Search NASA⌕ Search

SEARCH · Search NASA

Results for “PUMPS - SCAVENGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Energy Factor Analysis for Gas Heat Pump Water Heaters

Gas heat pump water heaters (HPWHs) can improve water heating efficiency with zero GWP and zero ODP working fluids. The energy factor (EF) of a gas HPWH is sensitive to several factors. In this work, expressions are derived for EF of gas HPWHs, as a function of heat pump cycle COP, tank heat losses, burner efficiency, electrical draw, and effectiveness of supplemental heat exchangers. The expressions are used to investigate the sensitivity of EF to each parameter. EF is evaluated on a site energy basis (as used by the US DOE for rating water heater EF), and a primary energy-basis energy factor (PEF) is also defined and included. Typical ranges of values for the six parameters are given. For gas HPWHs, using typical ranges for component performance, EF will be 59 80% of the heat pump cycle thermal COP (for example, a COP of 1.60 may result in an EF of 0.94 1.28). Most of the reduction in COP is due to burner efficiency and tank heat losses. Gas-fired HPWHs are theoretically be capable of an EF of up to 1.7 (PEF of 1.6); while an EF of 1.1 1.3 (PEF of 1.0 1.1) is expected from an early market entry.

Gluesenkamp, Kyle R↗

Experimental Evaluation of High Performance Integrated Heat Pump

Integrated heat pump (IHP) technology provides significant potential for energy savings and comfort improvement for residential buildings. In this study, we evaluate the performance of a high performance IHP that provides space heating, cooling, and water heating services. Experiments were conducted according to the ASHRAE Standard 206-2013 where 24 test conditions were identified in order to evaluate the IHP performance indices based on the airside performance. Empirical curve fits of the unit s compressor maps are used in conjunction with saturated condensing and evaporating refrigerant conditions to deduce the refrigerant mass flowrate, which, in turn was used to evaluate the refrigerant side performance as a check on the airside performance. Heat pump (compressor, fans, and controls) and water pump power were measured separately per requirements of Standard 206. The system was charged per the system manufacturer s specifications. System test results are presented for each operating mode. The overall IHP performance metrics are determined from the test results per the Standard 206 calculation procedures.

Miller, William A↗

European Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater

High efficiency gas-burning hot water heating takes advantage of a condensing heat exchanger to deliver improved combustion efficiency over a standard non-condensing configuration. The water heating is always lower than the gas heating value. In contrast, Gas Absorption Heat Pump (GAHP) hot water heating combines the efficiency of gas burning with the performance increase from a heat pump to offer significant gas energy savings. An ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. In comparison with air source electric heat pumps, the absorption system can maintain higher coefficients of performance in colder climates. In this work, a GAHP commercial water heating system was compared to a condensing gas storage system for a range of locations and climate zones across Europe. The thermodynamic performance map of a single effect ammonia-water absorption system was used in a building energy modeling software that could also incorporate the changing ambient air temperature and water mains temperature for a specific location, as well as a full-service restaurant water draw pattern.

Sharma, Vishaldeep↗

Low-Cost Control System Built Upon Consumer-Based Electronics For Supervisory Control Of A Gas-Operated Heat Pump

A preliminary evaluation of the performance of a consumer-based control system was conducted by the Oak Ridge National Laboratory (ORNL) and Southwest Gas as part of a cooperative research and development agreement (CRADA) authorized by the Department of Energy (DOE) (Mahderekal et al. (2013). The goal of the research was to evaluate the low-cost approach as a solution for implementing a supervisory control system for a residential gas-operated heat pump. The design incorporated two consumer-based micro-controllers; the Arduino Mega-2650 and the BeagleBone (white). Ten five-ton heat pump systems were designed, fabricated, and operationally tested in the Las Vega NV region. A robust data set was produced that allowed detailed assessment of the reliability and the operational perfromance of the newly developed control system. Experiences gained from the test provided important points of improvement for subsequent evolution of the heat pump technology.

Wetherington Jr, G↗

System and method of detecting cavitation in pumps

A system and method for detecting cavitation in pumps for fixed and variable supply frequency applications is disclosed. The system includes a controller having a processor programmed to repeatedly receive real-time operating current data from a motor driving a pump, generate a current frequency spectrum from the current data, and analyze current data within a pair of signature frequency bands of the current frequency spectrum. The processor is further programmed to repeatedly determine fault signatures as a function of the current data within the pair of signature frequency bands, repeatedly determine fault indices based on the fault signatures and a dynamic reference signature, compare the fault indices to a reference index, and identify a cavitation condition in a pump based on a comparison between the reference index and a current fault index.

42 ENGINEERING↗

Failure, modal, and vibration analysis of a reactor pool cooling pump

Two 75 HP pumps redundantly supply cooling water to the reactor pool of the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL). Due to a recent history of premature bearing failures, one of these pumps has undergone maintenance to deal with possible issues of misalignment and base looseness. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up and down order tracking, and modal impact have been utilized to verify the effectiveness of the maintenance and identify possible remaining failure modes. The studies conclude that the pump is, after the maintenance, in an overall good conditional state as per ISO 10816, but a few failure modes remain. These modes consist of some shaft unbalance, considerable shaft misalignment intensified by piping movement, possible motor ground fault, hydrodynamic issues such as cavitation with modal interaction, and base looseness. These failure modes and their supporting data have been used to make suggestions for future maintenance, to verify the effectiveness of the previous maintenance, and to provide a base on which to check future data. This report will cover the testing setup, methodology, analysis results, and maintenance suggestions.

