reduction-oxidation (Redox) cycle begins. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been developing the CDCL technology based on iron-based metal oxide particles circulating in a moving-bed reducer coupled with an entrained-flow combustor. As part of a Phase I effort of a DOE-sponsored project, B&W identified scale-up technology gaps for the coal-direct chemical looping reactor process, most of which fall under the moving-bed reactor design and operation. However, after the Phase I research, B&W concluded that the CDCL technology has the potential of generating electricity while meeting the DOE goals of greater than 90% CO2 capture and less than 35% increase in levelized cost of electricity (LCOE). B&W then moved to a Phase II project to design, build and demonstrate the CDCL technology at a 250 kWth capacity. B&W finished the construction and commissioning of the pilot test facility in 2017. The approach used to design a 250 kWth pilot-scale CDCL facility to investigate the technology gaps is presented. Important lessons from the commissioning activities that would transfer to commercial plant start-up are also shared. The findings from the test program are being incorporated into a Pre-FEED study for a 10 MWe large pilot demonstration. Under a separately-funded heat integration project, B&W and OSU are developing a multiphase computational fluid dynamic model (MFIX) of the combustor to quantify heat transfer to embedded steam generation surface, utilizing pinch analysis (ASPEN Energy Analyzer) to identify potential improvements of the heat integration scheme, and developing an integrated dynamic model (ProTRAX) of the steam turbine coupled with the chemical looping process to identify potential start-up and transient operation issues. Under an advanced control system for optimizing operation, B&W is supporting OSU to install a rules-based optimizer (B&W’s FocalPoint) on their 25 kWt bench-scale facility on the OSU West Campus. Finally, B&W and OSU were recently selected to perform a Phase I Feasibility study to evaluate installation of the 10 MWe pilot at the Dover Power & Light Municipal Power Plant in Dover, Ohio. The feasibility study includes compiling an Environmental Information Volume and generating a cost estimate for the design, construction and commissioning of the plant as well as lining up commitments from potential project participants and funding contributors. Updates on each project will be presented. The status of the technology development will be discussed. We focus on the progress made to date towards closing the technology gaps under each project.

20 FOSSIL-FUELED POWER PLANTS↗

In-Duct and Far-Field Experimental Measrements from the ANCF for the Purpose of Improved Broadband Liner Optimization

A process for the design and evaluation of novel broadband acoustic liner concepts with limited fan source information is being evaluated. A pair of advanced broad-bandwidth liners were designed and manufactured for the NASA Glenn Research Center's Advanced Noise Control Fan (ANCF): (i) a constant impedance liner and (ii) a variable impedance liner. The insertion loss of both liners was measured in-duct utilizing the ANCF's Configurable Fan Artificial Noise System in a clean configuration with no-flow. Additionally, the acoustic characteristics of the Variable Impedance Liner were measured in the standard ANCF configuration with and without flow. The experimental setup, in-duct mode power levels, and far-field directivity are presented herein.

Acoustics↗

Coiled Tube Gas Heaters For Nuclear Gas-Brayton Power Conversion

This project developed an alternative design for heat exchangers for application to heating supercritical carbon dioxide (S-CO 2 ) or air for power conversion. We have identified an annular coiled tube bundle configuration–where hot sodium enters tubes from multiple vertical inlet manifold pipes, flows in a spiral pattern radially inward and downward, and then exits into an equal number of vertical outlet manifold pipes–as a potentially attractive option. The S-CO 2 gas or air flows radially outward through the tube bundle. Coiled tube gas heaters (CTGHs) are expected to have excellent thermal shock, long-term thermal creep, in-service inspection, and reparability characteristics, compared to alternative options. CTGHs have significant commonality with modern nuclear steam generators. Extensive experience exists with the design, manufacture, operation, in-service inspection and maintenance of nuclear steam generators. The U.S. Nuclear Regulatory Commission also has extensive experience with regulatory guidance documented in NUREG 0800. CTGHs leverage this experience and manufacturing capability. The most important difference between steam generators and gas-Brayton cycles such as the S-CO 2 cycle is that the heat exchangers must operate with counter flow with high effectiveness to minimize the pinch-point temperature difference between the hot liquid coolant and the heated gas. S-CO 2 -cycle gas heaters also operate at sufficiently elevated temperatures that time dependent creep is important and allowable stresses are relatively low. Designing heat exchangers to operate in this regime requires configurations that minimize stresses and stress concentrations. The cylindrical tubes and cylindrical manifold pipes used in CTGHs are particularly effective geometries. The first major goal of this research project was to develop and experimentally validate a detailed, 3-D multi-phase (gas-solid-liquid) heat transport model for CTGHs, using methods similar to earlier UCB multi-scale models for PCHEs, which will enable optimization of CTGH designs with respect to the number of manifold pipes, S-CO 2 and sodium circulating power, and other design parameters. CTGHs are relatively novel because the tubes loaded in compression as well as the manifold pipes which form the tube sheets. The second major goal of the experimental and modeling effort was to optimize the assembly and heat treatment of the tube-to-tubesheet joints, using a novel tapered joint configuration, and to develop diffusion-bonded joints with high shear strength and creep resistance, as has been done in other applications for tapered plugs. The project would also conduct creep testing of these tubesheet joints in pressurized furnaces under prototypical conditions of stress and temperature, however this was not feasible due to numerous hinderances. Detailed microstructural investigations was conducted on the diffusion bond interface, while the bond strength was evaluated by tensile testing. The mechanical testing quantified the overall strength of the bond and measured the pull out force as well as long term behavior, which complemented the microstructural analysis and gave a complete understanding of the diffusion bond.

