Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ranking methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

AGATE: Adversarial Game Analysis for Tactical Evaluation

AGATE generates a set of ranked strategies that enables an autonomous vehicle to track/trail another vehicle that is trying to break the contact using evasive tactics. The software is efficient (can be run on a laptop), scales well with environmental complexity, and is suitable for use onboard an autonomous vehicle. The software will run in near-real-time (2 Hz) on most commercial laptops. Existing software is usually run offline in a planning mode, and is not used to control an unmanned vehicle actively. JPL has developed a system for AGATE that uses adversarial game theory (AGT) methods (in particular, leader-follower and pursuit-evasion) to enable an autonomous vehicle (AV) to maintain tracking/ trailing operations on a target that is employing evasive tactics. The AV trailing, tracking, and reacquisition operations are characterized by imperfect information, and are an example of a non-zero sum game (a positive payoff for the AV is not necessarily an equal loss for the target being tracked and, potentially, additional adversarial boats). Previously, JPL successfully applied the Nash equilibrium method for onboard control of an autonomous ground vehicle (AGV) travelling over hazardous terrain.

Huntsberger, Terrance L.↗

Road-corridor planning in the EIA procedure in Spain. A review of case studies

The assessment of different alternatives in road-corridor planning must be based on a number of well-defined territorial variables that serve as decision making criteria, and this requires a high-quality preliminary environmental assessment study. In Spain the formal specifications for the technical requirements stipulate the constraints that must be considered in the early stages of defining road corridors, but not how they should be analyzed and ranked. As part of the feasibility study of a new road definition, the most common methodology is to establish different levels of Territorial Carrying Capacity (TCC) in the study area in order to summarize the territorial variables on thematic maps and to ease the tracing process of road-corridor layout alternatives. This paper explores the variables used in 22 road-construction projects conducted by the Ministry of Public Works that were subject to the Spanish EIA regulation and published between 2006 and 2008. The aim was to evaluate the quality of the methods applied and the homogeneity and suitability of the variables used for defining the TCC. The variables were clustered into physical, environmental, land-use and cultural constraints for the purpose of comparing the TCC values assigned in the studies reviewed. We found the average quality of the studies to be generally acceptable in terms of the justification of the methodology, the weighting and classification of the variables, and the creation of a synthesis map. Nevertheless, the methods for assessing the TCC are not sufficiently standardized; there is a lack of uniformity in the cartographic information sources and methodologies for the TCC valuation. -- Highlights: • We explore 22 road-corridor planning studies subjected to the Spanish EIA regulation. • We analyze the variables selected for defining territorial carrying capacity. • The quality of the studies is acceptable (methodology, variable weighting, mapping). • There is heterogeneity in the methods for territorial carrying capacity valuation.

54 ENVIRONMENTAL SCIENCES↗

Use of a Conventional Low Neck Field (LNF) and Intensity-Modulated Radiotherapy (IMRT): No Clinical Detriment of IMRT to an Anterior LNF During the Treatment of Head-and Neck-Cancer

Purpose: To determine differences in clinical outcomes using intensity-modulated radiotherapy (IMRT) or a standard low neck field (LNF) to treat low neck. Methods and Materials: This is a retrospective, single-institution study. Ninety-one patients with squamous cell carcinoma of the head and neck were treated with curative intent. According to physician preference, some patients were treated with LNF (Planning Target Volume 3) field using a single anterior photon field matched to the IMRT field. Field junctions were not feathered. The endpoints were time to failure and use of a percutaneous endoscopic gastrostomy (PEG) tube (as a surrogate of laryngeal edema causing aspiration), and analysis was done with {chi}{sup 2} and log-rank tests. Results: Median follow-up was 21 months (range, 2-89 months). Median age was 60 years. Thirty-seven patients (41%) were treated with LNF, 84% were Stage III or IV. A PEG tube was required in 30%, as opposed to 33% without the use of LNF. Node 2 or 3 neck disease was treated more commonly without LNF (38% vs. 24%, p = 0.009). Failures occurred in 12 patients (13%). Only 1 patient treated with LNF failed regionally, 4.5 cm above the match line. The 3-year disease-free survival rate was 87% and 79% with LNF and without LNF, respectively (p = 0.2), and the 3-year LR failure rate was 4% and 21%, respectively (p = 0.04). Conclusions: Using LNF to treat the low neck did not increase the risk of regional failure 'in early T and early N diseases' or decrease PEG tube requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying Traversability of Terrain for a Mobile Robot

