Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Analysis of nonlinear optical propagation in a longitudinal deuterated potassium dihydrogen phosphate Pockels cell

Nonlinear optical propagation in a longitudinal deuterated potassium dihydrogen phosphate (DKDP) Pockels cell (PC) is studied analytically and with numerical simulations. Propagation equations are developed taking into account the nonlinear susceptibility tensor and the modification of the polarization state because of the voltageinduced birefringence of the Pockels cell. The analytical predictions are in good agreement with split-step simulations. The nonlinear polarization in the PC’s crystalline medium leads to nonlinear phase shifts and crossed-wave generation. For the small nonlinearities consistent with typical operation in a laser system, a quarter-wave PC induces a nonlinear phase equal to the average of the nonlinear phase accumulated by a linearly and circularly polarized field of the same intensity propagating in the inactive PC. The contrast of a half-wave PC between crossed polarizers is not decreased by the nonlinear propagation because there is no generated cross wave in this configuration.

Electro-optical devices↗

Connection and validation of narrow-band delta VLBI phase observations

Narrow-band differential very long baseline interferometry required phase connections between consecutive scans. An efficient computer aided scheme for this purpose is presented. This scheme is an iteration process alternating between a grand fit on many scans and integer quantization of the phase shift cycles to be assigned to the scans. Only linear simultaneous equations of a few unknowns need to be solved. A simulation analysis indicates that faultless phase connection can be expected when there is no localized systematic noise. When systematic noise of moderate level exists, the possible incorrect phase connection can be detected and connected for by comparing the connected phases from the two alternating observations, after removing the residual diurnal effects.

Wu, S. C.↗

Equations of motion for a free-electron laser with an electromagnetic pump field and an axial electrostatic field

The equations of motion for a free-electron laser (FEL) with an electromagnetic pump field and a static axial electric field are derived using a Hamiltonian formalism. Equations governing the energy transfer between the electron beam and each of the electromagnetic fields are given, and the phase shift for each of the electromagnetic fields is derived from a linearized Maxwell wave equation. The relation between the static axial electric field and the resonant phase is given. Laser gain and the fraction of the electron energy converted to photon energy are determined using a simplified resonant particle model. These results are compared to those of a more exact particle simulation code.

Hiddleston, H. R.↗

Four-to-one power combiner for 20 GHz phased array antenna using RADC MMIC phase shifters

The design and microwave simulation of two-to-one microstrip power combiners is described. The power combiners were designed for use in a four element phase array receive antenna subarray at 20 GHz. Four test circuits are described which were designed to enable testing of the power combiner and the four element phased array antenna. Test Circuit 1 enables measurement of the two-to-one power combiner. Test Circuit 2 enables measurement of the four-to-one power combiner. Test Circuit 3 enables measurement of a four element antenna array without phase shifting MMIC's in order to characterize the power combiner with the antenna patch-to-microstrip coaxial feedthroughs. Test circuit 4 is the four element phased array antenna including the RADC MMIC phase shifters and appropriate interconnects to provide bias voltages and control phase bits.

Source record↗

Picometer Differential Wavefront Metrology by Nonlinear Zernike Wavefront Sensing for LUVOIR

We propose the Nonlinear Zernike wavefront sensor (NLZWFS) for out-of-band differential wavefront sensing to augment primary mirror stability on LUVOIR and similar mission concepts during exoplanet coronagraphy. This new data analysis paradigm involving a full polychromatic scalar physical optics model for the phase-shifting Zernike wavefront sensor removes the linearity assumptions which would otherwise prevent accurate sensing. We show Monte-Carlo simulations of NLZWFS and focus-diverse phase retrieval to understand the exposure times necessary to achieve picometer-level stability in the telescope wavefront.

Redding, David C.↗

Analysis of double stub tuner control stability in a phased array antenna with strong cross-coupling

Active stub tuning with a fast ferrite tuner (FFT) has greatly increased the ability of fusion ion cyclotron range of frequency (ICRF) systems (50–100 MHz) by allowing for the antenna system to respond dynamically to changes in the plasma load impedance such as during the L–H transition or edge localized modes (ELMs). A high power waveguide double-stub tuner is under development for use with the Alcator C-Mod lower hybrid current drive (LHCD) system at 4.6 GHz. The amplitude and relative phase shift between adjacent columns of an LHCD antenna are critical for control of the launched n || spectrum. Adding a double-stub tuning network will perturb the phase and amplitude of the forward wave particularly if the unmatched reflection coefficient is high. This effect can be compensated by adjusting the phase of the low power microwave drive for each klystron amplifier. Cross-coupling of the reflected power between columns of the launcher must also be considered. The problem is simulated by cascading a scattering matrix for the plasma provided by a linear coupling model with the measured launcher scattering matrix and that of the FFTs. The solution is advanced in an iterative manner similar to the time-dependent behavior of the real system. System performance is presented under a range of edge density conditions from under-dense to over-dense and a range of launched n || . Simulations suggest power reflection coefficients (Γ 2 ) of less than 1% with no contamination of the n || spectrum. Instability of the FFT tuning network can be difficult for certain plasma conditions and relative phasings, but reducing the control gain of the FFT network stabilizes the system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast high-power microwave ferroelectric phase shifters for accelerator application

