Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Transport Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Radial diffusion models of energetic electrons and Jupiter's synchrotron radiation. 2: Time variability

We used a radial diffusion code for energetic electrons in Jupiter's magnetosphere to investigate variations in Jupiter's radio emission due to changes in the electron phase space density at L shells between 6 and 50, and due to changes in the radial diffusion parameters. We suggest that the observed variations in Jupiter's radio emission are likely caused by changes in the electron phase space density at some boundary L(sub 1) is greater than 6, if the primary mode of transport of energetic electrons is radial diffusion driven by fluctuating electric and/or magnetic fields induced by upper atmospheric turbulence. We noticed an excellent empirical correlation, both in phase and relative amplitude, between changes in the solar wind ram pressure and Jupiter's synchrotron radiation if the electron phase space density at the boundary L(sub 1) (L(sub 1) is approximately equal to 20-50) varies linearly with the square root of the solar wind ram pressure, f is approximately (N(sub s)nu(exp 2 sub s))(exp 1/2). The calculations were carried out with a diffusion coefficient D(sub LL) = D(sub n)L(exp n) with n = 3. The diffusion coefficient which best fit the observed variations in Jupiter's synchrotron radiation D(sub 3) = 1.3 +/- 0.2 x 10(exp -9)/s is approximately 0.041/yr, which corresponds to a lagtime of approximately 2 years. We further show that the observed short term (days-weeks) variations in Jupiter's radio emission cannot be explained adequately when radial diffusion is taken into account.

De Pater, Imke↗

Generation of a novel phase-space-based cylindrical dose kernel for IMRT optimization

Purpose: Improving dose calculation accuracy is crucial in intensity-modulated radiation therapy (IMRT). We have developed a method for generating a phase-space-based dose kernel for IMRT planning of lung cancer patients. Methods: Particle transport in the linear accelerator treatment head of a 21EX, 6 MV photon beam (Varian Medical Systems, Palo Alto, CA) was simulated using the EGSnrc/BEAMnrc code system. The phase space information was recorded under the secondary jaws. Each particle in the phase space file was associated with a beamlet whose index was calculated and saved in the particle's LATCH variable. The DOSXYZnrc code was modified to accumulate the energy deposited by each particle based on its beamlet index. Furthermore, the central axis of each beamlet was calculated from the orientation of all the particles in this beamlet. A cylinder was then defined around the central axis so that only the energy deposited within the cylinder was counted. A look-up table was established for each cylinder during the tallying process. The efficiency and accuracy of the cylindrical beamlet energy deposition approach was evaluated using a treatment plan developed on a simulated lung phantom. Results: Profile and percentage depth doses computed in a water phantom for an open, square field size were within 1.5% of measurements. Dose optimized with the cylindrical dose kernel was found to be within 0.6% of that computed with the nontruncated 3D kernel. The cylindrical truncation reduced optimization time by approximately 80%. Conclusions: A method for generating a phase-space-based dose kernel, using a truncated cylinder for scoring dose, in beamlet-based optimization of lung treatment planning was developed and found to be in good agreement with the standard, nontruncated scoring approach. Compared to previous techniques, our method significantly reduces computational time and memory requirements, which may be useful for Monte-Carlo-based 4D IMRT or IMAT treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advancements in NEAMS Tool Capabilities for Multiphysics Simulation of Fast Reactor Core Bowing and Identification of Validation Test Data

Under the U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program, an integrated multiphysics approach is being developed to model the core bowing phenomena important to liquid metal-cooled fast reactors. Core bowing is an important passive safety mechanism in liquid metal-cooled fast reactors and involves Multiphysics effects including radiation transport, fluid flow, heat transfer, and mechanical response to temperature and flux gradients. This report summarizes recent progress on developing a multiphysics, MOOSE-based workflow to predict core bowing and associated reactivity feedback. Last year, thermal fluids and mechanics were coupled on a multi-assembly benchmark problem based on ABR-1000 design. This year, the reactor physics code Griffin was assessed for readiness of core bowing calculations. Preliminary integration of Griffin’s ring-heterogeneous model with thermal fluids and thermal mechanics solvers was performed. Specifically, thermal-mechanics and reactor physics were coupled for single- and multi-assembly problems, and reactor physics and subchannel methods were coupled for a single assembly model. Finally, the workflow of all three physics was preliminarily demonstrated on a single assembly model. Caveats and future development needed have been identified. To supplement the multiphysics demonstration, verification and assessment efforts of thermos-mechanical capabilities for modeling thermo-mechanical core bowing behavior were continued by analyzing IAEA Verification Problem 5 which includes radiation swelling and creep. Additionally, a small core reactor physics benchmark defined by Japan Atomic Energy Agency (JAEA) was performed to assess neutronics models for estimating reactivity feedback. Finally, Fast Flux Test Facility (FFTF) validation test data for core bowing phenomena has been identified and summarized, with a recommended path forward for validation once this capability is mature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Current generation by helicons and LH waves in modern tokamaks and reactors FNSF-AT, ITER and DEMO. Scenarios, modeling and antennae