A document presents an updated discussion on a method of autonomous navigation for a robotic vehicle navigating across rough terrain. The method involves, among other things, the use of a measure of traversability, denoted the fuzzy traversability index, which embodies the information about the slope and roughness of terrain obtained from analysis of images acquired by cameras mounted on the robot. The improvements presented in the report focus on the use of the fuzzy traversability index to generate a traversability map and a grid map for planning the safest path for the robot. Once grid traversability values have been computed, they are utilized for rejecting unsafe path segments and for computing a traversalcost function for ranking candidate paths, selected by a search algorithm, from a specified initial position to a specified final position. The output of the algorithm is a set of waypoints designating a path having a minimal-traversal cost.

Howard, Ayanna↗

Medical Optimization Network for Space Telemedicine Resources

INTRODUCTION: Long-duration missions beyond low Earth orbit introduce new constraints to the space medical system such as the inability to evacuate to Earth, communication delays, and limitations in clinical skillsets. NASA recognizes the need to improve capabilities for autonomous care on such missions. As the medical system is developed, it is important to have an ability to evaluate the trade space of what resources will be most important. The Medical Optimization Network for Space Telemedicine Resources was developed for this reason, and is now a system to gauge the relative importance of medical resources in addressing medical conditions. METHODS: A list of medical conditions of potential concern for an exploration mission was referenced from the Integrated Medical Model, a probabilistic model designed to quantify in-flight medical risk. The diagnostic and treatment modalities required to address best and worst-case scenarios of each medical condition, at the terrestrial standard of care, were entered into a database. This list included tangible assets (e.g. medications) and intangible assets (e.g. clinical skills to perform a procedure). A team of physicians working within the Exploration Medical Capability Element of NASA's Human Research Program ranked each of the items listed according to its criticality. Data was then obtained from the IMM for the probability of occurrence of the medical conditions, including a breakdown of best case and worst case, during a Mars reference mission. The probability of occurrence information and criticality for each resource were taken into account during analytics performed using Tableau software. RESULTS: A database and weighting system to evaluate all the diagnostic and treatment modalities was created by combining the probability of condition occurrence data with the criticalities assigned by the physician team. DISCUSSION: Exploration Medical Capabilities research at NASA is focused on providing a medical system to support crew medical needs in the context of a Mars mission. MONSTR is a novel approach to performing a quantitative risk analysis that will assess the relative value of individual resources needed for the diagnosis and treatment of various medical conditions. It will provide the operational and research communities at NASA with information to support informed decisions regarding areas of research investment, future crew training, and medical supplies manifested as part of the exploration medical system.

Shah, R. V.↗

Emission line predictions for mock galaxy catalogues: a new differentiable and empirical mapping from DESI

