Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Life-Cycle Analysis of Residential Windows Retrofits: Net GHG Emission Reduction and Payback Periods

Windows are a critical envelope component that plays an important role in the overall performance and environmental impact of a building life cycle. These implications can be embedded in the window lifecycle related to its design, manufacturing, raw materials and transportation, performance during the building’s use (operational), replacements, maintenance and end-of-life. Windows may impact 25% of the heating and cooling energy use, 10% of total building energy use and 45% of the envelope heat transfer (Harris 2022). The impacts of windows on the energy consumption of buildings have been extensively discussed, however, its embodied life-cycle impacts, such as greenhouse gas (GHG) emissions, and the trade-offs between the embodied and its operational emissions are less explored. Understanding the life cycle impacts of windows may subsidize decision making process and inform the development of emerging windows technologies. BTO’s Windows Program has played an important role to increase the adoption of emerging technologies as high-performance windows in the U.S. (Harris 2022) and to consider the GHG emission impacts of the those windows is an important aspect that can support the strategic objectives and the performance targets from the national blueprint for decarbonizing the buildings sector and to reduce the on-site emissions and embodied life cycle emissions from building materials and construction (US DOE 2024).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive lighting for streets and residential areas

Adaptive lighting is an approach to lighting application in which the lighting levels are controlled based on the needs of the users of the lighted environment. Such systems are enabled by the instant-on and dimming capabilities of solid-state lighting and have been shown to have the potential to reduce energy consumption by over 50%, both through the use of maintained lighting levels without over-lighting and dimming. This investigation considered the impact of adaptive lighting within Cambridge NA. The impact of adaptive lighting on crashes and crime was considered using both the timing of the installation of the LED system in a before-and-after comparison, as well as a comparison to a neighboring non-dimming city. Industry practitioners and the public were also surveyed. As a follow-on to the first analysis, a human factors experiment was performed to investigate if the lighting levels could be further refined to improve energy performance. Overall, the energy savings from the dimming system range from 55% initially to 36% at the end of the life of the luminaire system

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Cost Identification and Monitoring of Diverse MELs in Residential and Commercial Buildings with PowerBlade (Final Technical Report)

This report describes our progress in developing a scalable wireless metering system that integrates plug-load energy meters that measure real, reactive, and apparent power along with load monitoring based on extracting high-fidelity electrical waveform features collected at every load to capture power profiles and automatically identify and categorize MELs, and make this technology available to the research, commercial, and government sectors.

47 OTHER INSTRUMENTATION↗

Residential Electrification Roadmapping - Technical and Messaging Review (CRADA Final Report)

This work is to be conducted in support of the American Made Challenges EAS-E Prize. The intent is to connect competitor teams with national laboratories that can help accelerate the development of innovative solutions and products. National Renewable Energy Laboratory (NREL) and Pacific Northwest National Laboratory (PNNL) will help accelerate QuitCarbon’s automated home electrification planning model development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solvari SR, Simplifying Residential Solar to 1 SKU, with Extended Testing

Accelerated weathering and material compatibility testing for polymeric and asphaltic materials. NLR will be testing the durability of the polymeric materials proposed for use in the supporting structures designed by TESCI solar. This will include the bare materials and coupons attached to asphalt shingles. The exposure will be in damp heat and separately heat, humidity and UV light, all followed by mechanical evaluation. Modification 1 is an extension of the first round of testing with both a continuation of some of the same testing and addition of new testing methods and materials. The testing of materials in the condition of A3 looking at mechanical durability will be continued looking at the materials used in the mounting brackets. We will be adding in testing of the silicone adhesive to the module and of the module itself. For the mounting brackets, testing will also be conducted at multiple temperatures and humidity levels to allow for extrapolation to the field.

14 SOLAR ENERGY↗

Defining Power Efficient Residential Electric Appliances and Equipment

While the long-established concept of "energy efficiency" has successfully reduced energy consumption and bills in homes, it is no longer sufficient to address the modern challenges of electrical load growth, infrastructure upgrades and associated affordability challenges. We introduce the concept of “power efficiency” for household appliances and equipment, providing a framework to support affordable home modernization and grid management. Energy efficiency is the measure of energy used (kWh) to provide comfort/conveniences, power efficiency is the measure of power used (kW) to provide those same comforts/conveniences. Energy efficiency was needed because energy is a limited resource and expensive. Now power efficiency is needed because power delivery into a building is a limited resource and expensive. We propose a new set of metrics for defining and measuring power efficiency by investigating how current appliance nameplate ratings are established, and assessing the availability and use of existing data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test Protocol for Room-to-Room Distribution of Outside Air by Residential Ventilation Systems

This test and analysis protocol has been developed as a practical approach for measuring outside air distribution in homes. It has been used successfully in field tests and has led to significant insights on ventilation design issues. Performance advantages of more sophisticated ventilation systems over simpler, less-costly designs have been verified, and specific problems, such as airflow short-circuiting, have been identified.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating Demand Response Load Impacts: Evaluation of BaselineLoad Models for Non-Residential Buildings in California