Measurements are reported for a one-third version of a high-power L-band ferroelectric phase shifter. This phase shifter is designed to allow rapid adjustments of cavity coupling in an accelerator where RF source fluctuations, microphonics, or othe r uncontrolled fluctuations could cause undesired emittance growth. Experimental measurements of phase shift vs externally-applied voltage, insertion loss, and switching speed are presented. An average switching rate of less than 0.5 ns for each degree of RF phase has been measured.

43 PARTICLE ACCELERATORS↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

SAS-2 gamma-ray observations of PSR 1747-46

Observations with the SAS-2 high energy ( 35 MeV) gamma-ray telescope show evidence of gamma-ray emission from the radio pulsar PSR 1747-46. When the arrival times of gamma-rays from the region of the pulsar were converted to pulsar phases using the radio period and period derivative, a single peak was found in the phase plot, with a Poisson probability of occurring by chance of .00008. Independently, the time-averaged data for the PSR 1747-46 region show an enhancement over the surrounding region of the sky at the same galactic latitude, with a Poisson probability of chance occurrence of less than .008. The probability that these results are chance is the product of these two probabilities times the number of radio pulsars examined (73). This overall probability is sufficiently small (.00005) to suggest an identification of a new gamma-ray pulsar. In the gamma-ray pulsar plot, the peak falls 0.16 + or - 0.03 period after the radio pulsar peak. This phase shift is, within uncertainties, the same as that observed between the single radio peak and the first of the two gamma-ray peaks seen in the phase plot for PSR-0833-45 (the Vela pulsar).

Thompson, D. J.↗

Analysis of double stub tuner control stability in a many element phased array antenna with strong cross-coupling

Active stub tuning with a fast ferrite tuner (FFT) allows for the system to respond dynamically to changes in the plasma impedance such as during the L-H transition or edge localized modes (ELMs), and has greatly increased the effectiveness of fusion ion cyclotron range of frequency systems. A high power waveguide double-stub tuner is under development for use with the Alcator C-Mod lower hybrid current drive (LHCD) system. Exact impedance matching with a double-stub is possible for a single radiating element under most load conditions, with the reflection coefficient reduced from Γ to Γ{sup 2} in the “forbidden region.” The relative phase shift between adjacent columns of a LHCD antenna is critical for control of the launched n{sub ∥} spectrum. Adding a double-stub tuning network will perturb the phase of the forward wave particularly if the unmatched reflection coefficient is high. This effect can be compensated by adjusting the phase of the low power microwave drive for each klystron amplifier. Cross-coupling of the reflected power between columns of the launcher must also be considered. The problem is simulated by cascading a scattering matrix for the plasma provided by a linear coupling model with the measured launcher scattering matrix and that of the FFTs. The solution is advanced in an iterative manner similar to the time-dependent behavior of the real system. System performance is presented under a range of edge density conditions from under-dense to over-dense and a range of launched n{sub ∥}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An analytic solution for the response of the neutral atmosphere to the high-latitude convection pattern

The analytic solutions to a two-dimensional, shallow-water model of the high-latitude thermosphere are developed. The equations are a linearized representation of the response of the neutral atmosphere to the momentum source due to the plasma convection pattern. The obtained results show how the neutral winds depend on the Pedersen and Hall ion drag coefficients and the horizontal wave number. The response depends on the dimensionless scale as it appears in the product of the Rossby radius of deformation and the wave number. The flow pattern is shifted in local time from the plasma flow pattern by an amount that depends on the average electron density. At the largest scales there is a 180 deg phase shift between the rotational flow components in the E and F regions. The model applies to quiet magnetic conditions and below 200 km of altitude.

Mikkelsen, I. S.↗

Submillimeter diagnostics of the response of the solar chromosphere to compressional waves

The NASA Infrared Telescope Facility has been used to observe local continuum brightness variations of the quiet sun in 350 and 800 micron radiation simultaneously. Variations of order 5 K are found at both wavelengths, with a strong correlation between the two. The 800 micron variations lag behind the 350 micron variations by 25-35 deg in phase. This is similar to unexpected phase shifts reported by Lites and Chipman in 1979 and Lites, Chipman, and White in 1982 between velocity and intensity for certain chromospheric lines. It is proposed that the phase lags observed are the result of nonadiabatic response of the chromosphere to compression, which could be an important mechanism for dissipation of mechanical energy.