The Innovative concept and 3D full wave code modeling Off-axis current drive by RF waves in large scale tokamaks, reactors FNSF-AT, ITER and DEMO for steady state operation with high efficiency was proposed [1] to overcome problems well known for LH method [2]. The scheme uses the helicons radiation (fast magnetosonic waves at high (20–40) IC frequency harmonics) at frequencies of 500–1000 MHz, propagating in the outer regions of the plasmas with a rotational transform. It is expected that the current generated by Helicons will help to have regimes with negative magnetic shear and internal transport barrier to ensure stability at high normalized plasma pressure β{sub N} > 3 (the so-called Advanced scenarios) of interest for FNSF and the commercial reactor. Modeling with full wave three-dimensional codes PSTELION and STELEC2 showed flexible control of the current profile in the reactor plasmas of ITER, FNSF-AT and DEMO [2,3], using multiple frequencies, the positions of the antennae and toroidal waves slow down. Also presented are the results of simulations of current generation by helicons in tokamaks DIII-D, T-15MD and JT-60SA [3]. In DEMO and Power Plant antenna is strongly simplified, being some analoge of mirrors based ECRF launcher, as will be shown. For spherical tokamaks the Helicons excitation scheme does not provide efficient Off-axis CD profile flexibility due to strong coupling of helicons with O-mode, also through the boundary conditions in low aspect machines, and intrinsic large amount of trapped electrons, as is shown by STELION modeling for the NSTX tokamak. Brief history of Helicons experimental and modeling exploration in straight plasmas, tokamaks and tokamak based fusion Reactors projects is given, including planned joint DIII-D – Kurchatov Institute experiment on helicons CD [1].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of Monte Carlo simulations for backgrounds from radioactivity

For all experiments dealing with the rare event searches (neutrino, dark matter, neutrino-less double-beta decay), the reduction of the radioactive background is one of the most important and difficult tasks. There are basically two types of background, electron recoils and nuclear recoils. The electron recoil background is mostly from the gamma rays through the radioactive decay. The nuclear recoil background is from neutrons from spontaneous fission, (α, n) reactions and muoninduced interactions (spallations, photo-nuclear and hadronic interaction). The external gammas and neutrons from the muons and laboratory environment, can be reduced by operating the detector at deep underground laboratories and by placing active or passive shield materials around the detector. The radioactivity of the detector materials also contributes to the background; in order to reduce it a careful screening campaign is mandatory to select highly radio-pure materials. In this review I present the status of current Monte Carlo simulations aimed to estimate and reproduce the background induced by gamma and neutron radioactivity of the materials and the shield of rare event search experiment. For the electromagnetic background a good level of agreement between the data and the MC simulation has been reached by the XENON100 and EDELWEISS experiments, using the GEANT4 toolkit. For the neutron background, a comparison between the yield of neutrons from spontaneous fission and (α, n) obtained with two dedicated softwares, SOURCES-4A and the one developed by Mei-Zhang-Hime, show a good overall agreement, with total yields within a factor 2 difference. The energy spectra from SOURCES-4A are in general smoother, while those from MZH presents sharp peaks. The neutron propagation through various materials has been studied with two MC codes, GEANT4 and MCNPX, showing a reasonably good agreement, inside 50% discrepancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance Self-Shielding: Why it is so Important

This paper is one of a series that I am writing to document my 58 years of experience with ENDF and Neutron Transport calculations, beginning when I worked at the National Nuclear Data Center (NNDC), Brookhaven National Laboratory (BNL), from 1967 to 1972. During those years I was the head of the computer unit of NNDC, assigned to develop computer codes to pre-process, view and test ENDF/B data. Since then, I have continued to support the ENDF effort without any official position or monetary compensation, because I realized how important accurate nuclear data is for use in use in our Engineering applications. It is so important to realize that regardless of how accurate or even perfect our application codes may be to transport particles, without accurate nuclear data we are in a “Garbage In = Garbage Out” situation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An evaluation of computer codes for simulating the Galileo Probe aerothermal entry environment