Both Federal and California state policymakers areincreasingly interested in developing more standardized and consistentapproaches to estimate and verify the load impacts of demand responseprograms and dynamic pricing tariffs. This study describes a statisticalanalysis of the performance of different models used to calculate thebaseline electric load for commercial buildings participating in ademand-response (DR) program, with emphasis onthe importance of weathereffects. During a DR event, a variety of adjustments may be made tobuilding operation, with the goal of reducing the building peak electricload. In order to determine the actual peak load reduction, an estimateof what the load would have been on the day of the event without any DRactions is needed. This baseline load profile (BLP) is key to accuratelyassessing the load impacts from event-based DR programs and may alsoimpact payment settlements for certain types of DR programs. We testedseven baseline models on a sample of 33 buildings located in California.These models can be loosely categorized into two groups: (1) averagingmethods, which use some linear combination of hourly load values fromprevious days to predict the load on the event, and (2) explicit weathermodels, which use a formula based on local hourly temperature to predictthe load. The models were tested both with and without morningadjustments, which use data from the day of the event to adjust theestimated BLP up or down.Key findings from this study are: - The accuracyof the BLP model currently used by California utilities to estimate loadreductions in several DR programs (i.e., hourly usage in highest 3 out of10 previous days) could be improved substantially if a morning adjustmentfactor were applied for weather-sensitive commercial and institutionalbuildings. - Applying a morning adjustment factor significantly reducesthe bias and improves the accuracy of all BLP models examined in oursample of buildings. - For buildings with low load variability, all BLPmodels perform reasonably well in accuracy. - For customer accounts withhighly variable loads, we found that no BLP model produced satisfactoryresults, although averaging methods perform best in accuracy (but notbias). These types of customers are difficult to characterize withstandard BLP models that rely on historic loads and weather data.Implications of these results for DR program administrators andpolicymakersare: - Most DR programs apply similar DR BLP methods tocommercial and industrial sector customers. The results of our study whencombined with other recent studies (Quantum 2004 and 2006, Buege et al.,2006) suggests that DR program administrators should have flexibility andmultiple options for suggesting the most appropriate BLP method forspecific types of customers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Experimental and Analytical Evaluation of Wall And Window Retrofit Configurations: Supporting the Residential Retrofit Best Practices Guide

A Retrofit Best Practices Guide was developed to encourage homeowners to consider energy conservation issues whenever they modify their siding or windows. In support of this guide, an experimental program was implemented to measure the performance of a number of possible wall siding and window retrofit configurations. Both thermal and air-leakage measurements were made for a 2.4 x 2.4 m (8 x 8 ft) wall section with and without a 0.9 x 1.2 m (3 x 4 ft) window. The windows tested were previously well-characterized at a dedicated window test facility. A computer model was also used to provide information for the Best Practices Guide. The experimental data for walls and windows were used in conjunction with this model to estimate the total annual energy savings for several typical houses in a number of different locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RESIDENTIAL THERMOSTATS: COMFORT CONTROLS IN CALIFORNIA HOMES

This report summarizes results of a literature review, a workshop, and many meetings with demand response and thermostat researchers and implementers. The information obtained from these resources was used to identify key issues of thermostat performance from both energy savings and peak demand perspectives. A research plan was developed to address these issues and activities have already begun to pursue the research agenda.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NATURAL GAS VARIABILITY IN CALIFORNIA: ENVIRONMENTAL IMPACTS AND DEVICE PERFORMANCE EXPERIMENTAL EVALUATION OF POLLUTANT EMISSIONS FROM RESIDENTIAL APPLIANCES

The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. The baseline fuel was Northern California line gas with Wobbe number (a measure of fuel energy delivery rate) of 1320-1340; test fuels had Wobbe numbers of roughly 1390 and 1420, and in some cases 1360. No ignition or operational problems were observed during test fuel use. Baseline emissions varied widely across and within burner groups and with burner operational mode. Statistically significant emissions changes were observed for some pollutants on some burners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved Design of Motors for Increased Efficiency in Residential Commercial Buildings

Research progress on understanding magnetic steel core losses is presented in this report. Three major aspects have been thoroughly investigated: 1, experimental characterization of core losses, 2, fundamental physical understanding of core losses and development of core loss formulas, and 3, design of more efficient machine based on the new formulations. Considerable progress has been achieved during the four years of research and the main achievements are summarized in the following: For the experimental characterization, a specially designed advanced commercial test bench was commissioned in addition to the development of a laboratory system with advanced capabilities. The measured properties are core losses at low and higher frequencies, with sinusoidal and non-sinusoidal excitations, at different temperatures, with different measurement apparatus (Toroids, Epstein etc). An engineering-based core loss formula has been developed which considers skin effect. The formula can predict core losses for both sinusoidal and non-sinusoidal flux densities and frequencies up to 4000 Hz. The formula is further tested in electric machines. The formula error range is 1.1% - 7.6% while the standard formulas can have % errors between -8.5% {-+} 44.7%. Two general core loss formulas, valid for different frequencies and thickness, have been developed by analytically and numerically solving Maxwell's equations based on a physical investigation of the dynamic hysteresis effects of magnetic materials. To our knowledge, they are the first models that can offer accurate core loss prediction over a wide range of operating frequencies and lamination thicknesses without a massive experimental database of core losses. The engineering core loss formula has been used with commercial software. The formula performs better than the modified Steinmetz and Bertotti's model used in Cedrat/Magsoft Flux 2D/3D. The new formula shows good correlation with measured results under both sinusoidal and non-sinusoidal excitations. A permanent magnet synchronous motor has been designed with the use of the engineering formula with Flux2D. There was acceptable agreement between predictions and measurements. This was further tested on an induction motor with toroid results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Residential GSHP System

This report first briefly reviews geothermal heat pump (GHP) technology and the current status of the GHP industry in the United States. Then it assesses the potential national benefits, in terms of energy savings, reduced summer peak electrical demand, consumer energy cost savings, and reduced CO{sub 2} emissions from retrofitting the space heating, space cooling, and water heating systems in existing U.S. single-family homes with state-of-the-art GHP systems. The investment for retrofitting typical U.S. single-family homes with state-of-the-art GHP systems is also analyzed using the metrics of net present value and levelized cost.

15 GEOTHERMAL ENERGY↗