The production of ultra-high purity single isotopes or tailored isotope mixtures by ICP-MS
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Purpose: The dose-response relationship of the parotid gland has been described most frequently using the Lyman-Kutcher-Burman model. However, various other normal tissue complication probability (NTCP) models exist. We evaluated in a large group of patients the value of six NTCP models that describe the parotid gland dose response 1 year after radiotherapy. Methods and Materials: A total of 347 patients with head-and-neck tumors were included in this prospective parotid gland dose-response study. The patients were treated with either conventional radiotherapy or intensity-modulated radiotherapy. Dose-volume histograms for the parotid glands were derived from three-dimensional dose calculations using computed tomography scans. Stimulated salivary flow rates were measured before and 1 year after radiotherapy. A threshold of 25% of the pretreatment flow rate was used to define a complication. The evaluated models included the Lyman-Kutcher-Burman model, the mean dose model, the relative seriality model, the critical volume model, the parallel functional subunit model, and the dose-threshold model. The goodness of fit (GOF) was determined by the deviance and a Monte Carlo hypothesis test. Ranking of the models was based on Akaike's information criterion (AIC). Results: None of the models was rejected based on the evaluation of the GOF. The mean dose model was ranked as the best model based on the AIC. The TD{sub 50} in these models was approximately 39 Gy. Conclusions: The mean dose model was preferred for describing the dose-response relationship of the parotid gland.
Purpose: To determine the dose-response relationship of the thyroid for radiation-induced hypothyroidism in head-and-neck radiation therapy, according to 6 normal tissue complication probability models, and to find the best-fit parameters of the models. Methods and Materials: Sixty-five patients treated with primary or postoperative radiation therapy for various cancers in the head-and-neck region were prospectively evaluated. Patient serum samples (tri-iodothyronine, thyroxine, thyroid-stimulating hormone [TSH], free tri-iodothyronine, and free thyroxine) were measured before and at regular time intervals until 1 year after the completion of radiation therapy. Dose-volume histograms (DVHs) of the patients' thyroid gland were derived from their computed tomography (CT)-based treatment planning data. Hypothyroidism was defined as increased TSH (subclinical hypothyroidism) or increased TSH in combination with decreased free thyroxine and thyroxine (clinical hypothyroidism). Thyroid DVHs were converted to 2 Gy/fraction equivalent doses using the linear-quadratic formula with {alpha}/{beta} = 3 Gy. The evaluated models included the following: Lyman with the DVH reduced to the equivalent uniform dose (EUD), known as LEUD; Logit-EUD; mean dose; relative seriality; individual critical volume; and population critical volume models. The parameters of the models were obtained by fitting the patients' data using a maximum likelihood analysis method. The goodness of fit of the models was determined by the 2-sample Kolmogorov-Smirnov test. Ranking of the models was made according to Akaike's information criterion. Results: Twenty-nine patients (44.6%) experienced hypothyroidism. None of the models was rejected according to the evaluation of the goodness of fit. The mean dose model was ranked as the best model on the basis of its Akaike's information criterion value. The D{sub 50} estimated from the models was approximately 44 Gy. Conclusions: The implemented normal tissue complication probability models showed a parallel architecture for the thyroid. The mean dose model can be used as the best model to describe the dose-response relationship for hypothyroidism complication.