ABSTRACT We present a simple, differentiable method for predicting emission line strengths from rest-frame optical continua using an empirically determined mapping. Extensive work has been done to develop mock galaxy catalogues that include robust predictions for galaxy photometry, but reliably predicting the strengths of emission lines has remained challenging. Our new mapping is a simple neural network implemented using the JAX Python automatic differentiation library. It is trained on Dark Energy Spectroscopic Instrument Early Release data to predict the equivalent widths (EWs) of the eight brightest optical emission lines (including H α, H β, [O ii], and [O iii]) from a galaxy’s rest-frame optical continuum. The predicted EW distributions are consistent with the observed ones when noise is accounted for, and we find Spearman’s rank correlation coefficient ρs > 0.87 between predictions and observations for most lines. Using a non-linear dimensionality reduction technique, we show that this is true for galaxies across the full range of observed spectral energy distributions. In addition, we find that adding measurement uncertainties to the predicted line strengths is essential for reproducing the distribution of observed line-ratios in the BPT diagram. Our trained network can easily be incorporated into a differentiable stellar population synthesis pipeline without hindering differentiability or scalability with GPUs. A synthetic catalogue generated with such a pipeline can be used to characterize and account for biases in the spectroscopic training sets used for training and calibration of photo-z’s, improving the modelling of systematic incompleteness for the Rubin Observatory LSST and other surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Benchmark Dose Analysis of DNA Damage Biomarker Responses Provides Compound Potency and Adverse Outcome Pathway Information for the Topoisomerase II Inhibitor Class of Compounds

Genetic toxicology data have traditionally been utilized for hazard identification to provide a binary call for a compound's risk. Recent advances in the scientific field, especially with the development of high‐throughput methods to quantify DNA damage, have influenced a change of approach in genotoxicity assessment. The in vitro MultiFlow® DNA Damage Assay is one such method which multiplexes γH2AX, p53, phospho‐histone H3 biomarkers into a single‐flow cytometric analysis (Bryce et al., [2016]: Environ Mol Mutagen 57:546–558). This assay was used to study human TK6 cells exposed to each of eight topoisomerase II poisons for 4 and 24 hr. Using PROAST v65.5, the Benchmark Dose approach was applied to the resulting flow cytometric datasets. With “compound” serving as covariate, all eight compounds were combined into a single analysis, per time point and endpoint. The resulting 90% confidence intervals, plotted in Log scale, were considered as the potency rank for the eight compounds. The in vitro MultiFlow data showed a maximum confidence interval span of 1Log, which indicates data of good quality. Patterns observed in the compound potency rank were scrutinized by using the expert rule‐based software program Derek Nexus, developed by Lhasa Limited. Compound sub‐classification and structural alerts were considered contributory to the potencies observed for the topoisomerase II poisons studied herein. The Topo II poison Adverse Outcome Pathway was evaluated with MultiFlow endpoints serving as Key Events. The step‐wise approach described herein can be considered as a foundation for risk assessment of compounds within a specific mode of action of interest. Environ. Mol. Mutagen. 2020. © 2020 Wiley Periodicals, Inc.

Wheeldon, Ryan P.↗

{sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography-Based Radiotherapy Target Volume Definition in Non-Small-Cell Lung Cancer: Delineation by Radiation Oncologists vs. Joint Outlining With a PET Radiologist?

Purpose: {sup 18}F-Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) has benefits in target volume (TV) definition in radiotherapy treatment planning (RTP) for non-small-cell lung cancer (NSCLC); however, an optimal protocol for TV delineation has not been determined. We investigate volumetric and positional variation in gross tumor volume (GTV) delineation using a planning PET/CT among three radiation oncologists and a PET radiologist. Methods and Materials: RTP PET/CT scans were performed on 28 NSCLC patients (Stage IA-IIIB) of which 14 patients received prior induction chemotherapy. Three radiation oncologists and one PET radiologist working with a fourth radiation oncologist independently delineated the GTV on CT alone (GTV{sub CT}) and on fused PET/CT images (GTV{sub PETCT}). The mean percentage volume change (PVC) between GTV{sub CT} and GTV{sub PETCT} for the radiation oncologists and the PVC between GTV{sub CT} and GTV{sub PETCT} for the PET radiologist were compared using the Wilcoxon signed-rank test. Concordance index (CI) was used to assess both positional and volume change between GTV{sub CT} and GTV{sub PETCT} in a single measurement. Results: For all patients, a significant difference in PVC from GTV{sub CT} to GTV{sub PETCT} exists between the radiation oncologist (median, 5.9%), and the PET radiologist (median, -0.4%, p = 0.001). However, no significant difference in median concordance index (comparing GTV{sub CT} and GTV{sub FUSED} for individual cases) was observed (PET radiologist = 0.73; radiation oncologists = 0.66; p = 0.088). Conclusions: Percentage volume changes from GTV{sub CT} to GTV{sub PETCT} were lower for the PET radiologist than for the radiation oncologists, suggesting a lower impact of PET/CT in TV delineation for the PET radiologist than for the oncologists. Guidelines are needed to standardize the use of PET/CT for TV delineation in RTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiation Therapy in Oropharyngeal Carcinoma: Effect of Tumor Volume on Clinical Outcomes

