Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rate capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Carbon dioxide absorber and regeneration assemblies useful for power plant flue gas

Disclosed are apparatus and method to treat large amounts of flue gas from a pulverized coal combustion power plant. The flue gas is contacted with solid sorbents to selectively absorb CO.sub.2, which is then released as a nearly pure CO.sub.2 gas stream upon regeneration at higher temperature. The method is capable of handling the necessary sorbent circulation rates of tens of millions of lbs/hr to separate CO.sub.2 from a power plant's flue gas stream. Because pressurizing large amounts of flue gas is cost prohibitive, the method of this invention minimizes the overall pressure drop in the absorption section to less than 25 inches of water column. The internal circulation of sorbent within the absorber assembly in the proposed method not only minimizes temperature increases in the absorber to less than 25.degree. F., but also increases the CO.sub.2 concentration in the sorbent to near saturation levels. Saturating the sorbent with CO.sub.2 in the absorber section minimizes the heat energy needed for sorbent regeneration. The commercial embodiments of the proposed method can be optimized for sorbents with slower or faster absorption kinetics, low or high heat release rates, low or high saturation capacities and slower or faster regeneration kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ACCELERATING FUSION REACTOR NEUTRONICS MODELING BY AUTOMATIC COUPLING OF HYBRID MONTE CARLO/DETERMINISTIC TRANSPORT ON CAD GEOMETRY

Detailed radiation transport calculations are necessary for many aspects of the design of fusion energy systems (FES) such as ensuring occupational safety, assessing the activation of system components for waste disposal, and maintaining cryogenic temperatures within superconducting magnets. Hybrid Monte Carlo (MC)/deterministic techniques are necessary for this analysis because FES are large, heavily shielded, and contain streaming paths that can only be resolved with MC. The tremendous complexity of FES necessitates the use of CAD geometry for design and analysis. Previous ITER analysis has required the translation of CAD geometry to MCNP5 form in order to use the AutomateD VAriaNce reducTion Generator (ADVANTG) for hybrid MC/deterministic transport. In this work, ADVANTG was modified to support CAD geometry, allowing hybrid (MC)/deterministic transport to be done automatically and eliminating the need for this translation step. This was done by adding a new ray tracing routine to ADVANTG for CAD geometries using the Direct Accelerated Geometry Monte Carlo (DAGMC) software library. This new capability is demonstrated with a prompt dose rate calculation for an ITER computational benchmark problem using both the Consistent Adjoint Driven Importance Sampling (CADIS) method an the Forward Weighted (FW)-CADIS method. The variance reduction parameters produced by ADVANTG are shown to be the same using CAD geometry and standard MCNP5 geometry. Significant speedups were observed for both neutrons (as high as a factor of 7.1) and photons (as high as a factor of 59.6).

Biondo, Elliott D↗

The used nuclear fuel problem - can reprocessing and consolidated storage be complementary?

This paper describes our CISF (Consolidated Interim Storage Facilities) and Reprocessing Facility concepts and show how they can be combined with a geologic repository to provide a comprehensive system for dealing with spent fuels in the USA. The performance of the CISF was logistically analyzed under six operational scenarios. A 3-stage plan has been developed to establish the CISF. Stage 1: the construction at the CISF site of only a rail receipt interface and storage pad large enough for the number of casks that will be received. The construction of the CISF Canister Handling Facility, the Storage Cask Fabrication Facility, the Cask Maintenance Facility and supporting infrastructure are performed during stage 2. The construction and placement into operation of a water-filled pool repackaging facility is completed for Stage 3. By using this staged approach, the capital cost of the CISF is spread over a number of years. It also allows more time for a final decision on the geologic repository to be made. A recycling facility will be built, this facility will used the NUEX recycling process that is based on the aqueous-based PUREX solvent extraction process, using a solvent of tri-N-butyl phosphate in a kerosene diluent. It is capable of processing spent fuels at a rate of 5 MT per day, at burn-ups up to 50 GWD per ton of spent fuels and a minimum of 5 years out-of-reactor cooling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pulse shaping and energy storage capabilities of angularly multiplexed KrF laser fusion drivers