30 DIRECT ENERGY CONVERSION↗

Effect of Cellular Lattices, Heat-Exchange Intensifiers, and Coolant Mixing on the Critical Power of VVER FA

The results of one stage in the development of methods for increasing the critical power of water-cooled nuclear reactors – the capacity of a reactor installation with sharp degradation of the heat exchange characteristics of the coolant (crisis of heat exchange) – are presented. This stage included experimental determination of the effect on the crisis of heat exchange of arranging heat-exchange intensifiers in FA and transverse mixing of the coolant flow, for which lattices assembled from properly shaped cellular elements where used. The FA models consisted of an assembly of 19 fuel-element simulators with a non-uniform distribution of heat emission along the length. Freon-12 was used as the coolant. The models of the FA differed by the type of intensifier lattices and the number of FA arranged along the length. The efficacy of the influence of lattices on the critical power as a result of the intensification of heat exchange and transverse mixing of the coolant was determined separately. The optimal rigging of FA with lattices was determined experimentally.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Chapter 2: Global Value Chain and Manufacturing Analysis on Geothermal Power Plant Turbines

The global geothermal power market has shown significant growth since the last decade and is expected to reach a total installed capacity of 18.4 gigawatts electric (GWe) by the end of 2021 (GEA, 2016). The global geothermal power plant turbine market is dominated by a small number of manufacturers. Between 2005 and 2015, 82% of the geothermal steam turbines were manufactured in Japan, and 74% of the geothermal binary cycle turboexpanders were manufactured in Israel. During this period, the United States played an important role in the global trade flow of fully assembled turbine units and turbine parts, with a high volume of imports and exports. Another significant growth area was in Italian turbine/turboexpander manufacturers, who have increased their market share in the last couple of years. One other important change in the manufacturing market was in Turkey, where the bonus on feed-in-tariff (FIT) for domestic hardware components boosted the national manufacturing sector between 2010 and 2020. When planning geothermal power projects, developers customize their power plant size to fit the available geothermal resource capacity. The turbine is designed and sized to optimize the efficiency and utilization of resource and revenue production. The rest of the power plant components such as heat exchangers (HX), water-cooled cooling towers (WCCT), or air-cooled condensers (ACC) are then chosen to complement the turbine size and design. These one-off manufacturing custom design turbines have relatively higher manufacturing set-up costs, longer lead times, and higher capital costs than the standard design turbines manufactured in larger volumes. However, turbines produced in standard increments and in larger manufacturing volumes could result in lower costs per turbine, but potentially lower efficiency. Based on pipeline projects and resource assessments, there is significant potential value in creating standard turbine sizes that could offer an economic advantage, as is done for modular microturbines.