The approaches of three computer flow field codes (HYVIS, COLTS, and RASLE), used to determine the Galileo Probe aerothermal environment and its effect on the design of the thermal protection system, are analyzed in order to resolve differences in their predicted results. All three codes account for the hypersonic, massively blown, radiation shock layers, characteristic of Jupiter entry. Significant differences, however, are evident in their solution procedures: the governing conservation equations, the numerical differencing methods, the governing physics (chemical, radiation, diffusion, and turbulence models), and the basic physical data (thermodynamic, transport, chemical, and spectral properties for atomic and molecular species). Solutions are compared for two near peak heating entry conditions for a Galileo Probe baseline configuration, having an initial mass of 242 kg and simulating entry into the Orton nominal atmosphere. The modern numerical methodology of COLTS and RASLE appear to provide an improved capability for coupled flow-field solutions.

Menees, G. P.↗

Effect of Nuclear Data Covariances on Integral Experiment Design with Sensitivity and Uncertainty Analysis

Washington River Protection Solutions (WRPS) uses MCNP6.2 and the Whisper code for criticality safety analyses of the Hanford Tank Farm. Together the codes derive baseline upper subcritical limits (USLs) for the waste models using experimental benchmarks. Whisper returns higher USLs, i.e. , has less of a conservative penalty, when the neutronic similarity of the experimental benchmarks to the application is high. Unfortunately, few critical benchmarks have high similarity to the Hanford tanks. The waste in the tanks is highly dilute in plutonium and contains large masses of weakly neutron-absorbing elements like iron and manganese. Experimental benchmarks typically have low sensitivity to these absorbers because they are present as structural materials. Lacking similar benchmarks, new Thermal Epithermal eXperiment (TEX) configurations with high Pu content and interstitial iron absorbers have been designed for the criticality safety validation. The features of the design have been iterated upon to maximize the similarity between the experiment and different Hanford waste models. The similarity is quantified with sensitivity analysis and uncertainty quantification using the representativity coefficient, or c k . The representativity calculation requires nuclear data covariances, which may differ between nuclear data libraries and between library versions. Because of these variations, the optimal design may depend on the nuclear data covariances library. A scenario can be envisioned where an experiment is designed, and c k is maximized, with one set of covariance data. However, when the covariance data is changed, say from ENDF/B-VII.1 to ENDF/B-VIII.0, and the benchmark is used in a criticality safety evaluation, the experiment becomes suboptimal with respect to c k . In this paper, we present how the optimal design of the new TEX experiments varied depending on the nuclear data covariances used to calculate c k . We compare ENDF/B-VII.1 and ENDF/B-VIII.0, as if the library had been updated since the design of the experiment. Additionally, we use JEFF3.3 to simulate if the covariance data of a different library had been used. The results show that the covariances do have an important effect on the designs, less so for thermal systems (where the data are more consistent between evaluations) and more so for epithermal systems where more differences exist.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aerothermodynamics of Blunt Body Entry Vehicles

In this chapter, the aerothermodynamic phenomena of blunt body entry vehicles are discussed. Four topics will be considered that present challenges to current computational modeling techniques for blunt body environments: turbulent flow, non-equilibrium flow, rarefied flow, and radiation transport. Examples of comparisons between computational tools to ground and flight-test data will be presented in order to illustrate the challenges existing in the numerical modeling of each of these phenomena and to provide test cases for evaluation of Computational Fluid Dynamics (CFD) code predictions.

Hollis, Brian R.↗

Shielding from Space Radiations

This Final Progress Report for NCC-1-178 presents the details of the engineering development of an analytical/computational solution to the heavy ion transport equation in terms of a multi-layer Green's function formalism as applied to the Small Spacecraft Technology Initiative (SSTI) program. The mathematical developments are recasted into a series of efficient computer codes for space applications. The efficiency of applied algorithms is accomplished by a nonperturbative technique of extending the Green's function over the solution domain. The codes may also be applied to the accelerator boundary conditions to allow code validation in laboratory experiments. Correlations with experiments for the isotopic version of the code with 59 and 80 isotopes present for a two layers target material in water has been verified.