Purpose: Peer reviewers' knowledge of author identity may influence review content, quality, and recommendations. Therefore, the International Journal of Radiation Oncology, Biology, Physics (“Red Journal”) implemented double-blinded peer review in 2011. Given the relatively small size of the specialty and the high frequency of preliminary abstract presentations, we sought to evaluate attitudes, the efficacy of blinding, and the potential impact on the disposition of submissions. Methods and Materials: In May through August 2012, all Red Journal reviewers and 1 author per manuscript completed questionnaires regarding demographics, attitudes, and perceptions of success of blinding. We also evaluated correlates of the outcomes of peer review. Results: Questionnaires were received from 408 authors and 519 reviewers (100%). The majority of respondents favored double blinding; 6% of authors and 13% of reviewers disagreed that double blinding should continue in the Red Journal. In all, 50% of the reviewers did not suspect the identity of the author of the paper that they reviewed; 19% of reviewers believed that they could identify the author(s), and 31% suspected that they could. Similarly, 23% believed that they knew the institution(s) from which the paper originated, and 34% suspected that they did. Among those who at least suspected author identity, 42% indicated that prior presentations served as a clue, and 57% indicated that literature referenced did so. Of those who at least suspected origin and provided details (n=133), 13% were entirely incorrect. Rejection was more common in 2012 than 2011, and submissions from last authors with higher H-indices (>21) were more likely to survive initial review, without evidence of interactions between submission year and author gender or H-index. Conclusions: In a relatively small specialty in which preliminary research presentations are common and occur in a limited number of venues, reviewers are often familiar with research findings and suspect author identity even when manuscript review is blinded. Nevertheless, blinding appears to be effective in many cases, and support for continuing blinding was strong.
Purpose: To demonstrate the large-scale clinical implementation and performance of an automated treatment planning methodology for tangential breast intensity modulated radiation therapy (IMRT). Methods and Materials: Automated planning was used to prospectively plan tangential breast IMRT treatment for 1661 patients between June 2009 and November 2012. The automated planning method emulates the manual steps performed by the user during treatment planning, including anatomical segmentation, beam placement, optimization, dose calculation, and plan documentation. The user specifies clinical requirements of the plan to be generated through a user interface embedded in the planning system. The automated method uses heuristic algorithms to define and simplify the technical aspects of the treatment planning process. Results: Automated planning was used in 1661 of 1708 patients receiving tangential breast IMRT during the time interval studied. Therefore, automated planning was applicable in greater than 97% of cases. The time for treatment planning using the automated process is routinely 5 to 6 minutes on standard commercially available planning hardware. We have shown a consistent reduction in plan rejections from plan reviews through the standard quality control process or weekly quality review multidisciplinary breast rounds as we have automated the planning process for tangential breast IMRT. Clinical plan acceptance increased from 97.3% using our previous semiautomated inverse method to 98.9% using the fully automated method. Conclusions: Automation has become the routine standard method for treatment planning of tangential breast IMRT at our institution and is clinically feasible on a large scale. The method has wide clinical applicability and can add tremendous efficiency, standardization, and quality to the current treatment planning process. The use of automated methods can allow centers to more rapidly adopt IMRT and enhance access to the documented improvements in care for breast cancer patients, using technologies that are widely available and already in clinical use.
Purpose: Tumor positional uncertainty has been identified as a major issue that deteriorates the efficacy of radiation therapy. Tumor rotational movement, which is not well understood, can result in significant geometric and dosimetric inaccuracies. The objective of this study was to measure 6 degrees-of-freedom (6 DoF) prostate and lung tumor motion, focusing on the more novel rotation, using kilovoltage intrafraction monitoring (KIM). Methods and Materials: Continuous kilovoltage (kV) projections of tumors with gold fiducial markers were acquired during radiation therapy for 267 fractions from 10 prostate cancer patients and immediately before or after radiation therapy for 50 fractions from 3 lung cancer patients. The 6 DoF motion measurements were determined from the individual 3-dimensional (3D) marker positions, after using methods to reject spurious and smooth noisy data, using an iterative closest point algorithm. Results: There were large variations in the magnitude of the tumor rotation among different fractions and patients. Various rotational patterns were observed. The average prostate rotation angles around the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) axes were 1.0 ± 5.0°, 0.6 ± 3.3°, and 0.3 ± 2.0°, respectively. For 35% of the time, the prostate rotated more than 5° about the LR axis, indicating the need for intrafractional adaptation during radiation delivery. For lung patients, the average LR, SI, and AP rotation angles were 0.8 ± 4.2°, −0.8 ± 4.5°, and 1.7 ± 3.1°, respectively. For about 30% of the time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotation was detected in 2 of the 3 lung patients. Conclusions: The prostate and lung tumors were found to undergo rotations of more than 5° for about a third of the time. The lung tumor data represent the first 6 DoF tumor motion measured by kV images. The 6 DoF KIM method can enable rotational and translational adaptive radiation therapy and potentially reduce treatment margins.