This paper describes a rep-rated multibeam KrF laser driver design for the 500 kJ Inertial Fusion test Facility (FTF) recently proposed by NRL, then models its optical pulse shaping capabilities using the ORESTES laser kinetics code. It describes a stable and reliable iteration technique for calculating the required precompensated input pulse shape that will achieve the desired output shape, even when the amplifiers are heavily saturated. It also describes how this precompensation technique could be experimentally implemented in real time on a reprated laser system. The simulations show that this multibeam system can achieve a high fidelity pulse shaping capability, even for a high gain shock ignition pulse whose final spike requires output intensities much higher than the approx4 MW/cm{sup 2} saturation levels associated with quasi-cw operation; i.e., they show that KrF can act as a storage medium even for pulsewidths of approx1 ns. For the chosen pulse, which gives a predicted fusion energy gain of approx120, the simulations predict the FTF can deliver a total on-target energy of 428 kJ, a peak spike power of 385 TW, and amplified spontaneous emission prepulse contrast ratios I{sub ASE}/I<3x10{sup -7} in intensity and F{sub ASE}/F<1.5x10{sup -5} in fluence. Finally, the paper proposes a front-end pulse shaping technique that combines an optical Kerr gate with cw 248 nm light and a 1 mum control beam shaped by advanced fiber optic technology, such as the one used in the National Ignition Facility (NIF) laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Meteodrone data

The University of Nebraska-Lincoln (UNL) Meteodrone (model SSE MM-641) is a small (1.1 kg GTOW, ~40 cm across) hexcopter UAS manufactured by Meteomatics. Maximum endurance is approximately 30 min and estimated maximum operating altitude of 1500 m. Profiles can be executed at ascent/descent rates up to 10 m/s. The Meteodrone is capable of measuring temperature, relative humidity, wind velocity and GPS position time-stamped with GPS time. Temperature and dual relative humidity sensors are shielded from solar exposure by a housing with a vertically oriented air intake and hoirizontal exhaust. Sensor aspiration is driven by rotorwash across the horizontal exhaust. In its current configuration data are recorded only when executing vertical profiles. Attitude and position are updated at a data rate of 20 Hz while meteorological observations are updated at 10 Hz.

54 ENVIRONMENTAL SCIENCES↗

Towards a microchannel-based X-ray detector with two-dimensional spatial and time resolution and high dynamic range

X-ray detectors that combine two-dimensional spatial resolution with a high time resolution are needed in numerous applications of synchrotron radiation. Most detectors with this combination of capabilities are based on semiconductor technology and are therefore limited in size. Furthermore, the time resolution is often realised through rapid time-gating of the acquisition, followed by a slower readout. Here, a detector technology is realised based on relatively inexpensive microchannel plates that uses GHz waveform sampling for a millimeter-scale spatial resolution and better than 100 ps time resolution. The technology is capable of continuous streaming of time- and location-tagged events at rates greater than 10(7) events per cm(2). Time-gating can be used for improved dynamic range.

Adams, Bernhard W.↗

Effect of Heat and Electricity Storage and Reliability on Microgrid Viability: A Study of Commercial Buildings in California and New York States