Chang, C. Ken↗

HFIR Activity Workbook Generator (HAWK) User Guide

The HFIR Activity WorkbooK generator (HAWK) is a Python code that automates and streamlines the activity calculation of samples after irradiation in the High Flux Isotope Reactor (HFIR). HAWK’s results provide estimates of the activity and nuclide inventory of irradiated specimens before they are moved to hot cell facilities, where they undergo post-irradiation examination. The samples’ activity results guide the packing of shipping containers and inform the accountable inventories for the hot cell facilities. The toolkit was originally developed by Charles Daily, a former R&D staff member at Oak Ridge National Laboratory (ORNL). As of May 2025, HAWK is developed by the Radiation Transport & HPC Methods Group (Nuclear Energy and Fuel Cycle Division) at ORNL. Figure 1 presents HAWK’s workflow. To use HAWK, users need to: 1. Develop an Excel input workbook (i.e., XLSX extension) containing data from the experiment’s materials, irradiation history (cycles), and irradiation positions. 2. Make minor edits to an existing template JSON file (i.e., auxiliary_data.JSON) and to the Python driver. The driver sets the necessary environment variables, defines the material compositions, and ultimately calls HAWK. Once configured, HAWK runs the Oak Ridge Isotope Generation code (ORIGEN) to calculate the masses, activities, and heat load at the end of irradiation for each isotope in the specimen. ORIGEN is part of SCALE, ORNL’s in-house computational tool for performing nuclear safety and design calculations. Following this step, HAWK postprocesses the results and generates three output workbooks summarizing the activity calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Influences of Neutron Irradiation on Aggregate Induced Degradation of Concrete

Reactor cavity concrete, the primary support structure for the reactor pressure vessel (RPV), is exposed to chronic neutron/gamma radiation during normal operation. During long term operation, the interaction of neutron irradiation with the concrete’s constituents may cause premature degradation of the concrete structure, as highlighted by a review of concrete properties in nuclear power plant environments. At high fluence levels, as in biological shielding, neutron irradiation may cause amorphization of the crystalline components of concrete, i.e., mineral aggregates, and volume changes, which are typically expansive in nature. Volume expansion can generate tensile stresses within concrete which can induce microcracking and/or result in debonding of aggregate with the matrix. On the other hand, structural disordering can result in changes in the stability of the phase in aqueous environments. This report presents the findings of investigations performed over 3 years through the collaboration of researchers from University of California, Los Angeles, Arizona State University, and Oak Ridge National Laboratory. The first part of the study addresses the effect of neutron irradiation on the durability of aggregates. Comparisons of aqueous dissolution rates, as a function of pH and temperature, were performed for aggregates that are either pristine (i.e., non-irradiated) or exposed to Ar+ ion irradiation at specified doses. These experimental results were coupled with molecular dynamics simulations of atomic scale changes in the crystallographic structure of the mineral and any resulting changes in physical properties (e.g., density) that result. The second section focuses on macroscopic effects of such changes in aggregate behavior in concrete degradation, primarily through changes in the concrete’s microstructure. Particularly, the effects akin to those originating from alkali-silica reaction (ASR) were evaluated. The project is structured to encompass 6 main tasks, as follows: Task 1: Selection of aggregates in relation to their abundance and mineralogy, and their irradiation Task 2: Molecular dynamics (MD): The effects of irradiation on the atomic disordering of aggregates Task 3: The influences of irradiation on aggregate reactivity Task 4: Reactive-transport simulation of expansive product formation in concrete microstructures Task 5: X-FEM-based modeling of damage evolution due to irradiation-induced aggregates reactions Task 6: Benchmarking, verification and validation of the simulation modules Thus, a rigorous understanding of irradiation-assisted mineral alterations was used to develop a mechanistic degradation model for concrete exposed to neutrons, while considering aspects of: chemical reaction (dissolution and precipitation), mass and ion transport, and damage evolutions. The models developed were embedded in a multi-physics aging code for nuclear components and structures called Grizzly, which allows for benchmarking, verification, and validation against expansion data acquired on concrete undergoing alkali-silica reaction, a physically/chemically equivalent form of degradation that develops in the absence of radiation. These findings provide insight into the sensitivities of minerals to irradiation, by highlighting characteristics of concretes and power plants subject to such risks. The research will aid the nuclear power industry to anticipate and mitigate such risks in light of second license renewals.