Purpose: To assess, in a phase 2 study, the efficacy and toxicity of stereotactic body radiation therapy for oligometastases to the lung in inoperable patients. Methods and Materials: Patients with lung metastases were included in this study if (1) the primary tumor was controlled; (2) patients were ineligible for or refused surgery and chemotherapy; and (3) patients had 5 or fewer metastatic lesions in no more than 2 organs. Large peripheral tumors were treated with a dose of 60 Gy (3 fractions), small peripheral tumors with 30 Gy (1 fraction), central tumors received 60 Gy (5 fractions), and mediastinal tumors or tumors close to the esophagus received 56 Gy (7 fractions). Results: Thirty patients with 57 metastatic lung tumors from various primary cancers were analyzed. The median follow-up was 36 months (range, 4-60 months). At 2 years, local control for the 11 central tumors was 100%, for the 23 peripheral tumors treated to 60 Gy it was 91%, and for the 23 tumors treated in a single 30-Gy fraction it was 74% (P=.13). This resulted in an overall local control rate at 1 year of 79%, with a 2-sided 80% confidence interval of 67% to 87%. Because the hypothesized value of 70% lies within the confidence interval, we cannot reject the hypothesis that the true local control rate at 1 year is ≤70%, and therefore we did not achieve the goal of the study: an actuarial local control of the treated lung lesions at 1 year of 90%. The 4-year overall survival rate was 38%. Grade 3 acute toxicity occurred in 5 patients. Three patients complained of chronic grade 3 toxicity, including pain, fatigue, and pneumonitis, and 3 patients had rib fractures. Conclusions: The local control was promising, and the 4-year overall survival rate was 38%. The treatment was well tolerated, even for central lesions.
Purpose: To evaluate, in Japan Clinical Oncology Group study 0403, the safety and efficacy of stereotactic body radiation therapy (SBRT) in patients with T1N0M0 non-small cell lung cancer (NSCLC). Methods and Materials: Eligibility criteria included histologically or cytologically proven NSCLC, clinical T1N0M0. Prescribed dose was 48 Gy at the isocenter in 4 fractions. The primary endpoint was the percent (%) 3-year overall survival. The threshold % 3-year survival to be rejected was set at 35% for inoperable patients, whereas the expected % 3-year survival was 80% for operable patients. Results: Between July 2004 and November 2008, 169 patients from 15 institutions were registered. One hundred inoperable and 64 operable patients (total 164) were eligible. Patients' characteristics were 122 male, 47 female; median age 78 years (range, 50-91 years); adenocarcinomas, 90; squamous cell carcinomas, 61; others, 18. Of the 100 inoperable patients, the % 3-year OS was 59.9% (95% confidence interval 49.6%-68.8%). Grade 3 and 4 toxicities were observed in 10 and 2 patients, respectively. No grade 5 toxicity was observed. Of the 64 operable patients, the % 3-year OS was 76.5% (95% confidence interval 64.0%-85.1%). Grade 3 toxicities were observed in 5 patients. No grade 4 and 5 toxicities were observed. Conclusions: Stereotactic body radiation therapy for stage I NSCLC is effective, with low incidences of severe toxicity. This treatment can be considered a standard treatment for inoperable stage I NSCLC. This treatment is promising as an alternative to surgery for operable stage I NSCLC.