Purpose: To analyze the effect of primary gross tumor volume (pGTV) and nodal gross tumor volume (nGTV) on treatment outcomes in patients treated with definitive intensity-modulated radiation therapy (IMRT) for oropharyngeal cancer (OPC). Methods and Materials: Between September 1998 and April 2009, a total of 442 patients with squamous cell carcinoma of the oropharynx were treated with IMRT with curative intent at our center. Thirty patients treated postoperatively and 2 additional patients who started treatment more than 6 months after diagnosis were excluded. A total of 340 patients with restorable treatment plans were included in this present study. The majority of the patients underwent concurrent platinum-based chemotherapy. The pGTV and nGTV were calculated using the original clinical treatment plans. Cox proportional hazards models and log-rank tests were used to evaluate the correlation between tumor volumes and overall survival (OS), and competing risks analysis tools were used to evaluate the correlation between local failure (LF), regional failure (RF), distant metastatic failure (DMF) vs. tumor volumes with death as a competing risk. Results: Median follow-up among surviving patients was 34 months (range, 5-67). The 2-year cumulative incidence of LF, RF and DF in this cohort of patients was 6.1%, 5.2%, and 12.2%, respectively. The 2-year OS rate was 88.6%. Univariate analysis determined pGTV and T-stage correlated with LF (p < 0.0001 and p = 0.004, respectively), whereas nGTV was not associated with RF. On multivariate analysis, pGTV and N-stage were independent risk factors for overall survival (p = 0.0003 and p = 0.0073, respectively) and distant control (p = 0.0008 and p = 0.002, respectively). Conclusions: In this cohort of patients with OPC treated with IMRT, pGTV was found to be associated with overall survival, local failure, and distant metastatic failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monitoring the propagation of mechanical discontinuity using data-driven causal discovery and supervised learning

Mechanical wave transmission through a material is influenced by the mechanical discontinuity in the material. The propagation of embedded discontinuities can be monitored by analyzing the wave-transmission measurements recorded by a multipoint sensor system placed on the surface of the material. The proposed workflow monitors the propagation of mechanical discontinuity through three stages, namely initial, intermediate, and final stages, by using supervised learning followed by data-driven causal discovery. To the end, the workflow processes the multipoint waveform measurements resulting from a single impulse source, while considering the effects of wave attenuation, dispersion and multiple wave-propagation modes due to the discontinuity and material boundaries. Among various feature reduction techniques ranging from decomposition methods to manifold approximation methods, the features derived based on statistical parameterizations of the measured waveforms lead to reliable monitoring that is robust to changes in precision, resolution, and signal-to-noise ratio of the multipoint sensor measurements. The numbers of zero-crossing, negative-turning, and positive turning in the waveforms are the strongest causal signatures of the propagation of mechanical discontinuity. Higher order moments of the waveforms, such as variance, skewness and kurtosis, are also strong causal signatures of the propagation. Finally, the newly discovered causal signatures confirm that the statistical correlations and conventional feature rankings are not always statistically significant indicators of causality.