36 MATERIALS SCIENCE↗

Conceptual moderator studies for the Spallation Neutron Source short-pulse second target station

Candidate moderator configurations for a short-pulse second target station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) have been identified using a global optimizer framework built around the MCNPX particle transport code. Neutron brightness metrics were selected as the figure-of-merit. We assumed that STS would use one out of six proton pulses produced by an SNS accelerator upgraded to operate at 1.3 GeV proton energy, 2.8 MW power and 60 Hz repetition rate. The simulations indicate that the peak brightness can be increased by a factor of 5 and 2.5 on a per proton pulse basis compared to the SNS first target station for both coupled and decoupled para-hydrogen moderators, respectively. Additional increases by factors of 3 and 2 were demonstrated for coupled and decoupled moderators, respectively, by reducing the area of neutron emission from 100 × 100 mm{sup 2} to 20 × 20 mm{sup 2}. This increase in brightness has the potential to translate to an increase of beam intensity at the instruments’ sample positions even though the total neutron emission of the smaller moderator is less than that of the larger. This is especially true for instruments with small samples (beam dimensions). The increased fluxes in the STS moderators come at accelerated poison and de-coupler burnout and higher radiation-induced material damage rates per unit power, which overall translate into lower moderator lifetimes. A first effort was undertaken to group decoupled moderators into a cluster collectively positioning them at the peak neutron production zone in the target and having a three-port neutron emission scheme that complements that of a cylindrical coupled moderator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An update to the computation of the Goudsmit-Saunderson distribution in MCNP® version 6.2

To demonstrate how the number of terms used to compute the Goudsmit- Saunderson distribution impacts results, we study a thin foil problem where the outgoing angular distribution is observed for 20-MeV electrons. The foil thickness is roughly 1.5 times the default substep size for a 20-MeV electron in gold ( 2.8e -3 cm). Therefore, for the default substep size, electrons are guaranteed to undergo at least one collision before encountering a boundary (at which point an approximation is applied). In theory, one can improve the accuracy of the MCNP6.2 electron transport method by reducing the substep size. However, one must assume that the underlying data are valid. We show that when a user reduces the substep size, the angular distribution observed is different than expected, the primary reason being that the underlying data were not computed using a sufficient number of terms. We also show that the distribution is recovered when the number of terms is increased from hundreds to thousands. Here, we showed that stabilizing the underlying angular deflection distributions used in transport improves simulation results, particularly when default parameters are adjusted such that the substep size is reduced. Stabilization is achieved by adding more terms when computing the Goudsmit-Sanderson distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prediction of PFC Plasma Fluxes by Improved Edge/Scrape-off-layer Simulations

Large, localized plasma heat exhaust, subsequent inward transport of eroded impurities, and distribution of tritium to walls comprise one of the most critical class of problems for the development of tokamak fusion reactors. The magnitude and temporal duration of the heat fluxes is controlled by two factors: (1) the plasma power coming into the edge from the core, and (2), the physics processes in the edge/scrape-off-layer (SOL) that distribute the power to Plasma Facing Components (PFCs), both in space and in time. Given that the plasma power is largely determined by the fusion power desired, here I address model development needs for item (2), the distribution of power to PFCs, which naturally carries with it the capability for transport of impurities and tritium. Another key issue not addressed here is the impact of edge plasma transport on the plasma pedestal parameters. The nature of plasma transport in the edge/SOL region has long be differentiated from that in the bulk core, initially because of the larger fluctuation amplitudes that are observed, with density fluctuations relative to the time-average sometimes approaching as high as unity in the SOL. More recent measurements have shown addition effects such as strong intermittency, filamentation, toroidal asymmetry, and large flows [1]. These characteristics have a direct impact on plasma energy and particle fluxes to PFCs and on the flow of impurities in the edge. The theory of the edge/SOL is complicated by the steep gradients, multi-dimensional nature of plasma/neutral variations, and as mentioned above, the strong relative fluctuation levels compared to the core region. Furthermore, the strong interaction of the plasma with neutrals and the associated radiative effects for partially ionized plasma are important, Consequently, theoretical models typically need to be, or should be, more complicated, which may be one reason model development has lagged that in the core (funding being another reason). Simulation models of the edge/SOL can be divided into transport codes, which give the slow evolution of the plasma profiles and fluxes in a complex environment, and turbulence codes, which model the unstable, strongly fluctuating plasma state and thus (ideally) provide transport coefficients to the transport codes; this latter connect has only been made for a very limited set of simulations. The edge transport codes are either 2D fluid or now emerging 4D (2r,2v) kinetic. The turbulence codes are 2D and 3D fluid (only one U.S. 3D code spans the separatrix), and emerging 5D gyrokinetic codes. Many of the transport simulations to model plasma fluxes use ad hoc radial transport coefficients, rendering them more in the class of 'interpretive' simulations, not predictive; this limitation makes fundamental prediction for heat-flux widths and edge/SOL transport in general unobtainable at present. Even if there was a strong connection made between transport and turbulence codes, there is not yet a clear consensus in the community concerning the controlling instabilities and turbulence features, even for fixed plasma profiles. In comparison, the core turbulence simulations/theory/experiment have standard benchmarks (e.g., the Cyclone case), agree on many aspects of the big picture of the dominant ion transport, and have made good progress on electron transport. Again this core/edge difference can at least partially be traced to both the inherent difficulty of the edge problem and the stronger historical support for core simulation development; as the edge issue for high-power devices increases in importance, the funding prior should be change. No theory/simulation can be trusted without substantial experimental validation. The edge/SOL area is physically more accessible, but also more complex (2D-3D variations) and also different plasma parameters than for core diagnostics. Among the valuable diagnostics for transport are IRTV, thermocouples, Langmuir probes (but with maximum incident plasma power limitations), Thomson scattering, and visible. For turbulence diagnostics, we have spectroscopy, beam-emission spectroscopy (BES), again Langmuir probes, microwave backscatter, and gas-puff imaging. This list can be extended, but the point is that while significant diagnostics exist, improvements are clearly needed; for example, the characterization of the turbulence spanning the separatrix is modest except for BES at the midplane (probes have difficulty crossing the separatrix owing to heat-flux limitations). The residual turbulence in H-mode is generally not well characterized because of its lower (but still important?) magnitude.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model

Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: PENELOPE was first translated from FORTRAN to C++ and the result was confirmed to produce equivalent results to the original code. The C++ code was then adapted to CUDA in a workflow optimized for GPU architecture. The original code was expanded to include voxelized transport with Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, the vendor-provided MRIdian head model was incorporated into the code in an effort to apply gPENELOPE as both an accurate and rapid dose validation system. A set of experimental measurements were performed on the MRIdian system to examine the accuracy of both the head model and gPENELOPE. Ultimately, gPENELOPE was applied toward independent validation of patient doses calculated by MRIdian’s KMC. Results: An acceleration factor of 152 was achieved in comparison to the original single-thread FORTRAN implementation with the original accuracy being preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen(1), mediastinum (1), and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: A Monte Carlo simulation platform was developed based on a GPU- accelerated version of PENELOPE. This platform was used to validate that both the vendor-provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and accumulation, IMRT optimization, and dosimetry system modeling for next generation MR-IGRT systems.

60 APPLIED LIFE SCIENCES↗

Evaluation of S-values and dose distributions for {sup 90}Y, {sup 131}I, {sup 166}Ho, and {sup 188}Re in seven lobes of the rat liver

Purpose: Rats have been widely used in radionuclide therapy research for the treatment of hepatocellular carcinoma (HCC). This has created the need to assess rat liver absorbed radiation dose. In most dose estimation studies, the rat liver is considered as a homogeneous integrated target organ with a tissue composition assumed to be similar to that of human liver tissue. However, the rat liver is composed of several lobes having different anatomical and chemical characteristics. To assess the overall impact on rat liver dose calculation, the authors use a new voxel-based rat model with identified suborgan regions of the liver. Methods: The liver in the original cryosectional color images was manually segmented into seven individual lobes and subsequently integrated into a voxel-based computational rat model. Photon and electron particle transport was simulated using the MCNPX Monte Carlo code to calculate absorbed fractions and S-values for {sup 90}Y, {sup 131}I, {sup 166}Ho, and {sup 188}Re for the seven liver lobes. The effect of chemical composition on organ-specific absorbed dose was investigated by changing the chemical composition of the voxel filling liver material. Radionuclide-specific absorbed doses at the voxel level were further assessed for a small spherical hepatic tumor. Results: The self-absorbed dose for different liver lobes varied depending on their respective masses. A maximum difference of 3.5% was observed for the liver self-absorbed fraction between rat and human tissues for photon energies below 100 keV. {sup 166}Ho and {sup 188}Re produce a uniformly distributed high dose in the tumor and relatively low absorbed dose for surrounding tissues. Conclusions: The authors evaluated rat liver radiation doses from various radionuclides used in HCC treatments using a realistic computational rat model. This work contributes to a better understanding of all aspects influencing radiation transport in organ-specific radiation dose evaluation for preclinical therapy studies, from tissue composition to organ morphology and activity distribution.

61 RADIATION PROTECTION AND DOSIMETRY↗