Berkeley Lab has for several years been developing methods for selection of optimal microgrid systems, especially for commercial building applications, and applying these methods in the Distributed Energy Resources Customer Adoption Model (DER-CAM). This project began with 3 major goals: (1) to conduct detailed analysis to find the optimal equipment combination for microgrids at a few promising commercial building hosts in the two favorable markets of California and New York, (2) to extend the analysis capability of DER-CAM to include both heat and electricity storage, and (3) to make an initial effort towards adding consideration of power quality and reliability (PQR) to the capabilities of DER-CAM. All of these objectives have been pursued via analysis of the attractiveness of a Consortium for Electric Reliability Technology Solutions (CERTS) Microgrid consisting of multiple nameplate 100 kW Tecogen Premium Power Modules (CM-100). This unit consists of an asynchronous inverter-based variable speed internal combustion engine genset with combined heat and power (CHP) and power surge capability. The essence of CERTS Microgrid technology is that smarts added to the on-board power electronics of any microgrid device enables stable and safe islanded operation without the need for complex fast supervisory controls. This approach allows plug and play development of a microgrid that can potentially provide high PQR with a minimum of specialized site-specific engineering. A notable feature of the CM-100 is its time-limited surge rating of 125 kW, and DER-CAM capability to model this feature was also a necessary model enhancement.

25 ENERGY STORAGE↗

Hybrid Heavy Duty Diesel Powertrain for Off-Road Applications (Final Technical/Scientific Report)

In this program, a heavy-duty hybrid powersystem, consisting of a 30% downsized diesel engine and a front-end accessory drive (FEAD) incorporating a high-speed flywheel (HSFW) energy storage system, a mechanical-drive turbocharger (SuperTurbo), and motor-generator units (MGU) was developed and demonstrated. The high efficiency core 13L engine coupled with the hybrid elements was physically validated across various off-road machine and transient work cycles with the ultimate goal of demonstrating 17% efficiency improvement with equivalent transient response as the 18L diesel engine this concept powersystem would replace. The project culminated in a physical demonstration of the high-efficiency powersystem in a high-capability test cell with the engine, all the hybrid devices, controls, and required performance and emissions measurements. Based on the combination of physical validation and rigorous system simulation, the following program conclusions may be drawn: (1) The developed hybrid H2D2 powersystem demonstrated a range of efficiency improvement of 10.5 - 25.6%, with a midpoint of 17.9%; (2) Transient load response on; (3) The HSFW system was validated to achieve peak assisting of 110kW at 12,000 Nm/sec ramp rates; (4) The powersystem was validated to be capable of meeting U.S. EPA Tier 4 Final off-road emissions through transient NRTC testing; (5) A Total Cost of Ownership (TCO) analysis and found that the core 13L engine would pay back immediately (adoption of start/stop would pay back in less than one year, and the full hybrid system payback was three years.)

33 ADVANCED PROPULSION SYSTEMS↗

Understanding particle size effect on fast-charging behavior of graphite anode using ultra-thin-layer electrodes

Extreme fast charging (≤ 15 min) of lithium-ion batteries is highly desirable to accelerate mass-market adoption of electric vehicles. However, significant capacity fading, as well as safety issues due to the lithium plating caused by the fast charging rate, limit its implementation. In this study, we investigated the fast-charging capability of graphite materials with various particle sizes. To eliminate the Li + ion concentration gradient effect across the thickness of the electrode, ultra-thin-layer graphite electrodes were developed to investigate the "real" fast-charging capability of graphite at the particle level. Electrochemical assessments as well as microscopic characterizations revealed that smaller particles exhibited superior fast-charging performance, featuring enhanced capacity reversibility, faster charging rate, and less lithium plating under the same fast-charging conditions. It is shown that small-particle graphite (mean radius of 3.3 μm) could withstand a 4C charge (to 80 % state-of-charge) without plating, with minimal plating occurring at 6C. Thicker particles exhibited plating at lower C-rates. Since the experimental data could not directly explain whether intra-particle diffusion limitations or interfacial reaction limitations dominated the plating mechanism, the pseudo-2-dimensional model was used to evaluate the most likely plating mechanism. The model suggested that particle-level diffusion is the dominant mechanism contributing to plating at high rates. Finally, this work provides comprehensive insights into the particle size effects on fast-charging capability, offering a better understanding of fast-charging behavior and valuable guidance for designing optimal electrode architecture for high-rate lithium-ion batteries.