40 EE - Geothermal Technologies Office (EE-4G)↗

Hydrokinetic energy conversion using flow induced oscillations of single-cylinder with large passive turbulence control

Various types of flow-induced oscillations (FIOs) have been implemented in development of marine hydrokinetic (MHK) energy converters. With passive turbulence control (PTC), energy harvesting starts at a flow speed of about 0.5 m/s. However, there is worldwide MHK energy available in even slower currents. In the present study, the effect of damping on FIO and power extraction is investigated for a converter with large turbulence stimulation (PTC) consisting of straight strips with a height of 15% of the cylinder diameter and placed symmetrically on the cylinder surface. The oscillating amplitude decreases, as the damping ratio increases, with unchanged sinusoidal pattern of the displacement time-history. The frequency ratio is also affected by damping especially in the VIV initial branch and transition region between VIV and galloping. An important flow characteristic of the large-PTC cylinder is that a recirculation region is formed behind the PTC, causing appreciable disturbance to the flow past the cylinder. Power can be harvested in the whole FIO range and the harnessed power maximum appears at the largest inflow velocity tested. However, the optimum of harnessing efficiency is located at the beginning of the VIV upper branch. The gap between VIV and galloping is bridged when large PTC is used, eliminating the drop in power and efficiency even at higher damping, which would be a weakness of regular-PTC cylinder for energy harvesting. Finally, the mechanism behind the variation of harnessing efficiency with inflow velocity and damping ratio is revealed, and the optimality criterion for the converter design is discussed.

16 TIDAL AND WAVE POWER↗

The formation of an radial edge electric field due to finite ion orbit width effects is the possible root cause of the H-mode edge

Abstract Full orbit-following simulations of thermal ions show that finite ion-orbit width effects create charge separation near the last closed flux surface (LCFS) which generates a localized radial electric field. Experimentally, edge electric fields are observed in H-mode plasmas and they are necessary for the edge turbulence suppression via the E × B flow shear mechanism. Confined trapped (and to a lesser extent co-passing) ions near the plasma edge form a positive charge distribution outside the LCFS, while thermal electrons are tied more tightly to field lines owing to their small mass and are poorly confined outside the LCFS, hence charge neutrality is violated outside the LCFS. A large number of reported observations from spherical and conventional tokamaks support the results from the simulations although the simulations were not performed fully self consistently. The results suggest ways to lower the H-mode power threshold and optimize the H-mode plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilization of Wet Forest Biomass as both the Feedstock and Electricity Source for an Integrated Biochar Production System

Abstract. A belt dryer and gasifier generator set were integrated into a biochar production plant to use process heat to dry biomass feedstock from forest residuals and to provide electric power to the plant using a side stream of dried biomass. Experiments were conducted to characterize the dryer throughput and drying capacity using process heat from a stack heat exchanger attached to the biochar machine flare. A matrix of tests was conducted at high and low flow rates for both the heat exchanger air flow rate (which varied the temperature and heat input to the dryer) and the residence time of feedstock in the belt dryer. Mean feedstock input moisture during dryer characterization was 45% and the mean moisture after exiting the dryer was 27%. The optimal test condition, providing the greatest water removal rate, was determined to have high air flow rate through the heat exchanger and short dryer residence time. This condition was used to demonstrate the integrated system for an 8-h production day. The integrated system dried incoming feedstock from 36% to 22% with a dryer throughput rate of 495 kg h -1 w.b. and an evaporation rate of 88.8 kg h -1 , providing the necessary dry feedstock for the 20-kW gasifier generator set and the biochar machine, which produced 75 kg h -1 of biochar. This system required the operational effort of 0.92 labor hours per production hour. Results from this demonstration indicate that the integrated system provides key benefits in a biochar production operation including greater control of feedstock drying and the ability to operate without an external (non-biomass) source of fuel for electricity generation. Keywords: Biochar, Biomass, Biomass drying, Forest residuals, Gasification, Pyrolysis.

Agriculture↗

ADMS State of the Industry and Gap Analysis

An Advanced distribution management system (ADMS) is a platform for optimized distribution system operational management. This platform comprises of distribution management system (DMS) applications, supervisory control and data acquisition (SCADA), outage management system (OMS), and distributed energy resource management system (DERMS). One of the primary objectives of this work is to study and analyze several ADMS component and auxiliary systems. All the important component and auxiliary systems, SCADA, GISs, DMSs, AMRs/AMIs, OMSs, and DERMS, are discussed in this report. Their current generation technologies are analyzed, and their integration (or evolution) with an ADMS technology is discussed. An ADMS technology state of the art and gap analysis is also presented. There are two technical gaps observed. The integration challenge between the component operational systems is the single largest challenge for ADMS design and deployment. Another significant challenge noted is concerning essential ADMS applications, for instance, fault location, isolation, and service restoration (FLISR), volt-var optimization (VVO), etc. There are a relatively small number of ADMS application developers as ADMS software platform is not open source. There is another critical gap and while not being technical in nature (when compared the two above) is still important to consider. The data models currently residing in utility GIS systems are either incomplete or inaccurate or both. This data is essential for planning and operations because it is typically one of the primary sources from which power system model are created. To achieve the full potential of ADMS, the ability to execute acute Power Flow solution is an important pre-requisite. These critical gaps are hindering wider Utility adoption of an ADMS technology. The development of an open architecture platform can eliminate many of these barriers and also aid seamless integration of distribution Utility legacy systems with an ADMS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison Between Oil-mist and Oil-jet Lubrication of High-speed, Small-bore, Angular-contact Ball Bearings