Lindsey, C.↗

Crystallization of Chicken Egg White Lysozyme from Sulfate Salts

It has been "known" that chicken egg white lysozyme does not crystallize from sulfate, particularly ammonium sulfate, salts, but instead gives amorphous precipitates. This has been the basis of several studies using lysozyme comparing macromolecule crystal nucleation and amorphous precipitation. Recently Ries-Kautt et al (Acta Cryst D50, (1994) 366) have shown that purified isoionic CEWL could be crystallized from low concentrations of sulfate at basic pH, and we subsequently showed that in fact CEWL could be purified in both the tetragonal and orthorhombic forms using ammonium sulfate over the pH range 4.0 to 7.8 (Acta Cryst D53, (1997) 795). We have now extended these observations to include a range of common sulfate salts, specifically sodium, potassium, rubidium, magnesium, and manganese sulfates. In all cases but the manganese sulfates both the familiar tetragonal and orthorhombic forms were obtained, with unit cell dimensions close to those known for the "classic" sodium chloride crystallized forms. Manganese sulfate has only yielded orthorhombic crystals to date. All crystallizations were carried out using low (typically less than or equal to 6 M) salt and high (greater than approximately 90 mg/ml) protein concentrations. As with ammonium sulfate, the tetragonal - orthorhombic phase shift appears to be a function of both the temperature and the protein concentration, with higher temperatures and concentrations favoring the orthorhombic and lower the tetragonal form. The phase change range is somewhat reduced for the sulfate salts, depending upon conditions being typically between approximately 15 - 20 C. Both the magnesium and manganese sulfates gave crystals at salt concentrations over 0.6 M as well, with magnesium sulfate giving a very slowly nucleating and growing hexagonal form. A triclinic crystal form, characterized by aggressively small crystals (typically 0.1 mm in size) has been occasionally obtained from ammonium sulfate. Finally, preliminary spot solubility determinations have suggested that in some cases the solubility increases with increasing salt concentrations.

Forsythe, Elizabeth↗

An Agile Beam Transmit Array Using Coupled Oscillator Phase Control

A few years ago York and colleagues suggested that injection locking of voltage controlled oscillators could be used to implement beam steering in a phased array [I]. The scheme makes use of the fact that when an oscillator is injection locked to an external signal, the phase difference between the output of the oscillator and the injection signal is governed by the difference between the injection frequency and the free running frequency of the oscillator (the frequency to which the oscillator is tuned). Thus, if voltage controlled oscillators (VCOs) are used, this phase difference is controlled by an applied voltage. Now, if a set of such oscillators are coupled to nearest neighbors, they can be made to mutually injection lock and oscillate as an ensemble. If they are all tuned to the same frequency, they will all oscillate in phase. Thus, if the outputs are connected to radiating elements forming a linear array, the antenna will radiate normal to the line of elements. Scanning is accomplished by antisymmetrically detuning the end oscillators in the array by application of a pair of appropriate voltages to their tuning ports. This results in a linear phase progression across the array which is just the phasing required to scan the beam. The scan angle is determined by the degree of detuning. We have constructed a seven element one dimensional agile beam array at S-band based on the above principle. Although, a few such arrays have been built in the past, this array possesses two unique features. First, the VCO MMICs have buffer amplifiers which isolate the output from the tuning circuit, and second, the oscillators are weakly coupled to each other at their resonant circuits rather than their outputs. This results in a convenient isolation between the oscillator array design and the radiating aperture design. An important parameter in the design is the so called coupling phase which determines the phase shift of the signals passing from one oscillator to its neighbors. Using this array, we have been able to verify the theoretical predictions concerning the effect of this phase on both the locking range and ensemble frequency of the array. However, the scan range achieved fell somewhat short of the theoretical value because of the amplitude variation of the oscillator outputs with tuning.

Pogorzelski, Ronald S.↗

Fluid Shifts: Otoacoustical Emission Changes in Response to Posture and Lower Body Negative Pressure