25 ENERGY STORAGE↗

High-brightness beam tests of the very high frequency gun at the Advanced Photo-injector EXperiment test facility at the Lawrence Berkeley National Laboratory

The very-high-frequency gun (VHF-Gun) is a new concept photo-injector developed and built at the Lawrence Berkeley National Laboratory (LBNL) for generating high-brightness electron beams capable of driving X-ray free electron lasers (FELs) at MHz-class repetition rates. The gun that purposely uses established and mature radiofrequency and mechanical technologies has demonstrated over the last many years the capability of reliably operating in continuous wave mode at the design accelerating fields and required vacuum and mechanical performance. The conclusions of VHF-Gun technology demonstration were reported elsewhere [Sannibale et al., Phys. Rev. Spec. Top.-Accel. Beams 15, 103501 (2012)]; here in this work, we provide and analyze examples of the experimental results of the first high-brightness beam tests performed at the Advanced Photo-injector EXperiment test facility at LBNL that demonstrated the gun capability of delivering the beam quality required for driving high repetition rate X-ray FELs.

47 OTHER INSTRUMENTATION↗

Time-gated single-photon detection module with 110 ps transition time and up to 80 MHz repetition rate

We present the design and characterization of a complete single-photon counting module capable of time-gating a silicon single-photon avalanche diode with ON and OFF transition times down to 110 ps, at repetition rates up to 80 MHz. Thanks to this sharp temporal filtering of incoming photons, it is possible to reject undesired strong light pulses preceding (or following) the signal of interest, allowing to increase the dynamic range of optical acquisitions up to 7 decades. A complete experimental characterization of the module highlights its very flat temporal response, with a time resolution of the order of 30 ps. The instrument is fully user-configurable via a PC interface and can be easily integrated in any optical setup, thanks to its small and compact form factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of silica matrix composition and functional component additives on the bioactivity and viability of encapsulated living cells

The remarkable impact encapsulation matrix chemistry can have on the bioactivity and viability of integrated living cells is reported. Two silica chemistries (aqueous silicate and alkoxysilane), and a functional component additive (glycerol), are employed to generate three distinct silica matrices. These matrices are used to encapsulate living E. coli cells engineered with a synthetic riboswitch for cell-based biosensing. Following encapsulation, membrane integrity, reproductive capability, and riboswitch-based protein expression levels and rates are measured over a 5 week period. Striking differences in E. coli bioactivity, viability, and biosensing performance are observed for cells encapsulated within the different matrices. E. coli cells encapsulated for 35 days in aqueous silicate-based (AqS) matrices showed relatively low membrane integrity, but high reproductive capability in comparison to cells encapsulated in glycerol containing sodium silicate-based (AqS + g) and alkoxysilane-based (PGS) gels. Further, cells in sodium silicate-based matrices showed increasing fluorescence output over time, resulting in a 1.8-fold higher fluorescence level, and a faster expression rate, over cells free in solution. Furthermore, this unusual and unique combination of biological properties demonstrates that careful design of the encapsulation matrix chemistry can improve functionality of the biocomposite material, and result in new and unexpected physiological states.

59 BASIC BIOLOGICAL SCIENCES↗

(U) LNK3DNT Capability in SENSMG Tested with Transport Correction

The SENSMG multigroup neutron sensitivity code can read materials and geometry from redoin and lnk3dnt files written by the PARTISN multigroup discrete ordinates code or the MCNP6 Monte Carlo code. Reference 5 described an initial version of this capability. Reference 6 introduced two important extensions: 1) Reaction-rate ratios are now allowed as responses with redoin/lnk3dnt inputs; and 2) Sensitivities of reaction-rate ratios to mass densities and interface locations are now calculated (for all problems, not just redoin/lnk3dnt problems). In this report, we document the testing of the redoin/lnk3dnt capability when used with transport correction. PARTISN’s transport corrections are described in Ref. 3, and Refs. 7 and 8 discuss the calculation of cross-section sensitivities when transport corrections are applied. References 7 and 8 verify SENSMG for problems with transport correction using central differences. This report verifies the capability with redoin/lnk3dnt inputs by comparison with regular SENSMG inputs. Unlike Refs. 5 and 6, in this report we use a spherical test problem because the sensitivity of the response with respect to the highest-order scattering is zero in cylinders due to the use of flux moments in the inner products.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating transients with NekRS: GPU overlapping domain implementation and multi-rate timestepping