Tension control is critical for maintaining good product quality in most roll-to-roll (R2R) production systems. Previous work has primarily focused on improving the disturbance rejection performance of tension controllers. Here, a robust linear parameter-varying model predictive control (LPV-MPC) scheme is designed to enhance the tension tracking performance of a pilot R2R system for deposition of materials used in flexible thin film applications. The performance of a tension controller may degrade due to disturbances associated with model uncertainties and the slowly-changing dynamics in R2R systems. We introduce a method that separately treats these two sources of disturbance. The controller utilizes an incremental model to eliminate the errors caused by the mismatch between the nominal model and the actual system. A tube-based MPC formulation combined with scheduled parameters adequately updates models and corrects for the time-varying dynamics. Constraints on the rated motor torque are incorporated in the MPC to maintain the controller reliability and avoid machine failures. We illustrate the operation of our control algorithm through simulation of an actual R2R system. The controller outperforms the benchmarks in terms of fast transient response and offset-free tension tracking. Furthermore, it also demonstrates immunity from variations due to parametric uncertainties.
Controlling the ion transport through graphene oxide (GO) membrane is challenging, particularly in the aqueous environment due to its strong swelling tendency. Fine-tuning the interlayer spacing and chemistry is critical to create highly selective membranes. We investigate the effect of single-site divalent cations in tuning GO membrane properties. Competitive ionic permeation test indicates that Cu 2+ cations dominate the transport through the 2D channels of GO membrane over other cations (Mg 2+ /Ca 2+ /Co 2+ ). Without/With the single-site M 2+ modifications, pristine GO, Mg-GO, Ca-GO, and Cu-GO membranes show interlayer spacings of ~13.6, 15.6, 14.5, and 12.3 Å in wet state, respectively. The Cu-GO membrane shows a two-fold decrease of NaCl (1 M) permeation rate comparing to pristine GO, Mg-GO, and Ca-GO membranes. In reverse osmosis tests using 1000 ppm NaCl and Na 2 SO 4 as feeds, Cu-GO membrane shows rejection of ~78% and ~94%, respectively, which are 5%–10% higher than its counterpart membranes.
Capacitive deionization (CDI) technologies have the potential to become cost-competitive alternatives to reverse osmosis for the treatment of brackish waters. In this study, we describe our findings on the effect of co-ion sorption and faradaic side reactions on our ion exchange resin functionalized desalination electrodes which passively capture salt and reject it upon charging. This system, which we previously reported on and refer to as electrically regenerated ion exchange (ERI), avoids the use of expensive ion exchange membranes in an effort to save costs. Surprisingly, we find that, compared to a reference CDI system, ERI electrodes capture salt most effectively at low applied voltages (0.5 mg/cm 3 at 0.8 V). Both CDI and ERI systems also seem to suffer from co-ion sorption effects which negatively impact salt adsorption. However, Faradaic side reactions at higher voltages (1 V and 1.2 V) which we track via pH measurements, serve as a detriment to CDI but seem to facilitate the functionality of ERI.
Herein this paper proposes a novel concept for the optimal design of multi-stage vacuum membrane distillation (VMD). Generally, a multi-stage VMD is designed with an equal temperature difference between each stage. However, such a design is energy inefficient and increases VMD area. An analytical methodology for calculating the optimal stage temperature is proposed. By selecting the optimal stage temperature, the energy efficiency and required membrane area can be potentially improved by 16% and 30%, respectively. The proposed concept applies to all heat sources, including latent, sensible, and waste heat. To illustrate the method, multi-stage VMD is integrated with the waste heat from a supercritical water desalination (SCWD) system to achieve zero liquid discharge. SCWD is an energy-intensive process, requires high-quality thermal heat (>450 °C), and exhibits high waste heat rejection. The integrated VMD-SCWD approach is approximately 50% more energy-efficient and 35% more cost-efficient than the standalone SCWD system. Compared to the commercially used brine concentrator and crystallizer, the multi-stage VMD-SCWD system is more energy efficient for feed concentrations >5%. VMD-SCWD system is 30% cheaper, due to less expensive membrane distillation modules compared to a brine concentrator. The proposed design concept can replace the brine concentrator and crystallizer as an improved alternative for a zero-liquid discharge desalination system.