42 ENGINEERING↗

Direct diode pumped Ti:sapphire lasers and amplifiers

Direct diode-pumped Ti:sapphire laser amplifiers use fiber-coupled laser diodes as pump beam sources. The pump beam may be polarized or non-polarized. Light at wavelengths below 527 nm may be used in cryogenic configurations. Multiple diode outputs may be polarization or spectrally combined.

Kirchner, Matthew S.↗

Magnetically controlled valve and pump devices and methods of using the same

Disclosed herein are embodiments of magnetically controlled valve and pump systems that can be used to control and facilitate fluid flow in fluidic devices. Various types of magnetically controlled valves and pumps are described as well as methods of magnetically-controlling such valves and pumps.

42 ENGINEERING↗

Sodium Pumping via Condensation within a Non-Wetting Porous Structure

The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is required to complete the thermodynamic cycle of a sodium thermal electrochemical converter (Na-TEC). A unique capillary pump is explored in this work, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > pi/2) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Conjugate heat transfer techniques are used to model the coupled momentum and thermal transport processes within this non-wetting porous structure. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for the non-isothermal, compressible vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is also considered for situations where there is a substantial presence of non-condensable argon in the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. The main design features of an experimental set-up used to demonstrate this capillary pumping is also described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. Finally, several of the challenges with this experiment will be discussed, and specific strategies used to address these are presented.

14 SOLAR ENERGY↗

Systems and devices for pumping and controlling high temperature fluids

The disclosed technology includes pumps, pipes, valves, seals, and systems for pumping and controlling high temperature fluids, such as liquid tin, at temperatures of between 1000-3000° C. The systems and device may be partially or entirely constructed using brittle materials, such as ceramics, that are capable of withstanding extreme heat without significantly degrading, and may be secured using components made of refractory metals, such as tungsten. The systems and devices may utilize static and dynamic seals made from brittle materials, such as graphite, to enable the high temperature operation of such pumps, pipes, valves, and systems without leakage.

Henry, Asegun↗

Ultrafast, multiphoton-pump, multiphoton-probe spectroscopy

Methods for pump-probe spectroscopy are provided. In an embodiment, such a method comprises directing pump light having a frequency ωpump at a location in a sample to excite a transition between two quantum states of a target entity in the sample, directing probe light at the location to generate a coherent output signal having a frequency ωoutput and a wavevector koutput, and detecting the output signal as the probe light is scanned over a range of frequencies. In the method, either the transition excited by the pump light is a multiphoton transition corresponding to a frequency difference of n*ωpump, wherein n≥2; or the probe light is a set of m coherent light pulses, each coherent light pulse having a frequency ωm and a wavevector km, wherein m≥2; or both. Systems for carrying out the methods are also provided.

Morrow, Darien James↗

Residential Split Heat Pump Using Low GWP Refrigerants

Conventional refrigerants, e.g. R-410A have high global warming potentials (GWP) > 1800. They are being phased out to protect the environment. The candidates to replace R-410A include R-32, R-452B, R-454B and R-466A for heat pump applications. These candidates are intended for drop-in replacement, i.e. having minimum modifications on existing systems. The paper investigates the low GWP refrigerants drop-in application via system simulations using a well-regarded, hardware-based heat pump model. A baseline heat pump having all fin-and-tube heat exchangers and a two-speed compressor was used. Cross-comparisons were made under rated conditions of ambient temperatures, compressor speeds, indoor air flow rates, respectively for cooling and heating operations. The seasonal performance indices, i.e. SEER and HSPF are presented.

Shen, Bo↗

Residential Cold-Climate Heat Pump Technology Challenge

Cold-climate heat pumps (CCHPs) provide both space heating and cooling for homes, and incorporate advanced features that allow for improved heating capacity and efficiency at cold weather conditions compared with traditional heat pumps. To advance the adoption of CCHP technologies, DOE is launching the Cold-Climate Heat Pump Technology Challenge as part of the Initiative for Better Energy, Emissions, and Equity (E3 Initiative).

Space conditioning, water heating, HVAC, competiti↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

Model-based Co-Simulation of Heat Pump Water Heater with Phase Change Materials Thermal Energy Storage

The study analysis the behavior of a new developed heat pump water heater technology which integrates a phase change materials storage with a standard heat pump water heater to maximize the performance parameters of the Unified Energy Factor (UEF) and First Hour Rating (FHR). A model-based control development co-simulation platform is developed to include equipment models, such as heat pump, standard water tank, phase change materials storage tank, and integrate them with control model to support controls design, analysis, verification, and validation. Simulation results are compared with lab test results to validate the accuracy of developed co-simulation platform

Sun, Jian↗

Initial Design and Experimental Results of a Novel Near-Isothermal Compressor for Heat Pump Applications

In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.

Kowalski, Steve↗

Counter pumping a large mode area fiber laser

A fiber optic assembly includes: a gain fiber configured to output signal light; a first taper configured to expand the signal light output by the gain fiber; and a reversing prism configured to receive counter-pumping light and output the counter-pumping light into the first taper. The first taper is further configured to direct the counter-pumping light towards the gain fiber.

Sipes, Jr., Donald Lee↗