The simulation of nuclear transients using Computational Fluid Dynamics (CFD) presents significant computational challenges due to the inherent complexity and the wide separation in temporal scales between various flow physical phenomena. These disparities lead to high computational costs, often making the simulation of transients impractical without advanced techniques. Consequently, multiple research initiatives are being pursued by the NEAMS thermal-hydraulic area, some driven by academic institutions and some by national laboratories. Overall, they are exploring novel methods to make transient simulations more feasible and efficient. This report delves into recent advancements within the CFD code NekRS, specifically those achieved in Fiscal Year 2024 under the CONNECT effort, aimed at improving the performance and feasibility of transient simulations. The first major advancement involves the porting of NekRS to Aurora, one of the Department of Energy’s (DOE) most powerful supercomputers. Additionally, the report discusses the implementation of an overlapping domain capability within NekRS. This novel GPU-accelerated capability allows different spatial regions of the domain to be solved independently, enhancing the code’s efficiency, particularly when running large-scale simulations in complex domains. The scalability of this approach is demonstrated, highlighting its potential to transform how transients are approached in CFD simulations. Lastly, the report focuses on how this overlapping domain capability specifically accelerates transient simulations through multi-rate timestepping. By decoupling different regions and facilitating faster computations, this method offers a promising pathway to making nuclear transient simulations more computationally feasible, addressing one of the critical bottlenecks in the field. Together, these advancements represent a significant leap forward in transient simulation technology, bringing closer the possibility of handling highly complex nuclear scenarios with greater efficiency and accuracy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon-shot-noise-limited transient absorption soft X-ray spectroscopy at the European XFEL

Femtosecond transient soft X-ray absorption spectroscopy (XAS) is a very promising technique that can be employed at X-ray free-electron lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here, a dedicated setup for soft X-rays available at the Spectroscopy and Coherent Scattering (SCS) instrument at the European X-ray Free-Electron Laser (European XFEL) is presented. It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot by shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, an imaging detector capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst is employed, and allows a photon-shot-noise-limited sensitivity to be approached. The setup and its capabilities are reviewed as well as the online and offline analysis tools provided to users.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 03: Energy dependence of a clinical probe-format calorimeter and its pertinence to absolute photon and electron beam dosimetry

Purpose: To evaluate the intrinsic and absorbed-dose energy dependence of a small-scale graphite calorimeter probe (GPC) developed for use as a routine clinical dosimeter. The influence of charge deposition on the response of the GPC was also assessed by performing absolute dosimetry in clinical linac-based electron beams. Methods: Intrinsic energy dependence was determined by performing constant-temperature calorimetry dose measurements in a water-equivalent solid phantom, under otherwise reference conditions, in five high-energy photon (63.5 < %dd(10){sub X} < 76.3), and five electron (2.3 cm < R{sub 50} < 8.3 cm) beams. Reference dosimetry was performed for all beams in question using an Exradin A19 ion chamber with a calibration traceable to national standards. The absorbed-dose component of the overall energy dependence was calculated using the EGSnrc egs-chamber user code. Results: A total of 72 measurements were performed with the GPC, resulting in a standard error on the mean absorbed dose of better than 0.3 % for all ten beams. For both the photon and electron beams, no statistically-significant energy dependence was observed experimentally. Peak-to-peak, variations in the relative response of the GPC across all beam qualities of a given radiation type were on the order of 1 %. No effects, either transient or permanent, were attributable to the charge deposited by the electron beams. Conclusions: The GPC’s apparent energy-independence, combined with its well-established linearity and dose rate independence, make it a potentially useful dosimetry system capable measuring photon and electron doses in absolute terms at the clinical level.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dispersive Fourier transformation for megahertz detection of coherent stokes and anti-stokes Raman spectra