42 ENGINEERING↗

Unveiling the Milky Way: A new technique for determining the optical color and luminosity of our galaxy

We demonstrate a new statistical method of determining the global photometric properties of the Milky Way (MW) to an unprecedented degree of accuracy, allowing our Galaxy to be compared directly to objects measured in extragalactic surveys. Capitalizing on the high-quality imaging and spectroscopy data set from the Sloan Digital Sky Survey (SDSS), we exploit the inherent dependence of galaxies’ luminosities and colors on their total stellar mass, M{sub ⋆}, and star formation rate (SFR), M-dot {sub ⋆}, by selecting a sample of Milky Way analog galaxies designed to reproduce the best Galactic M{sub ⋆} and M-dot {sub ⋆} measurements, including all measurement uncertainties. Making the Copernican assumption that the MW is not extraordinary among galaxies of similar stellar mass and SFR, we then analyze the photometric properties of this matched sample, constraining the characteristics of our Galaxy without suffering interference from interstellar dust. We explore a variety of potential systematic errors that could affect this method, and find that they are subdominant to random uncertainties. We present both SDSS ugriz absolute magnitudes and colors in both rest-frame z = 0 and z = 0.1 passbands for the MW, which are in agreement with previous estimates but can have up to ∼3× lower errors. We find the MW to have absolute magnitude {sup 0}M{sub r}−5logh=−21.00{sub −0.37}{sup +0.38} and integrated color {sup 0}(g−r)=0.682{sub −0.056}{sup +0.066}, indicating that it may belong to the green-valley region in color–magnitude space and ranking it among the brightest and reddest of spiral galaxies. We also present new estimates of global stellar mass-to-light ratios for our Galaxy. This work will help relate our in-depth understanding of the Galaxy to studies of more distant objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Fat Composition Changes in Bone Marrow During Chemotherapy and Radiation Therapy

Purpose: To quantify changes in bone marrow fat fraction and determine associations with peripheral blood cell counts. Methods and Materials: In this prospective study, 19 patients received either highly myelotoxic treatment (radiation therapy plus cisplatin, 5-fluorouracil mitomycin C [FU/MMC], or cisplatin/5-FU/cetuximab) or less myelotoxic treatment (capecitabine-radiation therapy or no concurrent chemotherapy). Patients underwent MR imaging and venipuncture at baseline, midtreatment, and posttreatment visits. We performed mixed effects modeling of the mean proton density fat fraction (PDFF[%]) by linear time, treatment, and vertebral column region (lumbar [L]4-sacral [S]2 vs thoracic [T]10-L3 vs cervical[C]3-T9), while controlling for cumulative mean dose and other confounders. Spearman rank correlations were performed by white blood cell (WBC) counts versus the differences in PDFF(%) before and after treatment. Results: Cumulative mean dose was associated with a 0.43% per Gy (P=.004) increase in PDFF(%). In the highly myelotoxic group, we observed significant changes in PDFF(%) per visit within L4-S2 (10.1%, P<.001) and within T10-L3 (3.93%, P=.01), relative to the reference C3-T9. In the less myelotoxic group, we did not observe significant changes in PDFF(%) per visit according to region. Within L4-S2, we observed a significant difference between treatment groups in the change in PDFF(%) per visit (5.36%, P=.04). Rank correlations of the inverse log differences in WBC versus the differences in PDFF(%) overall and within T10-S2 ranged from 0.69 to 0.78 (P<.05). Rank correlations of the inverse log differences in absolute neutrophil counts versus the differences in PDFF(%) overall and within L4-S2 ranged from 0.79 to 0.81 (P<.05). Conclusions: Magnetic resonance imaging fat quantification is sensitive to marrow composition changes that result from chemoradiation therapy. These changes are associated with peripheral blood cell counts. This study supports a rationale for bone marrow-sparing treatment planning to reduce the risk of hematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medical Malpractice Claims in Radiation Oncology: A Population-Based Study 1985-2012