INTRODUCTION: The purpose of the NASA Fluid Shifts Study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight and to correlate these findings with vision changes and other elements of the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. Due to the invasive nature of direct measures of ICP, a noninvasive technique of monitoring ICP is desired for use during spaceflight. The phase angle and amplitude of otoacoustic emissions (OAEs) have been shown to be sensitive to posture change and ICP (1, 2), therefore use of OAEs is an attractive option. OAEs are low-level sounds produced by the sensory cells of the cochlea in response to auditory stimulation. These sounds travel peripherally from the cochlea, through the oval window, to the ear canal where they can be recorded. OAE transmission is sensitive to changes in the stiffness of the oval window, occurring as a result of changes in cochlear pressure. Increased stiffness of the oval window largely affects the transmission of sound from the cochlea at frequencies between 800 Hz and 1600 Hz. OAEs can be self-recorded in the laboratory or on the ISS using a handheld device. Our primary objectives regarding OAE measures in this experiment were to 1) validate this method during preflight testing of each crewmember (while sitting, supine and in head-down tilt position), and 2) determine if OAE measures (and presumably ICP) are responsive to lower body negative pressure and to spaceflight. METHODS: Distortion-product otoacoustic emissions (DPOAEs) and transient evoked otoacoustic emissions (TEOAEs) were recorded preflight using the Otoport Advance OAE system (Otodynamics Ltd., Hatfield, UK). Data were collected in four conditions (seated, supine, 15 degrees head down tilt (HDT), and 15 degrees HDT with lower body negative pressure (LBNP)) to produce a range of ICP in each subject and test the susceptibility of OAEs to LBNP. LBNP was induced using the Russian Chibis suit to produce the same fit and pressures that would be experienced inflight during Chibis LBNP trials. Similar trials have occurred inflight on the ISS. A comparative analysis of preflight and inflight phase measurements and magnitudes was completed in both broad and narrow band frequency ranges. RESULTS: TEOAE data demonstrated notable phase shifts from 859-1640 Hz when the seated baseline condition is compared to supine, HDT, and HDT plus Chibis conditions. Changes were particularly pronounced at low frequencies and were consistent with the expected ICP changes. Preflight DPOAE magnitude data revealed changes consistent with increased ICP in two conditions at 1414 Hz, where a magnitude change (relative to the seated condition) was seen in the HDT position and in HDT plus Chibis. DISCUSSION: OAEs revealed systematic changes in phase and magnitude throughout all test conditions (including use of Chibis LBNP) that were consistent with ICP changes. Results indicate that OAEs may provide a rapid noninvasive means of monitoring ICP changes. The first two subjects are projected to complete inflight testing on the ISS in early 2016, with the full complement of 10 subjects scheduled to be complete in 2018.

Melgoza, R.↗

Cross-Array Antenna With Switched Steering

Selected phase shifting of feeds to antenna elements aims antenna beam. Antenna for Space Shuttle controlled in two dimensions by double-pole, double-throw switches antenna feeds. Switches control phasing of antenna elements by transposing transmission-line delay elements between feeds to pairs of elements located on opposite sides of antenna. Same principles can be applied to antennas with additional elements along each axis.

Iwasaki, R. S.↗

Variations in Sleep and Performance by Duty Start Time in Short Haul Operations

Prior studies have confirmed that commercial airline pilots experience circadian phase shifts and short sleep duration following travel with layovers in different time zones. Few studies have examined the impact of early and late starts on the sleep and circadian phase of airline pilots who return to their domicile after each duty period. We recruited 44 pilots (4 female) from a short-haul commercial airline to participate in a study examining sleep and circadian phase over four duty schedules (baseline, early starts, mid-day starts, late starts). Each duty schedule was five days long, separated by three rest days. Participants completed the rosters in the same order. Sleep outcomes were estimated using wrist-borne actigraphy (Actiware Software, Respironics, Bend, OR) and daily sleep diaries. Thirteen participants volunteered to collect urine samples for the assessment of 6-sulfatoxymelatonin (aMT6s). Urine samples were collected in four-hourly bins during the day and eight-hourly bins during sleep episodes, for 24 hours immediately following each experimental duty schedule. The aMT6s results were fit to a cosine in order to obtain the acrophase to estimate circadian phase. Univariate statistics were calculated for acrophase changes, schedule start times and sleep times. All statistical analyses were computed using SAS software (Cary, IN).

fatigue↗

Scanning Tunneling Microscopy Observation of Phonon Condensate

Using quantum tunneling of electrons into vibrating surface atoms, phonon oscillations can be observed on the atomic scale. Phonon interference patterns with unusually large signal amplitudes have been revealed by scanning tunneling microscopy in intercalated van der Waals heterostructures. Our results show that the effective radius of these phonon quasi-bound states, the real-space distribution of phonon standing wave amplitudes, the scattering phase shifts, and the nonlinear intermode coupling strongly depend on the presence of defect-induced scattering resonance. The observed coherence of these quasi-bound states most likely arises from phase- and frequency-synchronized dynamics of all phonon modes, and indicates the formation of many-body condensate of optical phonons around resonant defects. We found that increasing the strength of the scattering resonance causes the increase of the condensate droplet radius without affecting the condensate fraction inside it. The condensate can be observed at room temperature.

36 MATERIALS SCIENCE↗