In many fields of study, from coherent Raman microscopy on living cells to time-resolved coherent Raman spectroscopy of gas-phase turbulence and combustion reaction dynamics, the need for the capability to time-resolve fast dynamical and nonrepetitive processes has led to the continued development of high-speed coherent Raman methods and new high-repetition rate laser sources, such as pulse-burst laser systems. However, much less emphasis has been placed on our ability to detect shot to shot coherent Raman spectra at equivalently high scan rates, across the kilohertz to megahertz regime. This is beyond the capability of modern scientific charge coupled device (CCD) cameras, for instance, as would be employed with a Czerny-Turner type spectrograph. In this paper, as an alternative detection strategy with megahertz spectral detection rate, we demonstrate dispersive Fourier transformation detection of pulsed (~90 ps) coherent Raman signals in the time-domain. Instead of reading the frequency domain signal out using a spectrometer and CCD, the signal is transformed into a time-domain waveform through dispersive Fourier transformation in a long single-mode fiber and read-out with a fast sampling photodiode and oscilloscope. Molecular O- and S-branch rotational sideband spectra from both N 2 and H 2 were acquired employing this scheme, and the waveform is fitted to show highly quantitative agreement with a molecular model. Finally, the total detection time for the rotational spectrum was 20 ns, indicating an upper limit to the detection frequency of ~50 MHz, significantly faster than any other reported spectrally-resolved coherent anti-Stokes Raman detection strategy to date.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the effect of strain rate during the cyclic compressive loading of liquid crystal elastomers and their 3D printed lattices

Nematic liquid crystal elastomers (LCEs) are a unique class of network polymers with the potential for enhanced mechanical energy absorption and dissipation capacity over conventional network polymers because they exhibit both conventional viscoelastic behavior and soft-elastic behavior (nematic director changes under shear loading). This additional inelastic mechanism makes them appealing as candidate damping materials in a variety of applications from vibration to impact. The lattice structures made from the LCEs provide further mechanical energy absorption and dissipation capacity associated with packing out the porosity under compressive loading. Understanding the extent of mechanical energy absorption, which is the work per unit mass (or volume) absorbed during loading, versus dissipation, which is the work per unit mass (or volume) dissipated during a loading cycle, requires measurement of both loading and unloading response. Here, in this study, a bench-top linear actuator was employed to characterize the loading-unloading compressive response of polydomain and monodomain LCE polymers and polydomain LCE lattice structures with two different porosities (nominally, 62% and 85%) at both low and intermediate strain rates at room temperature. As a reference material, a bisphenol-A (BPA) polymer with a similar glass transition temperature (9 °C) as the nematic LCE (4 °C) was also characterized at the same conditions for comparing to the LCE polymers. Based on the loading-unloading stress-strain curves, the energy absorption and dissipation for each material at different strain rates (0.001, 0.1, 1, 10 and 90 s -1 ) were calculated with considerations of maximum stress and material mass/density. The strain-rate effect on the mechanical response and energy absorption and dissipation behaviors was determined. The energy dissipation ratio was also calculated from the resultant loading and unloading stress-strain curves. All five materials showed significant but different strain rate effects on energy dissipation ratio. The solid LCE and BPA materials showed greater energy dissipation capabilities at both low (0.001 s -1 ) and high (above 1 s -1 ) strain rates, but not at the strain rates in between. The polydomain LCE lattice structure showed superior energy dissipation performance compared with the solid polymers especially at high strain rates.

36 MATERIALS SCIENCE↗