Purpose: The purpose of this study was to determine trends in radiation oncology malpractice claims and expenses during the last 28 years and to compare radiation oncology malpractice claims to those of other specialties. Methods and Materials: We performed a retrospective analysis of closed malpractice claims filed from 1985 to 2012, collected by a nationwide medical liability insurance trade association. We analyzed characteristics and trends among closed claims, indemnity payments (payments to plaintiff), and litigation expenses. We also compared radiation oncology malpractice claims to those of 21 other medical specialties. Time series dollar amounts were adjusted for inflation (2012 was the index year). Results: There were 1517 closed claims involving radiation oncology, of which 342 (22.5%) were paid. Average and median indemnity payments were $276,792 and $122,500, respectively, ranking fifth and eighth, respectively, among the 22 specialty groups. Linear regression modeling of time trends showed decreasing total numbers of claims (β = −1.96 annually, P=.003), increasing average litigation expenses paid (β = +$1472 annually, P≤.001), and no significant changes in average indemnity payments (β = −$681, P=.89). Conclusions: Medical professional liability claims filed against radiation oncologists are not common and have declined in recent years. However, indemnity payments in radiation oncology are large relative to those of many other specialties. In recent years, the average indemnity payment has been stable, whereas litigation expenses have increased.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mammalian Target of Rapamycin Inhibition With Rapamycin Mitigates Radiation-Induced Pulmonary Fibrosis in a Murine Model

Purpose: Radiation-induced pulmonary fibrosis (RIPF) is a late toxicity of therapeutic radiation. Signaling of the mammalian target of rapamycin drives several processes implicated in RIPF, including inflammatory cytokine production, fibroblast proliferation, and epithelial senescence. We sought to determine if mammalian target of rapamycin inhibition with rapamycin would mitigate RIPF. Methods and Materials: C57BL/6NCr mice received a diet formulated with rapamycin (14 mg/kg food) or a control diet 2 days before and continuing for 16 weeks after exposure to 5 daily fractions of 6 Gy of thoracic irradiation. Fibrosis was assessed with Masson trichrome staining and hydroxyproline assay. Cytokine expression was evaluated by quantitative real-time polymerase chain reaction. Senescence was assessed by staining for β-galactosidase activity. Results: Administration of rapamycin extended the median survival of irradiated mice compared with the control diet from 116 days to 156 days (P=.006, log-rank test). Treatment with rapamycin reduced hydroxyproline content compared with the control diet (irradiation plus vehicle, 45.9 ± 11.8 μg per lung; irradiation plus rapamycin, 21.4 ± 6.0 μg per lung; P=.001) and reduced visible fibrotic foci. Rapamycin treatment attenuated interleukin 1β and transforming growth factor β induction in irradiated lungs compared with the control diet. Type II pneumocyte senescence after irradiation was reduced with rapamycin treatment at 16 weeks (3-fold reduction at 16 weeks, P<.001). Conclusions: Rapamycin protected against RIPF in a murine model. Rapamycin treatment reduced inflammatory cytokine expression, extracellular matrix production, and senescence in type II pneumocytes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of an Enhanced Metaproteomic Approach for Deepening the Microbiome Characterization of the Human Infant Gut

The early-life microbiota establishment in the human infant gut is highly variable and plays a crucial role in host nutrients and immunity maturation. While high-performance mass spectrometry (MS)-based metaproteomics is a powerful method for the functional characterization of complex microbial communities, the construction of comprehensive metaproteomic information in human fecal samples is inhibited by the presence of abundant human proteins. To alleviate this restriction, we have designed a novel metaproteomic strategy based on Double Filtering (DF) to enhance microbial protein characterization in complex fecal samples from healthy premature infants. We improved the overall depth of infant gut proteome measurement, with an increase in the number of identified low abundance proteins, and observed greater than twofold improvement in metrics for microbial protein identifications and quantifications with a relatively high rank correlation to control. We further showed the substantial enhancement of this approach for extensively interpreting microbial functional categories between infants by affording more detailed and confident identified categories. This approach provided an avenue for in-depth measurement in the microbial component of infant fecal samples and thus comprehensive characterization of infant gut microbiome functionality.