Parametric tests were conducted with an optimized 35-mm-bore-angular-contact ball bearing on a high-speed, high-temperature bearing tester. Results from both air-oil mist lubrication and oil-jet lubrication systems used to lubricate the bearing were compared to speeds of 2.5 x 10(exp 6) DN. The maximum obtainable speed with air-oil mist lubrication is 2.5 x 10(exp 6) DN. Lower bearing temperatures and higher power losses are obtained with oil-jet lubrication than with air-oil mist lubrication. Bearing power loss is a direct function of oil flow to the bearing and independent of oil delivery system. For a given oil-flow rate, bearing temperature and power loss increase with increases in speed. Bearing life is an inverse function of temperature, the difference in temperature between the individual bearing ring components, and the resultant elastohydrodynamic (EHD) film thicknesses. Bearing life is independent of the oil delivery system except as it affects temperature. Cage slip increased with increases in speed. Cage slip as high as 7 percent was measured and was generally higher with air-oil mist lubrication than with oil-jet lubrication.

Pinel, Stanley I.↗

Aerodynamic Design and Optimization of Fan Stage for Boundary Layer Ingestion Propulsion System

The present paper addresses the process of preliminary design of a low-pressure fan and outlet guide vane (OGV) of a boundary layer ingestion (BLI) propulsion system. The tail-cone thruster systems of NASA's STARC_ABL (Single-aisle Turboelectric Aircraft with an Aft Boundary-Layer propulsor) adopts an axi-symmetric BLI type inlet as opposed to other embedded engine systems. Thus, the focus of the present work is placed on maximizing the efficiency of the fan and OGV stages under a significant radial distortion. A parameterization with B-spline function for camber line angles, metal chord, thickness distribution and stacking axis of blades is presented. The flowpath lines are also parameterized by B-spline function and aggregated in the design system of blades. The design optimization with evolutionary algorithm is performed with constraints of fan pressure ratio, OGV exit swirl angle and nozzle exit properties. The inlet conditions for the turbo-machinery CFD (Computational Fluid Dynamics) domain and the design goal of the fan stage are driven by a propulsion airframe integration (PAI) model that uses a 3-D unstructured RANS (Reynolds Average Navier Stokes) solver and actuator disk model. The expected power saving of the BLI propulsor is quantified via PAI analysis and the resulting preliminary design of the fan stages is compared with a clean-inlet flow propulsor.

Turbo-machinery↗

Techno-economic implications and cost of forecasting errors in solar PV power production using optimized deep learning models

Accurate solar Photovoltaic (PV) power forecasting is important for enhancing both the performance and economic feasibility of PV systems. This study evaluates several deep learning models, including Dense Neural Networks (DNN), Long Short-Term Memory (LSTM), Convolutional Neural Networks (CNN), and a hybrid LSTMCNN model, for predicting PV power production one day in advance. Prior to optimization, the models exhibited relatively high errors, with the best model (DNN) achieving a Root Mean Square Error (RMSE) of 31.13 kW and a coefficient of determination (R 2 ) of 62.15 %. After employing Bayesian optimization, the LSTM-CNN model demonstrated the best performance, with the RMSE reduced to 9.79 kW and R 2 improved to 97.62 %, showcasing significant enhancement in predictive accuracy. Here, the economic evaluation considered three cases: rewards for underestimation (0.08 USD/kWh), no rewards, and penalties for both over-and underestimation (120 % of the utility tariff). In the rewards scenario, the LSTM-CNN model reduced the Levelized Cost of Electricity (LCOE) by 4 %, while in the penalty scenario, a backup diesel generator would have increased the LCOE by 49 %. Additionally, the LSTM-CNN model minimized financial losses, achieving the lowest penalties and maximizing net cash flow compared to other models, demonstrating its overall technical and economic superiority.

Deep learning↗