We have presented the first embedded Runge–Kutta exponential time-differencing (RKETD) methods of fourth order with third order embedding and fifth order with third order embedding for non-Rosenbrock type nonlinear systems. A procedure for constructing RKETD methods that accounts for both order conditions and stability is outlined. In our stability analysis, the fast time scale is represented by a full linear operator in contrast to particular scalar cases considered before. An effective time-stepping strategy based on reducing both ETD function evaluations and rejected steps is described. Comparisons of performance with adaptive-stepping integrating factor (IF) are carried out on a set of canonical partial differential equations: the shock-fronts of Burgers equation, interacting KdV solitons, KS controlled chaos, and critical collapse of two-dimensional NLS.
This paper describes a kinetic model and a corresponding Monte Carlo simulation method for excitation/deexcitation and ionization/recombination by electron impact in a plasma free of external fields. The atoms and ions in the plasma are represented by continuum densities and the electrons by a particle distribution. A Boltzmann-type equation is formulated and a corresponding H-theorem is formally derived. An efficient Monte Carlo method is developed for an idealized analytic model of the excitation and ionization collision cross sections. To accelerate the simulation, the reduced rejection method and binary search method are used to overcome the singular rate in the recombination process. Numerical results are presented to demonstrate the efficiency of the method on spatially homogeneous problems. The evolution of the electron distribution function and atomic states is studied, revealing the possibility under certain circumstances of system relaxation towards stationary states that are not the equilibrium states, a potential non-ergodic behavior.
In many areas of engineering and science there is an interest in predicting the probability of rare events, in particular in applications related to safety and security. Increasingly, such predictions are made through computer models of physical systems in an uncertainty quantification framework. Additionally, with advances in IT, monitoring and sensor technology, an increasing amount of data on the performance of the systems is collected. This data can be used to reduce uncertainty, improve the probability estimates and consequently enhance the management of rare events and associated risks. Bayesian analysis is the ideal method to include the data into the probabilistic model. It ensures a consistent probabilistic treatment of uncertainty, which is central in the prediction of rare events, where extrapolation from the domain of observation is common. We present a framework for performing Bayesian updating of rare event probabilities, termed BUS. It is based on a reinterpretation of the classical rejection-sampling approach to Bayesian analysis, which enables the use of established methods for estimating probabilities of rare events. By drawing upon these methods, the framework makes use of their computational efficiency. These methods include the First-Order Reliability Method (FORM), tailored importance sampling (IS) methods and Subset Simulation (SuS). In this contribution, we briefly review these methods in the context of the BUS framework and investigate their applicability to Bayesian analysis of rare events in different settings. We find that, for some applications, FORM can be highly efficient and is surprisingly accurate, enabling Bayesian analysis of rare events with just a few model evaluations. In a general setting, BUS implemented through IS and SuS is more robust and flexible.
This paper introduces HRSSA (Hybrid Rejection-based Stochastic Simulation Algorithm), a new efficient hybrid stochastic simulation algorithm for spatially homogeneous biochemical reaction networks. HRSSA is built on top of RSSA, an exact stochastic simulation algorithm which relies on propensity bounds to select next reaction firings and to reduce the average number of reaction propensity updates needed during the simulation. HRSSA exploits the computational advantage of propensity bounds to manage time-varying transition propensities and to apply dynamic partitioning of reactions, which constitute the two most significant bottlenecks of hybrid simulation. A comprehensive set of simulation benchmarks is provided for evaluating performance and accuracy of HRSSA against other state of the art algorithms.
A new Markov Chain Monte Carlo method for simulating the dynamics of particle systems characterized by hard-core interactions is introduced. In contrast to traditional Kinetic Monte Carlo approaches, where the state of the system is associated with minima in the energy landscape, in the proposed method, the state of the system is associated with the set of paths traveled by the atoms and the transition probabilities for an atom to be displaced are proportional to the corresponding velocities. In this way, the number of possible state-to-state transitions is reduced to a discrete set, and a direct link between the Monte Carlo time step and true physical time is naturally established. The resulting rejection-free algorithm is validated against event-driven molecular dynamics: the equilibrium and non-equilibrium dynamics of hard disks converge to the exact results with decreasing displacement size.