60 APPLIED LIFE SCIENCES↗

Uncertainty quantification of calculated temperatures for advanced gas reactor fuel irradiation experiments

This paper presents the quantification of uncertainty of the calculated temperature data for the Advanced Gas Reactor (AGR) fuel irradiation experiments conducted in the Advanced Test Reactor at Idaho National Laboratory in support of the Advanced Reactor Technology Research and Development program. Recognizing uncertainties inherent in physics and thermal simulations of the AGR tests, the results of the numerical simulations are used in combination with statistical analysis methods to improve qualification of measured data. The temperature simulation data for AGR tests are also used for validation of the fission product transport and fuel performance simulation models. These crucial roles of the calculated fuel temperatures in ensuring achievement of the AGR experimental program objectives require accurate determination of the model temperature uncertainties. To quantify the uncertainty of AGR calculated temperatures, this study identifies and analyzes ABAQUS model parameters of potential importance to the AGR predicted fuel temperatures. The selection of input parameters for uncertainty quantification of the AGR calculated temperatures is based on the ranking of their influences on variation of temperature predictions. Thus, selected input parameters include those with high sensitivity and those with large uncertainty. Propagation of model parameter uncertainty and sensitivity is then used to quantify the overall uncertainty of AGR calculated temperatures. Expert judgment is used as the basis to specify the uncertainty range for selected input parameters. The input uncertainties are dynamic accounting for the effect of unplanned events and changes in thermal properties of capsule components over extended exposure to high temperature and fast neutron irradiation. The sensitivity analysis performed in this work went beyond the traditional local sensitivity. Using experimental design, analysis of pairwise interactions of model parameters was performed to establish sufficiency of the first-order (linear) expansion terms in constructing the response surface. To achieve completeness, uncertainty propagation made use of pairwise noise correlations of model parameters. Furthermore, time-dependent sensitivity over the test campaign duration was obtained using an interpolation scheme over the input parameter domain. This allows computation of uncertainty for the predicted peak fuel temperatures and the predicted graphite temperatures at TC locations over the whole AGR irradiation period.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A study of the frictional and stick-slip behavior of magnetic recording tapes

Methods were developed to determine the coefficient of friction and the extent of stick-slip of magnetic recording tapes. After a preliminary phase during which experimental procedures were established and screening of candidate tapes was carried out, the frictional and stick-slip behavior of four selected tapes, using four different kinds of magnetic heads, was studied at various temperatures, under dry and humid conditions, and in various gaseous atmospheres, such as argon, helium, nitrogen and air. The effects of tape speed and outgassing on the drag properties of the tapes were also studied. A rank was assigned to each tape and magnetic head as a result of these tests. This study helped in the selection of a magnetic tape in a flight project, and will be useful in the consideration of tapes and magnetic heads for future spacecraft applications.

Kalfayan, S. H.↗

Evaluating Algorithm Performance Metrics Tailored for Prognostics

Prognostics has taken a center stage in Condition Based Maintenance (CBM) where it is desired to estimate Remaining Useful Life (RUL) of the system so that remedial measures may be taken in advance to avoid catastrophic events or unwanted downtimes. Validation of such predictions is an important but difficult proposition and a lack of appropriate evaluation methods renders prognostics meaningless. Evaluation methods currently used in the research community are not standardized and in many cases do not sufficiently assess key performance aspects expected out of a prognostics algorithm. In this paper we introduce several new evaluation metrics tailored for prognostics and show that they can effectively evaluate various algorithms as compared to other conventional metrics. Specifically four algorithms namely; Relevance Vector Machine (RVM), Gaussian Process Regression (GPR), Artificial Neural Network (ANN), and Polynomial Regression (PR) are compared. These algorithms vary in complexity and their ability to manage uncertainty around predicted estimates. Results show that the new metrics rank these algorithms in different manner and depending on the requirements and constraints suitable metrics may be chosen. Beyond these results, these metrics offer ideas about how metrics suitable to prognostics may be designed so that the evaluation procedure can be standardized. 1

Saxena, Abhinav↗